S0020029120-Nr 91 Repairs of The Electrical Installation in Škoda Vehicles
S0020029120-Nr 91 Repairs of The Electrical Installation in Škoda Vehicles
S0020029120-Nr 91 Repairs of The Electrical Installation in Škoda Vehicles
Škoda vehicles
Self-study programme
ŠKODA Service® 91
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Introduction
This publication was created with the aim of supporting the service network of Škoda in the proper execution of
repairs of the electrical installation for vehicles and summarises all the important principles and recommenda-
tions regarding the prescribed operation, use of recommended tools and equipment according to the valid service
documentation, including the notes for the corresponding passages in the current literature.
At the same time, the examples referring to incorrect repair procedures which are listed most often and occur
most frequently as well as their negative effects and recommendations on how the repair should be performed in
the correct way, are listed here.
The corresponding module of the service training is an addition to this Self-Study Programme No. 92.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
2 GB
Contents
Contents ................................................................................................................................................................................... 3
1. Škoda service documentation: Correct method of carrying out repairs of the electrical installation ............................ 5
3. List of valid TPI, referring to the repairs of the electrical installation in Škoda vehicles .....................................28
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 3
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
4 GB
1. Škoda service documentation: Correct method of carrying out
repairs of the electrical installation
Source: Škoda workshop manual; electrical systems - general information; 97 - cable - selected chapters relating
to the repairs of the electrical installation.
1.1. Compliance with the repair procedures according to the valid service documentation
WARNING!
› On modules affixed with stickers that warn of high voltage in the system of the vehicle, the residual voltage
must be eliminated before the repair (e.g. switch on the consumer after disconnecting the battery and
subsequently switch it off again).
› Some tools have a protective cap which has to be refitted on the tip of the tool after using it, because of the
possible injury and damage to the tip.
Note
Note
› If possible, do not loosen the earth straps at the body (risk of corrosion).
› Comply with the current instructions in the relevant workshop manual when carrying out repairs.
Note
› Comply with the general repair instructions for the electrical system of the vehicle
› Do not solder
Protected when
by copyright. repairing
Copying theor electrical
for private systeminof
commercial purposes, partthe
or invehicle.
whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
› After
withpressing, the
respect to the press coupling
correctness must
of information in this shrink when
document. by ŠKODA
using
Copyright a hotAUTO
air gun
A. S.�in order to prevent moisture
from penetrating.
› The shielded cables, such as, for example, the cables for the speed and knock sensors, must not be
repaired. If damaged, they must be completely replaced.
› If the required cross-section of the conductor bundle does not exist in the repair set, the next larger
cross-section must be used.
› Mark the repair points with a yellow adhesive tape.
› The points of the cable set, which are marked with the yellow adhesive tape, identify the previous
repair.
› Carry out a function test after each repair. If possible display the faults stored in the memory,
erase the faults and if necessary carry out the basic setting of the repaired system using the
VAS diagnostics, measuring and information system
GB 5
1.2. Repair of the conductor bundles and plug connectors
Required special tools, test and measuring devices and auxiliary means
The service case contains the necessary tool (except the set of release tools) and the material.
Quality repairs of the electrical networks can be carried out with the service case. The repairs of the plug
connectors and interrupted lines can be carried out with the tools.
The complete repair instructions are used for the repair of crimped plug connectors and press couplings, that are
connected to the conductor bundles in the vehicle.
Repair instructions from the ⇒ Electronic catalogue of original parts (ETKA).
The crimping tool provided with three different pressing profiles and the hot air gun serve to shrink the press
couplings in order to properly connect the cables.
For any subsequent order, simply name the order number for the spare part which you can find in the converter
table enclosed with the operating instruction.
The set of release tools (cutter) is used to release various primary and secondary plug connectors in the terminal
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
trips. unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
The systems with circular plug connectors and the flat contacts with one or two detents can be properly released
or installed as well as the simple cables can be sealed using the cutters.
Note
› Additional information and use of the set ⇒ Operating instruction for the service case.
