HMI
HMI
HMI
VOLUME 5 ISSUE 1
The VIEW
Visualization News & Products
October 2004
Enabled with FactoryTalk, ViewAnyWare offers an expanded suite of monitoring and control solutions built on a completely open architecture. It provides customizable graphic displays of real-time data. With the ViewAnyWare suitePanelView Plus, RSView Machine Edition, RSView Supervisory Edition, and RSView Studiousers can leverage existing data systems linked through a common visualization platform to minimize development time and cost, eliminate duplication, and share diagnostics to simplify maintenance. ViewAnyWare enabled with FactoryTalk from Rockwell Automation. See your Allen-Bradley distributor. For a free subscription to The VIEW magazine, call 1-800-223-5354, ext. 1670. Or visit: www.ab.com/viewanyware.
whatsinside
Barb Sines Vice-President and General Manager Control and Information Platforms Business Rockwell Automation
Welcome to a new issue of The VIEW magazine, a forum for visualization products and information from Rockwell Automation. The VIEW continues to deliver news, technical topics, and product selections focused on helping you find business success in your industry or application. Today, HMI solutions are taking on more of the attributes of traditional SCADA applications, using measurements such as key performance indicators and real-time analysis to help with that definition. To meet your expanding HMI demands, Rockwell Automation offers integrated visualization solutions that include hardware and software products to access, collect and display data, as well as analyze and provide measurements of your process work flow. Choosing Rockwell Automation HMI products also means you get visualization solutions designed to speed your application development and implementation, generate higher productivity and lower your overall HMI costs. This also means that your choice of visualization solutions are part of the ViewAnyWare strategy, a suite of monitoring and control solutions designed for virtually anywhere in your manufacturing enterprise. Read about Rockwell Automations Integrated Architecture and the ViewAnyWare strategy on the next page. Then, use The VIEW magazine to choose from the largest array of HMI platform types in the industry, the most comprehensive application solution packages, and the ideal configuration environment - RSView Enterprise Series. All are designed to give you the right information in the right place at the right time. Its all inside The VIEW !
I
4 5
Which Data Entry Type Is Right For You? I Visual Control Systems - A Lean Manufacturing Practice
New Views
I
Enhancements to VersaView, PanelView Plus, PanelView Standard, InView, and RSView Enterprise Series
TechKnowView
Tag Browsing in RSView Machine Edition Developing Applications with KEPServer Drivers I Network Connectivity Options for PanelView Plus and VersaView CE I FactoryTalk Activation I PanelView Standard - Proven Performance
I I
10
Features
In The Industries -Benefits and Value of HMI, Industries Show Us How I Customer Story -Industrial Radios Breathe New Life Into Old Quarry
I
18
22
Allen-Bradley VersaView Industrial Computers and Monitors Rockwell Software HMI Products
The VIEW magazine is published once a year. Circulation is by request. To request a subscription, use the Reply Card at the back of the magazine, or visit http://www.ab.com/viewanyware/subscribe.html. Address changes or corrections, email to ietimm@ra.rockwell.com. Thanks to Rockwell Automation Information Platforms Business and Rockwell Software staff for their time and expertise in contributing to this publication. If you have questions or comments, please contact:
50 56
The VIEW
The VIEW, Managing Editor I. Timm Rockwell Automation 1201 South 2nd Street Milwaukee, WI 53204 USA ietimm@ra.rockwell.com
RSView Enterprise Series RSView Studio RSView Machine Edition RSView Supervisory Edition RSView SE Station RSView32 Choosing HMI Software FactoryTalk Automation Platform
70 73 88
Following are trademarks and registered trademarks of Rockwell Automation, Inc: Allen-Bradley, Automation Desktop, CompactLogix, ControlLogix, Data Highway Plus, DF-1, DriveExplorer and Pocket Drive Explorer, FactoryTalk, FactoryTalk Activation, FactoryTalk Automation Platform, FactoryTalk Diagnostics, FactoryTalk Directory, FactoryTalk LiveData, FlexLogix, Integrated Architecture, InView, MicroLogix, PanelBuilder and PanelBuilder32, PanelView 'e', PanelView Plus, PanelView Standard, PLC-5, RAC6182, Rockwell Automation, Rockwell Software, RS Emulate 5/500, RSLinx Classix, RSLinx Enterprise, RSLogix and RSLogix 5000, RSMACC, RSPortal, RSSql, RSView Directory, RSView Enterprise Series, RSView Machine Edition, RSView SE Station, RSView Studio, RSView Supervisory Edition, RSView32, SLC and SLC-500, SoftLogix, The VIEW, VersaView, ViewAnyWare Trademarks not belonging to Rockwell Automation are property of their respective companies.
ViewAnyWare
When you need monitoring and control solutions for virtually anywhere in your manufacturing enterprise, youre talking about ViewAnyWare. Together with Logix for control and NetLinx Open Network Architecture for communication, ViewAnyWare is the visualization leg of Rockwell Automation's Integrated Architecture strategy. Applying the ViewAnyWare strategy means you are incorporating an information-enabled architecture into your enterprise one that delivers the right information to the right place at the right time. Youll have software and hardware solutions for machine-level and supervisory-level HMI. And with faster application development and implementation, youll realize higher productivity and flexibility, plus overall lower costs.
Manufacturers
As a manufacturer, driving higher returns on assets with more effective integration is probably an important concern. New levels of flexibility and speed of response in order to stay competitive can also help. Effective integration starts on the plant floor, and there is an easy and less costly way to get it. Avoid the need for a specialists expertise and costly communication gateways by considering Rockwell Automations Integrated Architecture.
Solid Solutions
ViewAnyWare solutions combine RSView Enterprise Series software for machine-level and supervisory-level HMI with dedicated and open hardware platforms including PanelView Plus operator interface terminals, InView message displays, VersaView CE and VersaView industrial computers and monitors.
Integrated Architecture
Whatever your application or industry, Rockwell Automations Integrated Architecture provides opportunities for cost-saving and productivity-enhancing solutions using a wide range of pre-integrated products, consolidating your application activities into a single coordinated system.
Picture This ... HMI Visualization Solutions for Your Industry, Your Application.
pointofview
What Else?
Bar code scanners, while part of material handling and packaging applications, are also an effective data entry tool. Look for more HMI applications incorporating these bar code scanners in the future. Another future data entry measure is wireless communications. With the shrinking size of HMI components and hand-held wireless devices, plant operators can take their HMI data anywhere on the plant floor. This is particularly useful when troubleshooting or sharing real-time information. While wireless has proven to be a fairly accurate medium, further refinements are needed before it could be considered suitable for critical application systems. Voice recognition systems are definitely a type of data entry, notes Victor Verissimo, Rockwell Automation. Theyre available today, but most if not all of the systems need refinement. For example, many systems may require that a command be repeated several times before the systems acknowledge the command. Security in voice recognition systems remains ..an area of concern, as a system must recognize the voice, according to Dorgelo. We run a serious risk if anyone could walk up to a computer and issue a command without providing identity information. Voice recognition systems have not yet reached the point of being able to filter one voice from another.
pointofview
Incorporating a visual control system into a plant layout can help a manufacturing process flow more efficiently and provide information to production and non-production departments.
Getting Started
Lean activities typically mean looking at an existing process or layout and finding places and ways to eliminate waste. The Japanese have a word for waste they call it muda. Examining specific areas of your company can help identify places where a lean design might help eliminate muda. 1. Process / Delivery Control includes monitoring production processes so that the correct part quantities are produced in the right way and at the right time. Planning is a vital part of this control, especially if last-minute rush jobs are a regular occurrence. 2. Quality Control increases production by reducing the number of parts that are produced out of spec. By catching defects right away, proper corrections can be made in a timely manner. Tracking bad parts, trending and other forms of analysis can be used to decrease the occurrences of defects. 3. Work Control it is just as important to monitor the flow of material through the production process, as it is to monitor the work process of employees. By reducing wasted time in both areas, production can become more efficient, and therefore more cost effective. 4. Object Control once production processes are standardized, it is much easier to monitor and adjust each stage. From ordering raw materials, to keeping track of parts in the making. Each step is simplified, reducing and even eliminating time wasted in searching, sorting, and rechecking parts. 5. Equipment, Fixture, and Tool Control time spent looking for tools not only accounts for lost wages, but also stops production processes from running smoothly. Knowing where tools are, and keeping them in proper working condition is one of the most effective ways of increasing production and reducing costs.
Using 5S
Exercising the 5S System is the first part of implementing a Visual Control System. While some may think that the completion of the 5S System means that a Visual Control System has been implemented, it is just the first part of the implementation. Mike Chan talks about how Rockwell Automation ventures into a lean initiative. 5S is the starting point for ALL process improvements: Sort, Set to Order, Shine, Standardize and Sustain are the 5Ss used to ensure the discipline (needed) to execute process improvements. The 5S process will help you group and visually understand the scope of items and the area in which the items are used. Creating lists of parts, materials, equipment and their locations will produce the documentation needed to maintain lean order. Next, evaluate the physical elements of your facility and create a new layout of the plant and its production lines. This is where planning a Visual Control System fits in. Questions that can prompt your visual control needs might include: Does the flow of work move smoothly from one station to the next, or does it jump around? Are storage and transportation methods efficiently aligned?
pointofview
InView Message Displays provide single to group communications, ideal for process alarming, safety messages, inventory or process data, test yields, daily output, or process cycle times. The largest InView display is visible from 450 feet for optimal viewing at both machine level and large areas of the plant floor.
PA N E LV I E W P L U S O P E R AT O R I N T E R F A C E
PanelView Plus Operator Interface modules are dedicated terminals ideal for machine control, monitoring start/stop status, and keeping track of cycle times. Features such as storing manufacturing values and performing statistical analysis such as trending and graphing are ideal for process control.
V E R S A V I E W C E I N D U S T R I A L C O M P U T E R S
VersaView CE Industrial Computers is an open Windows CE environment built on top of the functionality of a PanelView Plus operator interface module. This industrial computer provides machine control as well as access to manuals and drawings, drive configuration software, production schedules, as well as web access.
V E R S A V I E W I N D U S T R I A L C O M P U T E R S A N D M O N I T O R S
VersaView Industrial Computers and Monitors are HMI visualization solutions that work to both monitor and operate single machines or entire systems. They are ideal for machine or process control. Access to repair, maintenance, or start-up / set-up information, tool availability, and drawings means that these robust units works to lower ownership costs.
R O C K W E L L S O F T W A R E H M I P R O D U C T S
RSView Enterprise Series is a line of HMI software products designed with a common look, feel and navigation to help speed HMI application development and training time. RSView Enterprise Series includes RSView Studio, a PC-based development tool that allows users to create applications in a single design environment.
For more information on Lean Initiatives, Lean Manufacturing, and Visual Control Systems, visit: www.ame.org | www.productivitypress.com | cpd.engin.umich.edu | www.lean.org | www.sme.org
newviews
Two ACP-enabled VersaView 200R computer configurations available: One with no hard drive, limited RAM and no OS. The other with a hard drive, extra memory, and an OS that can be booted when no ACP server is available.
Want full-color intuitive machine control with preferred compatibility to Rockwell Automation logic controllers in a small interface package? The newly enhanced PanelView Standard 600 offers all this plus a new long-life backlight and full color TFT technology. Look for the new version of PanelView Standard application software, PanelBuilder32 V3.81.
newviews
RSView Enterprise 3.20
New features common to both RSView Machine Edition(ME) and RSView Supervisory Edition(SE) include the following: I RSView Studio Enterprise and SE Runtime Windows 2003 server support I RSView ME and RSView SE Windows XP SP2 support I RSView Enterprise localization - French, German and Japanese available December of 2004 I RSView ME and RSView SE graphics XML import/export. Import and export displays and graphic objects from RSView Studio into a text file. Use to automate screen configuration with other software or make repeat changes throughout an application New features in RSView Supervisory Edition RSView SE multiple domain support New features in RSView Machine Edition Display scaling when changing display resolution Alarm enhancements (color and visibility by alarm condition and multi-line alarms) ControlNet Scheduled - for both PanelView Plus and VersaView CE. ControlNet Scheduled for PanelView Plus 700-1500 and VersaView CE 700-1500 supports multi-cast outputs
9
techknowview
10
1. Add the Remote I/O Driver to the RSLinx Enterprise root directory 2. Configure the Racks and Block Transfers. 3. If you have data that is not a 16-bit integer or a bit address, you will need to assign an alias and select the data type. For ControlNet Scheduled, you will need to assign connections and aliases to match the configuration in RSNetworx for ControlNet. Refer to Help for further information. Once the file, controller or I/O driver has been configured, click on the shortcut name and then corresponding source (file, controller, I/O driver). Do not select a communication port or backplane as they do not store tags/addresses. Click on Apply. Each shortcut should have a unique source.
Click on the shortcut name you entered earlier to expand the folder. The folder Offline is the tag folder in the offline file if you assigned it to the shortcut. Subfolders match those in RSLogix 5000. The Online folder is the tag folder of the controller you browsed. Select the tag in the right hand side and select OK.
techknowview
11
Once the Target tab is configured, you can compile the runtime file and download to the PanelView Plus, the VersaView CE or the PC. As you become accustom to setting up and using the Tag Browsing tools, you will discover that it simplifies the coordination of your HMI and control development.
4. Set the project name as the default project. a. From the Menu bar, select "Tools>Options" b. On the General tab, click the ellipse button next to the "Default project" textbox. c. Select the desired .pfe file and click the Open button. This may not be the current configuration running in KEPware Server Enterprise. If you are testing the application on a PC, make sure the project name in the title bar of KEPServer Enterprise matches the "Project default" field. d. Click the Apply button and OK to accept the new project as the default. Included with KEPServer Enterprise is the OPC Quick Client, a simple tool for testing the communication configuration and tags. This way you can verify the configuration before you incorporate the KEPSever Driver into an RSView application.
techknowview
12
KEPServer Enterprise development software for configuring the communications is included with RSView Studio. Drivers for the PanelView Plus and VersaView CE are available at no additional cost and are included with the Firmware Upgrade files. For Windows 2000 / XP applications, the KEPServer EX drivers can be ordered. KEPServer drivers integrate with RSView Machine Edition or Supervisory Edition as an OPC Server. The KEPServer driver collects the data from the controllers or other devices on the network and serves the information to the RSView application.
KEPServer Drivers
WHEN YOUR NEEDS GO BEYOND THE ROCKWELL AUTOMATION NETWORKS, KEPSERVER DRIVERS EXPAND THE CONNECTIVITY OPTIONS.
1. Right click on the application name. Add an OPC Data Server and select KEPServer Enterprise as the OPC Server.
techknowview
Firmware can be upgraded over a Rockwell Automation network using RSLinx Enterprise or through a compact flash. 2. When assigning a tag to an object, use the Tag Browser and navigate to the channel name, device name and tag you created previously in KEPServer. 3. Create the runtime (.mer) file and download as you normally would. When the runtime file is compiled, the KEPServer Project information is included. Note: The pin out of the serial port on a PanelView Plus or VersaView CE is different than a computer. Typically using a 2711-NC13 straight through cable or adding a null modem adapter to the computer cable will suffice. Additional details are available in the Driver Help of KEPServer Enterprise and RSView Studio Online Book. Refer to the appropriate documentation for further information such as: RSView Enterprise or Studio online Help for OPC Server Hardware User Manual for PanelView Plus (2711P-UM001B) or VersaView CE (6182H-UM001B) for serial port pin out and instruction for downloading KEPServer drivers I Creating Modbus Applications User Manual (2711P-UM002A) for consolidated information on various Modbus drivers
I I
13
VersaView CE
VersaView CE is an open Windows environment industrial computer with a Windows CE.net operating system. The VersaView CE runs RSView Machine Edition and provides access to other applications.
techknowview
PanelView Plus
PanelView Plus is a dedicated operator terminal that runs RSView Machine Edition software.
14
FactoryTalk Activation
New FactoryTalk Activation will be replacing the current Rockwell Software activation software. FactoryTalk Activation is a software-based license management system that does not require a master disk. This will provide a more flexible licensing system with a concurrent activation option. The two types of license options include node-locked and concurrent. The node-locked license file is associated with a specific PC and network connection is not required. The concurrent option is networked and the application utilizes the license while connected to the network. This license supports users borrowing a license from the server for disconnected operation.
Node Locked
The functionality of the node locked license is most equivalent to Rockwell Softwares master disk activation without the hassles of a floppy disk or dependencies on a system file. The software is still licensed for use on a single computer. Product activation is associated with a hardware identifier in a personal PC that is selectable by the user. The resulting text formatted activation file is managed and secured by the user. The file is unaffected by system applications like, anti-virus products. With the ability to store numerous copies of the activation file recovery from hardware failure or a reformatted hard drive is now a simpler task capable of being handled by the users without assistance from Rockwell Software. Moving a node locked license to a different PC will require contact with the Rockwell Support Center. In most cases the current Rockwell Software catalog numbers will ship as node locked activation.
Become Mobile
Mobilize a node locked license by associating it with a USB dongle. This provides the benefit of being able to move from PC to PC while running Rockwell Software products. The text base license file can be copied on to any hard drive and the user is always guaranteed a license to run the product. There is no need to contact Rockwell Software to use that license on any or multiple PCs. A USB dongle is a purchased as a independent item and can be associated to any number of product activations.
techknowview
Concurrent
The functionality of the concurrent license is network capable licensing where products utilize activations stored in a central server location. Rockwell Software products can be installed in numerous locations throughout a facility without having to obtain and manage individual licenses for every PC. The number of licenses required is based on the number of simultaneous users running a particular Rockwell Software product. Administration of the licenses is greatly simplified with a central server. On PCs that are always connected to a network, the application is started and activation from the pool of licenses on the server is designated to that PC until the application is terminated. At which time it then becomes available to float or be used by a different PC. Sometimes it is advantageous to retain a dedicated license from the server. The functionality of borrowing licenses from the server and dedicating it to a particular PC allows the user to remove the PC from the network and still have full product licensing or guarantees use of a product on that PC at any time. Products that will be offering concurrent license capability will be providing new catalog numbers designating concurrent activation.
techknowview
I I I
techknowview
Tested units include: PanelView 550 (2711-B5Axx series H) terminals, showed a life expectancy of 6.67 years in a corrosive gas environment. The PanelView 550 keypad, touch and keypad/touch combination units are similarly constructed and would experience the same results. I PanelView 1000 (2711-K10Cxx series D and 2711-T10Cxx series D terminals in a corrosive gas environment can be expected to function for 10 years. The PanelView 1000 series D keypad and touch units would share that same life expectancy.
I
With 1600x1200 resolution, 60,000 hour backlight life, and 9U rack mount capability, the VersaView 2000M industrial monitor is the most feature-rich 20-inch flat panel monitor on the market today. Available in aluminum or stainless steel bezels with resistive touch screen option.
Pack more computing power on your plant floor. Allen-Bradley VersaView 12-, 15-, and 17-inch integrated display computers are now available with Intel Pentium 4 2GHz CPU, 512 MB RAM, and 40GB HDD.
In the Industries
Regulatory compliance
Stock America Inc. is an original equipment manufacturer that builds custom batch sterilizers known as retorts and associated equipment for food and pharmaceutical processors. The company wanted a supplier that would be able to keep up with industry software changes and new government regulations. To that end, Stock America was impressed by the relationships that Rockwell Automation had in place with various regulatory compliance groups. "As a small OEM, it's tough to stay on top of all the new government regulations impacting automation," said Tim Schurr, senior controls engineer, Stock America. "But Rockwell Automation is closely involved with 21 CFR Part 11 development activities and the Parenteral Drug Association Task Force, so they constantly build these latest requirements into their products. This allows us to offer the most up-to-date features to customers without having to be experts ourselves." To authenticate users, RSView Supervisory Edition uses Windows security, electronic signatures and authorization. Customers can set up users and grant rights to users based on roles. Operators logging in are prompted to enter an electronic signature and obtain verification. Via RSSql, all operator actions are logged in an external SQL Server database with the user name to create an audit trail of actions taken on the machine. "The larger security and auditing functions built into
ROCKWELL AUTOMATION IS CLOSELY INVOLVED WITH 21 CFR PART 11 DEVELOPMENT ACTIVITIES AND THE PARENTERAL DRUG ASSOCIATION TASK FORCE, SO THEY CONSTANTLY BUILD THESE LATEST REQUIREMENTS INTO THEIR PRODUCTS
RSView Supervisory Edition helped us see the integrity of the data acquisition and reporting," said Schurr. "Rockwell Automation deals with big-picture enterprise solutions all the time, so we knew that the tools used in our modular portion of production would integrate well with an enterprise solution." Stock America has also been able to provide support for 21 CFR Part 11 to customers who need it, without any custom development. The system automatically runs reports at the end of each shift that document the authentication and audit data required to meet the FDA's 21 CFR Part 11 compliance regulations. And, Stock America's customers understand the advantages of the new system as part of a migration toward more information-based systems. Looking forward, Stock America feels its customers will want to better leverage information to track maintenance and performance issues, and having the architecture to support those functions now will help customers in the future. "Our goal is to provide the best systems we can to our customers - ones that offer solutions for the needs they have today, and the needs they anticipate tomorrow," said Schurr. "Being able to find technology that offers the latest features, grows with the customer, and still allows us to customize is a valuable asset for our company."
18
Utilizing RSView32 software to program the beverage carrier assembly machine, Roberts PolyPro was able to cut its engineering time by 30 percent compared to similar applications using the previous software. Ray Neel, controls engineering manager at Roberts PolyPro credits this to RSView32s familiar and easy-to-use programming environment. The ability to use VBA code in RSView32 is a huge timesaver, said Neel. Plus, if youre trying to do something a little unusual, there are so many snippets of VBA code online that it makes it easy to research and figure out what you need to do.
In the Industries
The ActiveX capabilities in RSView32 also contributed to the time savings achieved by Roberts PolyPro. Engineers needed to include large onscreen numeric keypads on the operator screens of the beverage carrier assembly machine. To add this feature, Neel simply conducted a Web search for ActiveX numeric keypads, found an appropriate keypad, and it was instantly part of the application. In addition to the VBA and ActiveX savings, the ability to browse directly from RSView32 into the processor for tag names was another way we saved time, said Neel. This browsing capability is much easier than writing down the tag names and transposing them into a third-party package.
