PROGRAMME:

ELECTRICAL SWITCHGEARS MAINTENANCE (11Kv – 400v )

DURATION : 2 Days (Time : 9.00am -5.30pm)

TARGET GROUP

This course will benefit new and graduate Maintenance Managers,


Engineers, Technicians, Chargeman and Electrical Supervisors, involved
in the maintenance of Electrical Switchgears

COURSE OBJECTIVE

Understand the construction, principles of Operation and Maintenance of


11KV & 415V Switchgears and Transformers

COURSE METHODOLOGY

 Presentation

 Case Studies

 Videos

 Self Audit & Assessment

 Group Work/Exercises for development of practical tools

 Follow-up on Effectiveness of Training

COURSE OUTLINE

MODULE 1: Construction of HV/LV Breakers and their application


-OCBs
-VCBs
-SF6 CBs
-ACBs
Your Quality & Technical Management System Partner
Email : info@icscer.com Website : www.icscer.com
ICS CERTIFICATION (M) SDN BHD

-MCCBs
-Load Break Switches
MODULE 2: Important Factors to Consider in Replacing HV/LV Switchgears:
-Make
-Type
-Size
-Current Rating
-Rupturing Capacity
-General Specifications
MODULE 3: Periodic Maintenance Tests for HV/LV Switchgears
i. Insulation Resistance Test
ii. Pressure Test
iii. O/C & E/F Relay Tests
iv. Bucholz Relay Trip & Alarm Function Tests
iv. CT Test
v. PT Test
vi Earthing Test
vii) Ring Main Cable Tests

MODULE 4: General Maintenance of HV Switchgears & Ancillary Devices


-Circuit Breakers
-Load Break Switches
-Measuring Instruments & Protection Relays
-Battery
-Other General Requirements

MODULE 5: General Maintenance of LV Switchgears & Ancillary Devices


-Air Circuit Breakers
-MCCBs
-Isolators
-Measuring Instruments & Protection Relays

Your Quality & Technical Management System Partner


Email : info@icscer.com Website : www.icscer.com
ICS CERTIFICATION (M) SDN BHD

-Other General Requirements

MODULE 6: General Maintenance & Maintenance Tests for Transformers


-Insulation Test
-Ratio Check
-Insulation Oil Sample Test
-Pressure Test
-Protection Relay Tests
-General Maintenance
MODULE 7: Power Cable Failures
-Cause of Failures
-Types of Power Cable faults
-Methods of Locating Cable Faults
-Checking Cable Fault using a Megger

MODULE 8: Regulatory Requirements for Maintenance of Electrical Installation


-Inspection & Test for the purpose of maintenance of electrical installation
work
-Competent Person to undertake maintenance electrical work
-Adequate Safety precautions to be taken during work
-Requirement for Competent person to issue written instruction
-Preventive Maintenance

MODULE 9: Requirement for Electrical System Audit


-Establish Electrical System Audit Procedure
-Conduct Sub-Contractor Evaluation & Selection
-Appoint Independent Audit Team
-Conduct Scheduled Electric System Audits Annually
-Review Findings with Management and Follow-up Actions

Your Quality & Technical Management System Partner


Email : info@icscer.com Website : www.icscer.com
ICS CERTIFICATION (M) SDN BHD

 Q&A
 Post Test
 Programme Evaluation & Close