1. SEPLOS USB-RS485 adapter, just connect BMS with battery via SEPLOS
USB-RS485 adapter.
2. If the adapter needs wiring, connect the RJ45 cables according to the
3. If you buy adapters on the market, make sure the wiring diagram is as
2
BatteryMonitor Installation Guide www.seplos.com
3
BatteryMonitor Installation Guide www.seplos.com
Click the link > Click ‘02 Drive’ > Download the ‘BatteryMonitor Software Drive’
3. Double click ‘NET Framework’ to install drive first. And wait for the
progress bar to fill up. Then the BatteryMonitor software drive finished
installation.
4
BatteryMonitor Installation Guide www.seplos.com
Note: Some USB to RJ45 adapters need drive, please make sure you’ve
install the corresponding drive before formally run the BatteryMonitor
application.
Run the software
5
BatteryMonitor Installation Guide www.seplos.com
6. If a prompt dialogue box pops up, and indicates ’No agreement was
found, please load agreement’ like the following picture showed, please
click ‘OK’.
of 48v 100A 16S BMS for LiFePO4 battery.) within the ‘BatteryMonitor’
6
BatteryMonitor Installation Guide www.seplos.com
8. After the prompt dialogue pops up. Click ‘OK’. And the software will
7
BatteryMonitor Installation Guide www.seplos.com
10. Before connect with battery system. Make sure the ‘Decimal symbol’,
Control panel > Time & Language > Additional data, time & regional settings > Region >
Additional settings
8
BatteryMonitor Installation Guide www.seplos.com
11. Choose the port number, which is different for different computer
13. Different adapters may need different drive. (Some computers will
install drive automatically when the adapter is plugged in.) If there isn’t
9
BatteryMonitor Installation Guide www.seplos.com
15. If BMS fail to connect with battery, a prompt dialogue box will pop
up indicating the connection time out. Please check the port number and
10
BatteryMonitor Installation Guide www.seplos.com
17. After login successfully, choose the menu ‘upload parameter’. Then
double click the parameters that need to modify. And click ‘set all’ to
save the changes. Click ‘save as’ to export the settings for backup.
11
BatteryMonitor Installation Guide www.seplos.com
18. The ‘upload menu’ could also manage the ON/OFF of functions.
Double click to choose the switch status. And click ‘set all’ to save the
change.
12
BatteryMonitor Installation Guide www.seplos.com
20. Click ‘Real time’, and its background color will turn yellow. BMS will
21. And the record data can be read and saved though the ‘Real time
record’ menu. Click ‘Real time’ again, real-time recording will stop
updating.
13
BatteryMonitor Installation Guide www.seplos.com
22. Click the ‘History record’. All the historical data can be read and
saved.
during manufacturing. (Do not click unless being permitted, or the BMS
will be damaged, and SEPLOS will not responsible for the damage.)
电流校准和电压校准用于出厂质检,只有专业设备才能使用。 (未
担任何责任。)
14
BatteryMonitor Installation Guide www.seplos.com
24. Click ‘Calibrate’ - ‘Get time’ to get BMS time. If the date and time is
not accurate, click ‘Set time’ to updating. (Make sure the computer date
25. When multiple packs in parallel, make sure the DIP address is
15
BatteryMonitor Installation Guide www.seplos.com
27. Then the ‘BatteryMonitor’ installed successfully. All the cell voltage,
16