KING SUN INDUSTRY

KFT KFT

MAIN ADVANTAGES MAIN ADVANTAGES OF COUNTERFLOW


The counterflow configuration requires a smaller footprint while providing comparable
capacity to crossflow cooling towers with lower energy requirements, and is ideal for COOLING TOWERS
applications with restricted footprint availability.

CF

The low pressure water distribution spray system is located inside

FEATURES AND the tower and not exposed to the sunlight , hence no algae growth.

BENEFITS

KFT Counterflow Modular Type Cooling Tower


High Efficiency Cleaner Fill Packs & Distribution System
CF
The KFT counterflow towers optimize heat transfer The fill pack modules and distribution system on KFT towers
The fill packs are fully enclosed within the casing and completely
by letting the coldest water come in contact with are fully enclosed within the tower casing, and are entirely
protected from environmental pollutions and sunlight
the cooler entering ambient air and the warmest protected from UV exposure.
deterioration.
water contact the warmer saturated air, resulting in
greater evaporation and maximum heat-exchange. This feature also effectively reduces ice-formation, and
makes it easier for KFT to operate in winter.
Smaller Footprint
Counterflow towers are designed for greater air & Cleaner Water Basin CF

water contact than crossflow towers and require KFT features closely spaced PVC air-intake louvers, effectively The discharge air is less likely to re-enter the intake-louvers due
smaller plenum chamber area, so are smaller in preventing sunlight from reaching the cold water collection to their lower location which is just above the cold water basin.
dimensions and have smaller footprint. basin, contributing to less algae growth.

The modular air intake louvers are easily removable for access
Less Recirculation
to the cold water basin for cleaning.
Recirculation of hot saturated discharge air,
which drastically reduces cooling capacity, is less CF
prevalent on counterflow towers when compared Less Piping Cost
In Area A , warm saturated air meets hot water.
to crossflow towers due to smaller and lower air KFT towers are designed for single side water-inlet and outlet, A In Area B , cooler ambient air meets cold water.
intake configuration. requiring much less piping cost when compared to the
B
Therefore, heat-transfer is optimized.
double inlets on crossflow type towers.
Low Noise Level
KFT’s high quality “basin silencer” , positioned Minimal Drift Loss
directly above the cold water basin, efficiently KFT features high efficiency triple-pass PVC drift eliminator,
absorbs the sound of water droplets falling from effectively minimizing drifting loss.
fill packs into the cold water basin, resulting in low
overall noise level.
SIngle Side Water-Inlet & Outlet Piping.
Access for Maintenance Durable Construction
The simple structure and compact sizing of KFT Fabricated with high corrosion-resistant materials-- FRP
allows for maintenance from easy access on all four structure, casing & basin, KFT guarantees a long service life.
sides of the tower.

1 2
KING SUN INDUSTRY

KFT KFT
STRUCTURAL DRAWING OPTIONAL PARTS AND
MATERIALS

15

10
60
11
2

12
9

KFT Counterflow Modular Type Cooling Tower


5 13

6
4

7
1
8
2

1
3

14

Standard Specifications
3
No. Parts Material No. Parts Material
4
1 Basin F.R.P. 9 Fan stack F.R.P.

2 Fill P.V.C. 10 Motor


No. Part Name Standard material Other material
3 Basin silencer Nylon 11 Reducer
1 Ladder cage H.D.G. Steel SUS304, SUS316
4 Casing F.R.P. 12 Fan
2 Safety handrail H.D.G. Steel SUS304, SUS316
5 Drift eliminator P.V.C. 13 Water inlet
3 Spring isolator support H.D.G. Steel SUS304
6 Distribution pipe P.V.C. 14 Water outlet 4 Spring isolator H.D.G. Steel SUS304
7 Nozzle A.B.S. 15 Motor support H.D.G. Steel H.D.G.Steel Hot Dip Galvanized Steel P.V.C. Polyvinyl Chloride
SUS304 Stainless steel Grade 304 F.R.P Fiberglass Reinforced Plastics
8 Intake louver P.V.C. SUS316 Stainless steel Grade 316

