Champ FMVA LED Cl. I, Div.

2, Groups A, B, C, D
Cl. I, Zone 2
UL Listed
IECEx/ATEX
6L
floodlights Cl. II, Groups E, F, G Type 4X; IP66

The Champ FMVA LED family


Champ® FMVA LED floodlights are designed to provide full-spectrum, crisp, white light.
Seven versions of the FMVA LED are available, from 3,000 to 15,000 lumens, providing ideal
solutions for a wide range of harsh and hazardous applications.
Nominal Lumens Equivalent HID
Model lumensA Watts per watt luminaire Energy savings
FMVA3L 3,312 26 129 70W
FMVA5L 5,381 45 133 100W Up to 75% reduction in
FMVA7L 7,274 58 132 175W energy costs and 150,000
FMVA9L 9,479 69 142 250W
hours of continuous
FMVA11L 11,776 84 144 320W
FMVA13L 13,362 95 143 400W operation
FMVA15L 15,183 113 140 500W
Standard materials:
Applications: Certifications and •  Lamp housing and adapter – die cast
•  Oil and gas refineries, drilling rigs, compliances: aluminum with Corro-free epoxy powder
petrochemical facilities, food and beverage coat
• DesignLights Consortium® Qualified
facilities, platforms, loading docks, • Lens – heat- and impact-resistant glass
(pending)B
tunnels, outdoor wall and stanchion (standard)
mounted general area lighting, and where NEC/CEC:
• Gaskets – silicone and neoprene
flammable vapors, gases, ignitable dusts, • Class I, Division 2, Groups A, B, C, D;
fibers or flyings are present Class I, Zone 2; Class II, Groups E, F, G • External hardware – stainless steel
• Locations requiring continuous and • Wet locations, Type 4X, IP66
consistent light levels in extreme ambient
UL standards: Fixture life:
temperatures
• UL844; UL1598; UL1598A; UL8750 •  Rated life of 60,000 hours at 55°C
• Where extremely corrosive, wet, dusty, operating ambient and 24/7 continuous
hot and/or cold conditions exist IEC standardsF:
operation for 365 days
• IP66, Type 4X, marine, wet locations and • IEC 60079-0, 6th Edition (2011-06) + Corr.
1 (2012-01) + Corr. 2 (2013-12) + I-SH 01 • Economic life of 150,000 hours at 25°C
hose down environments ambient
(2013-11) + I-SH 02 (2014-10)/EN 60079-
• Classified and hazardous locations
0:2012 + A11:2013

6L
• IEC 60079-7, Edition 5.1 (2017-08)/EN LED system:
Features: 60079-7: 2015 +A1:2018
•  Cool white (5000K, 70 CRI) and warm
•  Instant illumination and restrike • IEC 60079-31, 2nd Edition (2013-11)/EN white (3000K, 80 CRI)
• Better visibility with crisp, white light 60079-31:2014
• Custom designed optics – 7x6 standard;
• Cold temperature operation/no warm-up • IEC 60598-1:2008/EN60598-1:2008 3x3 (optional)
required • IEC 60598-2:2008/EN60598-2:2008
• Minimum T3C temperature rating –
safely operate in the most hazardous
IECEx/ATEXF: Photometrics:
• 0359 •  Refer to www.eaton.com (under the
environments and any non-hazardous
location • IECEx UL15.0029X Resources tab of each product family) for
• DEMKO 15 ATEX 1377X specific photometric IES files
• Serviceable drivers
• Easy installation – yoke design to mount • DEMKO 15 ATEX 1383
to SFA6 • Ex II 3 G Ex ec mb IIC T5 Gc Tamb -40° - Electrical ratings:
• Energy-efficient technology – up to 72% +55°C
Input power Input amps at
energy savings over HID fixtures • Ex II 3 G Ex ec mb IIC T5 Gc Tamb -40° - Model (watts) 120-277 VAC
• 60,000 hours of rated life at 55°C – +40°CE
FMVA3L 26 0.27 - 0.10
eliminates need for frequent lamp • Ex ec IIC T5 Gc Tamb -40°C - +40°C FMVA5L 40-41 0.41 - 0.16
replacement • Ex ec IIC T4 Gc Tamb -40°C - +55°C FMVA7L 54-56 0.56 - 0.21
• Contains no mercury or other hazardous FMVA9L 67-69 0.78 - 0.28
• Ex II 2 D Ex tb IIIC T65 Db Tamb -40°C -
substances FMVA11L 81-84 0.84 - 0.30
+40°C FMVA13L 91-95 0.95 - 0.34
• Shock- and vibration-resistant solid state • Ex II 2 D Ex tb IIIC T80 Db Tamb -40°C - FMVA15L 107-113 1.12 - 0.40
luminaires have no filaments or glass +55°C
components that could break – greatly
reduces the risk of premature failure • Ex tb IIIC T65 Db Tamb -40°C - +40°C FMVA3L-FMVA15L

• Operating ambient: -40°C to 65°C (NEC • Ex tb IIIC T80 Db Tamb -40°C - +55°C Voltage range, VACC 100-277V at 50/60 Hz
only; IEC: -40°C to 55°C) Voltage range, VDC 127-250V
Power factor >0.90D
• 5 year fixture warranty
ATolerance +/- 10%; at 120 VAC, 25°C ambient, 7x6 optics.
BRefer to www.designlights.org Qualified Products List under family models for full listing details. Not all models are approved for all application categories.
CIEC voltage; 100-250 VAC at 50/60 Hz, UNV34 option for FMVA9L-15L only.
DFor FMVA3L: PF >0.90 from 100-255 VAC. From 255-277V, it varies +/- 10%. All other lumen levels are above 0.90 PF across full voltage range.
ET4 from -40°C to +40°C when used with 3x3 optic.
FNot applicable for FMVA9L-15L UNV34.

