RigExpert®
AA-600
Antenna Analyzer
0.1 to 600 MHz
AA-1000
Antenna Analyzer
0.1 to 1000 MHz
AA-1400
Antenna Analyzer
0.1 to 1400 MHz
User's manual
Machine Translated by Google
Machine Translated by Google
table of contents
3
Machine Translated by Google
1. Description
4
Machine Translated by Google
2. Specifications
Frequency range: 0.1 to 600 MHz – AA-600
0.1 to 1000 MHz – AA-1000
0.1 to 1400 MHz – AA-1400
Frequency entry: 1 kHz resolution Measurement
for 25, 50, 75 and 100-Ohm systems SWR
measurement range: 1 to 100 in numerical mode, 1 to
10 in graph mode SWR
display: numerical or easily-readable bar R and X
range: 0…10000, -10000…10000 in numerical mode, 0…1000,
-1000…1000 in graph mode
Display modes:
- SWR at single or multiple frequencies
- SWR, return loss, R, X, Z, L, C at single frequency
- SWR graph, 80 points
- R, X graph, 80 points
- Smith/polar chart, 80 points
- TDR (Time Domain Reflectometer) graph
RF output:
- Connector type: N -
Output signal shape: rectangular, 0.1 to 200 MHz. For higher
frequencies, harmonics of the main signal are used.
- Output power: -10 dBm (at 50 Ohm load)
Power:
- Three 1.5V, alkaline batteries, type AA -
Three 1.2V, 1800…3000 mA·h, Ni-MH batteries, type AA -
Max. 3 hours of continuous measurement, max. 2 days in stand-by
mode when fully charged batteries are used - When the analyzer
is connected to a PC or a DC adapter with USB socket, it takes power
from these sources
Interface:
- 320x240 color TFT display -
6x3 keys on the waterproof keypad
- Multilingual menus and help screens
- USB connection to a personal computer
5
Machine Translated by Google
3. Precautions
6
Machine Translated by Google
4. Operation
Do not: mix new and old batteries; use batteries of different types at the same time;
overheat or disassemble batteries; short circuit batteries; try to re-charge alkaline
batteries.
To charge Ni-MH batteries, use charging adapters for this type of batteries. For
longer battery life, it is recommended to use an adapter which charges each battery
separately.
Any leaks of electrolyte from the batteries may seriously damage the analyzer.
Remove batteries if the analyzer is not being used for a long period of time. Store
batteries in a dry cool place.
The on-screen menu system of RigExpert antenna analyzers provides a simple but
effective way to control the entire device.
The analyzer may stay turned on when you connect a cable to its antenna connector (or
when you disconnect a cable). Plug the cable into the antenna connector, and then
tighten the rotating sleeve. The rest of the connector, as well as the cable, should remain
stationary.
Important: If you twist other parts of the connector when tightening or loosening,
damage may easily occur. Twisting is not allowed by design of the N-connector.
7
Machine Translated by Google
The Main menu contains a brief list of available commands. By pressing keys on the
keypad, you may enter corresponding measurement modes, set up additional
parameters, etc.
Pressing the (function) key will immediately list additional commands:
There is a power indicator in the top-right corner of the Main menu screen:
• The battery indicator shows battery discharge level. When the battery voltage is
too low, this indicator starts flashing. • The USB icon is displayed when the
analyzer is plugged to a personal computer or to a DC adapter with USB socket.
Important: RigExpert antenna analyzers are self-documenting. Pressing the (help) key
will open a help screen with a list of available hot keys for the current mode.
8
Machine Translated by Google
The SWR mode (press the key in the Main menu) displays the SWR bar as well as
the numerical value of this parameter:
Set the desired frequency (the key) or change it with left or right arrow keys.
Do not forget to press (ok) key to start or stop measurement. The flashing
the antenna icon in the top-right corner indicates when the measurement is started.
pressing the (help) key will show a list of all available commands for this mode:
9
Machine Translated by Google
This task usually involves two persons; one adjusting the antenna and the other shouting
out the SWR value as it changes at the far end of the feedline.
There is an easier way to do the same job by using the SWR2Air mode. The result of SWR
measurement is transmitted on a user specified frequency where it can be heard with a portable
HF or VHF FM radio. The length of audio signal coming from the loudspeaker of the portable
radio depends on the value of measured SWR.
The SWR2Air mode is activated by pressing + key combination in the SWR allows setting
measurement screen. + the frequency to tune the receiver to.
10
Machine Translated by Google
You may use this feature to tune multi-band antennas. Use (up) and (down) cursor
keys to select a frequency to be set or changed. Press the key to switch between
SWR bars and numerical representation of this parameter:
Do not forget to press (ok) key to start or stop measurement. pressing the
the (help) key will show a list of other commands.
11
Machine Translated by Google
The Show all mode (the key) will show various parameters of a load on a single
screen. Particularly, SWR, return loss (RL), |Z| (magnitude of impedance) as well as its
active (R) and reactive (X) components are shown. Additionally, corresponding values of
inductance (L) or capacitance (C) are displayed.
This screen displays values for series as well as parallel models of impedance of a
load:
12
Machine Translated by Google
You may set the center frequency (the key) or scanning range (the key). By using
arrow keys ( ), these parameters may be increased or decreased.
Watch the triangle cursor below the graph.
Do not forget to press the (ok) key to start measurement or refresh the graph.
The key opens a list of amateur radio bands to set the required center frequency and
scanning range quickly. Also, you may use this function to set the whole frequency range
supported by the analyzer.
Press the key to access the list of additional commands for this mode.
13
Machine Translated by Google
In the R,X graph mode (press the key in the Main menu), values or R (active part of the
impedance) and X (reactive part) are plotted in different colors.
In these graphs, positive values of reactance (X) correspond to inductive load, while
negative values correspond to capacitive load. Please notice the difference in the plots
when series or parallel model of impedance is selected through the Settings menu:
14
Machine Translated by Google
The Smith/ polar chart (press the + key combination in the Main menu) is a good way
to display reflection coefficient over the specified frequency range:
Do not forget to press the (ok) key to start measurement or refresh the graph.
As usual, press the key for a help screen.
Please notice: Non-US version of analyzers will display Smith chart; a polar chart is
displayed instead on US version.
15
Machine Translated by Google
Press You. will be prompted to edit the selected memory slot name. Follow
instructions on the display. The new scan will be performed and the data will be saved in
the selected memory slot.
To retrieve your readings from the memory, press then key, select necessary
memory slot number and press .
To edit names of existing memory slots, press + and then select the slot number to edit:
16
Machine Translated by Google
4.5.6. calibration
Although RigExpert AA-600, AA-1000 and AA-1400 are designed for high
performance without any calibration, an open-short-load calibration may be applied for
better precision.
The standards used for calibration should be of high quality. This requirement is
especially important for high frequencies (100 MHz and above). Three different
calibration standards should be used: an “open”, a “short” and a “load” (usually, a 50-
ohm resistor). The place where these standards are connected during calibration is called
a reference plane. If the calibration is done at the far end of a transmission line,
parameters of this line will be subtracted from measurement results and the analyzer will
display “true” parameters of a load.
To perform calibration,
1. Enter the SWR graph (the key), the R,X graph (the key) or the Smith/ polar chart
(the + key combination) mode.
17
Machine Translated by Google
4. Connect an “open” to the analyzer and press the key. The analyzer will rescan the
specified frequency range and save calibration data to its memory.
6. Connect to “load” and press the key. Please notice that for displaying the SWR graph
and the Smith/ polar chart correctly, the System impedance parameter in the Settings
menu (see page 24) should be the same as the actual resistance of the “load”.
After the parameters of all three loads are measures, the “cal” indicator appears at the
bottom of the display:
18
Machine Translated by Google
Changing the center frequency or the sweep range will invalidate calibration.
Additionally, pressing the key in the Calibration screen will invalidate the
current calibration, and pressing the key will return the analyzer to the center
frequency and the sweep range used during the last calibration:
19
Machine Translated by Google
A short electrical pulse is felt over the line, and then a reflected pulse is observed. By
knowing the delay between two pulses, the speed of light and the cable velocity factor, the
DTF (distance-to-fault) is calculated. The amplitude and the shape of the reflected pulse
give the operator idea about the nature of the fault.
Impulse response:
Instead of a short pulse, a “step” function may be sent over the cable.
Step response:
20
Machine Translated by Google
(This method is often called a “Frequency Domain Reflectometry”, but the “TDR”
term is used in this document since all calculations are made internally and the user can
only see the final result.)