NEW STAINLESS-STEEL OPTIONS PROVIDE THE IDEAL SOLUTION FOR PLANT MANAGERS WHOSE MANUFACTURING EQUIPMENT AND CONTROLS MUST MEET EXACTING INDUSTRY CRITERIA
19
Going Wireless
In order to solve these problems, improve efficiency and coordinate the dredging with the classifying plant, a fully automatic system was needed. The first change Gottwald was determined to make involved installing radios in the dredge to communicate with the pumps and the classifying plant. I wanted to use wireless, said Gottwald, because wire is such a big headache. Gottwald started with consumer-grade radios. The classifying plant is on the other side of a major highway. The consumer radios were a disaster. They shut off when a plane flew by. We had several industrial radio companies look at this application. Some told us it couldnt be done. Others told us we would need expensive repeaters. ProSoft Technology came along and simply did it. ProSofts RadioLinx modems are by far the most robust radios I have
customerstory
Every wireless application is unique, said Wally Gastreich, RadioLinx Application Engineer for ProSoft. It is imperative that any company providing wireless communication know the specifics of the application. If the integrator does the proper leg-work up front, the reliability of the radios is a given. A RadioLinx Ethernet modem was placed at the classifying plant, the pump station and on the dredge. The classifying plant is nearly a half mile away from the dredge, which sits down in the water-filled quarry. In order to achieve line-ofsight between the two, the antenna at the classifying plant was placed on top of its 70 foot height. Another antenna was placed on the barge and a third at the remote booster pump station. No repeaters were needed. The radios durability in all climates combined with the flexibility of remote configuration and PLC programming make them perfect for applications that need real-time access to remote, difficult to reach or moving equipment, said ProSoft Technologys Ken Majerus. The versatility of their short and long-range antenna combinations allow local data to be transmitted up to 15 miles to a base station or further with single radio repeaters. Once Gottwald knew he could install a reliable radio system, he contacted Van Meter Industrial, an Allen-Bradley Distributor in Iowa. I like working with Allen-Bradley, said Gottwald. In my career as a contractor Ive had great success with A-B. They always have a solution to any application.
RiverStone Group Inc. a subsidiary of Central Stone, a sand and gravel company in West Quincy, Missouri. Im new to the mining industry, said Gottwald. So, when I started to work here I asked a lot of questions. Gottwald was surprised to learn that most of the technology used in the dredging operation was over 30 years old and obsolete. Everything was done manually, with no way to even measure pressure or flow from each of the pumps. When he asked the dredge operator how he could see what he was digging into under the water, he was told that they felt their way along. Much of the Convac system controlling the vacuum at the cutter head inlet needed to be replaced. The electrically operated control valve and control panel were a proprietary system that was inadequate for the needs of the operation. The old angle sensor on the cutter head also needed to be removed. Since the dredge rises and falls when the cutter head is touching bottom or free floating, it was impossible to determine a true cutter arm angle.
20
classifying plant control tags are served to the dredge computer, enabling remote viewing and control of the classifying plant. The VersaView in the classifying plant also provides all the information from the remote dredge computer, so operators can view all dredge information as well such as pump speed, motor amps, and cutter head depth.
Complete Control
With the new system in place, the fully automated dredge can now run not only the dredging operation, but also the booster pumps as well as the entire classifying plant. Sonar was installed on the dredge, and its readings are displayed on the VersaView monitor via RSView, giving the operator a clear view of the cutting arm and the sandy quarry bottom. We also installed a positioning sensor on the dredge that uses the magnetic field of the earth to tell us the heading of the dredge, its pitch and yaw and the angle of the cutting arm, said Gottwald. This allows us to know the exact depth of the sand at any given time. With all this new technology, the efficiency and costeffectiveness of the operation has been greatly increased. As Gottwald put it, Now all the dredge operator has to do is drive the boat!
customerstory
21
About the Author: Danetta Bramhall is the Staff Editor for ProSoft Technology, Inc. located in Bakersfield, California. ProSoft Technology is an international company specializing in industrial communication solutions, DIN rail mounted gateways and industrial wireless communications. For more information, visit ProSoft Technologys website at www.prosoft-technology.com.
" S AV I N G U S A P P R O X I M AT E LY $ 1 0 0 , 0 0 0 P E R Y E A R
Optimizing System Design and Development PanelView Plus is ideal for applications that need to display information graphically and log data so that operators can quickly understand the status of their equipment. On the plant floor, this means information delivery for optimal system efficiency. Part of the ViewAnyWare strategy, PanelView Plus is configured with RSView Studio and has RSView Machine Edition functionality, enabling the scalability of applications on a variety of platforms: operator interfaces, standalone Windows systems, and distributed servers.
CASEin point
OEM finds a cost-effective solution to remain competitive
Challenge A car wash equipment OEM was facing an extremely competitive landscape and needed an easy-to-use, cost-effective control and HMI solution for its application. The goal was to find a low-cost, flexible, off-the-shelf control solution so it could focus on perfecting the mechanical design of the auto-sizing touchless car wash. Solution The OEM looked at many options for control including singleboard custom solutions. After evaluating the MicroLogix 1500 and PanelView Plus 400 solution, the customer was sold on its capability and price point. The PanelView Plus application allows wash operators to easily navigate through menus to modify critical wash parameters, make seasonal changes, manage detergents and monitor system status. A custom Visual Basic application allows wash operators to dial in and troubleshoot the systems remotely. In addition to wash totals, material usage and daily receipts, processor status and I/O data is available to maximize the uptime of this state-of-the-art auto-sizing touchless car wash. An Allen-Bradley distributor was instrumental in configuring the control solution, the OEM rests assured that repair parts are available no matter the location of the wash bay. Results The customer's control and HMI challenges were met with MicroLogix and PanelView Plus. Seventy-five car wash distributors from US, Australia and New Zealand attended a recent open house at the OEM site and gave rave reviews for the ease-of-use and excellent troubleshooting capabilities built into this new wash system. 43% of the attendees placed orders for new systems. Plans are now in the works to double the customer's manufacturing capacity. With Rockwell Automation, this OEM found one clean solution.
22
Modular Components PanelView Plus offers component modularity so that design and maintenance teams can choose platforms that best fit their budgets, space requirements and environmental conditions. display/input modules for PanelView Plus 700 to 1500 common logic modules for PanelView Plus 700 to 1500 s communication modules for PanelView Plus 400 to 1500 s memory modules, RAM and Flash, for PanelView Plus 700 to 1500
s s
Advanced Graphic Features For maximum system optimization and diagnostics, the PanelView Plus lets you customize your system view to specific application needs: 18-bit color graphics to incorporate graphic pictures Trending plot time based on x-y data, plot up to 8 pens per trend s Expressions modify data based on conditions using logic or mathematical function s Data Logging record up to 300,000 values locally or remotely s Animation easily create system simulation movements
s s
Multiple Communication Options Offering connectivity to many PLC vendors, PanelView Plus is ready to communicate with Allen-Bradley, GE, Mitsubishi, Modbus, AutomationDirect, Omron, Siemens, Square D, and others via: DH-485 DH+ s RS-232 (DF1, DH-485, and 25 multi-vendor drivers) s Ethernet s Remote I/O s ControlNet for PanelView Plus 700 to 1500
s s
Re-using Development Tools With PanelView Plus, designers can re-use development efforts and share data across a wide variety of platforms and applications. One common development software package RSView Studio s FactoryTalk Diagnostics s Direct referencing of controller tags - eliminates duplicate HMI and controller tag database.
s
RSView Studio The development software RSView Studio is available in two versions. RSView Studio for Machine Edition is for developing Machine Edition projects only. RSView Studio for RSView Enterprise configures both Machine Edition and Supervisory Edition for distributed multi-server/multi-client applications. Both software packages support PanelView Plus application development. 9701-VWSTMENE RSView Studio for Machine Edition Development Software 9701-VWSTENE RSView Studio for RSView Enterprise Development Software
For complete HMI software information, see the Rockwell Software section of this publication, or visit www.software.rockwell.com.
23
RS-232 Driver Modularity fitting many PLC configurations DF1, DH-485, Over 25 other multivendor PLC drivers available
OPTIMAL SERVICEABILITY
PanelView Plus 700-1500 terminals provide a variety of modular display sizes, memory, communication, and labeling options. This gives OEMs and end users a standard base of common components and customized features to use across multiple applications. Common components help reduce maintenance procedures and inventory costs.
Driver Modularity fitting many PLC configurations Network Communication Modularity DH+/Remote I/O/ DH-485 combo module, ControlNet Built-in Ethernet for PLC communications or data transfer
Flexible peripheral support Display Module For ease of replacement and Interchangeability
Product identification and keypad legends for replacement and customization Bezel Module Easy Replacement
24
Cutout Migration Consider both the display size and the unit size when migrating to a new operator interface. PanelView Plus uses the same cutouts as existing PanelView product cutouts, yet offers a larger display area. When maintaining the same screen size, adapter plates are available to accommodate new PanelView Plus cutout.
Existing Terminal PanelView 550 or 600 Touch PanelView 550 Keypad or Keypad/Touch PanelView 600 Keypad or Keypad/Touch PanelView 900 PanelView 1000, 1000e PanelView 1200, 1200e CRT Touch PanelView 1200, 1200e CRT Keypad PanelView 1400, 1400e CRT RAC6182: 7.7" color RAC6182: 12.1" color Check for adapter plate availability Requires modification of cutout 3 Adapter plate required for a stud-mounted PanelView
1 2
Drop-in Replacement PanelView Plus 600 Touch, PanelView Plus 400 PanelView Plus 600 Keypad or Keypad/Touch PanelView Plus 700 Keypad or Keypad/Touch PanelView Plus 1000 PanelView Plus 1250 Not Available PanelView Plus 1500 3 PanelView Plus 1500 3 Not Available PanelView Plus or VersaView CE 1250
Adapter Plate Needed PanelView Plus 400 and 600 Touch PanelView Plus 600 Keypad or Keypad/Touch PanelView Plus 700 PanelView Plus 1000 PanelView Plus 1000 1 PanelView Plus 1250 2 PanelView Plus 1250 PanelView Plus 1250 Not Available PanelView Plus or VersaView CE 1000H
25
PanelView Plus Specifications - For catalog number selection, refer to page 75.
PanelView Plus 400 PanelView Plus 600 Grayscale PanelView Plus 600 Color
D I S P L A Y Type Size Resolution Replaceable Backlight Monochrome Passive Matrix, Film Compensated Super-Twist Nematic (FSTN) 78 x 59 mm (3.7 in) 111 x 84 mm (5.5 in) Color Active Matrix Thin Film Transistor (TFT) 111 x 84 mm (5.5 in) 320 x 240, 18 bit color graphics No Keypad 8 Function Keys, F1-F8 Keypad, Analog Touch Screen, or Combination 10 Function Keys, F1-F10 10 Function Keys, F1-F10
Operator Input Function Keys Real time Clock Memory Options Available Flash/RAM E L E C T R I C A L Communication Port Power Requirements Power Consumption Programming
Battery-backed time clock timestamps critical data. Accuracy +/-2 minutes per month Standard 32 MB/64 MB, Not Expandable Approximately 5 MB of available application memory.
RS-232 and (1) USB Only or Ethernet, RS-232, (1) USB, plus optional DH-485, DH+, or Remote I/O modules 18-30 Vdc or 85-264 Vac @ 47-63 Hz DC Power: 25 Watts max. (1.0A @ 24 Vdc) AC Power: 60 VA max. RSView Studio for Machine Edition or RSView Studio Enterprise Series
E N V I R O N M E N T A L Operating Temperature Storage Temperature Humidity Ratings Certifications 0 - 55C (32 - 131F) -25 70C (-13 158F) 5 - 95%, noncondensing @ 0 - 55C NEMA 12, 13, 4X , IP54, IP65 cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick
M E C H A N I C A L Weight Keypad or Keypad/Touch Weight Touch Only Dimensions Overall (H x W x D) .562kg(1.24 lb) N/A Keypad: 152x185x90 mm (6.0x7.28x3.54 in) .930kg (2.05 lb) .789kg (1.74 lb) Keypad or Keypad/Touch: 167x266x98 mm (6.58x10.47x3.86 in) Touch Only: 152x185x98 mm (6.0x7.28x3.86 in) .930kg (2.05 lb) .789kg (1.74 lb)
Cutout Dimensions
Keypad or Keypad/Touch: 142x241 mm (5.61x9.50 in) Touch Only: 123x156 mm (4.86x6.15 in)
26
Color Active Matrix Thin Film Transistor (TFT) 132 x 99 mm (6.5 in) 211 x 158 mm (10.4 in) 246 x 184 mm (12.1 in) 800 x 600, 18-bit color graphics 304 x 228 mm (15.1 in) 1024 x 768, 18-bit color graphics No
Keypad, Analog Touch Screen, or Combination 22 Function Keys, F1-F10 & K1-K12 32 Function Keys, F1-F16 & K1-K16 40 Function Keys, F1-F20 & K1-K20 40 Function Keys, F1-F20 & K1-K20
Battery-backed clock timestamps critical data Standard: 32 MB/64 MB; Extended: 128 MB/128 MB (for full color bitmaps or recording data); Standard: Approx. 13 MB flash; Extended: 115 MB flash available for application storage
Ethernet, RS-232, 2 USB plus optional communication modules 18-32 Vdc or 85-264 Vac @ 47-63 Hz 70 Watts max, 2.9 amps at 24Vdc (40 Watts nominal) RSView Studio for Machine Edition or RSView Studio Enterprise Series
0 55C (32 131F) -25 - 70C (-13 - 158F) 5 95%, noncondensing @ 0 55C NEMA 12, 13, 4X Indoor, (4X Outdoor with 1250 High-Bright) IP54, IP65 cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1, Zone 2, Group IIC; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick
1.9 kg (4.2 lb.) 1.7kg (3.8 lb.) Keypad or keypad/touch: 193 x 290 x 55 mm (7.58 x 11.4 x 2.18 in) Touch only: 179 x 246 x 55 mm (7.04 x 9.68 x 2.18 in)
2.9 kg (6.3 lb.) 2.6 kg (5.7 lb.) Keypad or keypad/touch: 248 x 399 x 55 mm (9.77 x 15.72 x 2.18 in) Touch only: 248 x 329 x 55 mm (9.77 x 12.97 x 2.18 in)
3.4 kg (7.6 lb.) 3.2 kg (7.1 lb.) Keypad or keypad/touch: 282 x 416 x 55 mm (11.12 x 16.36 x 2.18 in) Touch only: 282 x 363 x 55 mm (11.12 x 14.3 x 2.18 in) High-Bright Touch: 282 x 363 x 101.6 mm (11.12 x 14.3 x 4 in) Keypad or keypad/touch: 257 x 390 mm (10.11 x 15.35 in) Touch and High-Bright Touch: 257 x 338 mm (10.11 x 13.29 in)
4.6 kg (10 lb.) 4.2 kg (9.3 lb.) Keypad or keypad/touch: 330 x 469 x 65 mm (12.97 x 18.46 x 2.55 in) Touch only: 330 x 416 x 65 mm (12.97 x 16.37 x 2.55 in)
Keypad or keypad/touch: 167 x 264 mm (6.57 x 10.39 in) Touch only: 154 x 220 mm (6.08 x 8.67 in)
Keypad or keypad/touch: 224 x 375 mm (8.8 x 14.75 in) Touch only: 224 x 305 mm (8.8 x 12 in)
Keypad or keypad/touch: 305 x 419 mm (12 x 16.5 in) Touch only: 305 x 391 mm (12 x 15.4 in)
http://www.ab.com/eoi/graphicterminals/panelview_plus/index.html
27
A B
Width 400 Keypad 600 Keypad or Keypad/Touch 600 Touch 700 Keypad or Keypad/Touch 185 mm (7.28 in) 266 mm (10.47 in) 185 mm (7.28 in) 290 mm (11.40 in) 246 mm (9.68 in) 399 mm (15.72 in) 329 mm (12.97 in) 416 mm (16.36 in) 363 mm (14.30 in)
Height 152 mm (6.00 in) 167 mm (6.58 in) 152 mm (6.00 in) 193 mm (7.58 in) 179 mm (7.04 in) 248 mm (9.77 in) 248 mm (9.77 in) 282 mm (11.12 in) 282 mm (11.12 in)
Depth A 60 mm (2.35 in) 68 mm (2.68 in) 68 mm (2.68 in) 55 mm (2.17 in) display to logic module 55 mm (2.17 in) display to logic module 55 mm (2.17 in) display to logic module 55 mm (2.17 in) display to logic module 55 mm (2.17 in) display to logic module 55 mm (2.17 in) display to logic module 1250 High-Bright 39 mm (1.519") 65 mm (2.55 in) display to logic module 65 mm (2.55 in) display to logic module
Depth B 90 mm (3.53 in) 98 mm (3.86 in) 98 mm (3.86 in) 83 mm (3.27 in) display to comm modules 83 mm (3.27 in) display to comm modules 83 mm (3.27 in) display to comm modules 83 mm (3.27 in) display to comm modules 83 mm (3.27 in) display to comm modules 83 mm (3.27 in) display to comm modules 1250 High-Bright 74 mm (2.903") 93 mm (3.65 in) display to comm module 93 mm (3.65 in) display to comm module
Cutout width 156 mm (6.15 in) 241 mm (9.50 in) 156 mm (6.15 in) 264 mm (10.39 in) 220 mm (8.67 in) 375 mm (14.75 in) 305 mm (12.00 in) 390 mm (15.35 in) 338 mm (13.29 in)
Cutout height 123 mm (4.86 in) 142 mm (5.61 in) 123 mm (4.86 in) 167 mm (6.59 in) 154 mm (6.08 in) 224 mm (8.8 in) 224 mm (8.8 in) 257 mm (10.11 in) 257 mm (10.11 in)
700 Touch
1000 Touch
1250 Touch
1500 Touch
28
n/a n/a Serial Port with AIC to AIC+ to Ch. 0 1/2/5 Serial Port 2 n/a
with AIC with AIC to AIC+ to to AIC+ to Ch. 0 1/5 Ch. 0 1/5 Ch. 0 Ch. 0
with AIC to AIC+ to Ch. 0 1/2/5 Serial Port 2 with 1788-CNC or 1788-CNB 2
Ch. 0
n/a PLC-5C
yes 4
n/a
PLC-5E, or 1771-SN
yes 2/ 4/ 7
communications.
1. For isolation purposes if not used on the same power supply. 2. Symbolic (CIP) addressing. Example: Address = TankLevel. 3. PanelView Plus 700-1500 operator interface terminals. 4. Ethernet is supported through the PanelView Plus serial port with 1761-ENI. Check availability of direct Ethernet controller with an ENI. 5. RS-485 to AIC bridged to AIC+ to device. 6. RS-232 to AIC bridged to a AIC+ to device. 7. L35E
Use RSLinx or RSView Studio to upload and download project files with direct serial connection over the network or through gateway connections. Compact flash cards provide an alternative to connecting a PC to the PanelView Plus.
PanelView Plus Connector Standard RJ45 BNC or NAP 9-pin D-shell 3-pin terminal 6-pin terminal
Cables and PC Hardware Standard Ethernet cables 1784-PCICS or 1784-PKTCS 2711-NC13 or equivalent 1784-PKTX 1784-PKTX2
29
V ERSAV IEW CE
Industrial Computers
VersaView CE - A high performance Windows CE computer with a compact flash drive. There is no hard disk, no fan, and no moving parts, which means maximum reliability designed to move your platform applications into the future. Youre ready to go right out of the box. RSView Machine Edition is integrated, requiring no activation. Whats more, VersaView CE also includes:
s
A variety of Microsoft file viewers to view documents, drawings and training material right at the machine Networking capability to allow those files to be located on a central file server A version of Internet Explorer to view information located on a server either inside the plant or outside the company Terminal Services to work as a client to another computer running Windows XP or 2000 FTP Server to allow easy upload and download of files to the terminal from a remote location
CASEin point
Customer Reaps Benefits with Instant Communication
Challenge A manufacturer of corrugated board machinery needed a way to easily provide machine operations guides to the machine operators. Solution VersaView CE not only provides the operator control but also access to operations manuals located on a central file server.
30
Results Their customers can refine their processes and instantly communicate those changes to every machine operator.
The VersaView CE industrial computer is an open Windows CE environment built on top of the functionality and durability of PanelView Plus. The result is an operator terminal for your machine control that provides access to manuals and drawings, drive configuration software, production schedules on a web site, and more!
Similar to the VersaView industrial computers, the VersaView CE is an open platform where other applications can run at the same time as RSView Machine Edition. Several third-party applications have been tested with the VersaView CE. And if an application does not already exist, a custom application can be created using C++ for Windows CE, Visual Basic for Windows CE and the VersaView CE Software Development Kit (SDK included with VersaView CE).
Enhancements - Accessories CD
s s
Recipe ActiveX - to enhance RSView ME functionality Program Launcher ActiveX - used to launch a viewer, Internet Explorer, or any other executable from within RSView ME Backup/Restore utility - allows users to create a configuration and easily create a duplicate unit for either replacement or building another identical machine Allen-Bradley Industrial Computers >> VersaView CE VNC Client and Server - allows users to view a VersaView CE from a desktop and enter data directly to the VersaView CE VersaView CE Web Server - allows users to access snapshots of whatever is on a VersaView CE display via a web browser (no input capability is included) Additional XML Capability - XML Core Services can be expanded to correctly handle certain web-served data/objects within Internet Explorer or other application programs
Rockwell Automation DriveExplorer to configure and maintain Allen-Bradley drives. Visit www.ab.com/drives/drivesexplorer or see your local Allen-Bradley Distributor. Vendor applications such as CAD Viewer from Give-Me-Power. Visit www.givemepower.com for additional information. ActiveX components for use with RSView Machine Edition as well as with other applications described on the Rockwell Automation Knowledgebase. Visit http://support.rockwellautomation.com and reference Article G70654427, "Table of Contents for VersaView CE Software Applications and Devices."
For additional applications and application assistance, access Rockwell Automation Knowledgebase at http://support.rockwellautomation.com.
You can also use specifically designed applications from other software vendors, ActiveX or CE applications designed using C++, the on-board Software Development Kit, plus access more applications from the Rockwell Automation Knowledgebase at http://support.rockwellautomation.com. All this in addition to items on the Accessories CD and applications list on previous page. Easy to set up and maintain, VersaView CE means an open system that is rugged and economical, offering high functionality in an easy-to-use package. All this makes the VersaView CE another powerful component of the ViewAnyWare Strategy.
Mobile VersaView CE
Customers can now use the VersaView CE computers in mobile as well as permanent applications. Originally designed for fork trucks, the new enclosed, wireless version is ideal for applications that can benefit from the independence of communication cables. It works as part of a Cisco wireless system and supports 802.11b with WEP, LEAP and EAP-FAST encryption capabilities. For further information on this application, please contact Rockwell Automation's Global Manufacturing Solutions (GMS) group, Andreas Somogyi at asomogyi@ra.rockwell.com
DriveExplorer on VersaView CE
Installed on a VersaView CE, DriveExplorer reduces start-up time and improves access to maintenance information for a multiple drive system. Pocket DriveExplorer is used to edit drive parameters, upload and download configurations, update firmware, start and stop drives during startup, and access fault, alarm, and event information. The program launcher in RSView Machine Edition can open Pocket DriveExplorer with a simple press of a button, so the user never needs to access the Windows desktop to run the application. For VersaView CE dimensions and dimension drawings, refer to the PanelView Plus product section.
