Inteliscada 2.3.0 New Features List

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

InteliSCADA

Monitoring tool
for ComAp devices

SW version 2.3.0
1 General information 2
2 Changes in the version 2.3.0 3
3 Changes in the version 2.2.0 5
4 Changes in the version 2.1.2 7
5 Changes in the version 2.1.1 8
6 Changes in the version 2.1.0 9
7 Changes in the version 2.0.0 11
8 Notes 12

Copyright © 2022 ComAp a.s.


Written by ComAp
Prague, Czech Republic
ComAp a.s., U Uranie 1612/14a,
170 00 Prague 7, Czech Republic
Tel: +420 246 012 111
E-mail: info@comap-control.com, www.comap-control.com New features list
1 General information
This version contains support of a new product.

1.1 Clarification of Notation


Note: This type of paragraph calls the reader’s attention to a notice or related theme.

IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or improper function of the equipment if not performed correctly and may not be clear at
first sight.

WARNING: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or improper function of the equipment if not performed correctly and may not be clear at
first sight.

Example: This type of paragraph contains information that is used to illustrate how a specific function
works.

InteliSCADA 2.3.0 New features list 2


2 Changes in the version 2.3.0
2.1 New features
Licenses
2 new Display license types
Display Pro (2 devices, 64 trends sources, 10 trends/screen, InteliGateway, synchroscope)

Display Pro+ (4 devices, 128 trends sources, 10 trends/screen, InteliGateway, synchroscope)

Note: Added in license overview, license check, limitation and activation

Display license changed from "Display" to "Display Lite"


Trend sources limits changed
Pro: increased from 32 to 128

Pro+: increased from 32 to 256


Runtime and Preview
Login to devices in Runtime, new dialog for logging in as another user and back as a default user

Note: Autologout - when a non-default user is inactive for 10 minutes, the default user is logged in
again instead

Toolbar - responsive (button description disappears on small screens to reduce space)


Instruments
Synchroscope - available only for InteliSCADA Display license types
Instrument visibility based on a bit for each instrument
Text instrument - padding property
Trend instruments - the default left margin was increased
Instrument - context menu is available
BESS and PV instruments - ready for upcoming controllers
Editor
Toolbar - buttons reduction (Edit group, Zoom group)
Canvas - context menu is available
Grid - custom density
Image Gallery
Delete image

Images added (Marine, flow arrows)


Support of new devices and applications
InteliGen 500 G2 - SPtM, MINT applications
Others
Device language selection - if a device does not know the selected language, the default one is used.
The menu contains all languages available on devices of the given site.
Forgotten password reset - connection details of all devices will be removed, screens will be kept

InteliSCADA 2.3.0 New features list 3


Zoom
in canvas using mouse wheel + Ctrl key

key shortcuts (Ctrl + 0 for 100%, Ctrl + 1 for Fit to Screen)


"Hidden Screen" property - defines if the screen is available in the Screens overview in Runtime
Login to devices using UID and pin, for devices that support it (e.g. InteliGen 1000)
Fullscreen – Accessible from the settings menu or by pressing the F11 shortcut
Runtime and Designer icons – different colors for easier identification

Note: If the application icons were pinned (e.g. on the Windows taskbar), they need to be
unpinned and re-pinned to display the new icons correctly

Technical Changes
Install package
Backup of sites from MongoDB

Uninstallation option removes all InteliSCADA data newly from MongoDB, optional backup of sites
and logs
Note: When updating from InteliSCADA 2.2.0.50 to 2.3.0, there is no need to check the installation
of the MongoDB Community Server 5.0.8.0 component (if it has not been uninstalled)

Data reading optimization for Display licenses


Advanced Trend - optimization
InteliSCADA service and MongoDB service recovery settings
Export all - MongoDB logs were included
About window - OS Image Version was added for Display Licenses

2.2 Repairs
Data Row - it is possible to edit a setpoint even if the Editable checkbox was unchecked
Busbar/Line - Shift + resize sometimes does not work
If there are any not configured BINs on BIN input/output, the configured ones don’t display values, but
general errors
Paste
if no instrument is selected, 3 dots get stuck on the Paste icon
instrument pasted from another site redirects to the original link
it seems to not work when the clipboard does not contain an instrument definition - a message is
displayed now
Logo
Wrong logo in the upper left corner
Missing icon for InteliSCADA in 'Programs and features'
After restarting the InteliSCADA service (in special cases), the loading of the screen does not finish
correctly

InteliSCADA 2.3.0 New features list 4


3 Changes in the version 2.2.0
3.1 New features
Install package
License agreement update
MongoDB installation
Data migration from LiteDB to MongoDB
Backup of sites from MongoDB
Licenses
InteliSCADA Display license support – new type of license for InteliVision 10Touch
Activation

Limitation (1 device, 150 data points/screen, 10 000 data points/site, 16 trends sources)

License Details overview

Data points/screen indication in Editor


License Check site attribute and over limit indications in Designer
InteliSCADA Display – available only in InteliSCADA Display Runtime for InteliVision 10Touch
Opening the 1st site (or site list) after restarting the display
Devices tab in Runtime
Faster refresh data period
Sign out and Switch user menu items in Runtime (for system users)
Runtime and Preview
List of screens in the Runtime toolbar
Import site in Runtime
Change password in Runtime
Designer
Trends Sources panel to define the storage of data point values
new Advanced Trend instrument - linked to a Trend Source, which ensures data persistence
Text, Markdown Text instruments – Hide Scrollbars property
Scale property design change
Support of new devices and applications
InteliGen 1000
SPtM, MINT applications
InteliMains 1010
MCB, MGCB, BTB applications
InteliATS 50, InteliATS 70
 Mains-to-Mains, Mains-to-Generator applications
InteliGen4 200
SPtM, MINT applications