The vertical axis of the resulting graphs displays the reflection coefficient: ÿ=-1 for
short load, 0 for matched impedance load (ZLoad=Z0), or +1 for open load. By
knowing the cable velocity factor, the horizontal axis is shown in the units of length.
See the examples of typical Step Response graphs on the next page.
21
Machine Translated by Google
Machine Translated by Google
4.6.2. Practice
Press + to open Impulse Response (IR) and Step Response (SR) graphs:
The characteristic impedance and the velocity factor of the cable, as well as the display
units (meters or feet) may be changed in the Settings menu.
The (ok) key starts a new measurement, which will take about a minute. You may
disconnect your antenna or leave it connected to the far end of the cable. This will only
affect the part of the graph located behind the far end of the cable.
Use the arrow keys to move the cursor or to change the display range. Watch the
navigation bar at the top-right corner of the screen to see the current position of the
displayed part of the graph.
The key will start a new measurement, saving results in one of 10 memory slots.
The key will retrieve saved data. Use the + combination to edit memory names, if
needed.
Pressing + opens a data screen which displays numerical values of impulse and step
response coefficients, as well as Z (estimated impedance) at cursor.
23
Machine Translated by Google
The Settings menu (press the key in the Main menu) contains various settings for
the analyzer. The first page contains the following commands:
– language selection
– backlight brightness and timer
– color scheme selection
– sound on or off
– go to the second page which contains additional settings
– RF bridge test. Two filled bars display signal levels at the left and at the
right legs of the resistive bridge. With no load at the antenna connector, the
screen should look like shown on the picture:
For the 50-Ohm load, the filled bars should stand at corresponding positions (notice
the “no load” and “50 ÿ” marks):
25
Machine Translated by Google
If one of the bars of both bars is not filled at all, the RF output stage or/and the detector
circuits are not working properly in the analyzer:
On the above picture, the first bar indicates no RF signal at one of the legs of the
resistive bridge. Most likely, this means that a high power (such as, from a transmitter)
was injected into the antenna connector and the analyzer was damaged.
– output voltage detector vs. frequency graph. With no load at the antenna
connector, the display should look like shown on the pictures:
26
Machine Translated by Google
AA-600: AA-1000:
AA-1400:
The voltage curve should stay between horizontal lines. The vertical lines are the
bounds of analyzer's sub-bands.
27
Machine Translated by Google
The top of the curve should be located in the middle of the screen, between
two horizontal lines. A small horizontal shift of the curve is allowed.
A conventional USB cable may be used for this purpose. The supporting software is
located on the supplied CD or may be downloaded from the www.rigexpert.com
website. Please see the Software Manual for details.
28
Machine Translated by Google
5. Applications
5.1. antennas
The above picture shows SWR graph of a car VHF antenna. The operating frequency is
160 MHz. The SWR at this frequency is about 1.2, which is acceptable.
The next screen shot shows SWR graph of another car antenna:
The current resonant frequency is about 135 MHz, which is too far from the desired one.
The SWR at 160 MHz is 2.7, which is not acceptable in most cases.
29
Machine Translated by Google
Other types of antennas may contain more than one element to adjust (including coils,
filters, etc.), so this method will not work. Instead, you may use the SWR mode, the Show
all mode or the Smith/ polar chart mode to continuously see the results while adjusting
various parameters of the antenna.
For multi-band antennas, use the Multi SWR mode. You can easily see how changing
one of the adjustment elements (trimming capacitor, coil, or physical length of an aerial)
affects SWR at up to five different frequencies.
The above pictures show R and X graphs for a piece of cable with open- and short
circuited far end. A resonant frequency is a point at which X (reactance) equals to zero:
30
Machine Translated by Google
The velocity factor is a parameter which characterizes the slowdown of the speed of the
wave in the cable compared to vacuum. The speed of wave (or light) in vacuum is known
as the electromagnetic constant: c=299,792,458 meters per second or 983,571,056 feet
per second.
Each type of cable has different velocity factor: for instance, for RG-58 it is 0.66.
Notice that this parameter may vary depending on the manufacturing process and
materials the cable is made of.
2. Knowing the electromagnetic constant and the velocity factor of the particular type
of cable, find the speed of electromagnetic wave in this cable.