› The assignment of the correct release tools can be found in the table, see ⇒ Operating instruction
for the set release tools.
6 GB
1.2.1. Repair of the cables for pyrotechnic components
Note
› Comply with the general repair instructions for the electrical system of the vehicle.
› Comply with the general repair instructions for the conductor bundles and plug connectors.
WARNING!
Inadequate repairs of the cables for pyrotechnic components, e.g. airbag, belt tensioner, may result in
insufficient protection of the passengers.
› To ensure a quality repair, the repairs of the cables for pyrotechnic components must be carried out exclusively
with the service case for the repairs of electrical bundles using original spare parts (connector sockets,
contacts, conductors, see ⇒ Catalogue of original parts)
› The cables on individual airbag units must not be repaired.
› The corresponding airbag modules must be replaced for safety reasons in case of damage to the cables or the
plug connectors on the airbag modules.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
with respect to the Note
Note
› The repairs in the area of the
pyrotechnic components should be
carried out at a distance of at least
30 cm to the next connector socket.
This together with the marking of the
repair point with the yellow adhesive
tape enables a quick overview of
previous repairs.
› Both cables for the airbag igniters are
twisted with a twist length of
20±5 mm. This twist length must be
kept for the repair of the twisted cable.
GB 7
Note
› After the repair, both cables for the
airbag igniters must have the same
length.
Upon rotation of the conductors -1-
and -2- the length -A- = 20 mm must be
observed.
› Thus, the conductive part without
rotated conductors (-arrow- in the
repair point) must not be longer
than -B- = 100 mm.
Note
› Comply with the general repair instruc-
tions for the electrical system of the
vehicle
› Comply with the general repair instruc-
tions for the conductor bundles and
plug connectors
The cables for the CAN databus are provided with the
following colour coding:
› After the repair, the two bus lines must have the
same length. Upon rotation of the conductors -1-
and -2- the twist length -A- = 20 mm must be
observed.
› Thus, the conductive part without rotated conduc-
tors (-arrow- in the repair point) must not be longer
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
than -B- =unless
50 mm.authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
8 GB
1.3. Using the set for cleaning the contact areas VAS 6410
The repairs in the area of the contact transfers for threaded connections of cable sets in the high power circuit
and battery connection must be carried out with a set for cleaning the contact areas VAS 6410 (releasing and
charging current, grounding conductors, battery terminals and poles).
Note
› The repairs shown in the illustrations serve only as an example of how to use the set.
› Set for cleaning the contact areas VAS 6410
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 9
1.3.1. Repair of the cable lugs
Note
› To avoid breaking the threaded connection such as when exceeding the tightening torque, due to
the lack of static friction in the thread, no rust remover, contact spray or grease must be used on
cable lugs.
› The grey abrasive discs are only suitable for minor contaminations and "soft surfaces".
› The red abrasive discs are only suitable for minor contaminations and "hard surfaces".
WARNING!
Risk of accident!
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Note
› Alternatively, a grinding slip can be used.
10 GB
Note
› Clean the cable lug carefully, so that the zinc coating is not removed.
› In regards to the different thicknesses of the zinc coating, it is necessary to perform a visual inspection on the
cleaned surface in the course of the cleaning process.
› Before beginning the repair, the cause of damage must first be resolved, such as sharp edges of the body parts,
defective power consumers, corrosion, etc.
Note
› The required tightening torque must
be kept for an optimum contact of the
cleaned components.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 11
1.3.2. Repair of the threaded connections
WARNING!
Risk of accident!
Pay attention to the warning notes and safety instructions when working with batteries ⇒ Page 2.
Note
› To avoid breaking the threaded connection such as when exceeding the tightening torque , due
to the lack of static friction in the thread, no rust remover, contact spray or grease must be used
for battery terminals.
› The grey abrasive discs are only suitable for minor contaminations and "soft surfaces".
› The red abrasive discs are only suitable for minor contaminations and "hard surfaces".
Note
› Clean the threaded connection carefully, so that the zinc coating is not removed.
