Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Proyecto Fotovoltaico Zamora Chinchipe

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Version 7.3.

PVsyst TRIAL
PVsyst - Simulation report
Standalone system

Project: ZAMORA
Variant: Nueva variante de simulación
Standalone system with batteries
System power: 3450 Wp

PVsyst TRIAL
ZAMORA CHINCHIPE-Zamora - Ecuador

PVsyst TRIAL

PVsyst TRIAL
Autor(a)

PVsyst TRIAL
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

Project summary
Geographical Site Situation Project settings
ZAMORA CHINCHIPE-Zamora Latitude -4.07 °S Albedo 0.20
Ecuador Longitude -78.96 °W
Altitude 1003 m
Time zone UTC-5

Meteo data
Zamora
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 15 / 0 ° Constant over the year
Average 11.6 kWh/Day

System information
PV Array Battery pack
Nb. of modules 115 units Technology Lithium-ion, NMC
Pnom total 3450 Wp Nb. of units 1 unit
Voltage 1234 V
Capacity 296 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 4223.05 kWh/year
Missing Energy
Excess (unused)
0.00 kWh/year
1933.35 kWh/year

Project and results summary


Specific production 1224 kWh/kWp/year Perf. Ratio PR
Available solar energy 6449.13 kWh/year

Table of contents
Solar Fraction SF
59.17 %
100.00 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 2/7
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 15 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 11.6 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 30 Wp
PV Array Characteristics

Generic
Poly 30 Wp 36 cells
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Rack JH4 SR32_4P
Lithium-ion, NMC
1 Unit
Number of PV modules 115 units Discharging min. SOC 10.0 %
Nominal (STC) 3450 Wp Stored energy 331.5 kWh
Modules 1 String x 115 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 1234 V
Pmpp 3375 Wp Nominal Capacity 296 Ah (C10)
U mpp 1607 V Temperature Fixed 20 °C
I mpp 2.1 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 3.45 kWp
Total 115 modules
Module area 26.9 m²

Array losses

PVsyst TRIAL
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 12742 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 0.0 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction -0.8 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 3/7
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

Detailed User's needs


Daily household consumers, Constant over the year, average = 11.6 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Lámparas 10 60/lamp 7.0 4200
Focos fluorescentes 3 40/app 8.0 960
Laptops 2 45/app 5.0 450
Nevera 1 24 10
Lavadora 1 2 450
Televisiòn 1 80 tot 5.0 400

PVsyst TRIAL
Planchas 1 200 tot 1.5 300
Consumidores en espera 24.0 4800
Total daily energy 11570

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 4/7
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

Main results
System Production
Useful energy from solar 4223.05 kWh/year Performance Ratio PR 59.17 %
Available solar energy 6449.13 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 1933.35 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 99.7 %
Missing Energy 0.00 kWh/year Static SOW 90.0 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
185.2
153.8
181.6
174.5
GlobEff
kWh/m²
159.3
138.7
172.5
177.1
E_Avail
kWh
508.2
447.8
544.0
562.8
EUnused
kWh
0.0
103.8
176.8
201.6
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
358.7
324.0
358.7
347.1
E_Load
kWh
358.7
324.0
358.7
347.1
SolFrac
ratio
1.000
1.000
1.000
1.000
May 177.1 190.3 602.5 228.3 0.000 358.7 358.7 1.000
June 167.6 184.5 597.8 237.7 0.000 347.1 347.1 1.000
July 171.8 186.3 606.7 234.3 0.000 358.7 358.7 1.000
August 168.2 174.6 571.0 201.6 0.000 358.7 358.7 1.000
September 163.9 159.1 508.4 150.4 0.000 347.1 347.1 1.000
October 170.3 155.8 503.6 132.2 0.000 358.7 358.7 1.000
November 175.8 151.9 492.7 133.5 0.000 347.1 347.1 1.000

PVsyst TRIAL
December 183.1 154.4 503.6 133.2 0.000 358.7 358.7 1.000
Year 2072.9 2004.5 6449.1 1933.4 0.000 4223.1 4223.1 1.000

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 5/7
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

Loss diagram
2073 kWh/m² Global horizontal irradiation

-0.20% Global incident in coll. plane

-3.11% IAM factor on global

2004 kWh/m² * 27 m² coll. Effective irradiation on collectors

efficiency at STC = 13.94% PV conversion

7519 kWh Array nominal energy (at STC effic.)


+0.50% PV loss due to irradiance level

PVsyst TRIAL -9.71%

+0.75%

-2.10%

-1.14%
PV loss due to temperature

Module quality loss

Mismatch loss, modules and strings

Ohmic wiring loss

-29.06% Unused energy (battery full)

4713 kWh Effective energy at the output of the array

PVsyst TRIAL 4516 kWh


-4.02%

-0.21%
-0.04%
0.00%
0.00%
Converter Loss during operation (efficiency)

Converter Loss over nominal conv. power


Converter Loss due to power threshold
Converter Loss over nominal conv. voltage
Converter Loss due to voltage threshold
Converter losses (effic, overload)
Missing Direct use Stored Battery Storage
energy 43.5% 56.5%
+0.81% Battery Stored Energy balance
0.00%
0.0 kWh
-4.69% Battery efficiency loss

-2.13% Charge/Disch. Current Efficiency Loss

PVsyst TRIAL
-0.98% Battery Self-discharge Current
4223 kWh Energy supplied to the user

4223 kWh Energy need of the user (Load)

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 6/7
Project: ZAMORA
Variant: Nueva variante de simulación

PVsyst V7.3.2
VC0, Simulation date:
20/02/23 14:44

PVsyst TRIAL
with v7.3.2

Predef. graphs
Diagrama entrada/salida diaria

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
20/02/23 PVsyst Evaluation mode Page 7/7