Ves Swimming Pool Ventilation
Ves Swimming Pool Ventilation
Ves Swimming Pool Ventilation
Ventilation
ffDesign assistance for new installations
5
2
Prewired/Fitted
Controls
Demand
Ventilation
Case
Construction
Filters Air Quality Thyristor
Heater
Energy Saving
Intelligent controls enhance
performance whilst saving
Energy
Efficient Fans
Speed
Control
Plug & Play Humidity Temperature Heat
Recovery
energy and money.
Premium efficiency, low energy swimming pool solutions
Heat recovery
2 Face and by-pass dampers
1 f Plate heat exchanger is generously
sized to achieve a minimum efficiency
2 f The plate heat exchanger section
incorporates four independently
of 70% controlled face and by-pass dampers
f Plate heat exchanger heat recovery to facilitate accurate temperature and
section with integrated air mixing humidity control
facility to optimise energy savings f Powder coated damper blade
f Virgin plastic or anodised matrix f Polyurethane intermeshing gears
resistant to the aggressive chlorinated f IP66 damper actuators
air
f Fully integrated mixing section with
by-pass
f Powder coated drain trays
Panels Options
f Fixed and access panels are f Built in or duct mounted
constructed from high grade attenuators
galvanised sheet steel f DX or chilled water-cooling
f Epoxy powder coated paint finish f Choice of colour
to RAL 7004
f Weatherproofed pitched roof on
f High density mineral wool infill for external models
greater thermal performance
3
Swimming pool ventilation
design.. create.. leisure environments
Leisure centres
Schools
“Swimming pools
are inherently expensive
to run, typically accounting for
over half the budget
of a leisure centre”
4
Premium efficiency, low energy swimming pool solutions
Ventilation process
To maintain optimum, comfortable conditions, a swimming pool requires a
ventilation process that can control temperature and humidity.
To maximise energy savings, VES pool air handling units use a heat recovery
plate heat exchanger and integrated mixing selection to recovery up to 85%
of energy that would otherwise be lost.
VES swimming pool packages are ideal for leisure centres, schools and other
commercial establishments. Our portfolio of projects is extensive - see the
case studies on the inside back cover. More can be found at ves.co.uk.
Hotels
5
Swimming pool ventilation
Modes of operation
All modes are automatic with no input required from the end user. Sensors constantly monitor
humidity and temperature, sending signals to the control system to adjust internal dampers and
fan speed to meet the individual demands of the pool.
Each mode is seamless and configured to maintain optimum conditions quietly and efficiently.
Recirculation mode
When the pool is not in use, typically night time,
fans automatically adjust to a lower speed and
the AHU adopts full recirculation mode with a
normal amount of fresh air input to maintain
conditions.
Winter mode
A smaller proportion of fresh air passes through
the heat exchanger and mixes with a higher
proportion of recirculated air from the pool. This
is heated by LPHW heating coil when additional
demand for heating is required.
Normal mode
Heat is recovered from the pool by passing air
over the plate heat exchanger. This heat is
transferred to incoming fresh air. A proportion of
air is recirculated back into the supply air stream
to prevent unnecessary evaporated from the
pool.
6
Premium efficiency, low energy swimming pool solutions
To help overcome all these issues we can offer the VES pools
package
This includes the following works and services to help ensure a smooth and trouble free
project is delivered.
f We will work with the project team to produce a programme of works that will ensure down
time and disruption are kept to an absolute minimum. We may be able to keep the pool
open with the use of temporary ventilation or working out of hours, meaning no loss of
revenue
f We will undertake full on-site technical measurements and then design a unit that perfectly
fits the available space, taking full responsibility for correct fit and handings
f Rip-out the old unit
f New site flatpack or sectional installation
f Commissioning of the unit and controls once installed
7
Swimming pool ventilation
Or refurbish your existing AHU for a cost effective solution
VES pioneered and is the market leader in on-site refurbishment of existing air-handling
equipment regardless of make or model.
Unit condition before Before - inefficient belt driven fans Before - dampers siezed
Completed refurbished unit After - new energy efficient plug fan After - replacement dampers and
actuators
Typically, the cost of refurbishment is far lower than replacing with new. Refurbishment is often
a quicker and more flexible approach to replacing. The works can also be undertaken out of
hours meaning less potential down time, which is absolutely essential for a leisure centre.
8
Premium efficiency, low energy swimming pool solutions
Situation
The facilities maintenance contractor asked VES to review
the state of the existing equipment and installation and make
recommendations to improve the conditions and for energy
savings. The swimming pool supply and extract air-handling
equipment was in poor condition, with no heat recovery at all.
We also found un-lagged heating ductwork.
Solution
VES engineers assisted the contractor with site works,
including:
f Installing a brand new supply and extract AHU with a
high-efficiency crossflow heat exchanger
f Manufacturing and fitting new controls with inverters that
automatically reduce the fan speed out of hours
f Aluclad lagging heating ductwork to minimise heat loss
f Replacing another unit serving the gym with a heat
recovery AHU located on the same platform
f All craneage plus cutting up and removing the old
equipment
Outcome
The addition of heat recovery and other energy saving
measures made such a substantial impact on heating de-
mand that the main pool direct gas fired heater could be
downrated from 250 kW to a 100kW heater - a huge 60%
reduction.
A range of other case studies can be found on our website, showing how
VES helped saved energy, money and optimised existing units’
performance. Read more at ves.co.uk.
9
Other products and services from the
complete range of VES HVAC solutions
Duct Fans
f In-line centrifugal, with forward or backward curved
impellers
f Round, axial and mixed flow fans
f Fitted silencers available on all units
f Manual and automatic speed controllers available
Twin Fans
f For ceiling void, plantroom and weatherproof
f Many models and configurations
f Fitted auto-changeover system
Hybrid Units
f Natural ventilation enhanced by a low power fan
f Utilises a combination of automatic mechanical ventilation
and manually operated windows to achieve classroom
comfort conditions
f Simple user interface with indication of operating mode
f Slimline, lightweight construction, saving space and easing
installation
f Available in a range of sizes with the ability to add heating
coils when required
Control Panels
f Off the shelf and built to order panels
f Air quality sensors and energy savers
f Intelligent control software
f A range of remotes including touch screen
Noise Control
f Matching silencers available for all ventilation products
f Silencers designed to meet noise criteria
f Cleanable silencers
f Weatherproof silencers
Member