You will always have sufficient power with a Fischer Panda generator
The water-cooled diesel generators from Fischer Panda are renowned Company Headquarters in
worldwide for being innovative, reliable and extremely quiet. The product Paderborn, Germany
range includes over two hundred different generators for performance
ranges up to 200 kW.
2
Fischer Panda super-silent
sound insulation system
Compact and lightweight design
• Quiet operation
• Less space required for installation
• Can be installed anywhere on-board
• Generator can be fitted in centre of gravity
• Hermetically sealed capsule
• All connections pre-fitted on capsule GRP Sound insulation capsule is standard for
generators up to 25 kW.
Panda marine generators up to 25 kW are delivered with a GRP sound
insulation capsule with “3D” sound insulation material as standard.
“3D” - up to 25 mm thick
“4DS” - up to 40 mm thick
“6DS” - up to 60 mm thick (only MPL)
Stainless-steel sound-insulation capsule “MPL”
for generators from 25 kW.
• Water-cooled windings
• Dual-circuit cooling
• No appreciable warming of engine room
Seawater with high salt content and tropical temperatures increase the
danger that metal can be affected by galvanic corrosion (Electrolysis).
Even a very small current can have a destructive effect. To prevent this,
Fischer Panda uses dual-circuit cooling for generator and engine on all
Panda generators from 3.2 kW upwards. The engine and generator are
cooled by freshwater. Seawater only comes into contact with the heat
exchanger, which is manufactured from a high quality alloy (CuNi10Fe).
3
High performance AC windings from Fischer Panda
Single-phase windings
Single-phase Three-phase
The 230 V 50 Hz, (120/240 V 60 Hz) single phase windings are standard
for generators up to 25 kW. A three-phase version should be considered
above 12 kW, as the Panda generator permits asymmetrical loads up to
50 % per phase. A Hybrid Power System should also be taken into con-
sideration for small to middle range on-board power systems.
lighting boilers compressors ovens
Three-phase windings
The 400 V AC 50 Hz, (208 V 60 Hz) three-phase winding has the highest
level of efficiency and the best qualities. This winding can also supply
single-phase AC with the appropriate phase distribution. A three-phase All the benefits of the asynchronous generator:
generator should always be chosen above 25 kW (from Panda 30).
• Overload protection
• Water-cooled
• Short-circuit stability
Fischer Panda generators have used their own electronic Voltage Control
System (VCS) for controlling generator and engine. The engine speed The outstanding sine wave of the Fischer
is progressively controlled. This ensures that the output voltage of the Panda generator
asynchronous generator has a tolerance of ± 3V.
4
“Perfect Power” iSeries generators
The Panda iSeries generators have been especially designed to be
compact, quiet and powerful with up to 30 % weight and space savings!
They are ideal for superyacht owners looking for a night generator with low
operating sound levels and vibrations. The generators are characterised by
their modern, innovative and environmentally friendly inverter technology.
iSeries generators using parallel inverters can be connected in parallel
without any additional cables and synchronised.
The speed of the diesel engine is adjusted according to the user’s changing
power requirements while the output voltage always remains constant
from the inverter. Variable speed control considerably reduces exhaust • Highly efficient - maximum energy
emissions and fuel consumption in comparison with a traditional generator • Variable speed - load-dependent
with a fixed speed. The maximum speed of the engine is 2800 RPM. The • Meets latest emission standards
electric load is provided with a constant output voltage of 230 V / 50 Hz or
• Modular design ensures installation flexibility
400 V / 50 Hz via an inverter.
• Extremely stable voltage and frequency
• Optional CAN SAE J1939 Interface
230 V
5
Fischer Panda generators - easy to use and operate
Fischer Panda panels allow the generator to be operated from another
location onboard. Important operating information is displayed. Options
are available for connecting panels in parallel or with a slave panel. The
generator can then be operated from multiple locations for even more
flexibility. A panel can be installed in the cabin and another panel can be
installed on the flybridge or in the engine room.
Panel P4 Control for iControl panel for Digital panel for “Compact Power”
Panda 4000s.Neo PMS generator “Perfect Power” iSeries Generators xSeries AC generators and
“Hybrid Power” DC generators
6
Innovative Generator Control
Innovative, flexible and reliable – these are the attributes of the new generator
control from Fischer Panda for “Perfect Power” iSeries generators and
“Compact Power” xSeries generators up to 30 kW.
In the age of modern data communications and energy systems, it is more
and more important that the generator is able to integrate with an existing
control and regulation system. Fischer Panda offers an extremely powerful
and user-friendly generator control system:
Controller
Bus Communication
Sensors / actuators
Connection box
Bus communication
v
230V AC
The Fischer Panda FP Bus provides 100 % SAE J1939 functionality. This SAEJ1939 CANBus Module
allows the generator to be integrated into a higher-level control system.
A remote start and stop of the generator is possible. All electrical data
can be accessed via the bus: voltage, current, frequency and power.
Information such as cooling, exhaust and oil temperatures etc. can be
monitored.
7
Fischer Panda “Perfect Power” iSeries
generators with variable speed
Generators with variable speed for reduced fuel consumption,
quiet operation and less exhaust emissions.