www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 333


Champ FMVA LED Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
UL Listed
IECEx/ATEX
6L
floodlights Cl. II, Groups E, F, G Type 4X; IP66

Versatile design
• Can be used for outdoor
or indoor applications, High lumen output
and for a wide range • Up to 144 lumens per watt
of mounting heights • Up to 72% energy savings
depending on model and over traditional HID fixtures
light level requirement (compared to 400W MH)

Smaller and lighter


• 25% smaller footprint than
previous model
• 10 lbs. (4.5 kg) less weight
than previous model

Full-frame yoke
• Designed to utilize the
SFA6 slipfitter and SWB6
wall mount bracket,
making it ideal for retrofit
or new installations

Multiple lens options


• Tempered clear glass lens
standard
Polycarbonate and diffused
6L


glass lens options available

Rugged heat sink


• Heat sink designed to perform and provide maximum light
levels in high ambient temperatures up to +65°C and as
low as -40°C
• Thick walled castings make for a tough, rugged housing
that keeps the internal driver and LED temperature down

334 www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton


Champ FMVA LED Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
UL Listed
IECEx/ATEX
6L
floodlights Cl. II, Groups E, F, G Type 4X; IP66

Ordering information:

Part number example


FMVA7LCY-UNV1-76-M20-S891-BZ

FMVA 7L C Y - UNV1 - 76 - M20 - S891 - BZ


Light source / intensity Voltage Paint

3L 3,312 nominal lumensG 100-277 VAC, 50/60 Hz; BLANK Gray


/UNV1H
127-250 VDC
5L 5,381 nominal lumensG BZ Bronze
/UNV34I 347-480 VAC, 50/60 Hz
7L 7,274 nominal lumensG WH White
9L 9,479 nominal lumensG
Optical distribution
Lens material
11L 11,776 nominal lumensG 7x6 floodlight pattern
76
13L 13,362 nominal lumensG optics BLANK Clear glass lens
3x3 floodlight pattern S891 Diffused glass lens
15L 15,183 nominal lumensG 33
optics
S903 Polycarbonate lens

Color temperature
Entries
C 5000K, 70 CRI (cool white) BLANK /4” NPT
3

W 3000K, 80 CRI (warm white) M20 20mm

6L
M25 25mm
Mounting

Y Yoke

Options: Accessories (ordered separately):


Description Suffix Description Cat. #
• Diffused glass lens..................................................................... S891 • Bull horn, gray..........................................................................BLHN
• Polycarbonate lens..................................................................... S903 • Bull horn, bronze................................................................ BLHN-BZ
• Bull horn, white................................................................ BLHN-WH
• Bolt-on visor.............................................................................. DSV2
• Bolt-on wire guard....................................................................... P62
• 316 stainless steel safety cable..............................................SC831
Can be added in the field
• Floodlight slipfitter.....................................................................SFA6
• Slipfitter wall mount adapter................................................... SWB6

Replacement driver kits (ordered separately)

FMVA 3-5-7L UNV1 DRIVER KIT


UNV1 replacement driver kit for 3L, 5L and
7L models
FMVA 9-11-13L UNV1 DRIVER KIT
UNV1 replacement driver kit for 9L, 11L and
13L models
FMVA 15L UNV1 DRIVER KIT UNV1 replacement driver kit for 15L model

FMVA 9L-11L UNV34 DRIVER KIT


UNV34 replacement driver kit for 9L and
11L models
FMVA 13L-15L UNV34 DRIVER KIT
UNV34 replacement driver kit for 13L and
15L models
G7x6 model.
HIEC voltage; 100-250V at 50/60 Hz.
IAvailable for FMVA9L-15L only.

www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 335


Champ FMVA LED Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
UL Listed
IECEx/ATEX
6L
floodlights Cl. II, Groups E, F, G Type 4X; IP66

Temperature performance data: Drivers:


Simultaneous Option FMVA3L-FMVA15L
rating
Minimum NEC: 100-277 VAC, 50/60 Hz; 127-250 VDC;
/UNV1
Ambient Class I, Class II, Class I, Class I, ATEX ATEX wire IEC: 100-240 VAC, 50/60 Hz; 127-250 VDC
Model temp. °C Div. 2 Div. 1 Div. 2; Div. 1 Zone 2 3G 2D temp. °C
40 T5 T4 T4 T5 T5J T65 105 /UNV34K NEC/CEC only: 347-480 VAC, 50/60 Hz
FMVA3L-
55 T4A T3C T3C T4 T4 T80 105
FMVA15L
65 T4A T3C T3C T4 – – 105

Weights and dimensions:


Width Height Depth
Model Lbs. Kg. in. mm. in. mm. in. mm.
FMVA3L-FMVA15L 32.00 14.50 15.50 393.70 12.00 304.80 7.00 177.80
6L

JT4 when using the 3x3 floodlight pattern optic.


KUNV34 driver available for FMVA9L-15L only.

336 www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton