Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Selectie Chiller

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Technical Data Sheet

EWYT175B-SSA1+OP204
> Air to water reversible heat pump
> Scroll compressor
> Standard efficiency version
> Standard sound configuration
> R-32 refrigerant

Unit description: Daikin air to water reversible heat pump with hermetic scroll compressors and R32 refrigerant.
Unit colour is ivory White (Munsell code 5Y7.5/1) (±RAL7044).

Compressors: Hermetic orbiting scroll designed for R32 operation and complete with motor over-temperature and
over-current protection devices. Each compressor is equipped with an oil heater that keeps the oil from being
diluted by the refrigerant when the chiller is not running. The compressors are connected in Tandem or Trio
configuration on each refrigerant circuit. Each compressor is mounted on rubber antivibration mounts for a quite
operation. Unit is delivered with complete oil charge.

Water side Heat Exchanger: The unit is equipped with a direct expansion plate to plate heat exchanger. This heat
exchanger is made of stainless-steel brazed plates and covered with a 20mm closed cell insulation material. The
exchanger is equipped with an electric heater for protection against freezing. Water connections are provided with
Victaulic kit.

Air side Heat Exchanger: The air side heat exchanger is manufactured with internally enhanced seamless copper
tubes arranged in a staggered row pattern and mechanically expanded into lanced and rippled aluminum fins with
full fin collars. An integral sub-cooler circuit provides sub-cooling to effectively eliminate liquid flashing and
increase cooling capacity without increasing the power input.

Air side Heat Exchanger fans: The fans are propeller type with high efficiency design blades to maximize
performances. Fan blades are made of glass reinforced resin and each fan is protected by a guard. Parallel Coil units
are equipped as standard with fan speed modulation (phase cut). Double V Coil units (standard and low sound
versions) are equipped with on/off fans and inverter drive is available as an option. Double V Coil units reduced
noise versions are equipped with inverter driven fans as standard.

Refrigerant circuit: Each unit has one or two independent refrigerant circuits and each one includes: Compressors,
Refrigerant, Water Side Heat Exchanger, Air Side Heat Exchanger, Electronic expansion valve, 4-way valve, Sight
glass with moisture indicator, Filter drier, Charging valves, High pressure switch, High pressure transducers, Low
pressure transducers, Oil pressure transducer and Suction temperature sensor.

Electrical panel: Power and control are in the main panel that is manufactured to ensure protection against all
weather conditions. It is IP54 and internally protected against possible accidental contact with live parts when the
doors are open. The main panel is fitted with interlocked main switch door that interrupts power supply when
opening.

Controller: Latest generation MicroTech 4 controller provides an easy to use control environmental. The control
logic is designed to provide maximum efficiency, to continue operation in unusual operating conditions and to
provide a history of unit operation. Sophisticated software with adaptive logic selects the most energy efficient
combination of compressor load, electronic expansion valve position and fans to keep stable operating conditions
and maximize chiller efficiency and reliability. One of the greatest benefits is the easy interface with LonWorks,
Bacnet, Ethernet TCP/IP or Modbus communications.

Specifications are subject to change without any prior notice 13/2/2023 CSS Web 10.38
The certified standard performances and the certified selection tool version can be verified in www.eurovent-certification.com Page 1/4
Technical Data Sheet

EWYT175B-SSA1+OP204
Performances calculated according to EN14511-3:2013

Cooling mode performances


Cooling capacity 139.4 kW Chilled water IN/OUT 11.00 °C / 6.00 °C
Power input 60.10 kW Chilled water flow 7.420 l/s
EER Cooling Efficiency 2.319 kW / kW Water heat exchanger pressure drops 81.6 kPa
Ambient temperature 38.0 °C
Lw / Lp @ 1m 91 dB(A) / 73 dB(A)
SEER / ηs 4.01 / 157.4% Fluid Ethylene glycol 35%
Water heat exchanger fouling factor 1.76E-05.000 m2°C/W
SEER declared according to EN14825, fan coil application 12/7°C (inlet/outlet) water temperatures. Sound power level according to ISO 9614-1. SEER and IPLV.IP refer to standard
unit without options
Heating mode performances
Heating capacity 140.8 kW Heated water IN/OUT 45.00 °C / 50.00 °C
Power input 63.02 kW Heated water flow 7.370 l/s
COP Heating Efficiency 2.235 kW / kW Water heat exchanger pressure drops 79.3 kPa
SCOP / ηs 3.400 / 133.0% Ambient temp dry/wet bulb 0 °C / -1 °C
SCOP declared according to EN14825, average climate, low temperature application Heating performances calculated with defrost effect

Unit information
Compressor type Scroll Refrigerant type R32
Capacity control STEP Air heat exchanger type HFP
Compressor N° 2 Air heat exchanger fans N° 8
Circuit N° 1 Air heat exchanger fans control Phase cut
Refrigerant charge 26 kg Altitude 000 MSL
Water heat exchanger type Plated Heat Exchanger
Actual refrigerant charge depends on the final unit construction, refer to unit nameplate.