3 4
KING SUN INDUSTRY

KFT KFT
SELECTION TABLE SPECIFICATIONS
Medium High KFT-40~50 SINGLE CELL KFT-60~350 SINGLE CELL
Type Normal Temperature Type Temperature Type Temperature Type
Wet Bulb 27(℃) 28(℃) 29(℃) 30(℃) 27(℃) 28(℃) 27(℃) 28(℃)
Temperature
℃ 37℃ 37.5℃ 37℃ 37.5℃ 37℃ 37.5℃ 38℃ 38.5℃ 42℃ 42℃ 60℃ 60℃ D
l/min
| | | | | | | | | | | |
32℃ 32℃ 32℃ 32℃ 32℃ 32℃ 33℃ 33℃ 32℃ 32℃ 35℃ 35℃ D
Model

FH

FH
40 520 480 440 415 375 355 395 375 340 300 340 330

50 650 600 550 530 470 440 500 470 400 370 400 390

KFT Counterflow Modular Type Cooling Tower


60 780 720 660 615 560 520 590 560 480 450 520 490

W
H
W

H
70 910 840 770 740 660 620 700 660 580 530 600 570
L L
80 1040 962 892 826 733 700 788 743 655 570 660 610

100 1300 1210 1120 1025 925 829 937 877 830 729 790 750

125 1625 1513 1398 1304 1152 1104 1237 1166 1034 940 1070 1000
Heat Water Dry Operating
150 1950 1814 1680 1563 1391 1330 1495 1415 1251 1093 1260 1190 Model duty flow Dimension Motor Fan Head Weight Weight
Cells
KFT kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg
175 2275 2108 1963 1837 1624 1541 1728 1634 1460 1310 1510 1430
40 40-C1 156000 520 1520 1520 2932 320 2*1 1.5*1 900 3.7 490 980
200 2600 2419 2241 2114 1849 1786 1990 1895 1659 1456 1760 1660
50 50-C1 195000 650 1520 1520 2932 320 2*1 1.5*1 900 3.7 490 980
225 2925 2736 2514 2380 2100 1990 2220 2090 1890 1680 1950 1830
60 60-C1 234000 780 2130 2130 3380 420 2*1 1.5*1 1500 3.9 700 1500
250 3250 2995 2791 2610 2330 2180 2480 2310 2090 1860 2140 2040 70 70-C1 273000 910 2130 2130 3380 420 2*1 1.5*1 1500 3.9 700 1500

300 3900 3634 3355 3135 2810 2605 2910 2760 2488 2220 2520 2395 80 80-C1 312000 1040 2130 2130 3380 420 2*1 1.5*1 1500 3.9 700 1500

350 4550 4223 3932 3696 3330 3130 3486 3293 2952 2615 3050 2890
100 100-C1 390000 1300 2130 2130 3380 470 3*1 2.2*1 1500 4 730 1580
400 5200 4832 4490 4250 3800 3518 3960 3748 3350 2992 3450 3220
200 100-C2 780000 2600 3960 2130 3380 470 3*2 2.2*2 1500 4 1410 2960
450 5850 5480 5130 4860 4280 4039 4505 4275 3899 3455 3940 3680

500 6500 6100 5660 5330 4788 4520 5023 4780 4356 3880 4440 4230
125 125-C1 487500 1625 2415 2415 3620 470 3*1 2.2*1 1800 4.2 890 2000
600 7800 7280 6749 6340 5613 5330 5960 5650 5100 4550 5250 4950 250 125-C2 975000 3250 4550 2415 3620 470 3*2 2.2*2 1800 4.2 1640 3790

700 9100 8470 7965 7350 6725 6300 7000 6660 6127 5482 6220 5930

800 10400 9710 8984 8520 7650 7270 8090 7680 7000 6280 7270 6930 150 150-C1 585000 1950 2415 2415 3620 500 5*1 3.7*1 1800 4.4 970 2130

300 150-C2 1170000 3900 4550 2415 3620 500 5*2 3.7*2 1800 4.4 1800 4050
900 11700 10920 10186 9600 8680 8240 9160 8700 7930 7080 8160 7700

