Reinforced Masonry Under Compression Changes To As 3700 2018
Reinforced Masonry Under Compression Changes To As 3700 2018
Reinforced Masonry Under Compression Changes To As 3700 2018
‘MASONRY STRUCTURES’
REINFORCED MASONRY UNDER COMPRESSION
UPDATE
The Concrete Masonry Association of
Australia (CMAA) identified that due to some
impractical reinforcement detailing requirements
the current design method for compression in AS 3700
‘Masonry Structures’ (2011) for reinforced masonry (RM) walls
severely limits their design compressive capacity of RM walls.
Where:
Φ = Capacity reduction factor = 0.75 (Table 4.1 AS 3700 (2011)
for RM walls)
*See final page for a full list of all notation used
ç
ç
= ç
ç
compressive capacity
design compressive
loads
When applying each of these equations, there are
significant differences in capacity provided.
Minimum 2D,
where D is
the diameter
of the steel
reinforcing bar
These formulas are evidence based, self-consistent and easy to use. Designers can now design RM walls
under compression with ease, rationally allowing for slenderness and eccentricity without the stringent
control on the detailing of reinforcement and the strength of the grout, which unnecessarily
work to reduce the compressive capacity of reinforced concrete block walls.
The AS 3700 (2018) formula is shown to predict higher capacity than what is currently
represented in AS 3700 (2011) without any need for lateral reinforcement detailing. The
new equation will thus provide more competitive designs.
In conclusion, the experimental research has uncovered data and knowledge
hitherto not well understood and has provided a strong basis to develop a
more rational design formula for reinforced concrete masonry walls.
The below table shows a comparison of compressive capacities between codes. The wall height chosen
was 2.7m and the masonry block strength was 15MPa.
AS 3700
grout strength (2011) AS 3700 (2018)
Block Steel f’cg <1.3 f’uc
type/ wall thickness configuration
f’cg RM URM RM URM
(Mpa) eccentricity = 0
AS 3700
grout strength (2011) AS 3700 (2018)
Block Steel f’cg <1.3 f’uc
type/ wall thickness configuration
f’cg RM URM RM URM
(Mpa) eccentricity = 0
The Concrete Masonry Association of Australia (CMAA) is the peak body representing the concrete
masonry manufacturers of Australia, including bricks, blocks, pavers & retaining walls.
We support the concrete masonry industry by providing technical information and advice to architects,
engineers, specifiers and educators.
Telephone: +612 8448 5500 Suite 7.01, Level 7, 154 Pacific Highway
Technical Hotline: 1300 667 617 St Leonards NSW 2065 Australia
This information is intended for use by a structural engineer. While the contents of this information are believed to be accurate and complete, the information given is
intended for general guidance and does not replace the services of professional advisers on specific projects. Local or State regulations may require variation fromthe
practices and recommendations contained in this publication. CMAA disclaims any liability whatsoever regarding the contents of this publication.