31
D I S P L A Y Size Type Resolution S Y S T E M Expansion Slots Processor Type Flash Memory RAM 6.5 in (165.1 mm) 10.4 in (264.16 mm) 12.1 in (307.34 mm) 15 in (381 mm)
Color active matrix thin film transistor (TFT) 640 x 480, 24 bit color C O M P O N E N T S 1 Compact Flash; ControlNet, DH+/DH-485/Remote I/O communication module option Intel Celeron 650 MHz Standard: 128 MB; extended: 256 MB (20 MB required for OS and ME) Standard: 128 MB; extended: 256 MB 1 serial port, 2 USB ports, 1 10/100 Mbps Ethernet port 800 x 600, 24 bit color 1024 x 768, 24 bit color
I/O E L E C T R I C A L Communication Ports Power Requirements Power Consumption Programming E N V I R O N M E N T A L Operating Temperature Storage Temperature Humidity Vibration Shock Ratings Certifications
RS-232, Ethernet and (2) USB, plus optional communication modules 18-32 Vdc or 85-264 Vac @ 47-63 Hz 70 Watts max, 2.9 amps at 24Vdc (40 Watts nominal) RSView Studio for Machine Edition or RSView Studio Enterprise Series
0 55C (32 131F) -25 70C (-13 158F) 5 95%, non-condensing @ 0 55C 0.012 in p-p, 1057 Hz, 2g peak, 57500Hz: operating and non-operating 15g operating, 30g non-operating NEMA Type 12, 13, 4X 1, IP54, IP65 cUL; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1, Zone 2, Group IIC;Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick
M E C H A N I C A L Weight Keypad or Keypad/Touch Weight Touch Only Dimensions Overall (H x W x D) 1.9 kg (4.2 lb.) 1.7kg (3.8 lb.) Keypad or keypad/touch: 193 x 290 x 55 mm (7.58 x 11.4 x 2.17 in) Touch only: 179 x 246 x 55 mm (7.04 x 9.68 x 2.17 in) 2.9 kg (6.3 lb.) 2.6 kg (5.7 lb.) Keypad or keypad/touch: 248 x 399 x 55 mm (9.77 x 15.72 x 2.17 in) Touch only: 248 x 329 x 55 mm (9.77 x 12.97 x 2.17 in) 3.4 kg (7.6 lb.) 3.2 kg (7.1 lb.) Keypad or keypad/touch: 282 x 416 x 55 mm (11.12 x 16.36 x 2.17 in) Touch only: 282 x 363 x 55 mm (11.12 x 14.3 x 2.17 in) High-Bright Touch 282 x 363 x 101.6 mm (11.12 x 14.3 x 4 in) Keypad or keypad/touch: 257 x 390 mm (10.11 x 15.35 in) Touch and High-Bright Touch: 257 x 338 mm (10.11 x 13.29 in) 4.6 kg (10 lb.) 4.2 kg (9.3 lb.) Keypad or keypad/touch: 330 x 469 x 65 mm (12.97 x 18.46 x 2.55 in) Touch only: 330 x 416 x 65 mm (12.97 x 16.37 x 2.55 in)
Cutout Dimensions (H x W)
Keypad or keypad/touch: 167 x 264 mm (6.57 x 10.39 in) Touch only: 154 x 220 mm (6.08 x 8.67 in)
Keypad or keypad/touch: 224 x 375 mm (8.8 x 14.75 in) Touch only: 224 x 305 mm (8.8 x 12 in)
Keypad or keypad/touch: 305 x 419 mm (12 x 16.5 in) Touch only: 305 x 391 mm (12 x 15.4 in)
32
1
The Allen-Bradley PanelView Standard operator interface terminals are extraordinary performers in the real world of control system automation. Youll find them working hard around the world, supporting the automotive, food and beverage, pulp and paper, water and wastewater, and petrochemical industries. Each terminal carries UL, cUL/CSA and CE certifications. They are rated for NEMA 4X (indoor) (IP54, IP65) and approved for Class 1, 2, and 3 Division 2 operation. These terminals are engineered for scalability, reliability, and compatibility for lower cost of ownership and improved productivity. PanelView terminals exemplify Rockwell Automations commitment to the highest standards of product dependability, technological innovation, and performance, and are backed with the highest levels of customer service and support in the industry. For a complete operator interface solution designed for rugged performance in a standalone or network environment, PanelView Standard is an extraordinary choice.
CASEin point
Demanding Applications Require Rockwell Automation Industrial Solutions.
Challenge A major manufacturer of compressors for military applications needed a dedicated HMI that would meet military shock and vibration standards. Solution Based on military standard testing, results showed the PanelView Standard 550 as the best solution for this application. Not only did the PanelView 550 pass testing, but the solid state long life LED backlight ensured that any maintenance would be minimal. The PanelView 550 was selected as the best solution. Results Using Rockwell Automation commercial industrial components has helped the military meet its mission goals more economically than with previously custom-designed systems.
33
Advanced Alarm Capabilities PanelView terminals can record and display important data on triggered alarms using an alarm list. With an alarm banner, operators and maintenance personnel are notified immediately to fault conditions.
Alarm banner alerts operators to fault conditions Alarm Lists record and display important alarm data
Screen Security Restrict access to application screens to authorized operators. Up to 16 passwords per application can be used to secure individual screens, allow access to configuration mode, and allow entry from screen saver or idle mode. Three screen security modes are available:
s s
screen mode prompts user for password when entering a secured screen login mode operator can move between any unsecured and secured screen for which the login password is valid auto login mode same as login mode, but login and logout keys are not required
Local Language Support PanelView terminals can display application screens in over 46 languages. Use the built-in extended ASCII character set for languages such as French, Italian, German, and Spanish. Or with an external font file, stored on an installed ATA memory card, display languages or other fonts supported by Windows. PanelView terminals now support up to 5 languages in a single application. Switch between English, French, Italian, German, and Spanish text while in run mode, without using an external ATA memory card.
PanelBuilder32 development software can be used to configure application screens with text in over 46 languages
34
EtherNet /IP certified EtherNet/IP compliant, connects and communicates with a PLC-5E, SLC 5/05, ENI module, and Logix 5000 controllers over the 1756 Ethernet bridge ControlNet Terminal certified ControlNet International compliant, communicates to multiple controllers on a ControlNet network, supporting scheduled and unscheduled PLC-5 and ControlLogix messages, and redundant cabling DeviceNet Terminal certified DeviceNet compliant, connects and communicates at a device level on a DeviceNet link (125k, 250k or 500k baud) using server explicit, client explicit, I/O or Listen Only messaging Data Highway Plus Terminal communicates to single or multiple PLC, SLC 5/04, and ControlLogix controllers over an Allen-Bradley DH+ network Remote I/O Terminal communicates to a PLC, SLC or ControlLogix system, supporting both discrete and block transferring of data
DH-485 Terminal communicates to single or multiple SLC or MicroLogix controllers on a DH-485 network RS-232 (DH-485 protocol) Terminal communicates point-topoint to a MicroLogix or SLC controller as a dedicated connection for high priority data, as well as the AIC+ module for DH-485 network communication RS-232 (DF1 protocol) Terminal communicates to a single SLC, PLC-5, or MicroLogix controller over a pointto-point DF1 link Profibus Terminal uses Profibus DP standard protocol for high-speed (up to 1.5M) data transmission to Siemens and other controllers Modbus Terminal uses half duplex, master-slave protocol to communicate over non-Rockwell Automation control architectures including Modicon and GE controllers
PanelBuilder32 Software
For quick and easy screen configuration PanelBuilder32 software supports the entire family of PanelView Standard terminals, allowing easy conversion and reuse of existing applications. A true 32-bit software package designed to operate on Microsoft Windows (including Windows 2000, ME, XP), PanelBuilder32 features an intuitive development environment to simplify application design, reduce development time, maximize performance, and improve productivity. Full complement of operator devices including push buttons, selectors, numeric and ASCII entry devices, diagnostic indicators, message displays, embedded numeric and ASCII variable displays, custom graphics and more resizeable bitmaps Remote device configuration for application file upload/download over Local Area Networks (LAN) using RSLinx and ControlLogix Gateway Import/export capability for the RSLogix software family of programming software for Rockwell Automation Logic Controllers. Create control tags once and export to RSLogix for use in the Logic Controller program Extensive compatibility with Microsoft Office tools including Excel where control tags can be created and edited and then imported into PanelBuilder32 and RSLogix Logic Controller packages. Use Microsoft tools to create, sort and organize your control tags Copyable .PDF documentation, Screen Print as well as development screen capture tools for the speedy creation of OEM specific manuals and documentation Operator interface support for all of Rockwell Automation Logic controllers and networks Open, re-use and save legacy PanelView Standard applications. Maintains the value in your PanelView investment Data Tips show the control behind the object. Tool tips remind you of tool functions
Popup alarm messages for instant notification Analog gauges offer an intuitive display method of numeric values Cut, copy, paste, and tag import/export capabilities in and between various PanelView application files for additional time saving advantages Multiple application files open at same time Extensive ControlLogix support including 32-bit data types, backplane addressing, and native symbolic addressing Support of up to 5 languages in a single application through the text editor function
35
3.0 (76.2 mm) diagonal transflective LCD (LED back-lit) monochrome graphic display, ideal for high ambient light applications 100,000 hour LED backlight life 128x64 pixel resolution 4 function keys and configurable cursor keys 1.4 (35 mm) installed depth Power 11 30V dc DF1 or DH-485 (RS-232) communication via 8-pin mini-DIN port Custom labeling available
PanelView 300
The PanelView 300 keypad operator interface terminal is a popular OEM choice. Designed for low-end graphical or text only operator interface applications, this terminal is faithful to the features found on PanelView Standard terminals. The LCD monochrome graphic display and featurerich design allow for high-performance in applications that demand a compact, less expensive interface.
3.0 (76.2 mm) diagonal transflective LCD (LED backlit) monochrome graphic display, ideal for high ambient light applications 100,000 hour LED backlight life 128x64 pixel resolution 8 relegendable function keys, numeric keypad, cursor control keys 2.7 (69 mm) installed depth Power 1832V dc DeviceNet, DF1, DH-485, and RS-232 (DH-485) communication options Custom labeling available
PanelView 550
Keypad, Keypad/Touch, Touch-Only Featuring blue-mode display with long-life LED backlight. These PanelView 550 Keypad, Keypad/Touch and Touchonly pixel-graphic display terminals are cost-effective ways for end-users and OEMs to incorporate high performance operator interface devices into applications or machines where panel space is limited. These terminals have a minimum installed depth and flat panel monochrome display designed to lower the cost of ownership without losing PanelView family functionality.
5.5 (139.7 mm) diagonal LCD monochrome display 256x128 pixel resolution Long life LED backlight 10 relegendable function keys, numeric keypad, cursor control keys 128 touch cells (touch and combo terminal only) 3.4 (86 mm) installed depth Power 85-264V ac or 18-32V dc
36
PanelView 600
Keypad, Keypad/Touch, Touch-Only The PanelView 600 Keypad, Keypad/ Touch, and Touch-only terminals are high performance color terminals for applications where color graphic displays are required and panel space is limited.
6.0 (152.4 mm) diagonal TFT active matrix color display 320x234 pixel resolution 10 relegendable function keys, numeric keypad, cursor control keys Power 85-264V ac or 18-32V dc 128 touch cells (touch and combo terminal only)
PanelView 1000
Color Keypad or Touch, Grayscale Keypad or Touch The PanelView 1000 is Rockwell Automations original entry in the medium size, color, flat panel operator interface segment. Its flat panel color or grayscale display, modest installed depth, operator input capabilities, alarm functions, and communication options have made it a popular workhorse in the growing operator interface market. Today, the PanelView 1000 shares the same comprehensive features found throughout the Allen-Bradley PanelView Standard family. Choose between keypad or touch screen input with either color or grayscale display, and nine different communication options. All are ready to network with the Allen-Bradley family of controllers as well as other PLC brands. These terminals have the same robust PanelView Standard hardware characteristics for installation in a wide range of environments and industrial applications.
Color version: 10.4 (264.16 mm) diagonal TFT active matrix color display; VGA 640x480 pixel resolution Grayscale version: 10.4" diagonal monochrome display; 640x480 pixel resolution Keypad version: 16 relegendable function keys, numeric keypad, cursor control keys Touch screen version: 384 touch cells 3.5 (90 mm) installed depth Power 85-264V ac or 18-32V dc
37
82 mm (3.21 in.)
69 mm (2.73 in.)
PanelView 300
PanelView 550
86 mm (3.39 in)
64 mm (2.54 in)
82 mm (3.20 in)
PanelView 550
38
PanelView 600
PanelView 1000
PanelView 1000
PanelView 1000
39
PanelView Standard Specifications - For catalog number selection, refer to page 75.
PanelView 300 Micro PanelView 300 PanelView 550 PanelView 550T
D I S P L A Y Type Size: Replaceable Backlight Operator Input Keypad N/A 4 (F1 - F4) 4 Nav/Function Keys Monochrome transflective LCD with integral LED backlight 2.87" x1.67" (73 mm x 42 mm) N/A 100,000 hour LED backlight life Keypad N/A 8 (F1 - F8) Keypad or Combination Keypad and Touchscreen 128 10 (F1 - F10) Touchscreen Only 128 N/A Monochrome LCD Blue Mode Display 4.75" x 2.38" (120 mm x 60 mm)
Touch Cells Function Keys Real time Clock Application Memory ATA Memory Card E L E C T R I C A L Communication Port
Battery-backed clock timestamps critical data 170K application runtime; 240K Flash (application objects + text + bitmaps) N/A Supported
RS-232 (DH-485 protocol), DF1, 8-pin Mini DIN connector N/A AC: N/A DC: 11-30 Vdc AC: N/A DC: 2.5 Watts max. (0.105A@24 Vdc)
EtherNet/IP, DeviceNet, ControlNet, DH+, Remote I/O, DH-485, RS-232 (DH-485 protocol), DF1, Profibus (1.56 MB), Modbus 1200, 2400, 9600, 19200 baud rate 1
AC: N/A DC: 18-32 Vdc AC: N/A DC: 10 Watts max. (0.42A@24 Vdc)
AC: 85-264 Vac DC: 18-30 Vdc 47-63 Hz AC: 45 VA max. DC: 18 Watts max. (0.75A@24 Vdc)
AC: N/A DC: 18-32 Vdc AC: N/A DC: 18 Watts max. (0.75A@24 Vdc)
E N V I R O N M E N T A L Operating Temperature Storage Temperature Humidity Ratings Certifications W E I G H T Keypad Touch Screen D I M E N S I O N S Keypad (H x W x D) Touch Screen (H x W x D)
1
0 55C (32 131F) -20 85C (-4 188F) 5 95%, noncondensing @ 0 55C -25 70C (-13 158F) -20 70C (-4 158F) 5 95%, noncondensing @ 0 30C NEMA Type 12, 13, 4x (indoor only), IP54, IP65 cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1 Zone 2; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick
6.6" x 10.5" x 4.2" (167.6 x 266.7 x 106.7 mm) 6.6" x 10.5" x 4.2" (167.6 x 266.7 x 106.7 mm)
40
PanelView 600
PanelView 600T
Color Active Matrix Thin Film Transistor (TFT) 4.54" x 3.4" (115 mm x 86 mm) Field Replaceable Keypad or Combination Keypad and Touchscreen 128 10 (F1 - F10) N/A 4.54" x3.43" (115 mm x 87 mm) N/A Touchscreen Only
Color Active Matrix Thin Film Transistor (TFT) 8.3" x 6.2" (211 mm x 158 mm) Field replaceable backlight
Black/White Monochrome
Keypad or Touchscreen
Battery-backed clock timestamps critical data 190K application runtime; 240K Flash 190K application runtime; 240K Flash (application objects + text + bitmaps) Supported 310K application runtime; 1008K Flash (application objects + text + bitmaps)
EtherNet/IP, DeviceNet, ControlNet, DH+, Remote I/O, DH-485, RS-232 (DH-485 protocol), DF1, Profibus (1.5 MB), Modbus
1200, 2400, 9600, 19200 baud rate AC: 85-264 Vac DC: 18-32 Vdc 47-63 Hz AC: 60 VA max. DC: 34 Watts max. (1.9A@24 Vdc) AC: N/A DC: 18-32 Vdc AC: N/A DC: 24 Watts max. (1.0A@24 Vdc) AC: 85-264 Vac DC: 18-32 Vdc 47-63 Hz AC: 70 VA max. DC: 27 Watts max. (2A@24 Vdc) AC: 85-264 Vac DC: 18-32 Vdc 47-63 Hz AC: 100 VA max. DC: 40 Watts max. (1.74A@24 Vdc)
5 95%, non-condensing @ 0 40C NEMA Type 12, 13, 4x (indoor only), IP54, IP65
cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1 Zone 2; Class 2, Div 2; Class 3, Div 1; CE marked; C-Tick
7.55" x 11.40" x 4.57" (192 x 290 x 116 mm) 7.55" x 11.40" x 4.57" (192 x 290 x 116 mm)
11.1" x 16.6" x 4.4" (282 x 423 x 112 mm) 11.1" x 14.6" x 4.4" (282 x 370 x 112 mm)
http://www.ab.com/eoi/graphicterminals/panelview_standard/index.html
41
DH+ DF1 DH-485 (RS485 physical connection) DH-485 (RS-232 physical connection) DeviceNet ControlNet EtherNet/IP
with AIC+*
with AIC+
Ch. 0
n/a
n/a
with 1761- NET DNI 5/02 with 1747-SDN with 1747-SDN with 1747-SDN with 1747-SDN with 1771-SDN n/a with 1761-NET-ENI n/a n/a no n/a no n/a no yes PLC-5C PLC-5E, 1785-ENET
* For isolation purposes if not on the same power supply. ** Legacy mode. Example: address = N7:0 *** Symbolic (CIP) addressing. Example: address = Tank level
* When connecting a personal computer to a PanelView Standard terminal, using a PIC without a controller connected, you need a power supply (1747-NP1)
42
* The controller must support PC network as well as PanelView network. Consult controller manual for details
PANELV IEW E
Operator Interface Terminals
Designed with high performance HMI functionality for complex process and large-scale control applications, these operator interface terminal workhorses provide powerful data processing capabilities, enhanced graphics and functions, flexible operator interface options, and powerful configuration software. Using PanelView 1200? We can help you leverage your PanelView 1200 investment by moving your current application to a PanelView 1000e. How? By migrating your older PanelView (2711-TA1, -TC1, -KA1, -KC1) to the PanelView e graphic terminals. Why migrate? It's easy! Yes, you can re-use your application files no need to reprogram. Yes, you can use existing panel cut-outs. Adapter plates are available. Yes, your PLC program and Remote I/O network functionality is maintained no PLC or Remote I/O network changes necessary. Whats the advantage? Youll have a new terminal with full factory warranty, minimizing repair cycle costs and down time concerns. Youll be prepared for the flexibility and scalability of Rockwell Automations ViewAnyWare strategy a full enterprise visualization strategy with a suite of monitoring and control solutions. More functionality and features to enhance your application.
173mm (6.8")
18mm (0.7")
24mm (0.96")
35mm (1.37")
92mm (3.64")
138mm (5.43")
37mm (1.46")
114mm (4.48")
282mm (11.11")
CASEin point
PanelView 1000e allows easy upgrades to maximize the life of capital equipment.
Challenge A major manufacturer of automobile components had a number of press stations rebuilt to extend their life and maximize their productivity. Performing this upgrade as economically as possible was a major challenge. Solution The old system consisted of a PanelView 1200 CRT based HMI with a Rockwell Automation PLC-5 based control system. To minimize the electrical and control system redesign costs, a new PanelView 1000e was selected as the new HMI, and a newer generation PLC-5 was installed. Results Migrating to the PanelView 1000e allowed the PanelView 1200 program to be re-used with minimal changes. The PLC-5 program was re-used in its entirety. The newly rebuilt system paid for itself quickly with increases in throughput and higher product quality.
43
Color, Active Matrix, Thin Film Transistor (TFT) 10.4 inch (26.4 cm) diagonal Field Replaceable Backlight Keypad or Touchscreen Up to 192 (analog resistive) 21 (F1 F21) Battery-backed clock timestamps critical data 2.25 MB On-Board Flash; expandable to 15.75 MB with external PC memory card PanelBuilder 1400e (Windows-based)
T R I C A L
Operator Input Touch Cells Function Keys Real Time Clock Application Memory Programming
E L E C
ControlNet, DH+, Remote I/O 1200, 2400, 9600, 19200 baud rate AC: 90-132 or 180-264 Vac, DC: N/A 90VA max 70W max
0 50C (32 122F) -25 60C (-13 140F) 95% Humidity (noncondensing) @ 50C (122F) NEMA Type 12 (Indoor Use Only), 4X, IP66 (Indoor Use Only) UL 50, 1992, ENCL 4X,12 (Indoor Use Only) CSA C22-2 No. 94-M91, ENCL 4X, 12 (Indoor Use Only) -
11.1" x 16.6" x 6.8" (282 x 423 x 174 mm) 11.1" x 14.6" x 6.8" (282 x 370 x 174 mm)
ControlNet
Remote I/O
N/A Use a pass-through connection Allen-Bradley Electronic Operator Interface >> PanelView e
ControlNet
ControlLogix/Gateway PLC-5
DH+
DF1
*The controller must support PC network as well as PanelView 'e' network. Consult controller manual for details
45
INVIEW
Message Displays
Delivering the Right
InView Message Displays deliver the 3 Rs the Right information, to the Right place, at the Right time. While the 3 Rs are important, so is the way the message is delivered for different applications. InView offers several solutions for process alarming, safety messages, inventory or process data, or thanking the team. While many products can communicate information to one person about a single process few can communicate to many at once. InView products offer 1- to 5-line displays, in red or tri-color LEDs for clear and colorful viewing from up to 450 feet (137.16 m).
CASEin point
InView reduces total system cost through its network capabilities and lean practices
Challenge A large automotive manufacturer used many different Rockwell Automation controllers and networks to operate different processes simultaneously. The manufacturer was looking for a way to standardize the communication of production status, quality control, and employee notifications throughout the facility. Solution InView's network capabilities allowed the user to create one solution, then implement that same solution on any network in the facility. This single solution resulted in greatly decreased programming and implementation time. Results Publishing real time data on the plant floor for both machine and factory-wide communications reduced downtime and increased productivity. This manufacturer stated that with these new efficiencies, the InView displays would pay for themselves in less than a year.
46
graphical user interface integrated utility for setting up InView communication modules application download capabilities
s s
Display and Network Management InView messaging software now uses a new graphical user interface (GUI) to enhance management of InView displays and the networks where they reside. The new GUI is divided into three areas: displays, message files, and message file details. This division allows the creation of messaging applications for multiple displays, with multiple message files consisting of multiple messages. The new layout provides better display control and easier changes and updates; instead of multiple files for each display, InView software now allows a single file for all displays. Allen-Bradley Electronic Operator Interface >> InView
WYSIWYG (What You See Is What You Get) Editor The new WYSIWYG editor allows users to see exactly what the InView will display as the message is created. The WYSIWYG shows fonts, colors, page breaks, and line breaks on a simulated LED matrix display. The editor also offers easy change from one message to the next affording efficient creation and editing of large messaging applications. In addition, the WYSIWYG editor provides message flashing, which is perfect for alarms and alerts.
Communication Module Setup Utility InView Messaging Software has a communication utility integrated within the new environment, allowing the user to easily configure and establish communications with displays equipped with InView communication modules. This feature quickly starts the display communication via DH+, DH-485, Remote I/O, DeviceNet, ControlNet, and EtherNet/IP.
Display Report Generation Capabilities The new InView software can create custom message file reports. These reports can be especially effective for display management and for creating hard copies of all messages within a message file. The reports can be tailored so the output matches the data needed.