1000 13000 12180 11430 10710 9756 9200 10100 9700 8965 8050 9250 8840
175 175-C1 682500 2275 2740 2740 3910 635 5*1 3.7*1 2100 4.4 1190 2690
1 Please verify the wet bulb temperature at the geographical location where the tower is to be installed before 350 175-C2 1365000 4550 5180 2740 3910 635 5*2 3.7*2 2100 4.4 2210 5210
consulting the Selection Table.
2 Should the design temperature condition not be within the selection temperature range of the table, 525 175-C3 2047500 6825 7620 2740 3910 635 5*3 3.7*3 2100 4.4 3230 7730
please contact your King Sun representative.
1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton.
3 In order to select the cooling tower model no., the data below are necessary:
. Water flow rate… LPM, GPM, m3/hr 2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC.
. Entering temperature… water temperature into the tower
. Leaving temperature… water temperature required out of the tower
. WBT… wet bulb temperature

5 6
KING SUN INDUSTRY

KFT KFT
SPECIFICATIONS SPECIFICATIONS
KFT-60~350 SINGLE CELL KFT-60~350 SINGLE CELL DIAGRAM OF MODULAR CELLS

FH
D

W
FH
L
W

KFT Counterflow Modular Type Cooling Tower


D
H

FH
H

H
L L

Heat Water Dry Operating Heat Water Dry Operating


Model duty flow Dimension Motor Fan Head Weight Weight Model duty flow Dimension Motor Fan Head Weight Weight
Cells Cells
KFT kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg
KFT kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg

200 200-C1 780000 2600 2740 2740 3910 635 7.5*1 5.5*1 2100 4.6 1280 2830 1000 250-C4 3900000 13000 12500 3350 3930 635 7.5*4 5.5*4 2400 4.5 5320 12040

400 200-C2 1560000 5200 5180 2740 3910 635 7.5*2 5.5*2 2100 4.6 2450 5540 1250 250-C5 4875000 16250 15550 3350 3930 635 7.5*5 5.5*5 2400 4.5 6950 14500

600 200-C3 2340000 7800 7620 2740 3910 635 7.5*3 5.5*3 2100 4.6 3620 8250

800 200-C4 3120000 10400 10060 2740 3910 635 7.5*4 5.5*4 2100 4.6 4790 10960 300 300-C1 1170000 3900 3350 3350 4160 670 10*1 7.5*1 2400 4.8 1770 3770
1000 200-C5 3900000 13000 12500 2740 3910 635 7.5*5 5.5*5 2100 4.6 5960 13670
600 300-C2 2340000 7800 6400 3350 4160 670 10*2 7.5*2 2400 4.8 2980 7330

900 300-C3 3510000 11700 9450 3350 4160 670 10*3 7.5*3 2400 4.8 4190 10890
225 225-C1 877500 2925 2740 2740 3910 635 7.5*1 5.5*1 2100 4.7 1320 2910
1200 300-C4 4680000 15600 12500 3350 4160 670 10*4 7.5*4 2400 4.8 5400 14450
450 225-C2 1755000 5850 5180 2740 3910 635 7.5*2 5.5*2 2100 4.7 2530 5700
1500 300-C5 5850000 19500 15550 3350 4160 670 10*5 7.5*5 2400 4.8 6610 18010
675 225-C3 2632500 8775 7620 2740 3910 635 7.5*3 5.5*3 2100 4.7 3740 8490

900 225-C4 3510000 11700 10060 2740 3910 635 7.5*4 5.5*4 2100 4.7 4950 11280
350 350-C1 1365000 4550 3350 3350 4560 670 10*1 7.5*1 2400 4.9 1830 3890
1125 225-C5 4387500 14625 12500 2740 3910 635 7.5*5 5.5*5 2100 4.7 6160 14070
700 350-C2 2730000 9100 6400 3350 4560 670 10*2 7.5*2 2400 4.9 3100 7530