› In regards to the different thicknesses of the zinc coating, it is necessary to perform the visual inspection on
the cleaned surface in the course of the cleaning procedure.
› If the underlying layer of copper is exposed when removing the zinc coating, a galvanic cell can occur, causing
intense corrosion.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
12 GB
1.3.3. Cleaning the battery terminals and poles
WARNING!
Risk of accident!
Pay attention to the warning notes and safety instructions when working with batteries ⇒ Page 2.
Note
› To avoid breaking the threaded connection such as when exceeding the tightening torque , due to
the lack of static friction in the thread, no rust remover, contact spray or grease must be used for
battery terminals.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 13
1.3.4. Treatment with preservatives
Note
› The lack of preservatives can cause damage and failure of the on-board power supply.
› Risk of corrosion.
Note
› All threaded connections must be tightened to the specified tightening torque.
› Use a container with an attached hose for applying the preservative.
› Conservation wax is used for cool areas.
› Conservation wax for cavities is used for warm areas.
› The preservative automatically penetrates at the appropriate points through the capillary action.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
14 GB
2. Use of recommended tools and devices
The repairs of individual components of the electrical installation (conductors, plug connectors, terminal strips,
etc.) of the Škoda vehicles as of model year 1996 must only be carried out using the recommended set of tools and
components that are part of the service case.
Currently, it is recommended to use the VW-service case (VAS 1978B) that is also used by other corporate brands
for this purpose.
Legend
Note
These symbols with explanations are given in the operating instruction of the service case and
describe the various operations for the repair of the electrical installation of the vehicle.
Unlocking devices
CuttingProtected
off by copyright. Copying for private or commercial purposes, in partDirectional arrow
or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Warming up Additional information
GB 15
The service case VAS 1978B contains the following tools*:
Stripper with conductor cutter (stripping and cutting off the conductor)
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
* The description and the symbols are taken from the operating instruction enclosed in the service case.
16 GB
Crimping tool with adapter (crimping head for various sizes of swaged socket fittings)
yellow 12 red 11
2 2
for 0.35 mm for 0.5–1.0 mm
blue 11 yellow 11
for 1.5–2.5 mm2 for 4.0–6.0 mm2
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 17
Electrical hot-air fan with special nozzle (completion, shrinking and connection seal)
NOTE:
The operating instruction for the hot-air fan must be
strictly observed!
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
18 GB
Hot-air gas fan with special nozzle (completion, shrinking and connection seal)
NOTE:
The operating instruction for the hot-air gas fan must
be strictly observed!
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 19
Folding knife with a blade
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
20 GB
In addition to the service case, a set of release tools (cutter) is required for repairing the electrical installation,
for releasing the plug connectors from the terminal trips and for their reinstallation, in particular:
- universal device for releasing secondary fuses at terminal strips,
- unlocking devices for flat and circular connectors,
- assembly devices for fi tting the seals in the terminal strips.
The use of this set and the correct procedure for unlocking and releasing the plug connectors,
including their reinstallation, are described and illustrated in detail in chapter 5 of this SSP and
in the relevant operating instructions, which are enclosed with each set of release tools.
The following points are emphasised and extracted from the detailed description of individual operations,
see instruction VAS 1978B - technical information (enclosed with each case):
Safety instructions
For all repairs, please keep the current information enclosed in the relevant technical manuals and
in the manual "Service Technics".
Important:
Before working on the electrical system, the flat band of the battery must be disconnected.
Before carrying out the repair procedure, you must first of all eliminate the cause of the fault
(e.g. sharp edges of the body part, defective consumer, corrosion, etc.). For more information,
such as the instructions for the installation and removal of individual assembly parts, can be
found in the corresponding service manual.
Only yellow conductors must be used for the repair of cable sets. These yellow conductors and all
the points at the cable set, that are marked with the yellow insulating tape, identify the previous
repair.
A function test must be carried out after each repair. If necessary, you must read off the data in the
fault memory and restore the original state of the system.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 21
Assignment of individual conductors, conductor seals, swaged socket fittings,
press gutters
The service set VAS 1978B does not include all the cable cross-sections used in the vehicle. If the cable cross-
section is not available, you must use the next higher cross-section.