Example:
31
Machine Translated by Google
3. Calculate the physical length of the cable by dividing the above speed by the
resonant frequency (in Hz) and multiplying the result by the number which
corresponds to the location of this resonant frequency (1/4, 1/2, 3/4 , 1, 5/4, etc.)
Example:
Example:
2. Calculate the speed of electromagnetic wave in this cable. Divide the length by 1/4,
1/2, 3/4, etc. (depending on the location of the resonant frequency), then multiply by
the resonant frequency (in Hz).
Example:
3. Finally, find the velocity factor. Just divides the above speed by the
electromagnetic constant.
Example:
32
Machine Translated by Google
By using a TDR (Time Domain Reflectometer) mode, even minor discontinuities may
be located in the transmission line.
Example:
The TDR mode shows a visible peak at 1.04 meters, where two 50-Ohm cables
are joined. A peak at 6 meters indicates open-circuit at the end of the cable.
33
Machine Translated by Google
Pieces of cable of certain electrical lengths are often used as components of baluns
(balancing units), transmission line transformers or delay lines.
Example:
1/4- ÿ stub for 28.2 MHz, cable is RG-58 (velocity factor is 0.66)
2. Cut a piece of cable slightly longer than this value. Connect it to the analyzer.
The cable must be open-circuited at the far end for 1/4-ÿ, 3/4-ÿ, etc. stubs, and short-
circuited for 1/2-ÿ, ÿ, 3/2-ÿ, etc. ones.
Example:
A piece of 1.85 m (6.07 ft) was cut. The margin is 10 cm (0.33 ft). The cable
is open-circuited at the far end.
3. Switch the analyzer to the Show all measurement mode. Set the frequency the
stub is designed for.
Example:
4. Cut little pieces (1/10 to 1/5 of the margin) from the far end of the cable until the X value
falls to zero (or changes its sign). Do not forget to restore the open circuit, if needed.
Example:
34
Machine Translated by Google
1. Connect a non-inductive resistor to the far end of the cable. The exact value of
this resistor is not important. However, it is recommended to use 50 to 100 Ohm
resistors.
Example 1: 50-Ohm cable with 100 Ohm resistor at the far end.
Example 2: Unknown cable with 50 Ohm resistor at the far end.
2. Enter the R,X graph mode and make measurement in a reasonably large
frequency range (for instance, 0 to 50 MHz).
35
Machine Translated by Google
3. Changing the display range and performing additional scans, find a frequency
where R (resistance) reaches its maximum, and another frequency with
minimum. At these points, X (reactance) will cross the zero line.
Be sure to place the capacitor or the inductor as close as possible to the RF connector
of the analyzer.
36
Machine Translated by Google
1. Enter the R,X graph mode and select a reasonably large scanning range. perform
the scan.
Example 1: Example 2:
Unknown capacitor Unknown inductor
2. By using left and right arrow keys, scroll to the frequency where X is -25…-100
Ohm for capacitors or 25…100 Ohm for inductors. Change the scanning range
and perform additional scans, if needed.
3. Switch to the Data at cursor mode by pressing + and read the value of
capacitance or inductance.
Example 1: Example 2:
Unknown capacitor Unknown inductor
37
Machine Translated by Google
5.3.2. transformers
RigExpert analyzers can also be used for checking RF transformers. Connect a 50 Ohm
resistor to the secondary coil (for 1:1 transformers) and use SWR graph, R,X graph or
Smith/ polar chart modes to check the frequency response of the transformer. Similarly,
use resistors with other values for non-1:1 transformers.
5.3.3. traps
The trap is usually a resonant LC network used in multi-band antennas. By using
a simple one-turn wire coil a resonant frequency of a trap may be measured.
Example:
38
Machine Translated by Google
For frequencies up to 200 MHz, first harmonic of output signal can be used. Above 200
MHz, tune your receivers to odd higher harmonics.
Enter the SWR mode or the Show all mode, and press (ok) key to start the RF
the output.
If needed, use the frequency correction option in the Settings menu (see page 24).
6. Troubleshooting
Before asking for a tech support, please make sure to run RF bridge, detector and band
pass filter tests (see pages 25-27 for details). You may also visit our website,
www.rigexpert.com, select your analyzer model from the list and then click Troubleshooting.
39