1050 350-C3 4095000 13650 9450 3350 4560 670 10*3 7.5*3 2400 4.9 4370 11170
250 250-C1 975000 3250 3350 3350 3930 635 7.5*1 5.5*1 2400 4.5 1520 3460
1400 350-C4 5460000 18200 12500 3350 4560 670 10*4 7.5*4 2400 4.9 5640 14810
500 250-C2 1950000 6500 6400 3350 3930 635 7.5*2 5.5*2 2400 4.5 2460 6720

750 250-C3 2925000 9750 9450 3350 3930 635 7.5*3 5.5*3 2400 4.5 3690 9580 1750 350-C5 6825000 22750 15550 3350 4560 670 10*5 7.5*5 2400 4.9 6910 18450

1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton. 1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton.
2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC. 2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC.

7 8
KING SUN INDUSTRY

KFT KFT
SPECIFICATIONS SPECIFICATIONS
KFT-400~500 SINGLE CELL KFT-600~1000 SINGLE CELL DIAGRAM OF MODULAR CELLS

FH

W
D L
W

FH
H D

KFT Counterflow Modular Type Cooling Tower


W

FH
H

H
L L

Heat Water Dry Operating Heat Water Dry Operating


Model duty flow Dimension Motor Fan Head Weight Weight Model duty flow Dimension Motor Fan Head Weight Weight
Cells Cells
KFT KFT kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg
kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg

400 400-C1 1560000 5200 3960 3960 4820 750 15*1 11*1 3000 5.2 3060 7350 600 600-C1 2340000 7800 4825 4825 4920 841 20*1 15*1 3400 5.2 4687 9768

800 400-C2 3120000 10400 7620 3960 4820 750 15*2 11*2 3000 5.2 4900 13500 1200 600-C2 4680000 15600 9400 4825 4920 841 20*2 15*2 3400 5.2 8687 18726

1200 400-C3 4680000 15600 11280 3960 4820 750 15*3 11*3 3000 5.2 6740 19800 1800 600-C3 7020000 23400 13975 4825 4920 841 20*3 15*3 3400 5.2 12727 27786

1600 400-C4 6240000 20800 14940 3960 4820 750 15*4 11*4 3000 5.2 8580 26100 2400 600-C4 9360000 31200 18550 4825 4920 841 20*4 15*4 3400 5.2 16727 36805

2000 400-C5 7800000 26000 18600 3960 4820 750 15*5 11*5 3000 5.2 10420 32500 3000 600-C5 11700000 39000 23125 4825 4920 841 20*5 15*5 3400 5.2 20757 45855

450 450-C1 1755000 5850 3960 3960 5050 750 15*1 11*1 3000 5.4 3290 7990 700 700-C1 2730000 9100 5740 5740 4920 841 20*1 15*1 3600 5.3 5426 12327

900 450-C2 3510000 11700 7620 3960 5050 750 15*2 11*2 3000 5.4 5420 14810 1400 700-C2 5460000 18200 11230 5740 4920 841 20*2 15*2 3600 5.3 10074 23698

1350 450-C3 5265000 17550 11280 3960 5050 750 15*3 11*3 3000 5.4 7690 21700 2100 700-C3 8190000 27300 16720 5740 4920 841 20*3 15*3 3600 5.3 14763 35200

1800 450-C4 7020000 23400 14940 3960 5050 750 15*4 11*4 3000 5.4 9820 28600 2800 700-C4 10920000 36400 22210 5740 4920 841 20*4 15*4 3600 5.3 19410 46659

2250 450-C5 8775000 29250 18600 3960 5050 750 15*5 11*5 3000 5.4 11950 35600 3500 700-C5 13650000 45500 27700 5740 4920 841 20*5 15*5 3600 5.3 24087 58149

500 500-C1 1950000 6500 3960 3960 5450 750 15*1 11*1 3000 5.6 3360 8050 800 800-C1 3120000 10400 5740 5740 5320 1026 25*1 18*1 3600 5.4 5733 12964

1000 500-C2 3900000 13000 7620 3960 5450 750 15*2 11*2 3000 5.6 5560 14950 1600 800-C2 6240000 20800 11230 5740 5320 1026 25*2 18*2 3600 5.4 10653 24917

