Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Boq 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

P a g e | 276

PART-5 (a)
Close Circuit TV (CCTV) surveillance for Building

1.1 S
cope of work involves SITC of suitable number of Day Night/ IR, IP based dome cameras, with
CAT-6 cable at sub-station, STP room, and all the main gates with suitable mounting
arrangement (on wall/ powder coated MS poles in a vandal proof housing).
1.2 The cameras shall be placed in such a manner so as to cover the entire Premises area under
surveillance. The system will be used for monitoring at a predetermined place within the
nearest STP plant on each drain. The proposed surveillance system shall consist of IP
dome/bullet camera and NVR (Network Video Recorder), VMS etc.
1.3 24/48 port layer-2, managed network switches with 10G SFP ports with all required connecting
accessories should be provided in the Plant Building for the Camera connectivity.
1.4 A layer- 3, networking switch with suitable network management functionality should be
provided in the control Room for the central network management and control.
1.5 E
stablishing Network control room for configuration, operation, monitoring and maintenance
with one number of full HD 42ꞌꞌ LED display along with one workstation common for STP and
Street Lighting at Trunk Drains.
1.6 Installation, configuration & customization of Video Management System either Integrated or
with separate server hardware and software support up to 50 channel @ 1080p and
expandable with equipped storage of RAID 5 protected 32TB capacity in single server shall be
provided.
1.7 Outdoor fixed Cameras should be capable of functioning in Day Night/ IR range up to 30 meter
and 30 meter for indoor Cameras, minimum illumination: colour-0.2 Lux and B/W-0.05 Lux,
resolution 1920×1080 pixels: 2.0 MP @ 25/30fps PAL with QUAD streaming and inbuilt video
analytics support to all the Cameras.
1.8 Complete system is to be designed as per above requirements and scheme along with layout
and inventory is to be submitted to the Engineer-in-Charge for approval before taking up the
installation work.
1.9 This will be the responsibility of the agency to get approval of CCTV network/layout from Delhi
Police and shall get integrate this network to Delhi Police network as per requirement of Delhi
Police within the nearest Police Thana.
CCTV CAMERA

A. DOME Camera:
1. Resolution: 2.0 MP (1920×1080 ) full HD,H.264,H.265
2. Focal Length: Motorized varifocal (2.8mm to 12mm / 3mm to 9mm).
3. Stream: QUAD streaming with min 4 stream should be configured simultaneously at
1920×1080@25FPS.
4. 50 FPS @ 5MP (Main Stream).
5. IRIS - P-Iris
6. Shutter speed - 1-3/10000 Sec
7. WDR - 120 DB
8. IR Range - Inbuilt IR – 40Mtr (min)
9. Certification - UL, CE, FCC
10. Dome Camera - IP 67, Rated IK 10
11. Auto ICR
12. ONVIF Profile S & G
13. SD card support up to 128GB.
14. Operating temperature - -30 to +60 degree centigrade.
15. Operating Humidity- 5% to 95%
16.Power Consumption – 9.6 watt to 12 watt (maximum).

B. VMS- Video Management System:


1. VMS should support notification window, Book Marks, virtual Window.
2. VMS should support Map View.
3. VMS should support area search feature, where Recording can be searched
According to the Area selected by Operator.
P a g e | 277

4. VMS should be ONVIF compliant.


5. VMS should have capability at least 4 Access Groups
6. All Cameras & VMS should be from same OEM.
7. VMS should support calendar search & specific time search.
8. Control of PTZ cameras using the client interface.

D. NVR :

1. IP video input- 64 ch upto 12MP resolution supported


2. Incoming bandwidth- Min. 300 Mbps
3. Outgoing bandwidth- Min. 200 Mbps
4. Recording resolution- Upto 12MP
5. Video o/p interfaces- 2 HDMI port;at least 1 supporting 4K resolution,
2 VGA port; atleast 1 supporting 2K resolution
6. Audio o/p 1 ch
7. Compression technique H.265,H.264
8. Live view/Playback resolution Upto 12MP resolution
9. Synchronous playback Up to 16 channels
10. Smart Playback function Should support Smart search for the selected area in the video
and smart playback to improve the playback efficiency.
11. VCA storage Should support saving the captured VCA Pictures for smart IPC’s
VCA detection.
12. SATA interfaces Hot swappable 8 sata interfaces with each supporting 8TB,
should support ANR technology
13. Power supply Should Supports redundant power supply to improve the
system stability.
14. RAID arrays RAID0, RAID1, RAID5, RAID 6, RAID10
15. Hot spare function Should support N+1 hotspare function
16. Network interfaces 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface
17. Serial interfaces RS-232, RS-485; Keyboard
18. USB interface 3 × USB connectors, with atleast 1 USB 3.0
19. Alarm i/o 16 i/p and 4 o/p
20. Power supply 100 to 240 VAC, 50 to 60 Hz (Dual Power, Redundant)
21. Consumption (without hard disk) ≤ 30 W
22. Working temperature -10 to +55º C (+14 to +131º F)
23. Working humidity 10 to 90 %
24. Certification UL,CE,FCC,BIS

E. NETWORK SWITCHES:

1. Layer 2 POE Switch – should support 4 K VLAN, Private VLAN, Q In Q VLAN,


STP, RSTP, MSTP.
2. Camera should support Dynamic ARP Inspection.
3. Should support Link Aggregation Protocol (LACP).
4. JUMBO Frame up to 9216 Bytes.
5. Should support CIDR.
6. Should support QOS.