Application Download Over Networks (Legacy and NetLinx) InView Messaging Software now includes the ability to download a new messaging application over your existing networks: Remote I/O, DH+, DH-485, ControlNet, DeviceNet, and EtherNet/IP. This greatly improves your flexibility and reduces system downtime. This, in conjunction with the InView communication modules, will integrate into your system seamlessly, creating the most effective messaging system available today.
47
Industrial Networks
Allen-Bradley Electronic Operator Interface >> InView
PC Ethernet TCP/IP
Reduce system costs by connecting an InView P9 to both your office Ethernet network and your factory control network at the same time with a single display - an Allen-Bradley InView exclusive feature. Reduce your application development or maintenance time by customizing your embedded variables. With the maximum of 128-character alphanumeric variable as well as the standard variable features, users can change part numbers on the fly by embedding into the displays message. Enhance your factory communications with user-configurable characters. This means you can continue to use your manufacturing symbols established for use with older bingo-type boards while enhancing your total factory communications. And InView character support now has no limitations, which means any font file can be used or created for use on the P9 displays.
48
InView Message Display Specifications - For catalog number selection, refer to page 75.
Catalog Number
D I S P L A Y LED matrix: Red 12 x 2 in (30 x 5 cm) 120 x 7 pixels 0.1 in (2.54 mm) 2 2 line/0.7 in (17.78 mm)/20 LED matrix: Red (R) or Tri-Color (C) 36 x 4.8 in (81.4 x 12.2 cm) 72 x 4.8 in (182 x 12.2 cm) 2 120 x 16 or 240 x 16 pixels 0.3 in (7.62 mm) 1 or 2 1 line/4.8 in (121.92 mm)/12 or 24 2 line/2.1 in (53.34 mm)/201 or 402
1 2 1
2706-P22R
2706-P72CN21 2706-P74CN22
2706-P92C1 2706-P94C2
Display Type Display Size (W x H) Display Array Center to Center Pixel Spacing (Pitch) Number of Lines Lines of Text/Character Height/Minimum Characters per Line
LED matrix: Tri-Color (C) 36 x 7.2 in (91.4 x 18.3 cm) 60 x 7.2 in (152.4 x 18.3 cm) 2
1
LED matrix: Tri-Color 36 x 9.6 in (91.4 x 24.4 cm) 72 x 9.6 in (182.9 x 24.4 cm) 120 x 32 or 240 x 32 pixels 0.3 in (7.62 mm) 1 to 5
120 x 24 or 200 x 24 pixels 0.3 in (7.62 mm) 1 to 4 1 line/7.2 in (182.88 mm)/12 or 20 2 line/3.0 in (76.2 mm)/201 or 332 3 line/2.1 in (53.34 mm)/201 or 332 4 line/1.5 in (38.1 mm)/241 or 402
1 2
1 line/9.6 in (243.84 mm)/13 or 26 2 line/4.5 in(114.3 mm)/13 or 26 3 line/3.0 in (76.2 mm)/13 or 26 4 line/2.1 in (53.34 mm)/20 or 40 5 line/1.5 in (38.1 mm)/24 or 48 Standard and Extended ASCII 450 ft (137 m)
Standard and Extended ASCII 25 feet (7.6 m) C A L & 24V dc 0 55C (32 131F) 5 95% noncondensing NEMA 4 and 4X (Indoor Use Only) UL, CE, C-Tick 1.87 lbs (.85 kg) 4.38 x 2.43 x 14.3 in (11 x 6 x 36 cm) E N V
Standard and Extended ASCII 350 ft (100 m) A L 120-240V ac; 50/60 Hz 0 50C (32 122F) 5 95% noncondensing NEMA 4, 4X ETL, CE marked 60 lbs (27.2 kg) or 80 lbs (36.3 kg) 42.25 x 6.0 x 13.75 in 1 (107.32 x 15.24 x 34.93 cm) 66.25 x 6.0 x 13.75 in 2 (168.28 x 15.24 x 34.93 cm)
Input Voltage Operating Temperature Humidity Ratings Certifications Enclosure Approximate Weight Enclosure Dimensions (W x D x H)
120-240V ac; 50/60 Hz 0 50C (32 122F) 5 95% noncondensing NEMA 12 ETL, CE marked 28 lbs (12.7 kg) or 50 lbs (22.7 kg) 40.38 x 5.5 x 7.88 in1 (102.57 x 13.97 x 20.0 cm) 76.38 x 5.5 x 7.88 in 2 (194.0 x 13.97 x 20.0 cm) N S (SEE
120-240V ac; 50/60 Hz 0 50C (32 120F) 5 95% noncondensing NEMA 12/13 (Indoor Use Only) UL, CE, C-Tick 70 lbs (32 kg) or 140 lbs (64 kg) 15.9 x 5.25 x 41.19 in 1 (40 x 13x 105 cm) 15.9 x 5.25 x 77.2 2 (14 x 13 x 196 cm)
C ATA L O G N U M B E R S E C T I O N F O R C O M M U N I C AT I O N M O D U L E C ATA L O G N U M B E R S )
Remote I/O, DH-485, DH Plus, DeviceNet, ControlNet, Ethernet DIN rail External 24 V A or later Back-mounted From Display C or later Internal From Display C or later Internal From Display C or later
49
V ERSAV IEW
Industrial Computers and Monitors
VersaView Industrial Computers and Monitors are ruggedly built to withstand the conditions of factory environments and have been independently tested to meet and exceed rated specifications. The VersaView family offers you more models than ever, more power to meet your performance needs, and more benefits and enhancements for you to like.
CASEin point
VersaView Helps Keep Operation Up and Running
Challenge A mining operation's 30-year-old control system provided no operational information, required dredging to be done manually, and was not aligned with the classifying plant. Solution A VersaView 200R non-display industrial computer running RSView and VersaView 1700M industrial monitor with touch screen was installed in the classifying plant, communicating with an SLC 5/03. The computer and monitor allow operators to oversee all aspects of the operation including plant processes and production reports, make changes remotely, and collect production data. Results The new system warns operators of potential problems and allows those problems to be fixed without interruption to the mining. The complete system saves approximately $100,000 per year in downtime and manpower.
50
More Models
The family of VersaView products continues to expand in order to meet an even broader range of industrial applications. The newest additions include:
s
Immediate Exchange
In the event your computer or monitor fails, you get an immediate exchange. A simple request through your Allen-Bradley distributor takes care of it - no need to wait weeks for a repair.
20.1-inch panel or rack-mount TFT monitor, an ideal replacement for the aging 20-inch CRT displays 12-inch TFT workstation, ideally suited to applications that require a high-performance computer with integrated display and full-function configurable keypad 15-inch TFT integrated display computer for hazardous locations where explosive gases may be present. It is rated for operation in Class 1 Division 2 classified environments
More Power
VersaView computers continue to be upgraded with the latest technology without the worry of cost increases. For instance, the 6181P integrated display computers have all benefited from CPU, RAM, HDD and motherboard enhancements, and many other VersaView models have received CPU, RAM and HDD enhancements.
How big should my hard drive be? Whats the latest and greatest processor on the market? What operating system and software should I use?
More To Like
Customers continue to value the fact that VersaView products make it easy for them to purchase computers for their industrial applications. A Fortune 500 customer in the automotive industry says: I know that I can get the latest technology computers at the lowest price on the web and save a few dollars in purchase price. All this is meaningless when my manufacturing is down and we are losing thousands of dollars because I cannot get the support I need. That is why I take a look at the services associated with the product throughout its life cycle when purchasing my computer and monitor products. Rockwell Automation offers a numbers of services that help you purchase, maintain and support your industrial computer installations anywhere in the world, at any stage in their life cycle.
VersaView Industrial Computers and Monitors take the guesswork out of product selection. They are pre-packaged with the options you need for virtually any industrial application. And this means simplified ordering - no more catalog numbers to configure.
MySupport
If you need or want to be kept up-to-date on the latest changes as they happen, MySupport gives you the ability to personalize the Rockwell Automation Support Services Web Site for your product interest. Once you complete a brief profile, MySupport sends you an email with links to technotes, software updates, and firmware updates for the products that are of interest to you. With MySupport, the information you want is delivered to you, so that you can stay on top of the latest releases.
Technology Management
Technology is managed for you, inside the box. VersaView computer components are chosen to ensure a balance of performance and longevity while meeting all industrial specifications. You can order the same part number time after time, with the assurance that you will receive the latest technology offered by Rockwell Automation.
1200P
(6181P) Description D I S P L A Y Display Type & Size Resolution Touch Screen Option S Y S T E M Expansion Slots Processor Types* Bezel Types RAM* Hard Drive Removable Media* I/O Operating Systems E L E C T R Power Requirements Operating Temperature Vibration Operating Shock Operating Ratings Certifications Industrial Computer with Flat Panel Display 12.1-inch (307.34 mm) Color TFT 800 x 600, 256K colors C O M P O N E N T S 2 half-length PCI, 1 compact flash (Type 2)
1500P
(6181P) Industrial Computer with Flat Panel Display 15-inch (381mm) Color TFT 1024 x 768 Resistive Antiglare
1700P
(6181P) Industrial Computer with Flat Panel Display 17-inch (431.8 mm) Color TFT 1284 x 1024, 24-bit color
1 PCI Half Length, 1 Compact Flash Standard: Pentium 4 Celeron 2.0 GHz, Performance: Pentium 4 2.0 GHz Aluminum Aluminum or Stainless Steel Standard: 256 MB; Performance: 512 MB (DDR) 40 GB Standard: slim Floppy Drive, slim CD-ROM Drive Performance: slim Floppy Drive, slim DVD-ROM CDRW Drive 3 Serial ports, 2 PS/2 ports, 1 Parallel port, 2 USB 2.0 ports, 1 10/100M Ethernet port, 1 video port, audio line in/out and microphone Windows 95/98, Windows 2000, Windows XP, Windows NT 4.0, QNX, Linux C A L & E N V I R O N M E N T A L 85264V ac, autoranging; 4763 Hz 0 50C (32 122 F) 0.006 in p-p, 1057 Hz, 1g peak, 57150 Hz 0.006 in p-p, 1057 Hz, 1.0g peak, 57500 Hz 15g (1/2 sine, 11 m) NEMA Types 1/12/4X/4, IP66 C-UL Certified, UL Recognized Component, CE marked, C-Tick
M E C H A N I C A L Mounting Options Dimensions Overall (HxWxD) 279 x 349.3 x 147.6 mm (10.99 x 13.75 x 6.93 in)
* Contact your local Allen-Bradley representative or authorized distributor for the most current features and specifications, or visit www.ab.com/versaview
VersaView
VersaView
VersaView
VersaView
1200M
(6186M) Description D I S P L A Display Type & Size Industrial Flat Panel Monitor Y 12.1-inch (307.34 mm) Color Active Matrix TFT 246 x 184 mm (9.7 x 9.2 in) Aluminum 800 x 600 (native mode), 256K colors
1500M
(6186M) Industrial Flat Panel Monitor
1700M
(6186M) Industrial Flat Panel Monitor
2000M
(6186M) Industrial Flat Panel Monitor 20.1-inch Color TFT 408 x 306 mm (16 x 12 in) 1600 x 1200 (native mode 16.7M colors
Nominal Display Area (HxW) Bezel Types Resolution Luminance (typical) Backlight
30,000 hours CCFT tubes 60,000 h (mean for 12 brightness point) (for 1/2 brightness) Touch Screen Option Resistive anti-glare touch screen Resistive or Capacitive anti-glare touch screen Resistive Antiglare Controls and Indicators Rear Controls: Automatic Screen Setup (OSD), Brightness, Contrast, Horizontal Position, Vertical Position, Image Lock, Color Balance, and Video Information. Power On and Sync detected Video Input HD-15; 5-BNC connector HD-15 or DVI; 5-BNC support through cable adapter HD-15 or DVI; 5-BNC connector support through cable adapter support through cable adapter Operating Systems Windows 95/98, Windows 2000, Windows XP, Windows NT 4.0, QNX, Linux E L E C T R I C A L & E N V I R O N M E N T A L Power Requirements AC: 90264V ac, autoranging; AC: 90264V ac, autoranging; 4763 Hz, DC: 12V dc or 24V dc 4763 Hz, DC: 12V dc Operating Temperature 0 50C (32 122F) Vibration Operating 0.015 in p-p, 1053 Hz, 2.0g peak, 53640 Hz sine Shock Operating 20g (1/2 sine, 11 ms) Ratings NEMA Types 1/12/4/4X IP66, Series B Class 1 Div 2 Certifications C-UL Certified, UL Recognized Component, CE marked, C-Tick M E C H A N I C A L Mounting Options Panel, Rack, Bench/Tabletop, and Wall Mounting Dimensions Overall 260 x 340 x 56 mm 309 x 410 x 58 mm 356 x 452 x 55 mm 399 x 483 x 74 mm (HxWxD) (10.24 x 13.39 x 2.21 in) (12.2 x 16.14 x 2.28 in) (14.02 x 17.80 x 2.16 in) (15.7 x 19.0 x 2.9 in)
15.0-inch (381mm) 17.0-inch insert (442.0 mm) Color Active Matrix TFT Color Active Matrix TFT 305 x 229 mm (12 x 9 in) 338 x 270 mm (13.3 x 10.7 in) Aluminum or Stainless Steel 1024 x 768 (native mode), 1280 x 1024 (native mode) 16.7 million colors 16.7 million colors 250 cd/m2 (Nits) 50,000 hours (mean for 12 brightness point)
52
VersaView
VersaView
VersaView
200R
(6155R) Description D I S P L A Y Display Type & Size Resolution Touch Screen Option S Y S T E M Expansion Slots Industrial Non-Display Computer
700R
(6155R) Industrial Non-Display Computer Requires External Monitor N/A N/A
1400R
(6155R) Industrial Non-Display Computer
3 Half Length PCI, 2 Full Length ISA slots, 3 Half Length PCI, 4 Full Length PCI 1 compact flash connector (internal) 2 Half Length ISA,3 Full Length ISA Processor Types* Standard: Pentium IV 2.0 GHz Celeron; Performance: Pentium IV 2.0 GHz RAM* Standard: 256 MB; Performance: 512 MB (DIMM) Hard Drive 80 GB Removable Media* Standard: 3.5 in Floppy Drive, CD-ROM Drive Performance: 3.5 in Floppy Drive, DVD CD-RW Drive I/O 1 Serial port, 1 PS/2 port (keyboard/mouse), 2 Serial ports, 1 PS/2 port (keyboard/mouse), 1 Parallel port, 1 Parallel port, 1 10/100M Ethernet port, 1 VGA port, 1 10/100M Ethernet port, 1 VGA port, 1 USB port, 2 USB ports, Audio Line In, Line Out, Mic 1 Compact Flash connector, 1 Audio Out Operating Systems Windows 95/98, Windows 2000, Windows XP, Windows NT 4.0, QNX, Linux E L E C T R I C A L & E N V I R O N M E N T A L Power Requirements 90264V ac, autoranging; 4763 Hz Operating Temperature 0 50C (41 122 F) Vibration Operating 0.006 in p-p, 1057 Hz, 1.0g peak, 57500 Hz Shock Operating 15g (1/2 sine, 11 ms) Ratings NEMA Type 1 Certifications C-UL Certified, UL Recognized Component, CE marked, C-Tick M E C H A N I C A L Mounting Options DIN Rail Mount Machine Mount Rack Mount Dimensions Overall 115.4 x 172.2 x 152 mm 258 x 192 x 431.3 mm 176 x 428 x 560 mm (HxWxD) (4.54 x 6.78 x 5.98 in) (10.16 x 7.56 x 16.98 in) (6.93 x 18.97 x 22.05 in) * Contact your local Allen-Bradley representative or authorized distributor for the most current features and specifications, or visit www.ab.com/versaview
P O N E N T S 1 PCMCIA slot (Performance models) 1 GHZ VIA C3 Standard: 256 MB; Performance: 512 MB 40 GB None
VersaView
VersaView
1200W
(6180W) Description D I S P L A Y Display Type & Size Resolution Touch Screen Option S Y S T E M Expansion Slots Processor Types* RAM* Hard Drive Removable Media* I/O Industrial Workstation with Flat Panel Display and Keypad 12.1-inch Color TFT 800 x 600 Resistive Antiglare O N E N T S
1500W
(6180W) Industrial Workstation with Flat Panel Display and Keypad 15-inch Color TFT 1024 x 768, 24-bit color Resistive Analog Touch screen
2 Half Length PCI, 2 Full Length ISA slots Standard: 2.0 GHz Pentium IV Celeron; Performance: 2.0 GHz Pentium IV Standard: 256 MB; Performance: 512 MB (DIMM) Standard and Performance: 80 GB Standard: 3.5 in Floppy Drive, CD-ROM Drive; Performance: 3.5 in Floppy Drive, DVD CD-RW Drive 1 Serial port, 1 Parallel port, 2 USB 1.1 ports, 1 10/100 M Ethernet Port, 1 Video Port Windows 95/98, Windows 2000, Windows XP, Windows NT 4.0, QNX, Linux & E N V I R O N M E N T A L 90...264 Vac, 19...32 Vdc 0 50C (32 122 F) 0 50C (41 122 F) 1 g peak, 57...500 Hz 0.006 in p-p, 1057 Hz, 1.0g peak, 57500 Hz 15 g (1/2 sine, 11 ms) IP66 NEMA Type 4/12, IP66 C-UL Certified, UL Recognized Component, CE marked, C-Tick Panel Mount 340 x 486 x 220 mm (13.40 x 19.14 x 9.30 in)
Operating Systems E L E C T R I C A L Power Requirements Operating Temperature Vibration Operating Shock Operating Ratings Certifications M E C H A N I C A L Mounting Options Panel Mount Dimensions Overall (HxWxD) 311 x 483 x 297 mm (12.25 x 19.01 x 11.7 in)
53
Industrial Computers
A
VersaView Computers (front) VersaView Computers (side)
E B C D F
Monitors
B C
A A C
Non-display Computers
A B B
54
55
CASEin point
Pharmaceutical Manufacturer Benefits from Consistent Operator Environment
Challenge A large global pharmaceutical manufacturer needed machine-level and supervisory-level HMI, standardizing with consistent operator environment. In its old system, it used multiple software packages requiring completely different developing tools each with its own user interface, navigation tools and learning curve. Solution With RSView Enterprise Series, all of the software products in the suite are built on the same integrated, scalable architecture. RSView Studio, a common development environment, supports developing both machine-level and supervisory-level HMI applications. While operators manage machine-level data from dedicated operator terminals and industrial computers on the plant floor, maintenance engineers can easily monitor the same machine-level from their supervisory stations in remote locations-without having to create any displays or tags. Results This manufacturer has realized reduced development time resulting in lower development costs. The new common development environment provides consistent operator interface as well as navigational features across multiple platforms. And it is now easy to re-use machine-level applications within supervisory-level projects.
56
RSView Studio
Both RSView Supervisory Edition and RSView Machine Edition share a common design environment called RSView Studio, which allows users to create applications in a single design environment. RSView Studio supports editing and reusing projects for improved portability between embedded machine and supervisory HMI systems. In a conventional environment, developing both machine-level and supervisory-level HMI applications requires using completely different development tools, each with its own user interface, navigation tools, and learning curve. Sharing graphic displays, tags, and other project elements between the two environments is difficult. Although graphics can often be imported, neither tags nor commands convert cleanly, leaving much tedious work still to do. With RSView Studio, you can: s Configure a single operator station or configure an entire distributed application from one location
s
With RSView Enterprise Series, all of the software products in the suite are built on the same integrated, scalable architecture. Now, application developers can import entire machine-level applications into supervisory-level applications, or drag individual components and drop them right into supervisory projects, saving development time and reducing engineering and training costs. RSView Studio configures RSView Supervisory Edition and RSView Machine Edition. Users can share whole or parts of applications between RSView Machine Edition and RSView Supervisory Edition, cutting the development time, and reducing the cost of application development. Users can also import PanelView applications into RSView Machine Edition and RSView32 applications into RSView Supervisory Edition, protecting their current HMI investments. Benefits s Reduces development time
s
Access tags from OPC servers throughout the system via a tag browser that presents direct PLC tags and HMI tags in a logical hierarchy Remotely configure RSLinx and RSView SE servers Create displays using a full-featured Graphics Editor
Offers common development environment with consistent operator interface and navigation features across multiple platforms Makes it easy to reuse machine-level applications within supervisory-level projects
s s
Create displays using full-featured Graphics Editor Use powerful editing tools to draw, flip, rotate, arrange, align, group, copy, and paste Animate objects including fill, position, visibility, rotation, size, color and slider
RSView Studio includes a string import/export wizard to help you deploy applications in a number of different languages. You simply export the text strings that operators see at runtime to an editable file that can be translated into another language. When the strings have been translated, you import them into the application, where they can take the place of the original text strings.
s
Use the Object Explorer to view hierarchy of display objects Easily scale displays when changing screen resolution or terminal sizes.
Animate motion by clicking and dragging with Object Smart Path Reuse objects with Graphics Library (has hundreds of objects to drag and drop)
Import/Export Capabilitites RSView Studio makes it easy to automatically create displays or make changes to existing displays. Using the Graphics XML Import/Export feature, graphics displays and objects can be exported to an XML file where they can be modified using a standard editor. When the modified file is imported back into RSView Studio, the graphics displays are automatically updated. You can also create new displays or add objects to existing displays when importing an XML file. RSView ME also provides the ability to import and export the alarm configuration data within an application to an XML file.
Use the Property Panel to edit single or multiple object attributes Import graphics from other software packages
57
RSView Machine Edition is a machine-level HMI product that supports both open and dedicated operator interface solutions. It provides a consistent operator interface across multiple platforms (including Microsoft Windows CE, Windows 2000/XP, and PanelView Plus solutions), and is ideal for monitoring and controlling individual machines or small processes. Components included with RSView Machine Edition are RSView Studio and RSView Machine Edition Station.
RSView Machine Edition is a machine-level HMI product for developing and supporting PC-based and embedded operator interface solutions. It is designed as a monitoring and control system for individual machines and small processes. Rockwell Software >> RSView Machine Edition RSView Machine Edition is part of the RSView Enterprise Series, which offers a scalable HMI architecture. RSView Machine Edition includes RSView Studio, a development system used for creating machine-level projects, and RSView ME Station, used for running the projects created on the development system. The RSView Studio development system runs on Microsoft Windows XP and Windows 2000 operating systems. The RSView ME Station system runs on Windows CE, Windows XP, and Windows 2000 operating systems. Flexible runtime options include Allen-Bradley PanelView Plus dedicated operator terminals, Allen-Bradley VersaView CE and VersaView industrial computers, and desktop computers running Windows operating systems. Scale machine-level HMI applications across multiple platforms RSView Machine Edition expands the scope of traditional machine-level HMI development from dedicated devices to a much broader scale that includes open Windows CE solutions and Windows desktop operating systems. With RSView Machine Edition software, a single HMI application can be created once in RSView Studio, downloaded to a variety of machine-level hardware platforms and operating systems, and then run without any modifications. To maintain the project, simply open it in RSView Studio, edit, and download again. Streamline HMI development with a common editor RSView Enterprise Series also includes RSView Supervisory Edition, a highly scalable HMI that supports multi-server distributed systems. With RSView Enterprise Series, all of the software products in the suite are built on the same integrated, scalable architecture and share a common look and feel and common navigation features. RSView Studio, a common development environment, supports developing both machine-level and supervisory-level HMI applications. Entire machine-level applications can be imported into supervisory-level applications, and individual components can be dragged and dropped right into supervisory projects. Choose preferred connectivity with Rockwell Automation controllers RSView Machine Edition is the ideal machine-level HMI product to use with other Rockwell Automation products. RSLinx Enterprise communications offers native, optimized communications to Logix platforms. Enabled by FactoryTalk Directory, RSView Machine Edition allows browsing a local directory for RSLogix tag addresses and directly accessing controller tags. RSView Machine Edition features preferred connectivity to Rockwell Automation products such as ControlLogix, PLC-5, and SLC controllers. RSView Machine Edition offers both single (point to point) and fully networked connections and can be configured to communicate on multiple networks, with up to four channels supported simultaneously. RSView Machine Edition supports KEPserver Enterprise software, which provides serial and Ethernet OPC servers that allow communication between many third-party industrial devices and RSView Machine Edition. Share data with other FactoryTalk-enabled products Within a local directory on a standalone computer, RSView Machine Edition takes advantage of FactoryTalk, an underlying integrated platform.