1500 500-C3 5850000 19500 11280 3960 5450 750 15*3 11*3 3000 5.6 7760 21900 2400 800-C3 9360000 31200 16720 5740 5320 1026 25*3 18*3 3600 5.4 15617 37014

2000 500-C4 7800000 26000 14940 3960 5450 750 15*4 11*4 3000 5.6 9960 28910 3200 800-C4 12480000 41600 22210 5740 5320 1026 25*4 18*4 3600 5.4 20537 49066

2500 500-C5 9750000 32500 18600 3960 5450 750 15*5 11*5 3000 5.6 12160 35970 4000 800-C5 15600000 52000 27700 5740 5320 1026 25*5 18*5 3600 5.4 25490 61152

1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton. 1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton.
2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC. 2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC.

9 10
KING SUN INDUSTRY

KFT KFT
SPECIFICATIONS PIPE CONNECTION DETAILS
KFT-600~1000 SINGLE CELL DIAGRAM OF MODULAR CELLS KFT -40~350 KFT-400~500 KFT-600~1000

De

De De

W
D
L
FH

KFT Counterflow Modular Type Cooling Tower


D
W

FH
H

Ba
L O Ba O
Q
Q S S
Dr S Dr Dr

Heat Water Dry Operating Automatic Quick


Model duty flow Dimension Motor Fan Head Weight Weight RT Inlet Outlet Make up Make up Over flow Drain
Cells De S O Dr
KFT Ba Q
kcal/h 1/min L W H FH Hp kW Dφm/m m kg kg
40 3"(80A) 3"(80A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)
900 900-C1 3510000 11700 6655 6655 4875 1026 30*1 22*1 4270 5.4 6716 15694 50 3"(80A) 3"(80A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)
60 4"(100A) 4"(100A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)
1800 900-C2 7020000 23400 13060 6655 4875 1026 30*2 22*2 4270 5.4 12535 30249
70 4"(100A) 4"(100A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)

2700 900-C3 10530000 35100 19465 6655 4875 1026 30*3 22*3 4270 5.4 18398 44969 80 4"(100A) 4"(100A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)
100 4"(100A) 4"(100A) 3/4"(20A) 3/4"(20A) 1"(25A) 1"(25A)
3600 900-C4 14040000 46800 25870 6655 4875 1026 30*4 22*4 4270 5.4 24217 59645 125 5"(125A) 5"(125A) 1"(25A) 1"(25A) 2"(50A) 2"(50A)
150 6"(150A) 6"(150A) 1"(25A) 1"(25A) 2"(50A) 2"(50A)
4500 900-C5 17550000 58500 32275 6655 4875 1026 30*5 22*5 4270 5.4 30065 74350
175 6"(150A) 6"(150A) 1"(25A) 1"(25A) 2"(50A) 2"(50A)
200 6"(150A) 6"(150A) 1 1/4"(32A) 1 1/4"(32A) 2"(50A) 2"(50A)
225 8"(200A) 8"(200A) 1 1/4"(32A) 1 1/4"(32A) 2"(50A) 2"(50A)