Bags which include the service conductors are colour marked. The conductor seals are in compartments that also
differ in colour. According to the colour marking, you can select the corresponding press coupling, conductor seal
and gutter for the crimping tool.
Example
If you want to use a conductor of 0.5 mm with the red identification from the bag, you must use the colour
identification for the following red press coupling. The red press coupling must further be pressed into the gutter
of the crimping tool marked in red. The corresponding conductor seal also lies in the compartment with the red
identification.
The service set VAS 1978B includes four different sizes of swaged socket fi ttings.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Contacts, gold contacts
22 GB
Heat-resistant cables
At various points in the vehicle - especially in the engine compartment - heat-resistant cables are used.
The heat-resistant cables can be recognised on the duller and softer insulation.
To carry out repairs on these conductors, only the heat-resistant cables must be used.
Conductor seal
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 23
Description of repair
Warning: When fitting the seal, make sure that the hot
end of the fan does not damage another cable or the
plastic parts.
24 GB
Repair of the interrupted conductor with two repair
points (two interruptions)
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 25
Safety instructions
When repairing the conductors in the area of the airbag and the seat belt tensioners as well as in
damp places, certain rules must be observed.
It is possible to repair a maximum of 2 points on each adapter!
The repair points increase the electrical resistance of the conductor and can cause faults in its own
diagnostic system.
Roll up the original cable set including the repair points. Mark the repair point with a yellow
insulating tape.
When repairing the airbag conductors and the seat belt tensioners as well as in damp places,
you must always crimp the swaged socket fittings. This will prevent corrosion.
26 GB
Unlocking and removing the terminal strips (fuse bodies with contacts)
The shapes of fuse bodies with contacts in the operating instruction are only informative and clearly describe the
work with the secondary fuse.
General notes
To unlock, always use specific unlocking devices. Contacts must never be released from the fuse body by force.
Details can be found in chapter 5.
The attachments of the chambers and pins can be found partly at the secondary fuse or on the rear of the fuse
body with contacts.
The secondary fuse differs from the rest of the fuse body with contacts in its colour. Thus, the identification of
the secondary fuse and the work procedure is made easier.
The installation points for the plug connections can be found in the chapters "Circuit diagrams", "Fault Finding
- Electrical" or "Installation points".
The detailed description for unlocking the fuse body with contacts can be found in the description of the set for
unlocking devices, VAS 1978/35.
For unlocking individual contact systems, comply with the operating instructions in the manual.
For repairs of electrical installations in Škoda vehicles as of model year 1996, a set of tools must be used which is
also included in the service case of Škoda (the order no. was S 504500V, currently this case is no longer available
and it has been fully replaced with the VW service case (VAS 1978B) from which it originated). The tools, devices,
components and repair procedure are identical for both cases (for details, see the relevant instructions enclosed
with the sets).
The Škoda service case does not include a set of release tools ("cutter") to release the contacts of the terminal
strips. For the repairs of the terminal strips with plug connectors, this service case is supplemented either.
A) with the set of release tools S 506815V and S 506825V
or
B) with the set of release tools VAS 1978/35, supplemented with the set S 506840V.
The use of all the sets is explained in the relevant operating instructions enclosed with the sets.
GB 27
3. List of valid TPI referring to the repairs of the electrical
installation in Škoda vehicles
The details regarding this technical product information as well as the other newly issued TPI,
can be found in ELSAPro or in the portal B2B.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
28 GB
4. Common errors when carrying out repairs to the electrical
installation
4.1. If the correct repair procedure is not observed, the following can occur
a) Faulty insulation of the cable connection near the lambda probe (possibility of moisture penetrating the
terminal strips of the lambda probe). The repair was not properly carried out TPI 2018564.
Correct procedure Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Use a service case to insulate the conductor ends so that the conductor insulation is ensured and moisture
penetration is avoided when using the corresponding press coupling and the following connector seal.