Up to 50 % less weight and 30 % space savings when compared
to asynchronous generators of the same class
• 50 Hz - 230V
• 50 Hz - 400V
• 60 Hz - 120V
• 60 Hz - 230 V
• 60 Hz - 2 x 120 V / 240 V
variable speed - load dependent
400V kW
3-phase 50 Hz kVA
8
up to
20 %
fuel
savings
54 / 64 / 68 54 / 64 / 68 54 / 64 / 68 55 / 60 / 70 55 / 60 / 70 54 / 59 / 69 55 / 60 / 70
1-phase 50 Hz
kVA 4.0 8.0 9.4
kW 6.8 8.0
400V
3-phase 50 Hz
kVA 8.0 9.4
Voltage tolerance ±5 % ±5 % ±3 V ±3 V ±3 V ±3 V
Cooling circuits 2 2 2 2 2 2
Sound insulation 3D 3D 3D 3D 3D 3D
Number of cylinders 1 2 2 2 2 2
The data in this publication reflects the technical state at time of print. Due to our policy of continual product development, we reserve the right to alter technical specifications
without notice. Dimensions apply for the sound insulation capsule only and do not include latches, fittings etc. Additional room will need to be calculated for the installation
to include hoses, cables and capsule mountings. Please confirm current dimensions and weights when ordering.
10
Panda Panda Panda Panda Panda Panda Panda
12000x 12 Mini 15000x 18x 24x 30x 30ICx
PMS PMS PMS PMS PMS PMS PMS
11.5
11.5
±3 V ±3 V ±3 V ±3 V ±3 V ±3 V ±3 V
2 2 2 2 2 2 2
3D 3D 3D 3D 3D 3D 3D
3 3 3 3 4 4 4
53 / 63 / 67 54 / 64 / 68 54 / 64 / 68 55 / 65 / 69 55 / 65 / 69 55 / 65 / 69 55 / 65 / 69
NOTE: *) For asynchronous generators up to and including P15000: the KVA is calculated with cosPhi = 0.85 for a short starting performance of inductive consumers.
Otherwise it should be calculated with a factor of 1. Generators above and including Panda 16 with an optional start performance with compensation or starting-current
booster are calculated with cosPhi = 0.85 otherwise it should be calculated with a factor of 1.
11
Fischer Panda “Hybrid Power” DC generators
The ideal battery-charging generators for battery systems which may be required to
power larger consumers for short periods during the day.
Nominal voltage V 12 24 24 24
Cooling circuits 2 2 2 2
Capsule type 3D 3D 3D 3D
Cylinders 1 1 2 3
The data in this publication reflects the technical state at time of print. Due to our policy of continual product development, we reserve the right to alter technical specifications
without notice.
Dimensions apply for the sound insulation capsule only and do not include latches, fittings etc. Additional room will need to be calculated for the installation to include
hoses, cables and capsule mountings.
12
Battery bank
Inverter
2 2 2 2 2 2
3D 3D 3D 3D 3D 4DS
3 3 3 3 4 4
53 / 63 / 67 54 / 64 / 68 55 / 65 / 69 55 / 65 / 69 55 / 65 / 69 55 / 65 / 69
The performance of an AGT-DC generator must be limited to the constant performance when batteries are used.
1)
13
Fischer Panda “Hybrid Power” DC generators
with variable speed
The Fischer Panda variable-speed Hybrid DC generators have An autostart function prevents the batteries from being drained.
been especially designed for electric propulsion on board. These A CAN bus connection transfers and receives information from a
generators are compact, quiet, powerful and economical. They are ship’s control system.
characterized by their modern , innovative and electronic regulated
The new Fischer Panda “super silent” variable-speed Hybrid DC
hybrid charger which allows a wide RPM range at constant volt-
generator provides you the comfort for nearly endless electrical
age. This technology is a further step into green motion of electric
cruising (if required).
propulsion.
Variable-speed Hybrid DC generators feature:
Opposite to the conventional ship’s engine where the propeller
is attached mechanically, the independency between RPM and • Small size and low weight- compact installation
output power of the variable-speed Hybrid DC generator enables • Highly efficient – maximum energy
the engine to run on the required propeller power. This allows • Variable speed – load–dependent
significant fuel savings especially at both low and medium loads. • Easy to install – no forced-air circulation required in
machine room
The variable-speed Hybrid DC generator is available in various
• Environmentally friendly – low fuel consumption
output voltages up to a current of 300 A and an output power of
• Digital display – up to date all the time
up to 100 kW
Electric cruising with battery only Hybrid cruising with battery and Silent onboard power with battery
generator only for your appliances
Hybrid onboard power with battery and Battery charging with generator Emergency mode - generator
generator ( high power demand ) cruising without batteries
Battery bank
Electrical distribution
Sound level 1)
(7m / 3m 1m) [dB] 55 / 60 / 70 54 / 59 / 69 55 / 60 / 70
Performance
Control
Autostart integrated
15
Parallel power
from Fischer Panda
generators
“Plug and play” load switching using xControl xControl Panel xControl Panel
16
e r fect
P
for lls
u
u ltih
m
PMGi Parallel
Inverter Air conditioning Compressors Appliances
17
Fischer Panda also
offers an extended
Generator-Guarantee for
North America and
South America
Further information:
www.fischerpanda.de
*) Please consult the Fischer Panda Warranty Plus for the exact requirements and conditions for Extended
Warranty, Guarantee and Warranty packs. Furthermore, the general Guarantee Conditions for mobile and
stationary Fischer Panda generators apply.
**) The above listed guarantee / warranty packages are only available for Fischer Panda marine und
commercial vehicle generators.
1) Whichever comes first.
18
Installation and custom services by Fischer Panda
Installation kits
Fischer Panda supplies installation kits with all the necessary
cables, hoses, connection pieces and accessories to ensure that
the system can be correctly installed in a yacht’s engine room,
catamaran’s hull or inside a vehicle. This even includes specific
hose and cable lengths.