Data Communication - 8
Data Communication - 8
Data Communication - 8
Chapter 4
Digital Transmission
4.1
4-2 ANALOG
ANALOG--TO
TO--DIGITAL CONVERSION
4.2
PCM
PCM consists of three steps to digitize an
analog signal:
1. Sampling
2. Quantization
3. Binary encoding
Before we sample, we have to filter the
signal to limit the maximum frequency of
the signal as it affects the sampling rate.
Filtering should ensure that we do not
distort the signal, ie remove high frequency
components that affect the signal shape.
4.3
Figure 4.21 Components of PCM encoder
4.4
Sampling
Analog signal is sampled every TS secs.
Ts is referred to as the sampling interval.
fs = 1/Ts is called the sampling rate or
sampling frequency.
There are 3 sampling methods:
Ideal - an impulse at each sampling instant
Natural - a pulse of short width with varying
amplitude
Flattop - sample and hold, like natural but with
single amplitude value
The process is referred to as pulse amplitude
modulation PAM and the outcome is a signal
with analog (non integer) values
4.5
Figure 4.22 Three different sampling methods for PCM
4.6
Note
4.7
Figure 4.23 Nyquist sampling rate for low-pass and bandpass signals
4.8
Example 4.6
4.10
Example 4.7
4.12
Example 4.8
4.13
Example 4.9
4.14
Example 4.10
Solution
The bandwidth of a low-pass signal is between 0
and f, where f is the maximum frequency in the
signal. Therefore, we can sample this signal at 2
times the highest frequency (200 kHz). The
sampling rate is therefore 400,000 samples per
second.
4.15
Example 4.11
Solution
We cannot find the minimum sampling rate in this
case because we do not know where the
bandwidth starts or ends. We do not know the
maximum frequency in the signal.
4.16
Quantization
Sampling results in a series of pulses of
varying amplitude values ranging between
two limits: a min and a max.
The amplitude values are infinite between the
two limits.
We need to map the infinite amplitude values
onto a finite set of known values.
This is achieved by dividing the distance
between min and max into L zones, each of
height
= (max - min)/L
4.17
Quantization Levels
4.18
Quantization Zones
Assume we have a voltage signal with
amplitutes Vmin=-20V and Vmax=+20V.
We want to use L=8 quantization levels.
Zone width = (20 - -20)/8 = 5
The 8 zones are: -20 to -15, -15 to -10,
-10 to -5, -5 to 0, 0 to +5, +5 to +10,
+10 to +15, +15 to +20
The midpoints are: -17.5, -12.5, -7.5, -
2.5, 2.5, 7.5, 12.5, 17.5
4.19
Assigning Codes to Zones
Each zone is then assigned a binary code.
The number of bits required to encode the
zones, or the number of bits per sample as it
is commonly referred to, is obtained as
follows:
nb = log2 L
Given our example, nb = 3
The 8 zone (or level) codes are therefore:
000, 001, 010, 011, 100, 101, 110, and 111
Assigning codes to zones:
000 will refer to zone -20 to -15
001 to zone -15 to -10, etc.
4.20
Figure 4.26 Quantization and encoding of a sampled signal
4.21
Quantization Error
When a signal is quantized, we introduce an
error - the coded signal is an approximation
of the actual amplitude value.
The difference between actual and coded
value (midpoint) is referred to as the
quantization error.
The more zones, the smaller which results
in smaller errors.
BUT, the more zones the more bits required
to encode the samples -> higher bit rate
4.22
Quantization Error and SNQR
Signals with lower amplitude values will suffer
more from quantization error as the error
range: /2, is fixed for all signal levels.
Non linear quantization is used to alleviate
this problem. Goal is to keep SNQR fixed for
all sample values.
Two approaches:
The quantization levels follow a logarithmic curve.
Smaller ’s at lower amplitudes and larger’s at
higher amplitudes.
Companding: The sample values are compressed
at the sender into logarithmic zones, and then
expanded at the receiver. The zones are fixed in
height.
4.23
Bit rate and bandwidth
requirements of PCM
The bit rate of a PCM signal can be calculated form
the number of bits per sample x the sampling rate
Bit rate = nb x fs
The bandwidth required to transmit this signal
depends on the type of line encoding used. Refer to
previous section for discussion and formulas.
A digitized signal will always need more bandwidth
than the original analog signal. Price we pay for
robustness and other features of digital transmission.
4.24
Example 4.14
Solution
The human voice normally contains frequencies
from 0 to 4000 Hz. So the sampling rate and bit
rate are calculated as follows:
4.25
PCM Decoder
4.26
Figure 4.27 Components of a PCM decoder
4.27
Example 4.15
4.28
Delta Modulation
This scheme sends only the difference
between pulses, if the pulse at time tn+1 is
higher in amplitude value than the pulse at
time tn, then a single bit, say a “1”, is used to
indicate the positive value.
If the pulse is lower in value, resulting in a
negative value, a “0” is used.
This scheme works well for small changes in
signal values between samples.
If changes in amplitude are large, this will
result in large errors.
4.29
Figure 4.28 The process of delta modulation
4.30
Figure 4.29 Delta modulation components
4.31
Figure 4.30 Delta demodulation components
4.32
Delta PCM (DPCM)
4.33
4-3 TRANSMISSION MODES
4.34
Figure 4.31 Data transmission and modes
4.35
Figure 4.32 Parallel transmission
4.36
Figure 4.33 Serial transmission
4.37
Note
4.38
Note
4.39
Figure 4.34 Asynchronous transmission
4.40
Note
4.41
Figure 4.35 Synchronous transmission
4.42
Isochronous
4.43