Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Technical Services

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Avista Technologies offers an array of technical and support services

which can be effective tools in understanding and improving the


performance of reverse osmosis membranes. These include:

Laboratory Services:

* Water Analysis: With half a gallon (2 liters) of RO feedwater, this test


provides the cation and anion data necessary to obtain an accurate and site
specific antiscalant recommendation.

* Foulant Identification: This analysis requires a membrane leaf which is


examined to determine the nature of any foulants present and their effect on
the membrane. Potential foulants can include scale, biological matter,
metals, etc.

* Coagulant Recommendation and Dose: Requires a minimum of five


gallons (20 liters) of the feedwater to the multimedia or sand filter. From
this, the optimum RoQuest coagulant and dosage is determined. This
provides the most efficient and cost effective coagulation within the filter.

* Flocculant Recommendation and Dose: A minimum five gallon (20 liter)


sample of the feedwater to the clarifier/flocculator is sent to Avista and used
by our personnel to complete a jar test procedure. The results determine the
type and specific dose of the most effective RoQuest coagulant/flocculant for
that application.

Membrane Autopsy:
The physical dissection of an RO membrane and the laboratory analysis of its
foulants can be one of the most definitive methods of troubleshooting an RO
system. An Avista autopsy includes a wide range of procedures, as shown USA
below, and concludes with our summary and recommendations: Avista Technologies Inc.
San Marcos, CA 92069
Phone: 760 744-0536
External and internal visual examination
Fax: 760 744-0619
• Wet test of the element
• Chemical identification of surface foulants using United Kingdom
• FTIR spectrometer Avista Technologies (UK) Ltd.
• Energy Dispersive X-Ray Spectrometer (EDX) Phone: 44 (0) 131 4496677
• Scanning Electron Microscope (SEM) Fax: 44 (0) 131 4495599
• Loss on Ignition test Mexico
• Cell and Dye test Phone: 011 52 686 5687393
• Fujiwara Test Fax: 011 52 686 5687206
Brazil
Off-Site Membrane Cleaning: AcquaLease
Avista Technologies cleans both 4" and 8" diameter RO membranes in our Phone/Fax: 011 55 11 5641 3887
facility. Each membrane is pre and post tested to confirm the cleaning results.
They are then packaged in new boxes and bags and returned to the customer. China
This service is valuable for those customers who do not have cleaning Beijing Newtek International Inc.
equipment on site, do not have adequate equipment, are subject to severe Tel: 010-6480-1119
discharge restrictions.
www.avistatech.com

You might also like