E. LAYER 3 SWITCHES:
1. Layer 3 switch 24 SFP Ports, 10Gbps, 4 x Copper Ports
2. Camera should support Dynamic ARP Inspection
3. Should Support Link Aggregation Protocol (LACP)
4. JUMBO Frame up to 3216 Bytes
5. Should Support CIDR
6. Should Support QOS.
7. L3 Features Protocols OSPF, RIP, EIGRP, VRRP.
8. Should Support MD5 authentication, Radius, Tacacs.
9. Should support MAC binding, WAR.
P a g e | 278

LIST OF ACCEPTABLE MAKE OF CCTV

S. No. Item Manufacturer’s name


1. Cameras/Housing Bosch/tyco (American Dynamics)/ Vicon/ Pelcol/ Axis/ Sony/
Panasonic/Impulse / Secura / D Link
2. VMS Genetec/ Mirasys/ Bosch/ Milestone/ DVTEL/ Tyco/ Axis/
Videonetics/ Pelcol/ onSSI/ Secura / D Link
3. LED Monitors Sony/Bosch/Samsung/Delta/ Barco
(Commercial series )
4. Storage Box Bosch/Tyco (American Dynamics)/ Axis/ Netapp/ Dell/ HP/ IBM
5. Servers Dell/HP/IBM
6. Conduits BEC/AKG/Precision
7. Cat-6 SFTP Wire Systemax/ AMP/ Molex/ Siemon/ Legrand/ Schneider / R&M/ AKS
including passive / Finolex
Components
8. HDPE Pipe Duraline/ Bestwell/ Ecoplast/ Berlia
9. Data switches and Cisco/ Juniper/ Xtreme / D-link
Routers
10. UTM/Fireball Cisco/Juniper/Cyberroam/Fortinet
P a g e | 279

PART-5 (b)
CCTV Surveillance on Outdoor light poles in Activity Areas

1.1
Scope of work involves SITC of suitable number of Day Night/ IP based Outdoor weather proof,
defogging IR bullet cameras, on Customized/Decorative poles installed in and around activity
areas like Food Street, fountain plaza, exhibition plaza, open air theatre, entry plaza, Toddlers
Park ,children park, yoga pavilion, sculpture court etc.
1.2 T
he cameras shall be placed in such a manner so as to cover the entire area required to be
secured. The system will be used for monitoring at a predetermined place within the premises.
The proposed surveillance system shall consist of supplying and installing camera and NVR
(Network Video Recorder), VMS, OFC cables (armoured and unarmored i.e. both as site
requirement) etc.
1.3 S
upply, laying OFC cables (armoured and unarmored i.e. both as site requirement) in
ground/HDPE pipe from NVR to CCTV cameras installed in activity areas on Customized/
Decorative outdoor light poles. It shall also include S/ laying DWC/HDPE pipes for laying of OFC
cables.
1.4 2
4/48 port layer-2, managed network switches with 10G SFP ports with all required connecting
accessories should be provided in the control room for the Camera connectivity.
1.5 A
layer- 3, networking switch with suitable network management functionality should be
provided in the control Room for the central network management and control.
1.6 E
stablishing Network control room for configuration, operation, monitoring and maintenance
with One number of full HD 42ꞌꞌ LED display along with one workstation.
1.7 I
nstallation, configuration & customization of Video Management System either Integrated or
with separate server hardware and software support up to 50 channel @ 1080p and
expandable with equipped storage of RAID 5 protected 32TB capacity in single server shall be
provided.
1.8 O
utdoor IP Cameras should be capable of functioning in Day Night/ IR range up to 30 meter,
minimum illumination: colour-0.2 Lux and B/W-0.05 Lux, resolution 1920×1080 pixels: 3.0 MP
@ 25/30fps PAL with QUAD streaming and inbuilt video analytics support to all the Cameras.
1.9 C
omplete system is to be designed as per above requirements and scheme along with layout
and inventory is to be submitted to the Engineer-in-Charge for approval before taking up the
installation work.
1.10 This will be the responsibility of the agency to get approval of CCTV network/layout from
Delhi Police and shall get integrate this network to Delhi Police network.