Electrical information
Power supply 400 V / 50.0 Hz / 3 Ph Max. inrush current 464 A
Running current 101.71 A Compressor starting method Direct on line
Max. Running current 131 A
Max. current wires sizing 144.1 A
Voltage tolerance ± 10%. Phase Voltage unbalance ± 3%. Electrical data referred to standard unit without options, refer to unit name plate data.

Specifications are subject to change without any prior notice 13/2/2023 CSS Web 10.38
The certified standard performances and the certified selection tool version can be verified in www.eurovent-certification.com Page 2/4
Technical Data Sheet

EWYT175B-SSA1+OP204
Performances calculated according to EN14511-3:2013

Acoustic information
Sound pressure level at 1 m from the unit (rif. 2 x 10-5 Pa)
63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz db(A)
72.0 71.0 67.0 66.0 68.0 68.0 60.0 52.0 72.6
Values referred to Evap. IN/OUT 12/7°C and 35°C Amb., full load operation, standard unit configuration without options. Sound pressure level calculated from sound power level.
Sound pressure in octave band is for information only and not considered binding.

Physical information
Evap. connections size 88.9 mm Length 3426 mm
Width 1211 mm
Weight shipping/operating 1206 kg / 1214 kg Height 1801 mm
Information referred to standard unit configuration without options, refer to certified unit drawing.

Pump curve
Water flow rate [l/s] * 7.420
Evaporator pressure drop 81.6
[kPa] *
Pump water head [kPa] * 217.7
Pump motor power input 3
[kW]
Pump motor current [A] 6.3
Power supply [V/Ph/Hz] 400/3/50
PN 16
Motor protection IP55
Insulation class F
Tank volume [l] 190

* @working conditions

Specifications are subject to change without any prior notice 13/2/2023 CSS Web 10.38
The certified standard performances and the certified selection tool version can be verified in www.eurovent-certification.com Page 3/4
Technical Data Sheet

EWYT175B-SSA1+OP204
Performances calculated according to EN14511-3:2013

Certification notes

Certified in accordance with Eurovent Certification Program: Liquid Chilling Outside the scope of AHRI Air-Cooled Water-Chilling Packages Certification
Packages and Heat Pumps (LCP-HP). Standard ratings are specified in the section Program or not optionally certified, but is rated in accordance with AHRI Standard
"Rating requirements" of the Rating Standards. All standard ratings are verified by 550/590 (I-P) and AHRI Standard 551/591 (SI).
tests conducted in accordance with the following standards: EN 14511-3:2013
(performance testing) and ISO 9614 (acoustic testing).

General notes
For more information about the above selected product, please go to http://www.daikineurope.com/industrial/. Unit performances are reproducible in laboratory
test environment only in accordance to recognized industry standards. This technical data sheet is generated by Daikin Applied Tool software designed and distributed
by Daikin Applied Europe S.p.A. The present software does not constitute an offer binding upon Daikin Applied Europe S.p.A who compiled the content of this
software to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content
and the products and services presented therein. Specifications are subject to change without prior notice. Product images are indicative only and are intended for
illustrative purposes only; pictures may be differed from the ordered product and are subject to change without prior notice. Daikin Applied Europe S.p.A. explicitly
rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this document. All content is
copyrighted by Daikin Applied Europe S.p.A.

The refrigerant charge for this unit is covered by a third party verified reclaimed refrigerant allocation. Reclaimed refrigerant compliant with AHRI700 standard. With
this initiative, Daikin commits in reducing environmental impact of refrigerants, by avoiding emissions related to end-of-life refrigerants’ destruction. Find out more
info at: https://www.daikin.eu/en_us/daikin-blog/building-a-circular-economy.html

Specifications are subject to change without any prior notice 13/2/2023 CSS Web 10.38
The certified standard performances and the certified selection tool version can be verified in www.eurovent-certification.com Page 4/4