58
FactoryTalk Directory offers a common address book of tags, directly referenced from programmable logic controllers. Tags defined in RSLogix programming software and referenced via RSLinx communications software are automatically available for browsing and access in a local directory. With FactoryTalk Directory, tags need not be recreated, imported, or exported in a separate tag database. Within RSView Studio, simply browse the local directory. As tag values and properties change, the changes update automatically wherever they are used within RSView Machine Edition applications.
Archive operator activity and system changes via FactoryTalk Diagnostics FactoryTalk Diagnostics records information about various types of system activity, including:
s s s s s
Command and macro usage Operator comments System messages and errors Communication network errors Tag read and write activity
You can view diagnostic messages about system activity while developing applications and at runtime. Complying with industry and government regulations often requires capturing and archiving operator actions and changes that occur to a running system. To track and record these types of changes, RSView Machine Edition takes advantage of a built-in FactoryTalk Diagnostics capability, which automatically routes security information and messages about system transactions to a choice of logging destinations, including local (Windows XP and Windows 2000 only) and remote logs.
Validate user access with Windows 2000 Security options RSView Machine Edition allows creating different private user accounts with separate runtime access privileges. In RSView Studio, configure individual private accounts, which include user name, password, login and logout macros, and a list of security codes associated with the account. In the RSView ME Station system, users can open only the graphic displays that they are authorized to open, based on the security codes defined in the user accounts. RSView ME also enables DeskLock 2000 (Windows XP, Windows 2000 only), which prevents users from accessing the desktop at runtime. To facilitate regulatory compliance, RSView ME can also integrate with the Windows 2000 Security Authentication system. The system supports either a Private user list, which is specific to RSView Machine Edition, or a system-wide Windows user and group list. RSView Machine Edition usernames and passwords are synchronized with Windows 2000 domain passwords. Usernames and passwords entered from the PanelView Plus, VersaView CE, and Windows 2000 ME platforms are validated against Windows 2000 security. In addition, the Windows Security system manages user accounts, including enforcing unique passwords, automatically logging out accounts after unsuccessful logons, and enforcing password changes after a designated amount of time.
Migrate PanelView projects to enhanced hardware platforms An automated wizard allows importing PanelView Standard and PanelView 'e' projects into RSView Machine Edition applications via RSView Studio. The process successfully retains most of a PanelView project, including graphic displays and most animated objects, text, tags, alarm messages, and local and global messages. After importing an older PanelView project into RSView Studio, edit it and download it to any enhanced hardware platform, including PanelView Plus dedicated operator terminals, VersaView CE and VersaView industrial computers, and desktop computers running Windows operating systems.
59
Configure and monitor alarm conditions The RSView alarm system quickly alerts operators to conditions requiring immediate action. Use the Alarm Setup Editor to configure alarm conditions. When an alarm condition occurs during runtime, the system can pop up a predefined display, sound an alarm signal (Windows XP/2000 only), or send the alarm to a printer. Alarm system features include: Word alarm triggers based on analog tags, digital tags, or expressions s Bit and least-significant bit alarm triggers s Ability to acknowledge, silence, and clear alarms s Ability to sort alarms by machine or machine area
s
Log tag data and display it in a trend Configure a data log model to define up to 100 analog or digital tags to log data for, along with how and where the data is logged. Log tag data as tag values change or periodically, for example, every minute. Data can be logged on the runtime computer, on another computer in the network, or on a PC card (for PanelView Plus and Windows CE terminal applications).
Machine-level advanced objects RSView Machine Edition comes with many advanced objects, including: Push buttons, macro buttons, ramp buttons Numeric display and numeric input enable s Numeric input cursor point s Numeric and string pop-up scratchpads and keypads s String display and entry enable s Local message display s Alarm, diagnostics log, and information message objects s Time and date objects s Image object s Display navigation objects s Navigation keys s Print display, Login and Logout, Shutdown buttons s List, symbol, and multi-state indicators s List selectors s Gauges, bar graphs, scales, and trends s Alarm list and sort alarms objects s Alarm banner and clear alarm banner objects s Alarm status list and alarm status mode objects s Reset alarm status, print alarm status, print alarm history objects s Close display and set tag
s s
To display historical data that has been logged, use trend charts. At runtime, when an operator opens a graphic display containing a trend object, the chart displays values from the data log model that is running. Trend charts can also display current tag values. Provide operators with message information To give operators information in a specific graphic display while the display is open, use the local messages feature to create message files used by the Local Message display object. Each message file contains a list of up to 10,000 messages and associated trigger values. During runtime, the Local Message display object displays a message determined by a tag value from the list of defined messages. The message appears in the display object until the tags value changes. To give operators information no matter which display is open, use information messages. Each message file contains a list of messages and corresponding trigger values. These messages can pop up to keep operators informed when certain events or processes occur while a project is running
60
with AIC with AIC to AIC+ to to AIC+ to Ch. 0 1/5 Ch. 0 1/5 Ch. 0 Ch. 0
Ch. 0
n/a PLC-5C
yes 4
n/a
PLC-5E, or 1771-SN
yes 2/ 4/ 7
1. For isolation purposes if not used on the same power supply. 2. Symbolic (CIP) addressing. Example: Address = TankLevel. 3. Ethernet is supported through the PanelView Plus serial port with 1761-ENI. Check availability of direct Ethernet controller with an ENI. 4. RS-485 to AIC bridged to AIC+ to device. 5. RS-232 to AIC bridged to a AIC+ to device. 6. L35E
n/a
n/a
no
PLC-5C
EtherNet/IP
n/a3
n/a
n/a3
n/a3
yes
yes (2/4/7)
For isolation purposes if not on the same power supply Legacy mode. Example: address = N7:0 3 Symbolic (CIP) addressing. Example: address = Tank level
1 2
61
RSView Supervisory Edition gives you critical real-time control, access to crucial manufacturing information, and unmatched connectivity, allowing you to reduce development, integration, and maintenance time, so you can reduce your time to market.
RSView Supervisory Editions revolutionary architecture allows plant information to be available to any users at any time! RSView SE distributed servers provide local control for real-time operations, while making crucial information available to supervisors and executives. Since each RSView SE client can view information from any and all RSView SE servers, each user receives all the information he needs to perform his job. While operators are viewing information pertinent to their areas of the process, supervisors and executives are viewing the information they need to make important decisions about their manufacturing process. Save development time with RSView Studio Reduce development time and engineering and training costs by creating applications with the RSView Studio development system for RSView Enterprise Series. RSView Studio supports editing and re-use of RSView Machine Edition and RSView SE projects for portability between embedded machine and supervisory HMI systems. Entire machine-level applications can be migrated to supervisory level applications, or single components of an application may be re-used by simply dragging and dropping the components between applications. Because RSView Machine Edition and RSView Supervisory Edition share this common editing environment, applications can be easily integrated on the plant floor to provide levels of control and information to those who need it. RSView ME Stations can provide local operator control, while the plant supervisors, managers, and key decision makers can access all of the stations in a facility via RSView Supervisory Edition system.
62
Optimize plant communications RSView SE, via FactoryTalk, has enterprise-wide access to realtime manufacturing information, enabled by FactoryTalk LiveData. FactoryTalk LiveData enhances the widely adopted OPC specification and supports XML, optimizing communications and allowing disparate systems to speak the same language. Real-time manufacturing data, typically coming from OPC servers and Allen-Bradley programmable controllers, is available immediately to all participating FactoryTalk-enabled products and systems. So FactoryTalk can provide operators with reliable, real-time manufacturing data while providing machine status reports, operating diagnostics, and audit trails to plant managers and executives. FactoryTalk LiveData also provides redundancy for OPC servers so you dont lose critical control data. Get connected with FactoryTalk RSView Supervisory Edition is built on Rockwell Softwares FactoryTalk. FactoryTalk is a collaborative framework that allows everyone in a manufacturing enterprise to share real-time information, and communicate effectively. Shop floor operators and engineers can keep lines moving more smoothly, plant managers can increase production efficiency, and executives can make well-informed decisions. Sharing the right information with the right people wherever they happen to be thats the promise of FactoryTalk. FactoryTalk-enabled products share a common address book of factory resources, including data tags, HMI displays, and other plant-floor resources, enabled by FactoryTalk Directory. FactoryTalk Directory is not a single, common database. Instead, it is a directory that provides searchable references to resources stored anywhere across a distributed system. This directory provides you with benefits of a common database without the downside of a possible single point of failure. This means that tags and structures only need to be created once! Directly access tag information Once you have defined your tags in your controllers, RSView SE accesses those tags directly via your RSLinx and OPC 2.0 data servers. FactoryTalk provides an aggregate directory of all of the tags and structured information in your system, allowing you to browse all of the tags in a single directory of information in your entire system. Those tags are available for use not only to RSView SE, but to any FactoryTalk client. So, when you add tags, structures or controllers to a system, all of the FactoryTalk clients, such as RSView SE clients, RSView SE servers, and RSSQL, will be able to access the new data in the system automatically. This means that you do not have to update multiple tag databases to reflect changes to the system. Provide an audit trail RSView SE can log operator information to local RSView SE logs, external ODBC data sources, or to a system-wide audit log via FactoryTalk Audit. FactoryTalk Audit makes it easy to maintain a comprehensive, central record of all changes made to a manufacturing system. This eliminates the need for multiple tracking systems and multiple databases. FactoryTalk enabled products such as RSView, RSLinx, and RSLogix all generate audit messages when users log into the system, change data configurations, or change I/O configurations. FactoryTalk Audit routes these audit messages from all participating products to a central audit log for storage and analysis. Don't lose control RSView Supervisory Edition keeps you in control with redundancy. RSView SE clients will continue to update and operate if communication is lost with your RSLinx server, OPC data server, or RSView SE servers by failing over to backup servers. Scale your view Key to RSView Supervisory Edition is the ability to scale the application to your needs. Applications can be applied to a stand-alone environment, or multiple servers and clients can be deployed for larger applications where information needs to be shared across areas such as lines, cells, or plants. RSView SEs hierarchical application architecture and logical area names allow the effortless addition or integration of new areas. Entire lines, processes, or factories can be duplicated without having to rename tags or displays. Configure your application from anywhere RSView SEs editing environment allows application development across multiple servers from a single location. It also gives multiple developers access to the same project at the same time. You can develop your application on one computer or all computers in the system. So, you can develop your application on your laptop, then when youre ready to deploy the system, you can move the components of the system to their field locationsright from your laptop!
Global, distributed alarming A complete set of graphical objects, drawing tools, and editing tools. Native graphics library and graphic import from third party graphic packages Animation including fill, position, visibility, rotation, size, color, and slider Data Logging to log tag values that can be displayed in the historical trend object Trending to monitor real-time and historical data Alarming to quickly alert operators to conditions requiring immediate action Logging of all operator activities Expressions to perform mathematical or logical calculations Parameter files to represent multiple machines or devices with a single graphic display Test Run simulation of runtime of display Object Explorer to quickly view the hierarchy of objects on a display Compatibility with Windows 2000, Windows XP, Windows 2000 Terminal Services, and Windows Server 2003. Automatic logout of operators after a user specified period of inactivity
s s
s s s
s s
64
RSView SE Station
RSView SE Station provides standalone, local, runtime functionality for monitoring control of individual processes or lines. RSView SE Station is designed to run on a single computer without requirements of a network or IIS. RSView SE Station is in essence an RSView SE server and an RSView SE client in one inseparable product to address a traditional standalone HMI application. Take communications to the next level RSView Supervisory Edition will be integrated with RSLinx Enterprise, the latest evolution in communication products for Rockwell Automation controllers. RSLinx Enterprise provides communication for Rockwell Automations ControlLogix platform for highly-available, and highly-distributed automation systems. RSLinx Enterprise is a true FactoryTalk data server, providing local and remote connectivity. RSLinx Enterprises configuration environment is integrated with RSView Studio, allowing users to configure data servers within RSView Studio.
Edit your local configuration with the new Communications tab, integrated with RSView SE.
Integration with
Benefits s Lower total cost of ownership of Rockwell Software applications
s
RSAutomation Desktop
RSAutomation Desktop includes built-in controls for managing complex industrial automation projects. A team can work together on a project concurrently without fear of overwriting each others work. Because the versioning system is tied into an underlying FactoryTalk Audit capability, messages about changes to any element of the project are available immediately across the entire automation system. RSAutomation Desktop provides a single application that hosts your automation projects. Multiple users can work on the same project, re-use work, and keep versions in check. RSAutomation Desktop provides integration of Rockwell Software products, third-party products as well as adding other system features to help you design and implement your automation projects. With different versions of various project elements, and with different people working on the same things, managing complex projects is difficult, time consuming, and error prone. With RSAutomation Desktop, every element in a project has a version number associated with it. To work with a project element, a developer checks it out from a common database. Other team members can view the project element but cannot edit it. When the project element is checked back in, the system assigns a new version number and generates an audit message that includes optional author comments, along with details about who made the change, what was changed, and when it was changed. The audit trail makes it easier to analyze project changes across time and restore a project back to any state.
Improved automation project quality by the elimination of manual operations Faster project completion through work reuse Eliminates conflicting edits and duplicated efforts from multiple project team members Comprehensive audit trail makes it easy to track who made changes to project elements, when, and why Allows restoring any historical version of an industrial automation project Makes messages about project changes available across an entire automation system
s s
65
RSView32
For the Clearest View of Your Enterprise
RSView32 is an integrated, component-based HMI software package for monitoring and controlling automation machines and processes. RSView32 expands your view with open technologies that provide unprecedented connectivity to other Rockwell Software products, Microsoft products, and third-party applications.
RSView32 was the first HMI software to take full advantage of leading-edge Microsoft technologies to: s Open graphic displays as OLE containers for ActiveX controls with thousands of third-party ActiveX controls to choose from, you can drop ready-made solutions right into your projects. s Develop an object model to expose portions of its core functionality, allowing RSView32 to easily interoperate with other component-based software products. s Integrate Microsoft Visual Basic for Applications (VBA) as a built-in programming language, allowing almost unlimited ways to customize and extend your RSView32 projects. s Support OPC standards as both a server and a client for fast, reliable communications with a wide variety of hardware devices from multiple vendors. s Implement Add-On Architecture (AOA) technology to expand RSView32s functionality and integrate new features into RSView32s core.
66
Tag-based: digital & analog; definable alarm severities, alarm log 20+ data log models; each with up to 10,000 tags; log to ODBC or dbf database TrendX 3.1 & native Security assigned to tags, graphic displays, macros, commands, OLE objects; local or Windows security Test run; macros; derived tags; event detector Tag-based pricing; multiple levels
Tag-based: digital & analog; definable alarm severities, alarm log 20 data log models per project; each with up to 10,000 tags; log to ODBC or proprietary database TrendX 4.0 Security assigned to tags, graphic displays, macros, commands, OLE objects; Windows security Test run; macros; derived tags; event detector Display-based pricing; multiple levels
State-based (from controller); alarm log 1 data log model; up to 100 tags; 300K records max; export to dbf TrendX 4.0 (subset) Display-based; local or Windows security Test run; macros Included with PanelView Plus, VersaView CE; or Display-based pricing; multiple levels for XP/2000 67
Trending Security
As systems become more complex, companies are recognizing the need to get beyond just moving information throughout the automation and business systems. That model simply transfers information from one layer to another, maintaining disparate silos of information and duplication of data and functionality. FactoryTalk is based on shared services and federated data and is the common platform that allows manufacturing applications to integrate seamlessly across the enterprise, providing information transparency for decision-making. Enabling technologies within FactoryTalk allow information to be defined once and shared across applications. Data can be centrally organized, so users can browse application data and services from a single point.
COMMUNICATE.
FactoryTalk transforms plant-foor data into useful information and delivers it to the people who need it, from maintenance engineers to enterprise planners. Previously, customers had two ways to connect plant information with business systems and integrate disparate data: componentbased systems or distributed control solutions. Components often seem like a low-cost option, but integration, customization, and testing can drive costs up substantially. Because components are not tightly integrated with each other, services like alarm detectors and tag databases can be duplicated in each component, creating duplicated information. Distributed Control Systems (DCS) offer a high level of initial integration, but are less flexible because they are tailored for continuous manufacturing processes. In addition, DCS systems are very expensive to acquire and maintain due to their highly specialized nature.
displays. Unlike a single database, FactoryTalk Directory provides searchable references to resources stored anywhere across an automation system, offering the benefits of central data storage without the risk of a single point of failure. The common address book of information allows data to exist in native locations, such as within controllers, graphics servers, and other types of servers in the system, but be referenced from anywhere. For example, components that need to access a tag database look up the database location and form a link to that information. The federated data model maintains information integrity because data is shared, not duplicated, among computers and software components in the system. Furthermore, should the central Directory fail, single points of failure are eliminated by caching Directory information on each computer.
INTEGRATE. COLLABORATE.
FactoryTalk allows defining plant-floor resources once, and then allows simultaneous access to those resources across system boundaries. With a federated data model within the automation layer, objects are created once and made accessible throughout the system. FactoryTalk-enabled products use FactoryTalk Directory to share a common address book, which automatically finds and provides access to plant-floor resources, such as data tags and HMI
68
FactoryTalk eliminates both functionality gaps and overlaps by providing common services (such as security, diagnostics, and access to real-time data), and by sharing plant resources (such as tags, displays, and alarms) throughout a production facility. The FactoryTalk platform is the only solution available today that uses these revolutionary concepts of federated data and shared services. This allows customers to decrease set up and maintenance costs through shared information, and realize a high level of integration and flexibility.
The FactoryTalk Automation Platform supports common services built into FactoryTalk-enabled software products from Rockwell Software such as RSView Machine Edition and RSView Supervisory Edition, and third-party vendors.
FactoryTalk Directory
FactoryTalk LiveData
FactoryTalk Audit
FactoryTalk Diagnostics
These technologies provide capabilities to help manufacturers share common factory resources, access information across the enterprise, and track global system changes.
FactoryTalk Directory
FactoryTalk-enabled products use FactoryTalk Directory to share a common address book, which automatically finds and provides access to control system objects, such as data tags and HMI displays. Unlike a single database, FactoryTalk Directory provides references to objects stored anywhere across an automation system, offering the benefits of central data storage without the risk of a single point of failure. Using this enabling technology, companies can build complex distributed systems in any location and later deploy the systems elsewhere by simply modifying computer names. Shared objects are then available to every participating FactoryTalk-enabled product across the entire automation system. Changes made to the automation system automatically update across all participants in a FactoryTalk enabled application.
FactoryTalk Audit
FactoryTalk Audit makes it easy to maintain a comprehensive, central record of all changes made throughout the manufacturing system. In a FactoryTalk-enabled automation system, Rockwell Software products monitor system changes and generate detailed audit messages throughout an enterprise. Additionally, messages are routed to a central database where they are available for tracking and analysis. During the normal course of operations, FactoryTalk enabled products, such as RSLogix, generate audit messages when users log into the system, change data configurations, or change I/O configurations. Other areas of the system generate audit messages when recipes, logic programs, or batches are downloaded or configured, and when other normal operation activities cause changes to the system. All of these messages are routed from all participating products to a central audit log for storage and analysis.
FactoryTalk LiveData
FactoryTalk LiveData manages connections between FactoryTalk enabled products and data servers. It notifies clients when a connection is lost, automatically reconnects when servers are restored, and combines data from multiple controllers and servers into a single list of tags available to all clients. This results in faster real-time data transfer and more reliable, efficient connections to data servers. It also assists in redundancy support for data servers by automatically handling failure detection and failovers for all FactoryTalk-enabled products. When a FactoryTalk-enabled client, such as RSView or RSSql needs to access tags, a FactoryTalk Tag Browser opens. Behind the scenes, FactoryTalk aggregates tags from all data servers and makes them available through the FactoryTalk Directory. The FactoryTalk Tag Browser provides a view into the Directory, and allows browsing tags from RSLinx data servers, OPC data servers, and traditional HMI tags, all from one convenient window. FactoryTalk LiveData enables fault tolerance and redundancy capabilities to provide backup for RSView Supervisory Edition applications. HMI servers and data servers can be configured for redundancy, allowing clients to automatically detect a failed server, seamlessly switch to another designated server, and continue operating with minimal interruption and without operator intervention.
FactoryTalk Diagnostics
FactoryTalk Diagnostics collects and routes all activity, status, warning, and error messages generated by all FactoryTalk enabled components on a given computer to a common local log enabling users to diagnose problems on the computer in question. To help diagnose network-wide problems, FactoryTalk Diagnostics allows merging each computers log into a central, network-wide database for further analysis and/or archiving. FactoryTalk Diagnostics can route change information to a centralized RSMACC repository for auditing plant-wide maintenance information associated with change management and asset health. This is particularly important for companies required to maintain compliance with U.S. government regulations in the pharmaceutical and food and beverage industries. With built-in diagnostic capabilities, FactoryTalk enabled products can monitor system changes, generate detailed audit messages, and route messages to a central database, where they are available for tracking, analysis and reporting.
The FactoryTalk Automation Platform components are included when you purchase FactoryTalk-enabled products from Rockwell Software.
69
Communication Networks
Network Performance and Flexibility: Confidence and Stability Rockwell Automation HMI solutions take advantage of our NetLinx Open Network Architecture. NetLinx Open Network Architecture is based on the Common Industrial Protocol (CIP) which provides a common set of features and services for DeviceNet, ControlNet, and EtherNet/IP, resulting in a lower total cost of ownership. Users can easily manage information from shop floor to top floor and seamlessly integrate their complete system as they control, configure and collect data. This connectivity helps system integrators, OEMs and end users to cost-effectively assemble highly integrated applications that link HMI devices to the manufacturing process through NetLinx-based networks. In addition to the NetLinx-based networks, various HMI products support:
s Data Highway Plus Universal Remote I/O s DF1 DH-485 s Other open communications networks including Modbus s s
ControlNet
Robust, Deterministic, and Secure for the Most Challenging Applications ControlNet is an open network managed by ControlNet International, Ltd., an independent vendors organization. ControlNet is a real-time, control network that provides highspeed transport of both time-critical I/O data and messaging data, including upload/download of programming and configuration data and peer-to-peer messaging all in a single physical media link. ControlNet's highly efficient control and information data transfer capabilities significantly enhance I/O performance and peer-to-peer communication. ControlNet is highly deterministic because it has the ability to reliably predict when data will be delivered. ControlNet is also renowned for its repeatable nature which guarantees that transmit times are constant and unaffected by devices connecting to, or data leaving, the network. These are critical requirements for ensuring dependable, synchronized and coordinated real-time performance.