1000 1000-C1 3900000 13000 6655 6655 5275 1026 30*1 22*1 4270 5.6 6895 16313 250 8"(200A) 8"(200A) 1 1/4"(32A) 1 1/4"(32A) 2"(50A) 2"(50A)
300 8"(200A) 8"(200A) 1 1/4"(32A) 1 1/4"(32A) 2"(50A) 2"(50A)
2000 1000-C2 7800000 26000 13060 6655 5275 1026 30*2 22*2 4270 5.6 12890 31484 350 8"(200A) 8"(200A) 1 1/4"(32A) 1 1/4"(32A) 2"(50A) 2"(50A)
400 8"(200A) 8"(200A) 1 1/2"(40A) 1 1/2"(40A) 2"(50A) 2"(50A)
3000 1000-C3 11700000 39000 19465 6655 5275 1026 30*3 22*3 4270 5.6 18933 46824
450 10"(250A) 10"(250A) 1 1/2"(40A) 1 1/2"(40A) 2"(50A) 2"(50A)
500 10"(250A) 10"(250A) 1 1/2"(40A) 1 1/2"(40A) 2"(50A) 2"(50A)
4000 1000-C4 15600000 52000 25870 6655 5275 1026 30*4 22*4 4270 5.6 24928 62116
600 10"(250A) 10"(250A) 2"(50A) 2"(50A) 2"(50A) 2"(50A)
5000 1000-C5 19500000 65000 32275 6655 5275 1026 30*5 22*5 4270 5.6 30955 77440 700 12"(300A) 12"(300A) 2"(50A) 2"(50A) 2"(50A) 2"(50A)
800 12"(300A) 12"(300A) 2"(50A) 2"(50A) 2"(50A) 2"(50A)
1 The normal cooling capacity of KFT towers is based on 37oC HWT, 32oC CWT, 27oC WBT and 13LPM per ton.
900 14"(350A) 14"(350A) 2"(50A) 2"(50A) 2"(50A) 2"(50A)
2 The water flow rate (LPM) on the table is based on temperature condition: 37oC-32oC-27oC.
1000 14"(350A) 14"(350A) 2"(50A) 2"(50A) 2"(50A) 2"(50A)

1 If there’s a need for equalization connection, please contact your King Sun representative.
2 For high temperature applications, there may possibly exist a need to modify the pipe diameters on the water inlet and
water outlet. For this type of application, please contact your King Sun representative for advice.

11 12
KING SUN INDUSTRY

KFT
KFT
FOUNDATION DETAILS
FOUNDATION DETAILS
RT
40 50 60 70 80 100 125 150 175
Location
A 1270 1270 1840 1840 1840 1840 2155 2155 2450

1 Cell B 970 970 1540 1540 1540 1540 1855 1855 2150

KFT-40~50 SINGLE CELL KFT-60~350 SINGLE CELL K1 970 970 775 775 775 775 928 928 1080

1 Cell 4 4 5 5 5 5 5 5 5
300 2 Cells 6 6 8 8 8 8 8 8 8

150
A
300 Anchor Bolts
150

3 Cells 8 8 11 11 11 11 11 11 11

300
50
M16*200L

A
4 Cells 10 10 14 14 14 14 14 14 14

300
150
300

KFT Counterflow Modular Type Cooling Tower


A
B

A
5 Cells 12 12 17 17 17 17 17 17 17

B
300
A

B 1000 B A-A View


50
300

150
250

1000
400

RT
A

K1 200 225 250 300 350 400 450 500


Location

300
A-A View K1 K1 A 2450 2450 3060 3060 3060 4140 4140 4140
B-B View
1 Cell B 2150 2150 2760 2760 2760 1870 1870 1870

K1 1080 1080 1385 1385 1385 1870 1870 1870

1 Cell 5 5 5 5 5 16 16 16

2 Cells 8 8 8 8 8 26 26 26
Anchor Bolts 3 Cells 11 11 11 11 11 36 36 36
M16*200L
4 Cells 14 14 14 14 14 46 46 46
KFT-400~500 SINGLE CELL KFT-600~1000 SINGLE CELL 5 Cells 17 17 17 17 17 56 56 56
400
200

RT
200
A

600 700 800 900 1000


Location
A 5055 5970 5970 6885 6885
A

400
B 1565 1870 1870 2175 2475
B

400 800 100


200

1 Cell C 1525 1830 1830 2135 2135


A
C
800
400

400

K1 1525 1830 1830 2135 2135


B B A-A View
K2 1550 1855 1855 2160 2160
B

800 1 Cell 16 16 16 16 16
50
630

K2 K1 K2
250 2 Cells 28 28 28 28 28
K1 K1 500
B-B View Anchor Bolts 3 Cells 40 40 40 40 40
M16*200L
4 Cells 52 52 52 52 52

5 Cells 64 64 64 64 64

In the event that spring mount vibration isolators are to be used, the foundation detail would need to be modified.
For this type of application, please contact your King Sun representative for advice.

13 14