GB 29
b) The connection of interrupted conductors near the lambda probe is carried out by soldering (breakage of the
soldered connection during operation, inadequate moisture protection).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
Correct procedure with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Do not solder when repairing the electrical system of Škoda vehicles (see the general repair instructions
for cable sets and plug connectors in the workshop manual). Use a service case in order to connect the
corresponding conductors with the relevant press coupling and seal with the hot-air fan.
30 GB
c) When repairing the conductor bundle, re-establish the connection of several interrupted conductors at the
same position in the bundle (problems that arise from the increased diametre of the bundle at the repair point).
Incorrect!
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Correct
Correct procedure
Observe the operating instruction enclosed in the service case (see chapter 2 of this SSP, description of repair)
and the connection points of individual conductors shifting against each other).
GB 31
d) The wrong choice of the connection for conductors e.g. repair of the broken/interrupted conductor bundle
for the side or rear door at the point where the bundle bends when opening and closing the door (even after
the repair has been performed correctly, breaking of the repaired conductor will reoccur in close proximity to
the press coupling after a short period of time).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Correct procedure
Carry out the repair (connecting a new conductor with the recommended press coupling including seal) at the
point where breaking of the bundle cannot occur when the door is opened or closed.
32 GB
e) Failure to comply with correct values and incorrect attachment of the fuses when exchanging them in the
E-box (and the consequential problems and faults during vehicle operation).
Correct procedure Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Checking the fuse assembly in the E-box, replacing the poorly equipped fuses.
When replacing the fuses, observe their correct value and proper attachment in the E-box.
GB 33
4.2. Problems that may arise when installing non-original equipment and
accessories in Škoda vehicles
Škoda Auto recommends that only electrical equipment is installed in Škoda vehicles, that was approved by the
Škoda departments.
The additional installations of non-approved equipment and modifications of the electrical equipment of the
vehicle are not supported by Škoda Auto (see TI-07-001 on portal B2B).
When installing approved equipment, proceed exactly according to the specific installation instruction.
If the installation procedure is not observed (or when additionally installing non-approved equipment), not all of
the electrical functions of the vehicle will operate correctly. There may even be damage to the control units of the
vehicle.
In case of a complaint about a vehicle which was retrofitted with non-approved electrical equipment, this
equipment must be switched off before repairing or transmitting a "technical repair request" (the vehicle
must be restored back to its original condition).
If this is not done and it is determined that the fault was caused by an unauthorised additional installation,
the service is redebited by the warranty department.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
34 GB
4.2.2. Examples of service practice
a) When installing the non-original GPS, the GPS cable set was fi tted to the original electric installation of the
vehicle (to the cable set of the QC steering column electronics J527 and instrument panel). This prevented
the original bundle from moving freely, jamming and colliding with the steering column. The malfunction of
the insulation package, the body end of the conductor and the breakage of the fuse SC39 have been the
cause of the engine shutting off while driving and it was not possible to restart the engine.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Correct procedure
GB 35
b) When fitting the drawgear in a non-branded service station, a supply conductor of the drawgear was
connected to the supply conductor of the QC steering column electronics. The conductor coupling was
carried out improperly with a quick release coupling (see figure), that has caused the interruption of the
feed for the QC column electronics J527. The vehicle has stopped while driving and the engine could not
be restarted.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Correct procedure
Carry out the installation of the approved type of drawgear for the vehicle in a standard way according to the
installation instruction, which was approved by the vehicle manufacturer (see the point of view of Škoda).
Important note
At the end of this chapter it must be emphasised once more that when relating to the complaint
settlement in regards to the failure of the electrical installation in Škoda vehicles as a cause of
the use of incorrect tools and equipment, non-compliance with prescribed repair procedures,
where appropriate, the installation of non-approved equipment and accessories in the vehicle
is proven, the appropriate complaint to the responsible departments of Škoda is recognised in
any case or covered (the cost of repair and the correction of the consequences of the failure are
covered by the responsable who caused the error by ignoring the rules and recommendations,
no matter whether it is to the service organisation or the owner of the vehicle or not).