Communication Networks
1793-OB4P 1793-OB4P
COMM A A COMM
HEALTH HEALTH
0 3 0 3
COM COM 24V 24V
ControlNet DeviceNet EtherNet/IP ControlNet DeviceNet EtherNet/IP DeviceNet EtherNet/IP ControlNet DeviceNet EtherNet/IP ControlNet NetLinx Open Network Architecture EtherNet/IP ControlNet DeviceNet EtherNet/IP ControlNet DeviceNet
EtherNet/IP
Ethernet Technology for Industrial Control Applications EtherNet/IP, short for Ethernet Industrial Protocol, is an open industrial networking standard that takes advantage of commercial, off-the-shelf Ethernet communication chips and physical media. Because EtherNet/IP uses CIP, the same technology used on DeviceNet and ControlNet, you can control, configure and collect data while enjoying the benefits of both the standard Ethernet TCP/IP and the NetLinx Open Network Architecture. The cost per node for Ethernet devices is rapidly decreasing, and EtherNet/IP is a viable choice for many control applications. EtherNet/IP provides cost savings by offering a wide selection of vendors and products, and in training personnel. Since Ethernet technology is well-known, personnel often do not need additional training. Development tools are available on the Web at no cost and many developers offer products.
70
DeviceNet
Distribute and Troubleshoot Simple Devices DeviceNet is an open network managed by the Open DeviceNet Vendor Association. It offers an open, low-cost option to connect industrial devices to a network and to eliminate costly and time-consuming hardwiring. Direct connectivity improves communication and provides devicelevel diagnostics not available or easily accessible through hardwired I/O interfaces. DeviceNets 64-node, multi-drop network uses a single cable to interface devices up to 500m (164 ft) from your control system, rather than wiring each device to an I/O chassis. Intelligent devices on this network offer improved and more comprehensive diagnostics to reduce system downtime. These features reduced wiring, reduced start-up time, less downtime are our pledge to bring you the most advanced networking solutions available.
DH-485
DH-485 is a local area network (LAN) designed for factoryfloor applications. DH-485 lets you connect up to 32 devices, including SLC and MicroLogix controllers, HMI devices, and personal computers. Up to 32 nodes are supported.
DF1
DF1 is a proprietary Allen-Bradley master/slave protocol used to transport data over a serial data communications RS-232, RS-422, and RS-485 interface. DF1 is used for applications requiring messaging to and from Allen-Bradley controllers and other equipment.
Modbus
Modbus is a non-Rockwell Automation control architecture utilizing a half-duplex, master/slave communications protocol for transmission to controllers that support the Modbus protocol.
Communication Networks
Allen-Bradley Networks
Universal Remote I/O Max. Segment Length Max. Length Max. Nodes Rates Media Redundant Media Power to Devices 10,000 ft 30,000 ft 1 scanner; 32 nodes 57.6, 115.2, or 230.4 kbps Shielded twinaxial cable No From separate source Data Highway Plus 10,000 ft 30,000 ft 64 57.6 or 230.4 kbps Shielded twinaxial cable No From separate source DH-485 4,000 ft 32 19.2 kbps Belden 3106A No From separate source
Rockwell Automation is committed to delivering plant-wide communication as cost-effectively as possible. Whether you are integrating into an existing architecture or building a new system, Rockwell Automation can enhance your control solution.
71
On the wall
In the wall
On the floor
Then, place your PC up to 3000 feet away via a single extender cable.
In hazardous areas
www.protech1.com www.protechdirect.com
Rockwell Software HMI Software Products Allen-Bradley and Rockwell Software Index >> Electronic Operator Interface
For the latest catalog number information, visit www.rockwellsoftware.com/index.cfm
Keypad
Touch
Keypad/Touch
RS-232 Only DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M5D . . . . . . . .2711P-T6M5D . . . . . . . .2711P-B6M5D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M5A . . . . . . . .2711P-T6M5A . . . . . . . .2711P-B6M5A Ethernet, RS-232, & Modular Communication Interface DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M20D . . . . . . .2711P-T6M20D . . . . . . .2711P-B6M20D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M20A . . . . . . .2711P-T6M20A . . . . . . .2711P-B6M20A Ethernet, RS-232, & DH-485 Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M3D . . . . . . . .2711P-T6M3D . . . . . . . .2711P-B6M3D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M3A . . . . . . . .2711P-T6M3A . . . . . . . .2711P-B6M3A Ethernet, RS-232, & DH+ Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M8D . . . . . . . .2711P-T6M8D . . . . . . . .2711P-B6M8D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M8A . . . . . . . .2711P-T6M8A . . . . . . . .2711P-B6M8A Ethernet, RS-232, & Remote I/O Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M1D . . . . . . . .2711P-T6M1D . . . . . . . .2711P-B6M1D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6M1A . . . . . . . .2711P-T6M1A . . . . . . . .2711P-B6M1A
Keypad
Touch
Keypad/Touch
RS-232 Only DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C5D . . . . . . . . .2711P-T6C5D . . . . . . . . .2711P-B6C5D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C5A . . . . . . . . .2711P-T6C5A . . . . . . . . .2711P-B6C5A Ethernet, RS-232, & Modular Communication Interface DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C20D . . . . . . . .2711P-T6C20D . . . . . . . .2711P-B6C20D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C20A . . . . . . . .2711P-T6C20A . . . . . . . .2711P-B6C20A Ethernet, RS-232, & DH-485 Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C3D . . . . . . . . .2711P-T6C3D . . . . . . . . .2711P-B6C3D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C3A . . . . . . . . .2711P-T6C3A . . . . . . . . .2711P-B6C3A Ethernet, RS-232, & DH+ Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C8D . . . . . . . . .2711P-T6C8D . . . . . . . . .2711P-B6C8D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C8A . . . . . . . . .2711P-T6C8A . . . . . . . . .2711P-B6C8A Ethernet, RS-232, & Remote I/O Modular Communications DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C1D . . . . . . . . .2711P-T6C1D . . . . . . . . .2711P-B6C1D AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K6C1A . . . . . . . . .2711P-T6C1A . . . . . . . . .2711P-B6C1A
73
Keypad
Touch
Keypad/Touch
Standard Communications (Ethernet & RS-232) DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C4D1 . . . . . . .2711P-T10C4D1 . . . . . . .2711P-B10C4D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C4D2 . . . . . . .2711P-T10C4D2 . . . . . . .2711P-B10C4D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K10C4B1 . . . . . . .2711P-T10C4B1 . . . . . . .2711P-B10C4B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K10C4B2 . . . . . . .2711P-T10C4B2 . . . . . . .2711P-B10C4B2 DH+, DH-485, Remote I/O & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C6D1 . . . . . . .2711P-T10C6D1 . . . . . . .2711P-B10C6D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C6D2 . . . . . . .2711P-T10C6D2 . . . . . . .2711P-B10C6D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K10C6B1 . . . . . . .2711P-T10C6B1 . . . . . . .2711P-B10C6B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K10C6B2 . . . . . . .2711P-T10C6B2 . . . . . . .2711P-B10C6B2 ControlNet & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C15D1 . . . . . .2711P-T10C15D1 . . . . . .2711P-B10C15D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K10C15D2 . . . . . .2711P-T10C15D2 . . . . . .2711P-B10C15D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K10C15B1 . . . . . .2711P-T10C15B1 . . . . . .2711P-B10C15B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K10C15B2 . . . . . .2711P-T10C15B2 . . . . . .2711P-B10C15B2
Keypad
Touch
Keypad/Touch
Standard Communications (Ethernet & RS-232) DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C4D1 . . . . . . .2711P-T12C4D1 . . . . . . .2711P-B12C4D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C4D2 . . . . . . .2711P-T12C4D2 . . . . . . .2711P-B12C4D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K12C4B1 . . . . . . .2711P-T12C4B1 . . . . . . .2711P-B12C4B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K12C4B2 . . . . . . .2711P-T12C4B2 . . . . . . .2711P-B12C4B2 DH+, DH-485, Remote I/O & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C6D1 . . . . . . .2711P-T12C6D1 . . . . . . .2711P-B12C6D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C6D2 . . . . . . .2711P-T12C6D2 . . . . . . .2711P-B12C6D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K12C6B1 . . . . . . .2711P-T12C6B1 . . . . . . .2711P-B12C6B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K12C6B2 . . . . . . .2711P-T12C6B2 . . . . . . .2711P-B12C6B2 ControlNet & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C15D1 . . . . . .2711P-T12C15D1 . . . . . .2711P-B12C15D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K12C15D2 . . . . . .2711P-T12C15D2 . . . . . .2711P-B12C15D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K12C15B1 . . . . . .2711P-T12C15B1 . . . . . .2711P-B12C15B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K12C15B2 . . . . . .2711P-T12C15B2 . . . . . .2711P-B12C15B2
Keypad
Touch
Keypad/Touch
Standard Communications (Ethernet & RS-232) DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C4D1 . . . . . . .2711P-T15C4D1 . . . . . . .2711P-B15C4D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C4D2 . . . . . . .2711P-T15C4D2 . . . . . . .2711P-B15C4D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K15C4B1 . . . . . . .2711P-T15C4B1 . . . . . . .2711P-B15C4B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K15C4B2 . . . . . . .2711P-T15C4B2 . . . . . . .2711P-B15C4B2 DH+, DH-485, Remote I/O & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C6D1 . . . . . . .2711P-T15C6D1 . . . . . . .2711P-B15C6D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C6D2 . . . . . . .2711P-T15C6D2 . . . . . . .2711P-B15C6D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K15C6B1 . . . . . . .2711P-T15C6B1 . . . . . . .2711P-B15C6B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K15C6B2 . . . . . . .2711P-T15C6B2 . . . . . . .2711P-B15C6B2 ControlNet & Standard communications DC input, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C15D1 . . . . . .2711P-T15C15D1 . . . . . .2711P-B15C15D1 DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-K15C15D2 . . . . . .2711P-T15C15D2 . . . . . .2711P-B15C15D2 AC to DC DIN power supply, Std. (32MBFlash/64MB RAM min) . . . . . . . . . . .2711P-K15C15B1 . . . . . .2711P-T15C15B1 . . . . . .2711P-B15C15B1 AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .2711P-K15C15B2 . . . . . .2711P-T15C15B2 . . . . . .2711P-B15C15B2
Cat. No.
RSView Studio for Machine Edition Development Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSTMENE RSView Studio for RSView Enterprise Development Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSTENE
Communication Modules
Cat. No.
DH+/Remote I/O/DH-485 Network Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RN6 ControlNet Network Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RN15S
Logic Module
Cat. No.
PanelView Plus Logic Modules without Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RP PanelView Plus Logic Module with Base (32MB Flash / 64MB RAM Memory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RP1 PanelView Plus Logic Module with Base (128MB Flash / 128MB RAM Memory) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RP2
Cat. No.
PanelView Plus Compact Flash 32MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RW1 PanelView Plus Compact Flash 128MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RW2 PanelView Plus Compact Flash 256MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RW3
RAM Memory
Cat. No.
PanelView Plus & VersaView CE RAM SO-DIMM 64MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR64 PanelView Plus & VersaView CE RAM SO-DIMM 128MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR128 PanelView Plus & VersaView CE RAM SO-DIMM 256MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR256
Cat. No.
Adapts PanelView Plus 400 Keypad or 600 Touch to PanelView Standard 550 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK4 Adapts PanelView Plus 600 Keypad to PanelView Standard 600 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK6 Adapts PanelView Plus & VersaView CE 700 Keypad or Key/Touch to PanelView Standard 900 Keypad . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK7 Adapts PanelView Plus & VersaView CE 700 Touch to PanelView Standard 900 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT7 Adapts PanelView Plus & VersaView CE 1000 Keypad or Key/Touch to PanelView 1000/1000e Keypad . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK10 Adapts PanelView Plus & VersaView CE 1000 Touch to PanelView 1000/1000e Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT10 Adapts PanelView Plus & VersaView CE 1500 Keypad or Key/Touch to PanelView 1400e Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK15 Adapts PanelView Plus & VersaView CE 1500 Touch to PanelView 1400e Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT15 Adapts PVPlus/VVCE 1250 PanelView 1000/1000e Keypad or Key/Touch to PanelView 1200/1400e Keypad . . . . . . . . . . . . . . . . . . . . .2711P-RAK12E Adapts PVPlus/VVCE 1250 PanelView 1000/1000e Touch to PanelView 1200 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12E2 Adapts PVPlus/VVCE 1250 PanelView 1000/1000e Touch to PanelView 1400e Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12E Adapts PVPlus/VVCE 1250 PanelView 1000/1000e Keypad or Key/Touch to PanelView 1400 Standard Keypad . . . . . . . . . . . . . . . . . . .2711P-RAK12S Adapts PVPlus/VVCE 1250 PanelView 1000/1000e Touch to PanelView 1400 Standard Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12S
75
Cat. No.
For PanelView Plus 400 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK4 For PanelView Plus 600 Keypad or Key/Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK6 For PanelView Plus 600 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT6 For PanelView Plus & VersaView CE 700 Keypad or Key/Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK7 For PanelView Plus & VersaView CE 700 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT7 For PanelView Plus & VersaView CE 1000 Keypad or Key/Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK10 For PanelView Plus & VersaView CE 1000 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT10 For PanelView Plus & VersaView CE 1250 Keypad or Key/Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK12 For PanelView Plus & VersaView CE 1250 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT12 For PanelView Plus & VersaView CE 1500 Keypad or Key/Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK15 For PanelView Plus & VersaView CE 1500 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT15
Cables
Cat. No.
RS-232 Operating/Programming Cable (9-pin to 9-pin) 16 foot (5 meter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC13 RS-232 Operating/Programming Cable (9-pin to 9-pin) 33 foot (10 meter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC14 RS-232 Operating Cable (RS-232 D-Shell to Mini DIN) 16.4 foot (5 meter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC21 RS-232 Operating Cable (RS-232 D-Shell to Mini DIN) 49 foot (15 meter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC22 Ethernet CAT5 crossover cable (industrial grade) 4.3 meters/14 feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-CBL-EX04 Remote RS-232 Serial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC17 USB to Serial Network Interface Module (2m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-CBL-US02 USB Host-to-Host Data Transfer Cable (2m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-CBL-UU02 DH-485 Network Interface Cable (SDL AMP to RJ45) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1746-C10,11,20 DH-485 Network Interface Cable (6-pin Phoenix to RJ45) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1761-CBL-AS03, AS09
Miscellaneous
Cat. No.
Replacement Mounting Levers for PanelView 400 & 600 terminals, (Qty 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RTFC Replacement AC Power Terminal Block for PanelView 400 & 600 terminals, (Qty 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RVAC Replacement DC Power Terminal Block for PanelView 400 & 600 terminals, (Qty 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-TBDC Compact Flash to PCMCIA Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RCH USB to PS/2 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-CBL-UP02 Replacement Battery for PanelView Plus 700-1500 terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RY2032 Mounting Clips for PanelView Plus & VersaView CE 700-1500 terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RTMC AC/DC Connectors for PanelView Plus & VersaView CE 700-1500 terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-2CONN Solar Visor for VersaView CE 1250H and PanelView Plus 1250 Outdoor High-Bright Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RVT12
Bezels
Keypad
Touch
Keypad/Touch
Replacement Bezel for 7-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . . .2711P-RBK7 . . . . . . . . . .2711P-RBT7 . . . . . . . . . .2711P-RBB7 Replacement Bezel for 10-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK10 . . . . . . . . .2711P-RBT10 . . . . . . . . .2711P-RBB10 Replacement Bezel for 12-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK12 . . . . . . . . .2711P-RBT12 . . . . . . . . .2711P-RBB12 Replacement Bezel for 15-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK15 . . . . . . . . .2711P-RBT15 . . . . . . . . .2711P-RBB15 Replacement Bezel for VersaView CE 1250H and PanelView Plus 1250 High-Bright Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . .(none) . . . . . . . . . . . . . . .2711P-RBT12H . . . . . . . .(none)
VersaView CE
VersaView CE 700H Keypad Touch Keypad/Touch
Standard communications (Ethernet & RS-232) DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KRH4D . . . . . . .6182H-7TRH4D . . . . . . .6182H-7BRH4D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KEH4D . . . . . . .6182H-7TEH4D . . . . . . .6182H-7BEH4D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-7KRH4B . . . . . . .6182H-7TRH4B . . . . . . .6182H-7BRH4B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-7KEH4B . . . . . . .6182H-7TEH4B . . . . . . . .6182H-7BRH4B DH+, DH-485, Remote I/O & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KRH6D . . . . . . .6182H-7TRH6D . . . . . . .6182H-7BRH6D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KEH6D . . . . . . .6182H-7TEH6D . . . . . . .6182H-7BEH6D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-7KRH6B . . . . . . .6182H-7TRH6B . . . . . . .6182H-7BRH6B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-7KEH6B . . . . . . .6182H-7TEH6B . . . . . . . .6182H-7BEH6B ControlNet & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KRH15D . . . . . .6182H-7TRH15D . . . . . .6182H-7BRH15D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-7KEH15D . . . . . .6182H-7TEH15D . . . . . .6182H-7BEH15D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-7KRH15B . . . . . .6182H-7TRH15B . . . . . .6182H-7BRH15B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-7KEH15B . . . . . .6182H-7TEH15B . . . . . . .6182H-7BEH15B 76
VersaView CE 1000H
Keypad
Touch
Keypad/Touch
Standard communications (Ethernet & RS-232) DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KRH4D . . . . . .6182H-10TRH4D . . . . . .6182H-10BRH4D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KEH4D . . . . . .6182H-10TEH4D . . . . . .6182H-10BEH4D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-10KRH4B . . . . . .6182H-10TRH4B . . . . . .6182H-10BRH4B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-10KEH4B . . . . . .6182H-10TEH4B . . . . . . .6182H-10BRH4B DH+, DH-485, Remote I/O & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KRH6D . . . . . .6182H-10TRH6D . . . . . .6182H-10BRH6D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KEH6D . . . . . .6182H-10TEH6D . . . . . .6182H-10BEH6D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-10KRH6B . . . . . .6182H-10TRH6B . . . . . .6182H-10BRH6B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-10KEH6B . . . . . .6182H-10TEH6B . . . . . . .6182H-10BEH6B ControlNet & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KRH15D . . . . .6182H-10TRH15D . . . . .6182H-10BRH15D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-10KEH15D . . . . .6182H-10TEH15D . . . . .6182H-10BEH15D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-10KRH15B . . . . .6182H-10TRH15B . . . . .6182H-10BRH15B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-10KEH15B . . . . .6182H-10TEH15B . . . . . .6182H-10BEH15B
VersaView CE 1250H
Keypad
Touch
Keypad/Touch
Standard communications (Ethernet & RS-232) DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KRH4D . . . . . .6182H-12TRH4D . . . . . .6182H-12BRH4D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KEH4D . . . . . .6182H-12TEH4D . . . . . .6182H-12BEH4D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-12KRH4B . . . . . .6182H-12TRH4B . . . . . .6182H-12BRH4B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-12KEH4B . . . . . .6182H-12TEH4B . . . . . . .6182H-12BRH4B DH+, DH-485, Remote I/O & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KRH6D . . . . . .6182H-12TRH6D . . . . . .6182H-12BRH6D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KEH6D . . . . . .6182H-12TEH6D . . . . . .6182H-12BEH6D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-12KRH6B . . . . . .6182H-12TRH6B . . . . . .6182H-12BRH6B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-12KEH6B . . . . . .6182H-12TEH6B . . . . . . .6182H-12BEH6B ControlNet & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KRH15D . . . . .6182H-12TRH15D . . . . .6182H-12BRH15D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-12KEH15D . . . . .6182H-12TEH15D . . . . .6182H-12BEH15D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-12KRH15B . . . . .6182H-12TRH15B . . . . .6182H-12BRH15B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-12KEH15B . . . . .6182H-12TEH15B . . . . . .6182H-12BEH15B
VersaView CE 1500H
Keypad
Touch
Keypad/Touch
Standard communications (Ethernet & RS-232) DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KRH4D . . . . . .6182H-15TRH4D . . . . . .6182H-15BRH4D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KEH4D . . . . . .6182H-15TEH4D . . . . . .6182H-15BEH4D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-15KRH4B . . . . . .6182H-15TRH4B . . . . . .6182H-15BRH4B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-15KEH4B . . . . . .6182H-15TEH4B . . . . . . .6182H-15BRH4B DH+, DH-485, Remote I/O & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KRH6D . . . . . .6182H-15TRH6D . . . . . .6182H-15BRH6D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KEH6D . . . . . .6182H-15TEH6D . . . . . .6182H-15BEH6D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-15KRH6B . . . . . .6182H-15TRH6B . . . . . .6182H-15BRH6B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-15KEH6B . . . . . .6182H-15TEH6B . . . . . . .6182H-15BEH6B ControlNet & Standard communications DC input, 128MB Flash/128MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KRH15D . . . . .6182H-15TRH15D . . . . .6182H-15BRH15D DC input, 256MB Flash/256MB Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6182H-15KEH15D . . . . .6182H-15TEH15D . . . . .6182H-15BEH15D AC to DC DIN power supply, 128MB Flash/128MB Memory . . . . . . . . . . . . . .6182H-15KRH15B . . . . .6182H-15TRH15B . . . . .6182H-15BRH15B AC to DC DIN power supply, 256MB Flash/256MB Memory . . . . . . . . . . . . . .6182H-15KEH15B . . . . .6182H-15TEH15B . . . . . .6182H-15BEH15B
Cat. No.
RSView Studio for Machine Edition Development Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSTMENE RSView Studio for RSView Enterprise Development Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..9701-VWSTENE
VersaView CE Modules
Display Modules Cat. No.
VersaView CE 700H Color Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDK7C VersaView CE 700H Color Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDT7C VersaView CE 700H Color Key/Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDB7C VersaView CE 1000H Color Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDK10C VersaView CE 1000H Color Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDT10C VersaView CE 1000H Color Key/Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDB10C VersaView CE 1250H Color Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDK12C VersaView CE 1250H Color Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDT12C VersaView CE 1250H Color Key/Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDB12C VersaView CE 1250H Color Touch Screen Outdoor High-bright Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDT12H VersaView CE 1500H Color Keypad Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDK15C VersaView CE 1500H Color Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDT15C VersaView CE 1500H Color Key/Touch Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RDB15C 77
VersaView CE continued
Communication Modules Cat. No.
DH+/Remote I/O/DH-485 Network Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RN6 ControlNet Network Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RN15S
Logic Modules
Cat. No.
VersaView CE Logic Module with Std. Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RPRH VersaView CE Logic Module with Extended Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RPEH VersaView CE Logic Module with no memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RP
Cat. No.
VersaView CE Compact Flash 128MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RW2 VersaView CE Compact Flash 256MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RW3 VersaView CE Compact Flash 512MB with Machine Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-RW4
RAM Memory
Cat. No.