CCTV CAMERA

A. BULLET Camera:
1. Resolution: 3.0 MP (1920×1080) full HD,H.264,H.265
2. Focal Length: Motorized varifocal( 2.8mm to 12mm / 3mm to 9mm ).
3. Stream : QUAD streaming with min 4 stream should be configured simultaneously at
1920×1080@25FPS.
4. 50 FPS @ 5MP (Main Stream).
5. IRIS - P-Iris
6. Shutter speed - 1-3/100000 Sec
7. WDR - 120 DB
8. IR Range - Inbuilt IR – 30Mtr (min)
P a g e | 280

9. Certification - UL, CE, FCC


10. Bullet Camera - IP 67, Rated IK10
12. Auto ICR
13. ONVIF Profile S & G
14. SD card support up to 128GB.
15. Operating temperature - -30 to +60 degree centigrade.
16. Operating Humidity- 5% to 95% .
17.Power Consumption – 9.6 watt.
18. Dark fighter fixed bullet network camera.
19. Light performance via dark fighter technology
20. Whether proof, dust resistance (IP-67), and defogging provision.
21. Minimum illumination color: 0.005 lux @ (F1.2, AGC ON), 0 lux with IR, color: 0.009 lux @ (F1.6
AGC ON).

B. VMS- Video Management System:


1. VMS should support notification window, Book Marks, virtual Window.
2. VMS should support Map View.
3. VMS should support area search feature, where Recording can be searched according to the Area
selected by Operator.
4. VMS should be ONVIF compliant.
5. VMS should have capability at least 4 Access Groups
6. All Cameras & VMS should be from same OEM.
7. VMS should support calendar search & specific time search.
8. Control of PTZ cameras using the client interface.

C.NVR:
1. IP video input- 64 ch upto 12MP resolution supported
2. Incoming bandwidth- Min. 300 Mbps
3. Outgoing bandwidth- Min. 200 Mbps
4. Recording resolution- Upto 12MP
5. Video o/p interfaces- 2 HDMI port;at least 1 supporting 4K resolution,
2 VGA port; atleast 1 supporting 2K resolution
6. Audio o/p 1 ch
7. Compression technique H.265,H.264
8. Live view/Playback resolution Upto 12MP resolution
9. Synchronous playback Up to 16 channel
10. Smart Playback function Should support Smart search for the selected area in the video
and smart playback to improve the playback efficiency.
11. VCA storage Should support saving the captured VCA Pictures for smart IPC’s
VCA detection.
12. SATA interfaces Hot swappable 8 sata interfaces with each supporting 8TB,
should support ANR technology
13. Power supply Should Supports redundant power supply to improve the
system stability.
14. RAID arrays RAID0, RAID1, RAID5, RAID 6, RAID10
15. Hot spare function Should support N+1 hotspare function
16. Network interfaces 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface
17. Serial interfaces RS-232, RS-485; Keyboard
18. USB interface 3 × USB connectors, with atleast 1 USB 3.0
19. Alarm i/o 16 i/p and 4 o/p
20. Power supply 100 to 240 VAC, 50 to 60 Hz (Dual Power, Redundant)
21. Consumption (without hard disk) ≤ 30 W
22. Working temperature -10 to +55º C (+14 to +131º F)
23. Working humidity 10 to 90 %
24. Certification UL,CE,FCC,BIS

D. NETWORK SWITCHES:
1. Layer 2 POE Switch – should support 4 K VLAN, Private VLAN, Q In Q VLAN,
STP, RSTP, MSTP.
2. Camera should support Dynamic ARP Inspection.
P a g e | 281

3. Should support Link Aggregation Protocol (LACP).


4. JUMBO Frame up to 9216 Bytes.
5. Should support CIDR.
6. Should support QOS.

F. LAYER 3 SWITCHES:
G.
1. Layer 3 switch 24 SFP Ports, 10Gbps, 4 x Copper Ports
2. Camera should support Dynamic ARP Inspection
3. Should Support Link Aggregation Protocol (LACP)
4. JUMBO Frame up to 3216 Bytes
5. Should Support CIDR
6. Should Support QOS.
7. L3 Features Protocols OSPF, RIP, EIGRP, VRRP.
8. Should Support MD5 authentication, Radius, Tacacs.
9. Should support MAC binding, WAR.

LIST OF ACCEPTABLE MAKE OF CCTV

S. No. Item Manufacturer’s name


1. Cameras/Housing Bosch/tyco (American Dynamics)/ Vicon/ Pelcol/ Axis/ Sony/
Panasonic/Impulse / Secura / D Link
2. VMS Genetec/ Mirasys/ Bosch/ Milestone/ DVTEL/ Tyco/ Axis/
Videonetics/ Pelcol/ SSI/ Secura / D Link
3. LED Monitors Sony/Bosch/Samsung/Delta/ Barco
(Commercial series )
4. Storage Box Bosch/Tyco (American Dynamics)/ Axis/ Netapp/ Dell/ HP/
IBM
5. Servers Dell/HP/IBM
6. Conduits BEC/AKG/Precision
7. Cat-6 SFTP Wire including Systemax/ AMP/ Molex/ Siemon/ Legrand/ Schneider / R&M/
passive Components AKS / Finolex
8. HDPE Pipe Duraline/ Bestwell/ Ecoplast/ Berlia
9. Data switches and Routers Cisco/ Juniper/ Xtreme / D-link
10. UTM/Fireball Cisco/Juniper/Cyberroam/Fortinet
11 OFC Legrand/AMP/Siemens/Schneider/Finolex/Havells
Cables(Armoure/Unarmored)

You might also like