RECLOSER-FARADAY-33KV Auto Recloser Brochure
RECLOSER-FARADAY-33KV Auto Recloser Brochure
RECLOSER-FARADAY-33KV Auto Recloser Brochure
Product brochure
2012/9
Zhejiang Farady Powertech Co., Ltd.
++++Service environment
a) Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
++++Offering
With optional classes for rated current range:
Rating voltage available from 15kV-38kV
Rating current available from 200A to 1600A
Breaking capacity from 12.5kA-31.5kA
With optional classes for installation styles:
Three phase, vacuum recloser.
With optional relay protection curves for user choice:
Instantaneous over-current protection.
Timing over-current protection.
Negative sequence over-current protection.
Directional over-current protection(*).
Over-voltage protection.
Under voltage protection.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice:
RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*).
Modbus communication protocol is optional(*).
IEC 60870-5-101 communication protocol support.
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese languege (*).
With optional measurement functions for user:
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage.
Frenquency, power(kWh), reactive power(kVarh),power factor .
With optional reclosing interval for user pre-program:
Reclosing times setting support.
Dead time setting support.
With events recording function:
SOE 64 operations record.
Fault record and normal operation record.
Note: (*) mean should customized by manufacturer if needed.
++++Recloser feature
Outline of recloser:
++++Technical data
No. Item Unit data
1 Rated voltage kV 38
2 Rated current A 630/800
3 Rated frequency HZ 50/60
4 Power frequency 1min Dry kV 85
Wet 75
5 Lightning impulse withstand voltage(peak value)alternate, kV 170
opposite/fracture
6 Rated short circuit breaking current kA 16/20
7 Rated short current switching current(peak value) kA 40/50
8 Rated peak value withstand current kA 40/50
9 4S short time withstand current kA 40/50
10 Rated operating circulate O-T1-CO-T2-CO-T3-CO-T4-CO-Block(or step
up by controller)
Control
• 4 contacts output, 2 high-speed outputs
- Open(Trip), Close, Spares
- Configurable : Name, Pulse width
• Switch Control
- Operator place : Remote, Local
(Front Panel/PC Tool)
- Interlocks : Control Lock, Gas low,
Mechanical Lock, Current Switch status
- Close interlock conditions (Selective) :
Live load, Phase sync. fail
• SBO (Select before Operate)
- Secure switch operation
- SBO timeout (settable)
• Auto reclosing
- Recloser On/Off
- Protection On/Off
- Ground protection On/Off
• Battery Test, Reset Indicators
Protection
• Fault passage indicator
• 3-stage over current protection (directional or non-directional)
- Fast and delayed TC trip elements for phase and earth fault
- 54 types of built-in TC Curves (IEC, ANSI, Recloser curves)
and 4 Customized TC Curves
- Definite time over-current element
- Definite time HCT (High Current Trip)
• Negative sequence over-current protection
• SEF(Sensitive earth fault) detection
• Cold load protection(pickup adjustment)
• Magnetizing inrush restraints
• Sequence coordination
• Open line detection
• Phase sync. fail detection
• Over voltage, under voltage, under /over frequency
• Auto reclosing (up to 4 shots)
• Auto sectionalizing
• 4 setting groups, automatic setting group change
depending on power flow
Power quality monitoring
• Sag, Swell, Interruption Detection
- Status
- Events : Time-stamp, Magnitude, Duration
- Counters : Statistics for each phase, duration classified by IEEE 1159.
- Accumulated interruption time
- Waveform recording on events
• Harmonics
- THD (Total harmonic distortion)
- Each components up to 31th harmonics
- Events by threshold setting, Counter
Event/Fault Recording
• SOEs are stored on non-volatile memory with 1ms time-stamp
• Event history buffers are categorized by group
- I/O Events, Function Events, System Events
- Fault current Events
- PQM Events
- Demand I,P,Q
- Daily Max. I,P,Q
- Counter : Switch open, Fault, Restart
- Memory size : 1Mbytes
• Fault waveform recording
- 8 faults, 6 PQM waveforms can be stored on non-volatile memory
- 1 Manual triggered waveform
- 128 sample/cycle, 20 cycles
- Waveforms are stored as COMTRADE file format through PC maintenance software
- Memory size : 2 Mbytes
Communication
• Supports DNP3.0 Subset level 3, DNP over TCP/IP
• IEC60870-5-101, 104
• Index mapping & class assignment
• Modem control
• Unsolicited Dial-Up
• Built-in protocol monitor
Auxiliary functions
• Self-diagnosis
• CAN interface with controller
• PC software for setting & maintenance
• Waveform evaluation software
• Firmware upgradable at site
++++Controller structure
Figure 40 VOLTLOGIC-351 cartoon size
++++detail controller feature refer to Voltlogic series ACR controller user manual