VersaView CE & PanelView Plus RAM SO-DIMM 64MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR64 VersaView CE & PanelView Plus RAM SO-DIMM 128MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR128 VersaView CE & PanelView Plus RAM SO-DIMM 256MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RR256
VersaView CE Accessories
Allen-Bradley and Rockwell Software Index >> Electronic Operator Interface
Power Supply External Compact Flash Card (blank) Cat. No. Cat. No.
DIN Rail mounted AC to DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RSACDIN
Compact Flash Card 32MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RC1 Compact Flash Card 128MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RC2 Compact Flash Card 256MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RC3 Compact Flash Card 512MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RC4 Compact Flash Card to PCMIA Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RCH
Cat. No.
Adapts VersaView CE & PanelView Plus 700 Keypad or Key/Touch to PanelView Standard 900 Keypad . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK7 Adapts VersaView CE & PanelView Plus 700 Touch to PanelView Standard 900 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT7 Adapts VersaView CE & PanelView Plus 1000 Keypad or Key/Touch to PanelView 1000/1000e Keypad . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAK10 Adapts VersaView CE & PanelView Plus 1000 Touch to PanelView 1000/1000e Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT10 Adapts VersaView CE & PanelView Plus 1500 Keypad or Key/Touch to PanelView Enhanced 1400 Keypad . . . . . . . . . . . . . . . . . . . . . .2711P-RAK15 Adapts VersaView CE & PanelView Plus 1500 Touch to PanelView Enhanced 1400 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT15 Adapts VVCE/PVPlus 1250 PanelView 1000/1000e Keypad or Key/Touch to PanelView 1200/1400e Keypad . . . . . . . . . . . . . . . . . . . . .2711P-RAK12E Adapts VVCE/PVPlus 1250 PanelView 1000/1000e Touch to PanelView 1200 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12E2 Adapts VVCE/PVPlus 1250 PanelView 1000/1000e Touch to PanelView 1400e Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12E Adapts VVCE/PVPlus 1250 PanelView 1000/1000e Keypad or Key/Touch to PanelView 1400 Standard Keypad . . . . . . . . . . . . . . . . . . .2711P-RAK12S Adapts VVCE/PVPlus 1250 PanelView 1000/1000e Touch to PanelView 1400 Standard Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RAT12S
Cat. No.
VersaView CE & PanelView Plus 700 Replacement Legend Strips (qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RFK7 VersaView CE & PanelView Plus 1000 Replacement Legend Strips (qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RFK10 VersaView CE & PanelView Plus 1200 Replacement Legend Strips (qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RFK12 VersaView CE & PanelView Plus 1500 Replacement Legend Strips (qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RFK15
Cat. No.
PanelView Plus & VersaView CE 700 Keypad or Key/Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK7 PanelView Plus & VersaView CE 700 Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT7 PanelView Plus & VersaView CE 1000 Keypad or Key/Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK10 PanelView Plus & VersaView CE 1000 Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT10 PanelView Plus & VersaView CE 1250 Keypad or Key/Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK12 PanelView Plus & VersaView CE 1250 Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT12 PanelView Plus & VersaView CE 1500 Keypad or Key/Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGK15 PanelView Plus & VersaView CE 1500 Touch Protective Antiglare Overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RGT15
Cables
Cat. No.
RS-232 Operating Cables to MicroLogix, 9-pin to 8-pin Mini DIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC13, NC14 RS-232 Operating/Programming Cables, 9-pin D-Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC21, NC22 Ethernet CAT5 crossover cable (industrial grade) 4.3 meters/14 feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-CBL-EX04
Miscellaneous
Cat. No.
Replacement Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RY2032 Mounting Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RTMC VersaView CE, PanelView Plus & RAC6182 DC, AC and Relay connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-2CONN Solar Visor for VersaView CE 1250H and PanelView Plus 1250 Outdoor High-Bright Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711P-RVT12 78
Bezels
Keypad
Touch
Keypad/Touch
Replacement Bezel for 7-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . . .2711P-RBK7 . . . . . . . . . .2711P-RBT7 . . . . . . . . . .2711P-RBB7 Replacement Bezel for 10-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK10 . . . . . . . . .2711P-RBT10 . . . . . . . . .2711P-RBB10 Replacement Bezel for 12-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK12 . . . . . . . . .2711P-RBT12 . . . . . . . . .2711P-RBB12 Replacement Bezel for 15-inch VersaView CE and PanelView Plus . . . . . . . . . . . . . .2711P-RBK15 . . . . . . . . .2711P-RBT15 . . . . . . . . .2711P-RBB15 Replacement Bezel for VersaView CE 1250H and PanelView Plus 1250 High-Bright Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . .(none) . . . . . . . . . . . . . . .2711P-RBT12H . . . . . . . .(none)
RS-232 (DF1) Communication Port, (8-Pin Mini-DIN) 1 . . . . . . . . . . . . . . . . . . . . . . . .2711-M3A18L1 RS-232 (DH-485) Communication Port, (8-Pin Mini-DIN) 1 . . . . . . . . . . . . . . . . . . . . .2711-M3A19L1
DH-485 Communication Ports 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A2 . . . . . . . . . . .2711-B5A2 . . . . . . . . . . .2711-T5A2L1 DH-485 Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A3 . . . . . . . . . . .2711-B5A3 . . . . . . . . . . .2711-T5A3L1 RS-232 (DH-485) Communication Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A5 . . . . . . . . . . .2711-B5A5 . . . . . . . . . . .2711-T5A5L1 RS-232 (DH-485) Communication & RS-232 Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A9 . . . . . . . . . . .2711-B5A9 . . . . . . . . . . .2711-T5A9L1 Remote I/O Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A1 . . . . . . . . . . .2711-B5A1 . . . . . . . . . . .2711-T5A1L1 DH+ Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A8 . . . . . . . . . . .2711-B5A8 . . . . . . . . . . .2711-T5A8L1 DeviceNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A10 . . . . . . . . . .2711-B5A10 . . . . . . . . . .2711-T5A10L1 Profibus (1.56 MB) Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . .2711-K5A12 . . . . . . . . . .2711-B5A12 . . . . . . . . . .2711-T5A12L1 Modbus Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A14 . . . . . . . . . .2711-B5A14 . . . . . . . . . .2711-T5A14L1 ControlNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A15 . . . . . . . . . .2711-B5A15 . . . . . . . . . .2711-T5A15L1 RS-232 (DF1) Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A16 . . . . . . . . . .2711-B5A16 . . . . . . . . . .2711-T5A16L1 EtherNet/IP Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K5A20 . . . . . . . . . .2711-B5A20 . . . . . . . . . .2711-T5A20L1
DH-485 Communication Ports 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C2 . . . . . . . . . . .2711-B6C2 . . . . . . . . . . .2711-T6C2L1 DH-485 Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C3 . . . . . . . . . . .2711-B6C3 . . . . . . . . . . .2711-T6C3L1 RS-232 (DH-485) Communication Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C5 . . . . . . . . . . .2711-B6C5 . . . . . . . . . . .2711-T6C5L1 RS-232 (DH-485) Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . .2711-K6C9 . . . . . . . . . . .2711-B6C9 . . . . . . . . . . .2711-T6C9L1 Remote I/O Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C1 . . . . . . . . . . .2711-B6C1 . . . . . . . . . . .2711-T6C1L1 DH+ Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C8 . . . . . . . . . . .2711-B6C8 . . . . . . . . . . .2711-T6C8L1 DeviceNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C10 . . . . . . . . . .2711-B6C10 . . . . . . . . . .2711-T6C10L1 Profibus (1.56 MB) Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . .2711-K6C12 . . . . . . . . . .2711-B6C12 . . . . . . . . . .2711-T6C12L1 Modbus Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C14 . . . . . . . . . .2711-B6C14 . . . . . . . . . .2711-T6C14L1 ControlNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C15 . . . . . . . . . .2711-B6C15 . . . . . . . . . .2711-T6C15L1 RS-232 (DF1) Communication & RS-232 Printer/Download Port . . . . . . . . . . . . . . . .2711-K6C16 . . . . . . . . . .2711-B6C16 . . . . . . . . . .2711-T6C16L1 EtherNet/IP Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K6C20 . . . . . . . . . .2711-B6C20 . . . . . . . . . .2711-T6C20L1
DH-485 Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G3 RS-232 (DH-485) Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . .2711-K10G9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G9 Remote I/O Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G1 DH+ Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G8 DeviceNet Communications & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G10 Profibus 1.56 MB Communications & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . .2711-K10G12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G12 Modbus Communications & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G14 ControlNet Communications & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G15 RS-232 (DF1) Communications & RS-232 Printer/Download Port . . . . . . . . . . . . . . .2711-K10G16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G16 EtherNet/IP Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10G20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10G20
1 PanelView Standard terminals with DH-485 communications (2711-xxx2, -xxx3, -xxx5, -xxx9, -xxx19) or no RS-232 printer port (2711-xxx17, -xxx18, -xxx19) require application file uploads/downloads through the communication port. The RS-232 printer port on these terminals is for printing only. 2 Add L1 to the Catalog Number to order a PanelView 550, 600, or 1000 terminal with DC power instead of AC power (for example, 2711-K10C3L1). PanelView 300 Micro, 300, 550 Touch Only and 600 Touch Only terminals are 18 to 30V dc only. 3 Add L2 to the Catalog Number of the PanelView 550 Keypad or Keypad & Touch terminal to order a stainless steel terminal with AC power (for example, 2711-K5A5L2). 4 Add L3 to the Catalog Number of the PanelView 550 Keypad or Keypad & Touch terminal to order a stainless steel terminal with DC power (for example, 2711-B5A10L3).
79
PanelView 1000 Color Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cat. No. Keypad 2 . . . . . . . . . . . . . . . . . . . . . .Cat. No. Touch
DH-485 Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C3 RS-232 (DH-485) Communication & RS-232 Printer Port 1 . . . . . . . . . . . . . . . . . . . . .2711-K10C9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C9 Remote I/O Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C1 DH+ Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C8 DeviceNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C10 Profibus (1.56 MB) Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . .2711-K10C12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C12 Modbus Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C14 ControlNet Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C15 RS-232 (DF1) Communication & RS-232 Printer/Download Port . . . . . . . . . . . . . . . .2711-K10C16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C16 EtherNet/IP Communication & RS-232 Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . .2711-K10C20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-T10C20
Cat. No.
Cat. No.
For the PanelView 300 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NF7 For the PanelView 550 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NF1 For the PanelView 600 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NF4 For the PanelView 1000 Grayscale and Color Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NF6 For the PanelView 1400 Color Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NF5
Mounting Hardware
Cat. No.
Replacement Mounting Clips for the PanelView 600 Keypad and Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NP2 Replacement Mounting Clips for the PanelView 1400 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NP1 Mounting Studs for the PanelView 1400 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NP3
Cat. No.
Real-Time Clock for PanelView 550 Keypad or Keypad & Touch (Series A through Series D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NB2 Real-Time Clock for PanelView 550 Keypad or Keypad & Touch (Series E and F), 600 Keypad or Keypad & Touch, 900, 1000, 1400 Terminals . .2711-NB3 Real-Time Clock for PanelView 300 Keypad and PanelView 550 (series G and later)/PanelView 600 Touch Screen Only Terminals . . .2711-NB4
Backlights
Cat. No.
Replacement Backlight Lamp for PanelView 600 Keypad or Keypad & Touch Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NL3 Replacement Backlight Lamp for PanelView 1000 Color Terminal (Series A Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NL4 Replacement Backlight Lamp for PanelView 1000 Color Terminal (Series B Only) (contact factory for availability) . . . . . . . . . . . . . . . . .2711-NL6 Replacement Backlight Lamp for PanelView 1000 Color Terminal (Series C Only) (contact factory for availability) . . . . . . . . . . . . . . . . .2711-NL7 Replacement Backlight Lamp for PanelView 1000 Color Terminal (Series D and Series C PanelView 1000 Gray Scale) . . . . . . . . . . . . .2711-NL9
Antiglare Overlays
Cat. No.
Antiglare Overlay for the PanelView 300 Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV8 Antiglare Overlay for the PanelView 550 Keypad or Keypad & Touch Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV4 Antiglare Overlay for the PanelView 550/600 Touch Screen Only Terminals (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV4T Antiglare Overlay for the PanelView 600 Keypad or Keypad & Touch Terminals (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV5 Antiglare Overlay for the PanelView 1000 Keypad Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV6K Antiglare Overlay for the PanelView 1000 Touch Screen Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV6T Antiglare Overlay for the PanelView 1400 Keypad Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV7K Antiglare Overlay for the PanelView 1400 Touch Screen Terminal (Qty 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV7T
Cat. No.
Wallmount power supply provides power to 1747-PIC Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1747-NP1 DC Power Terminal Block for PanelView 300 Micro Terminal (Qty 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-TBDC 80
Cables
Cat. No.
Personal Computer Interface Converter converts RS-232 signals to/from DH-485 signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1747-PIC 6 foot (1.83 meter) DH-485 Operating/Programming Cable (for 2711-xxA2, -xxA3, -xxC2, -xxC3, -xxG3) . . . . . . . . . . . . . . . . . . . . . . . . .1747-C10 1 foot (0.30 meter) DH-485 Operating/Programming Cable (for 2711-xxA2, -xxA3, -xxC2, -xxC3, -xxG3) . . . . . . . . . . . . . . . . . . . . . . . . .1747-C11 20 foot (6.1 meter) DH-485 Operating/Programming Cable (for 2711-xxA2, -xxA3, -xxC2, -xxC3, -xxG3) . . . . . . . . . . . . . . . . . . . . . . . . .1747-C20 Isolated Link Coupler for DH-485 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1747-AIC AIC+ Advanced Interface Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1761-NET-AIC Remote RS-232 Serial Port assembly for PanelView Standard terminals (with RS-232 Printer Ports) and PanelView 1000e/1400e terminals 2711-NC17 16.4 foot (5 meter) RS-232 Operating/Programming Cable (9-pin D-Shell to 9-pin D-Shell) 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC13 32.7 foot (10 meter) RS-232 Operating/Programming Cable (9-pin D-Shell to 9-pin D-Shell) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC14 16.4 foot (5 meter) RS-232 Operating Cable (RS-232 D-Shell to Mini DIN) for MicroLogix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC21 49 foot (15 meter) RS-232 Operating Cable (RS-232 D-Shell to Mini DIN) for MicroLogix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC22 10 foot (3 meter) RS-232 Operating/Programming Cable (9-pin D-Shell to 9-pin D-Shell) 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-NC13 16.4 foot (5 meter) RS-232 Operating Cable for PanelView 300 Micro Terminal to MicroLogix (8-pin Mini DIN to 8-pin Mini DIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-CBL-HM05 32.7 foot (10 meter) RS-232 Operating Cable for PanelView 300 Micro Terminal to MicroLogix (8-pin Mini DIN to 8-pin Mini DIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-CBL-HM10 16.4 foot (5 meter) RS-232 Operating Cable for PanelView 300 Micro Terminal to SLC or PLC (9-pin D-Shell to 8-pin Mini DIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-CBL-PM05 32.7 foot (10 meter) RS-232 Operating Cable for PanelView 300 Micro Terminal to SLC or PLC (9-pin D-Shell to 8-pin Mini DIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-CBL-PM10 1.5 foot (0.5 meter) RS-232 Operating Cable for PanelView 300 Micro to MicroLogix (8-pin Mini DIN to 8-pin Mini DIN) . . . . . . . . . . .1761-CBL-AM00 6.5 foot (2 meter) RS-232 Operating Cable for PanelView 300 Micro to MicroLogix (8-pin Mini DIN to 8-pin Mini DIN) . . . . . . . . . . . .1761-CBL-HM02 1.5 foot (0.5 meter) RS-232 Operating/Programming Cable for PanelView 300 Micro to SLC or PLC (9-pin D-shell to 8-pin Mini DIN) .1761-CBL-AP00 6.5 foot (2 meter) RS-232 Operating/Programming Cable for PanelView 300 Micro to SLC or PLC (9-pin D-shell to 8-pin Mini DIN) . . .1761-CBL-PM02
5 Cable used for operation/communication with the following PanelViews: 2711-xxx5, -xxx9, -xxx16, -xxx17. Cable used for application file transfer or printing with the following PanelViews: 2711-xxx1, -xxx3, -xxx8, -xxx9, -xxx10, -xxx12, -xxx14, -xxx15, -xxx16, -xxx17, -xxx20.
PanelBuilder 1400e Windows Development Software Kits for PanelView 1000e, 1200e, 1400e and enhanced Series F or G PanelView 1200 Terminals with Enhancement Kit (Cat. No. 2711E-U1B12C)
Cat. No.
English PanelBuilder 1400e Development Software for Windows 3.1 and above, Windows 95 or Windows NT . . . . . . . . . . . . . . . . . .2711E-ND1 French PanelBuilder 1400e Development Software for Windows 3.1 and above, Windows 95 or Windows NT . . . . . . . . . . . . . . . . . . .2711E-ND1FR German PanelBuilder 1400e Development Software for Windows 3.1 and above, Windows 95 or Windows NT . . . . . . . . . . . . . . . . . .2711E-ND1DE Spanish PanelBuilder 1400e Development Software for Windows 3.1 and above, Windows 95 or Windows NT . . . . . . . . . . . . . . . . . .2711E-ND1ES English File Transfer Utilities for PanelView 1000e, 1200e, 1400e and enhanced Series F and G PanelView 1200 Terminals with Enhancement Kit (Catalog Number 2711E-U1B12C) and PV1200 Terminals. Note: Included in the PB1400e software kits. This is a stand-alone utility for file transfers only and requires less hard-disk space the PanelBuilder 1400e software kits. These utilities are shipped on 3-1/2 inch floppy disks including RSLinx Lite. . . . . .2711E-ND7
PanelBuilder 1200 Character Graphics CRT Terminal Software Kits for DOS and Windows
Cat. No.
English PanelBuilder 1200 Development Software for Windows 3.1 or later . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-ND1W English PanelBuilder 1200 Development Software for DOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-ND1
Cat. No.
PanelView 1200 Keypad to PanelView 1000e Keypad Migration Kit. Includes (1) PV1000e DH+/Remote I/O Keypad terminal (2711E-K10C6), (1) 2711-NR5K Cutout Adapter Kit and (1) 2711-NC13 Upload/Download Cable. . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-UKCK10 PanelView 1200 Touch to PanelView 1000e Touch Migration Kit. Includes (1) PV1000e DH+/Remote I/O Touch terminal (2711E-T10C6), (1) 2711-NR5T Cutout Adapter Kit and (1) 2711-NC13 Upload/Download Cable . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-UTCT10
Cat. No.
PanelView 1200e Keypad to PanelView 1000e Keypad Migration Kit. Includes (1) PV1000e DH+/Remote I/O Keypad terminal (2711E-K10C6), (1) 2711-NR5K Cutout Adapter Kit and (1) 2711-NC13 Upload/Download Cable. . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-UK12EK10 PanelView 1200e Touch to PanelView 1000e Touch Migration Kit. Includes (1) PV1000e DH+/Remote I/O Touch terminal (2711E-T10C6), (1) 2711-NR5T Cutout Adapter Kit and (1) 2711-NC13 Upload/Download Cable. . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-UT12ET10 81
PanelView e continued
Cat. No.
10 foot (3 meter) RS-232 Upload/Download Cable (9-pin to 25-pin) for PanelView 1400e (Series A-E), 1200e and 1200 terminals . . . .2711-NC1 16 foot (5 meter) RS-232 Upload/Download Cable (9-pin to 9-pin) for PanelView 1000e and 1400e (Series F and later) terminals. For application file transfers between the terminal and development computer. Also used for PV300/550/600/900/1000/1400 terminals. 2711-NC13 10 foot (3 meter) RS-232 Upload/Download Cable (9-pin to 9-pin) for PanelView 1000e and 1400e (Series F and later) terminals . . . .2706-NC13 33 foot (10 meter) RS-232 Upload/Download Cable (9-pin to 9-pin) for PanelView 1000e and 1400e (Series F and later) terminals . . .2711-NC14 RS-232 Download Cable Adapter for 2711-NC1. Includes a 25-pin DB female to 9-pin DB female cable . . . . . . . . . . . . . . . . . . . . . . . .2711-NC18 Remote keyswitch and RS-232 port assembly, with 3.1 m (10 ft) cable for PanelView 1400e (Series A-E), 1200e/1200 terminals. . . .2711-NC2 Remote RS-232 Serial Port assembly for PanelView 1000e and 1400e (Series F and later) terminals. Includes a 9-pin RS-232 port assembly to allow remote serial port access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NC17
Cat. No.
Mounting Clips for PanelView 600/900/1000/1000e Touch Screen and Keypad terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NP2 Adapter to mount PanelView 1000/1000e Keypad terminal in panel cutout for a PanelView 1200/1400e Keypad terminals. . . . . . . . .2711-NR5K Adapter to mount PanelView 1000/1000e Touch Screen terminal in panel cutout for a PanelView 1200 Touch Screen terminal. . . . .2711-NR5T Adapter to mount PanelView 1000/1000e Touch Screen terminal in panel cutout for a PanelView 1400e Touch Screen terminal. . . .2711-NR7T 19-inch Rack Mount Kit for PanelView 1400e Touch Screen terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NR4 19-inch Rack Mount Kit for PanelView 1000/1000e Keypad terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NR6K 19-inch Rack Mount Kit for PanelView 1000/1000e Touch Screen terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NR6T ISA Card Adapter Kit for installing a communication card in a PanelView 1400e (Series A-E) terminal . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NA1 ISA Card Adapter Kit for installing a communication card in a PanelView 1000e terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NA2 ISA Card Adapter Kit for installing a communication card in a PanelView 1400e (Series F and later) terminals . . . . . . . . . . . . . . . . . . .2711E-NA3
Cat. No.
Antiglare protective overlay for PanelView 1000/1000e Touch Screen terminals (Quantity of 3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV6T Antiglare protective overlay for PanelView 1000/1000e Keypad terminals (Quantity of 3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NV6K Antiglare protective overlay for PanelView 1400e Keypad and Touch Screen terminals (Quantity of 5). . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NV1 Function Key Legend Inserts for PanelView 1000e Keypad terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NF1 Function Key Legend Inserts for PanelView 1400e Keypad terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NF2 Keypad Replacement Kit for PanelView 1400e Keypad terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NK5 Analog Touch Screen Replacement Kit for PanelView 1400e Touch Screen terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NT2
Backlights
Cat. No.
Backlight Replacement Kit for PanelView 1000e (Series C and earlier) terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-NL2 Backlight Replacement Kit for PanelView 1000e (Series D and later) terminals and PanelView 1000 (Series B) . . . . . . . . . . . . . . . . . . .2711-NL6 Backlight Replacement Kit for PanelView 1000e (Series E and later) terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711-NL9
Cat. No.
Firmware Enhancement Kit for Modbus communications on PanelView 1000e/1400e terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-UMOD System Memory Upgrade Kit for PanelView 1000e and 1400e (Series F and later) terminals. For 8 Mbyte total system RAM. . . . . . .2711E-URAM1 System Memory Upgrade Kit for PanelView 1400e (Series A-E) terminals. For 4 Mbyte total system RAM. . . . . . . . . . . . . . . . . . . . . .2711E-URAM2
Cat. No.