InteliSCADA 2.3.0 New features list 5


InteliGateways 100, 101, 300, 301
Others
Sites ordering
Remember password option in the Unlock dialog
Action Confirmation site attribute and popup dialog
About window – new information (Application, Database, Data version), License info only for Runtime
Technical changes
LiteDB replaced by MongoDB
refactoring, version check, DB issues notification, etc.
Devices of the archive type are not encrypted

3.2 Repairs
Control Button - missing commands User button 1-5 for Inteli Lite 4 and InteliGen4 200
Link in the manual opened in InteliSCADA – not possible to go back to InteliSCADA
Device with invalid login data - error in disconnected status indication
Lost connection to the InteliSCADA server when refreshing a page or switching tabs in browser
Massive outage for 32 devices causes some devices not to connect again
Export history fails in some cases (null value or object reference is not set)
Multihistory consumes excessive amount of RAM if multiple controllers repeatedly reconnect
Incorrect Timer value format

InteliSCADA 2.3.0 New features list 6


4 Changes in the version 2.1.2
4.1 New features
Support of InteliSys NTC BaseBox – Combi application

InteliSCADA 2.3.0 New features list 7


5 Changes in the version 2.1.1
5.1 New features
Single bit data point support for InteliFieldbus Gateway and InteliGateway

5.2 Repairs
InteliFieldbus Gateway and InteliGateway connection issue if any alarm list values are configured in the
communication module.
Editable Data Row – incorrect indication when access rights are insufficient.
User relogging sometimes doesn’t work correctly when switching sites using the same device(s) with
different access levels.

InteliSCADA 2.3.0 New features list 8


6 Changes in the version 2.1.0
6.1 New features
Editor
Grid on/off + density selection
Snap to grid
Screen Background Color property
Background and Border Color properties for Alarmlist, Multi Alarm List
Text Color property for Data Row, Bar Graph, Analog Meter, Trend, Alarm List, Multi Alarm List
Device bulk change
Now, the Device property is available when multiple instruments are selected, even if an instrument
without the Device property (e.g. Text) is included. Using Ctrl + A or selecting the mouse area is
thus more beneficial.
Number of selected instruments is displayed.
Runtime and Preview
Setpoints window
Support of new devices and applications
InteliFieldbus Gateway – available for the Pro and Pro+ license types
InteliGateway – available for the Pro and Pro+ license types
IGS-NT – PSC application
Technical changes
Backups
Recommendation of regular backup of all sites

Site backup when closing it in Designer

Logs backup during installation


Performance optimization (e.g. History loading)
Low disk space notification
Imported site size limited to 100 MB
Custom image size reduced to 3 MB

6.2 Repairs
Data Points Import – History Loading Failed issue for some controller types (IGS-NT family)
Export History
Last line cut
Not complete when history cache is still being processed
Data points of LED type are not available for default archives of some controller types (IL3 family)
Control Button instrument – order of available commands in the list after site import
Incorrect Data Row label in the Editor when Editable checked

InteliSCADA 2.3.0 New features list 9


2 modal dialogs – the bottom one is not visually suppressed
Values window – optimization of requests
Connection issues
After multiple attempts with wrong connection details
Lost connection to the InteliSCADA server in a specific case

InteliSCADA 2.3.0 New features list 10


7 Changes in the version 2.0.0
7.1 New features
Editor
New "Text" instrument with format properties (Font Size, Text Color, Text Alignment, Font Style)
Original "Text" instrument was renamed to "Markdown Text"
Data Row instrument – new properties Font Size, Unit Space
Breaker instrument – new properties Active State Color, Inactive State Color. Updated indication of
Synchronizing and Init state
Busbar and Junction instruments – possibility to control by a LED or a binary data point. For the binary
data point option there are new properties available – Invert value, Active/Inactive State Color
IMPORTANT: Important: Reimport of data points is needed if you want to add/edit a Busbar
or a Wire Junction in a site created in the previous version of InteliSCADA.

Trend instrument – new properties Header, Header Background Color, Border Color, Background
Color, Legend, Left Margin, Bottom Margin, Font Size. Other small changes to save space (e.g. 1 line
legend).
Background and Border Color properties for more instruments (Analog Meter, Bar Graph, IFrame,
Image)
Font Size property for Mode Selector and Control Button
Instruments panel – sorted alphabetically
Image Gallery – images added (e.g. vertical variants), tags updated
Data Point Selection – "Invisible" groups included
The smallest allowed size of some instruments was decreased
Support of new controllers and applications
InteliSys NTC BaseBox GeCon Marine – SPTM, MINT, SPI
InteliSys NTC BaseBox GeCon LandBased – SPTM, MINT, SPI
InteliGen NTC/NT BaseBox GeCon Marine – SPTM, MINT, SPI
InteliGen NTC/NT BaseBox GeCon LandBased – SPTM, MINT, SPI
Technical improvements
Performance optimization – data refresh period, history loading and scrolling, Analog Meter rendering,
RAM, Multi Alarm List, Editor/Preview switching,
Licenses – new HW ID format
More info in the log files – HW info, application version

7.2 Repairs
Force Values indication
ECU Alarm List sums in Preview
Mode Selector, Control Button: font size in Editor vs. Preview

InteliSCADA 2.3.0 New features list 11


8 Notes
8.1 Document history
Revision number Related sw version Date Author
6 2.3.0 9.12.2022 Dana Salingerová
5 2.2.0 13.7.2022 Dana Salingerová
4 2.1.2 28.2.2022 Dana Salingerová
3 2.1.1 13.12.2021 Dana Salingerová
2 2.1.0 10.11.2021 Dana Salingerová
1 2.0.0 18.6.2021 Dana Salingerová

InteliSCADA 2.3.0 New features list 12

You might also like