ELECTRIC-HEAT THERMOSTAT
WHITE-RODGERS (Single Pole)
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
80
PRECAUTIONS
This control is a precision instrument, and should be All wiring must conform to local and national electrical
handled carefully. Rough handling or distorting compo- codes and ordinances.
nents could cause the control to malfunction. Take care
not to push or damage the knob sensing element ! WARNING
during installation.
Do not use on circuits exceeding specified volt-
! CAUTION ages. Higher voltages will damage control and
could cause shock or fire hazard.
To prevent electrical shock and/or equipment
Do not use on inductive loads. Inductive (motor)
damage, disconnect electric power to system, at
loads will damage control and could cause shock
main fuse or circuit breaker box, until installation
or fire hazard.
is complete.
SPECIFICATIONS
Switch Rating: Non-Inductive Temperature Range: 40° to 85°F
22A (2500W) 120 VAC Differential: 1°F
22A (5000W) 240 VAC Switch Action: Open on rise
18A (5000W) 277 VAC Contact Structure: SPST
INSTALLATION
If the heating equipment manufacturer has made provi- 3. It should be mounted as far as possible from undesir-
sions or recommendations for the location of this control, able sources of heat and cold such as:
then follow those instructions. If not, the following sugges- a. Windows and doors
tions should be observed. b. Direct rays from sun
1. The control should be mounted in the wall, approxi- c. Hot water or cold water pipes
mately five feet from the floor, as near as possible to
d. Adjoining outside walls
the centre of the controlled area.
2. It should be mounted on a partitioning wall, not on an
outside wall.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO. PART NO. 37-5427C
9797 REAVIS RD., ST. LOUIS, MO. 63123 Replaces 37-5427B
(314) 577-1300, Fax (314) 577-1517 Printed in U.S.A.
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
9520
(905) 475-4653, FAX (905) 475-4625
WIRING
All wiring must conform to local and national electrical codes and ordinances.
The thermostat may be mounted in any standard 2” x 3” 2. Push the lead wires into the outlet box and mount the
electrical outlet box. For ease of installation use a deep thermostat to the outlet box with screws provided.
type box. Take care not to push or damage the knob sens-
ing element during installation.
! CAUTION 3. Snap on the thermostat cover and turn knob to
USE WITH COPPER CONDUCTORS ONLY. desired setting.
1. Make electrical connection to thermostat leads with
wire nuts or other local code approved devices. All
connections must be tight.
Thermostat
Note: Do not
push on this knob
because calibration Mounting Screw
will be changed
if knob is bent.
BLACK
BLUE
60
70
50
80
LINE LOAD
Mounting Screw
Cover