DH+ / Remote I/O Connector for PanelView 1000e/1200/1200e/1400e terminals. Also used for PV550/600/900/1000/1400 terminals. .2711-NDRC Spare Mode Select Keys for PanelView 1000e/1200/1200e/1400e terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NKEY1 Replacement Keyswitch Assembly for PanelView 1200/1200e/1400e (Series E or earlier) terminals. . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NKSW1 Replacement Keyswitch Assembly for PanelView 1000e and 1400e (Series F or later) terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2711E-NKSW2
Message Displays
InView Message Displays Cat. No.
2 lines, 20 characters, 0.7 in high (1.8cm), panel mount, Red LEDs, NEMA 4x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P22R 1 or 2 lines, 12 or 20 characters, 4.8" or 2.1" (12.2cm to 5.3cm) high, Red LEDs, NEMA Type 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P42R 1 or 2 lines, 12 or 20 characters, 4.8" or 2.1" (12.2cm to 5.3cm) high, Tri-Color LEDs, NEMA Type 12 . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P42C 1 or 2 line, 24 or 40 characters, 4.8" or 2.1" (12.2cm to 5.3cm) high, Red LEDs, NEMA Type 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P44R 1 or 2 line, 24 or 40 characters, 4.8" or 2.1" (12.2cm to 5.3cm) high, Tri-Color LEDs, NEMA Type 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P44C 1 to 4 line, 12 to 24 characters, 7.2" to 1.5" (18.3cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P72CN2 1 to 4 line, 20 to 40 characters, 7.2" to 1.5" (18.3cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P74CN2 1 and 2 to 4 line, 20 to 24 characters, 7.2" to 1.5" (18.3cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 4X . . . . . . . . . . . . . . . . . . . . . .2706-P72CN1 1 to 4 line, 12 to 40 characters, 7.2" to 1.5" (18.3cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 4X . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-P74CN1 1 to 5 line, 13 to 24 characters, 9.6" to 1.5" ( 24.4cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 12/13 . . . . . . . . . . . . . . . . . . . . . . . .2706-P92C 1 to 5 line, 26 to 48 characters, 9.6" to 1.5" (24.4cm to 3.8cm) high, Tri-Color LEDs, NEMA Type 12/13 . . . . . . . . . . . . . . . . . . . . . . . . .2706-P94C 82
InView Accessories
Cat. No.
Messaging Software with ActiveX control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PSW1 Program Download Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PCABLE1 NEMA Type 12/13 enclosure for 2706-P22R display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-NE1 Ethernet TCP/IP Communications Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PENET1 Remote I/O Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PRIOP Remote I/O Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PRIOM Remote I/O Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PRIOK DH-485 Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDH485P DH-485 Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDH485M DH-485 Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDH485K DH+ Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDHPP DH+ Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDHPM DH+ Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDHPK DeviceNet Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDNETP DeviceNet Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDNETM DeviceNet Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PDNETK ControlNet Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PCNETP ControlNet Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PCNETM ControlNet Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PCNETK EtherNet/IP Communication Modules for 2706-P22R, 24V dc DIN rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PENETP EtherNet/IP Communication Modules for 2706-P4x, mounts to back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PENETM EtherNet/IP Communication Modules for 2706-P7x and -P9x, internal mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2706-PENETK
Cat. No.
Workstation, 12-inch TFT Display, Keypad and Touch Screen, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-12BPXPH Workstation, 12-inch TFT Display, Keypad and Touch Screen, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP, 24V DC Powered . . . . . . . . . . . . . . . . . . . . . . .6180W-12BPXPHDC Workstation, 12-inch TFT Display, Keypad and Touch Screen, Standard Features: Pentium 4, 2 GHz Celeron, 256 MB RAM, 80 GB Hard Drive, Floppy Drive, CD-ROM Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-12BSXPH Workstation, 12-inch TFT Display, Keypad, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-12KPXPH Workstation, 12-inch TFT Display, Keypad, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP, 24V DC Powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-12KPXPHDC Workstation, 12-inch TFT Display, Keypad, Standard Features: Pentium 4, 2 GHz Celeron, 256 MB RAM, 80 GB Hard Drive, Floppy Drive, CD-ROM Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-12KSXPH Workstation, 15-inch TFT Display, Keypad and Touch Screen, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-15BPXPH Workstation, 15-inch TFT Display, Keypad and Touch Screen, Standard Features: Pentium 4, 2 GHz Celeron, 256 MB RAM, 80 GB Hard Drive, Floppy Drive, CD-ROM Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-15BSXPH Workstation, 15-inch TFT Display, Keypad, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-15KPXPH Workstation, 15-inch TFT Display, Keypad, Standard Features: Pentium 4, 2 GHz Celeron, 256 MB RAM, 80 GB Hard Drive, Floppy Drive, CD-ROM Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-15KSXPH Non-Display, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-7PXPH Non-Display, Performance Features: Pentium 4, 2 GHz, 512 MB RAM, 80 GB Hard Drive, Floppy Drive, DVD/CD-RW Drive; Windows XP, 24V DC Powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6180W-7PXPHDC
Cat. No.
12-inch TFT Display, Performance Features: Pentium IV, 2GHz, 512 MB RAM, Floppy Drive, 40 GB Hard Drive, DVD/CD-RW Drive, 2 PCI slots, Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6181P-12NPXPH 12-inch TFT Display, Standard Features: Pentium IV, 2GHz Celeron, 256 MB RAM, Floppy Drive, 40 GB Hard Drive, CD-ROM Drive, 2 PCI slots, Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6181P-12NSXPH 12-inch TFT Display, Touch Screen, Performance Features: Pentium IV, 2GHz, 512 MB RAM, Floppy Drive, 40 GB Hard Drive, DVD/CD-RW Drive, 2 PCI slots, Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6181P-12TPXPH 12-inch TFT Display, Touch Screen, Performance Features: Pentium IV, 2GHz, 512 MB RAM, Floppy Drive, 40 GB Hard Drive, DVD/CD-RW Drive, Windows XP, 2 PCI slots, 24VDC Powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6181P-12TPXPHDC 83
Cat. No.
12-inch Flat Panel Monitor, Aluminum Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M12AL 12-inch Flat Panel Monitor, Aluminum Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . . .6186-M12ALTR 15-inch Flat Panel Monitor, Aluminum Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M15AL 15-inch Flat Panel Monitor, Aluminum Bezel, Capacitive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . .6186-M15ALTC 15-inch Flat Panel Monitor, Aluminum Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . . .6186-M15ALTR 15-inch Flat Panel Monitor, Stainless Steel Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M15SS 15-inch Flat Panel Monitor, Stainless Steel Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . .6186-M15SSTR 17-inch Flat Panel Monitor, Aluminum Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M17AL 17-inch Flat Panel Monitor, Aluminum Bezel, Capacitive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . .6186-M17ALTC 17-inch Flat Panel Monitor, Aluminum Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . . .6186-M17ALTR 17-inch Flat Panel Monitor, Stainless Steel Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M17SS 17-inch Flat Panel Monitor, Stainless Steel Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . .6186-M17SSTR 20-inch Flat Panel Monitor, Aluminum Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M20AL 20-inch Flat Panel Monitor, Aluminum Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . . . . . .6186-M20ALTR 20-inch Flat Panel Monitor, Rack Mount, Aluminum Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . .6186-M20RK 20-inch Flat Panel Monitor, Rack Mount, Aluminum Bezel, Resistive Touch Screen, includes required cables and power supply . . . . .6186-M20RKTR 20-inch Flat Panel Monitor, Stainless Steel Bezel, includes required cables and power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6186-M20SS 20-inch Flat Panel Monitor, Stainless Steel Bezel, Resistive Touch Screen, includes required cables and power supply . . . . . . . . . . . .6186-M20SSTR
Cat. No.
2.5" HARD DISK DRIVE STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-25HDD VERSAVIEW SHOCK ASSEMBLY FOR 2.5" HARD DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-25HDDSA 3.5" HARD DISK DRIVE STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-35HDD CD-ROM DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-CDROM CD DRIVE WRITEABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-CDRW 84
FLOPPY DISK DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-FD144 CD DRIVE READ ONLY (SLIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SLCDROM CD DRIVE WRITEABLE (SLIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SLCDRW CD DRIVE WRITEABLE DVDROM (SLIM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SLCOMBO CD/DVD DRIVE READ ONLY (SLIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SLDVDROM FLOPPY DISK DRIVE SLIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SLFD144
Cat. No.
FAN FILTER (1500W) 5-PACK (WORKSTATION) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-FANFIL1 FAN FILTER (1400R) 5-PACK (RACK MOUNT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-FANFIL2 FAN FILTER (700R) 5-PACK (MACHINE MOUN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-FANFIL3
Cat. No.
DIMM MEMORY 128MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DIMM128 DIMM MEMORY 256MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DIMM256 DIMM MEMORY 512MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DIMM512 DIMM RAM MEMORY 1024MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DIMM1G DDR RAM MEMORY 256MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DDR256 DDR RAM MEMORY 512MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DDR512 DDR RAM MEMORY 1024MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DDR1G
Cat. No.
VERSAVIEW 1500P 2ND PCI SLOT ACCESSORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-2PCI15 BENCH/TABLE TOP ADAPTER FOR 6186 MONITORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MBA WALL MOUNTING ADAPTER FOR ALL PLATFORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MWA MOUNTING CLIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MCLPS PANEL ADAPTER 6185-B TO 6186-M12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MMA12 MNTG ADAPTER FOR CONVERTING 6185-C OR J TO 1500M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MMA15 MNTG ADAPTER FOR CONVERTING 6185-D OR H TO 1700M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MMA17 RACK ADAPTER FOR 12.1" PLATFORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MRA12 RACK ADAPTER FOR 15" PLATFORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MRA15 RACK ADAPTER FOR 17" PLATFORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-MRA17 1400R RACKSLIDES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-RACKSLIDES
Cat. No.
DIGITAL VIDEO CABLE 6186 2M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DVICBL2 DIGITAL VIDEO CABLE 6186 5M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-DVICBL5 PS2 Y-ADAPTER 5-PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-KMYCONN IEC AC POWER CORD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-ACCORD ANALOG VIDEO CABLE 6186 15' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-SDNC21 SERIAL TOUCHSCREEN CABLE 6186 16,4' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-SE2903
Cat. No.
MATROX PCI VIDEO CARD FOR DVI CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-PCIDVI 2 CHANNEL RS232 PCI CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-COMMCARD
Cat. No.
VV 12"SCREEN PROT.10 PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SCRNCOVER12 VV 15" SCREEN PROT.10 PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SCRNCOVER15 VV 17" SCREEN PROT.10 PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SCRNCOVER17 VV 20" SCREEN PROT.10 PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189V-SCRNCOVER20
Cat. No.
SEALED MOUSE - DESKTOP PS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-HPMOUSE SEALED MOUSE - PANELMOUNT PS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-HPMOUSEP DESKTOP KEYBOARD & MOUSE PLASTIC USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-KBDEPC1U DESKTOP KEYBOARD AND MOUSE STAINLESS STEEL PS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-KBDEPS1 SMALL DESKTOP KEYBOARD AND MOUSE PLASTIC USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-KBDEPU1U PANELMOUNT KEYBOARD AND MOUSE STAINLESS STEEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6189-KBPEPS1
85
Cat. No.
The Linx bundle is RSLinx Classic (2.x) for RSView and also RSLinx Enterprise RSView SE Server 25 Display w/RSLinx Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSS025LENE RSView SE Server 100 Display w/RSLinx Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSS100LENE RSView SE Server 250 Display w/RSLinx Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSS250LENE RSView SE Server Unlimited Display w/RSLinx Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWSS000LENE
Cat. No.
Order localized versions of RSView Machine Edition by replacing the EN in the catalog number with: DE for German, FR for French, and JP for Japanese. RSView Machine Edition includes RSLinx Enterprise and KEPServer Enterprise. RSView Studio for Machine Edition Configuration software for developing and testing machine level HMI applications . . . . . . . . . . . . . . . . . .9701-VWSTMENE RSView Machine Edition Station Runtime for Windows 2000/XP Used to run RSView ME projects created with RSView Studio on any computer with the Windows 2000/XP operating system including the VersaView industrial computers RSView Machine Edition Station Runtime 15 Displays Windows 2000/XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWMR015AENE RSView Machine Edition Station Runtime 30 Displays Windows 2000/XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWMR030AENE RSView Machine Edition Station Runtime 75 Displays Windows 2000/XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9701-VWMR075AENE RSView Machine Edition Station Runtime is included with PanelView Plus and VersaView CE terminals.
RSView32
Cat. No.
Monitoring, control and data acquisition RSView32 Runtime 150 with RSLinx Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3104 RSView32 Runtime 150 with RSLinx Includes 9301-2SE3100 RSView32 Runtime 150 and 9355-WABENE RSLinx . . . . . . . . . . . . . .9301-2SE3103 RSView32 Runtime 150 150 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3100 RSView32 Works 150 with RSLinx Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2104 RSView32 Works 150 with RSLinx Includes 9301-2SE2100 RSView32 Works 150 and 9355-WABENE RSLinx . . . . . . . . . . . . . . . . .9301-2SE2103 RSView32 Works 150 150 Tag Database. Includes Development and one embedded Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2100 RSView32 Runtime 300 with RSLinx Classic Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3204 RSView32 Runtime 300 with RSLinx Classic Includes 9301-2SE3203 RSView32 Runtime 300 and 9355-WABENE RSLinx Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3203 RSView32 Runtime 300 300 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3200 RSView32 Works 300 with RSLinx Classic Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2204 RSView32 Works 300 with RSLinx Classic Includes 9301-2SE2200 RSView32 Works 300 and 9355-WABENE RSLinx Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2203 RSView32 Works 300 300 Tag Database. Includes Development and one embedded Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2200 RSView32 Runtime 1500 with RSLinx Classic Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3304 RSView32 Runtime 1500 with RSLinx Classic Includes 9301-2SE3300 RSView32 Runtime 1500 and 9355-WABENE RSLinx Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3303 RSView32 Runtime 1500 1500 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3300 RSView32 Works 1500 with RSLinx Classic Single Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2304 RSView32 Works 1500 with RSLinx Classic Includes 9301-2SE2300 RSView32 Works 1500 and 9355-WABENE RSLinx Classic . .9301-2SE2303 RSView32 Works 1500 1500 Tag Database. Includes Development and one embedded Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2300 RSView32 Runtime 5000 with RSLinx Classic Includes 9301-2SE3500 RSView32 Runtime 5000 and 9355-WABENE RSLinx Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3353 RSView32 Runtime 5000 5000 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3350 RSView32 Works 5000 with RSLinx Classic Includes 9301-2SE2350 RSView32 Works 5000 and 9355-WABENE RSLinx Classic . .9301-2SE2353 RSView32 Works 5000 5000 Tag Database. Includes Development and one embedded Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2350 RSView32 Runtime 32K with RSLinx Classic Includes 9301-2SE3400 RSView32 Runtime 32K and 9355-WABENE RSLinx Classic . 9301-2SE3403
86
RSView32 Runtime 32K 32,000 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3400 RSView32 Works 32K with RSLinx Classic Includes 9301-2SE2400 RSView32 Works 32k and 9355-WABENE RSLinx Classic . . . . .9301-2SE2403 RSView32 Works 32K 32,000 Tag Database. Includes Development and one embedded Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2400 RSView32 Runtime 100K with RSLinx Classic Includes 9301-2SE3500 RSView32 Runtime 100K and 9355-WABENE RSLinx Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3503 RSView32 Runtime 100K 100,000 Tag Database. Stand Alone Runtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3500 RSView32 Works 100K with RSLinx Classic Includes 9301-2SE2500 RSView32 Works 100K and 9355-WABENE RSLinx Classic . .9301-2SE2503 RSView32 Works 100K 100,000 Tag Database. Includes Development and one embedded Runtime. . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2500 RSView32 WebServer Expand your view with the web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-RSVWSENE RSView32 Messenger Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-MSGRPROENE
Cat. No.
Client/Server Enhancement to RSView32 RSView32 Active Display Server Includes one Active Display Server (no clients) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADSENE RSView32 Active Display Server with RSLinx Gateway Includes one Active Display Server (no clients) and 9355-WABGWENE RSLinx Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-ADSGWENE RSView32 Active Display Floating Client Includes one client with server-side activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADFCENE RSView32 Active Display Dedicated Client Includes one client with client-side activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADDCENE RSView32 Active Display Floating View Client Includes one view-only client with server-side activation . . . . . . . . . . . . . . . . . . . . . .9305-RSVADFVCENE
RSView32 Languages
Cat. No.
Choose language, insert 2 characters to replace xx in catalog number: Spanish - use ES, French - use FR, Italian - use IT, German - use DE, Portuguese - use PT, Japanese - use JP, Chinese - use ZH, Korean - use KO RSView32 Works 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2100xxE RSView32 Works 150 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2103xxE RSView32 Works 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2200xxE RSView32 Works 300 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2203xxE RSView32 Works 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2300xxE RSView32 Works 1500 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2303xxE RSView32 Works 5K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2350xxE RSView32 Works 5K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2353xxE RSView32 Works 32K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2400xxE RSView32 Works 32K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2403xxE RSView32 Works 100K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2500xxE RSView32 Works 100K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2503xxE RSView32 Runtime 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE2500xxE RSView32 Runtime 150 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3103xxE RSView32 Runtime 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3200xxE RSView32 Runtime 300 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3203xxE RSView32 Runtime 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3300xxE RSView32 Runtime 1500 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3303xxE RSView32 Runtime 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3350xxE RSView32 Runtime 5000 with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3353xxE RSView32 Runtime 5K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3350xxE RSView32 Runtime 5K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3353xxE RSView32 Runtime 32K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3400xxE RSView32 Runtime 32K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3403xxE RSView32 Runtime 100K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3500xxE RSView32 Runtime 100K with RSLinx Classic Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9301-2SE3503xxE Choose language, insert 2 characters to replace xx in catalog number: Spanish - use ES, French - use FR, Italian - use IT, German - use DE, Portuguese - use PT RSView32 Active Display Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADSxxE RSView32 Active Display Floating Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADFCxxE RSView32 Active Display Dedicated Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADDCxxE RSView32 Active Display Floating View Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9305-RSVADFVCxxE
Recipe Plus
In the near future, Recipe Plus will be available as a feature of RSView Machine Edition. Recipe Plus will apply to any application where rapid changeovers are required. With Recipe Plus operators can download several values to multiple controllers in a single operation. These values may be type and quantities of ingredients or materials, speed, duration, temperature, position or to enable specific steps in the process. In addition, the operator will be able to upload, display, modify and save recipes. Creating the recipes in RSView Studio, you will specify the name of the ingredients and data sets and tag sets associated with the specific ingredient. The multiple data sets can be a variation of the values of a basic recipe. The multiple data sets allow you to download the values to multiple lines. From the editor in RSView Studio, you will be able to compare recipe files for differences as well as copy/pass the contents of the recipe file to and from Microsoft Excel.
onthehorizon
DeviceNet Communications
PanelView Plus and VersaView CE will be supporting DeviceNet communications in the near future. This communication method will be implemented in two phases. Phase 1 will support DeviceNet I/O messaging, and phase 2 will support DeviceNet Explicit Messaging. DeviceNet I/O messaging will support both master and slave communications. A total of 2048 bytes of input data and 2048 bytes of output data can be transferred. Slave messaging will have a maximum of 255 bytes for input data and 255 bytes for output data. Slave messaging will function similar to the PanelView Standard. Master messaging will allow the PanelView Plus / VersaView CE to retrieve and send non-critical data to other DeviceNet slave devices, such as devices from Entek and motion controllers. DeviceNet I/O communications for the PanelView Plus / VersaView CE will support Logix, PLC-5, and SLC-500 processors. Users of DeviceNet I/O communications will configure the DeviceNet network using RSNetworx for DeviceNet. RSView Studio will be used to configure DeviceNet communications on the PanelView Plus / VersaView CE, which will be similar to configuring Remote I/O and ControlNet Scheduled communications. DeviceNet Explicit Messaging will allow DeviceNet communications between other DeviceNet devices that support Explicit Messaging without the need to use RSNetworx to configure a DeviceNet scanner.
88
Language Switching
RSView Supervisory Edition (SE) and Machine Edition (ME) will be supporting run-time language switching in a future release. This will allow users to dynamically change the text of their displays to another language with the touch of a button. In addition, RSView SE will support language switching by using a command or VBA. This feature can be used by OEMs who sell their products to other countries or end users that have an ethnically diverse work force. Dynamic language switching can be used with user definable text objects such as graphic displays, global objects, library displays, and title bars. Besides basic text, dates and decimal formats will also be able to be dynamically switched. Language switching will not support RSView ME configuration screens, error messages, or alarm messages. RSView SE Clients can switch languages independently, so multiple devices can display different languages. Up to 10 different languages will be supported. When developing language switching displays within RSView Studio, the developer will select the specific language that they want to develop to. Then, the developer can use the string import/export feature to efficiently implement the specific text for the different languages. To save on memory space on RSView ME platforms, the developer will be able to specify the specific languages that will be compiled in the project.
FactoryTalk Security
Because of FactoryTalks open nature, the FactoryTalk Security module helps limit the potential for risk through authentication and authorization of users. It provides an answer to the one question that companies must ask before granting secure access to manufacturing systems: Who can carry out what actions upon which secured resources from where? Authentication requires that any user attempting to access resources in a Rockwell Software application must pass certain criteria before access is granted. The system must be able to positively verify the users identity and verify that the request for service actually originated with the requesting user. Authorization will check the users access rights and privileges so the user is only authorized if the resource request matches the rights and privileges for the user. Flexible administration In addition to increased security, FactoryTalk Security will cut down on administrative security tasks. It will allow re-use of existing Windows users and groups lists, eliminating individual databases for each automation product, improving maintenance and reducing the chance for errors. And, because the security needs of a general purpose network domain are often quite different from the needs of an automation system, FactoryTalk Security will allow administrators to maintain group security separate from Windows even if Windows is providing user-level authentication. With each FactoryTalk-enabled product defining its own securable resources, you will be able to tailor the security system to the objects and actions that you need secured, and maintain this system without interfering with Windows security.
to users and users. Different who refers need differentgroups ofrights and need to users access be associated with those rights at all times. actions performed what refersastoread, write, delete, on any resource, such etc. for which actions which refers to the resourcesexample, securable are to be secured. For resources may be defined as tags or displays in the RSView Supervisory Edition operator interface software. location and where refers to machine For example, related specified actions. for physical safety, downloading to a controller might be restricted to workstations with a clear line-ofsight to machinery affected by the download. will be available when FactoryTalk Securityfor integration intofor you during 2005. Look different RSView products throughout the year.
onthehorizon
89
The VIEW
InControl
InControl magazine features the newest industrial control products from Rockwell Automation, as well as insightful articles about new technology, successful product applications, and answers to common product questions. To read and/or subscribe to InControl, visit www.ab.com/ industrialcontrols/incontrolMagazine/ index.html.
Sensors Today
Sensors Today magazine showcases the latest presence sensing technologies and discusses industry developments. To read and/or subscribe to Sensors Today, visit www.ab.com/sensors.
Safety Now
Rockwell Automation applies a broad range of engineering competencies to provide state-of-theart safety products and services. Safety Now magazine brings you the newest offerings to help you protect operators and tooling, satisfy global regulations and increase productivity. To read and/or subscribe to Safety Now, visit www.ab.com/safety.
Visualization News & Products
For further information about Rockwell Automation products, please contact your local Allen-Bradley or Rockwell Software authorized distributor.
October 2004