36 GB
5. Repairs of the plug connectors and terminal strips
In order to meet the standards of Škoda, the set of release tools recommended by the manufacturer for the
repair of plug connectors and terminal strips must be used ("cutter"), e.g. VAS 1978/35, supplemented by the
set S 506840V or the set of release tools S 506815V and S 506 825V, which have been recommended for the
repairs of the plug connectors and terminal strips using the service case of Škoda S 504500V).
Basic rules for removing the plug connectors with the release and recommended tools:
1. Determine whether the corresponding plug connector is secured with a secondary lock (if yes, first of all lock in
the recommended way).
2. Select a correct and undamaged tool which is intended for releasing and removing the plug connector in the
corresponding terminal strip.
3. Handle carefully (use minimum force when unlocking the locking tang) do not damage the terminal strip while
doing so).
4. Release the plug connector with back pressure (never by pulling it!).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless
5. Carefully by ŠKODA
authorised press onAUTO A. S. ŠKODA
the release and AUTO A. S. does not guarantee
recommended tool up or to
accept
theanychamber
liability end of the terminal strips (possibly up
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
to the fixed stop), hold it in this position while removing the plug connector without force.
GB 37
5.2. Using the set for unlocking and removing the plug connectors with
conductors from the terminal strips
Prior to unlocking and removing the plug connectors from the terminal strips, the so-called secondary fuse must
be unlocked. While doing so, only the prescribed unlocking devices must be used. (see instructions for use of
individual sets of release tools).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
NOTE:
In some cases, the secondary unlocking is carried out by shifting the safety comb a few mm (pull it out a little)
straigth ahead and thus the safety comb must not be fully removed from the terminal strip.
38 GB
Safety comb – another example for unlocking
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 39
b) Open the flap (see arrow)
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
40 GB
c) Lock the stop
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 41
5.2.2. Primary unlocking of the plug connectors in the terminal strip
Only use the prescribed unlocking devices according to the operating instructions referring to the individual sets
of release tools for the primary unlocking and removal of the plug connectors from the body of the terminal strips,
as well as for their reinstallation and sealing.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
42 GB
c) Releasing the secondary fuse
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 43
d) Releasing the secondary fuse
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
44 GB
e) Removing the terminal strip with
plug connectors after releasing
the secondary fuse (stop)
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 45
5.2.3. Installing the conductor with seal in the terminal strip
The procedure is described in the operating instruction for the service case and even for the set of release tools.
Installing the conductor with seal in the terminal strip is described on page 22 of this brochure.
Assembly devices for conductors with seal (set of release tools VAS 1978/35).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
46 GB
Examples for installing the conductors with seal in the terminal strips
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
GB 47
Inserting the plug connector with seal
into the terminal strip
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
48 GB
b) Conductor with plug connector and
seal ready for installation
GB 49
c) Conductor with plug connector and
seal ready for installation
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
50 GB
Inserting the plug connector with seal
into the terminal strip
Important note
The prerequisite for a successful fault elimination which has been repeated several times in full
scope is also valid for the repairs of plug connectors and terminal strips: Use only recommended tools
and procedures. If a fault occurs by ignoring the rules and recommendations of the manufacturer,
neither the appropriate complaints are acknowledged nor the cost of the repair is covered by the
company Škoda Auto.
GB 51
5.2. Selected cases of incorrect repair procedures for plug connectors and terminal strips
a) When repairing the electrical installation of the QC gearbox, the incorrect release tool was used and for
this reason there has been damage to the terminal strip socket and the corresponding pin (it was the
CAN high conductor between the terminal strip T25 and the QC gearbox). The vehicle stopped while
driving and the ESP warning light came on. The cause was the lack of contact on the deformed pin
in the terminal strip (see figure below).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Correct procedure
When repairing plug connectors and terminal strips, always use the recommended tools, devices and
components and proceed according to the manufacturer's recommendations.
52 GB
Notes
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Notes
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
Notes
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
87
Overview of the previously edited self-study programmes
No. Designation No. Designation
ŠKODA Service® 91