MIN3000~7600TL-XH-US

· Batter y Ready for DC Coupled and AC coupled system


· Support backup power and dark start operations
· With Rapid shutdown solution & AFCI integrated
· Integrated EMS, support multiple energy management
modes:self-consumption, zero export,TOU and off-grid
· UL1741SA, CA Rule 21 & HECO compliant
· Built-in 4G/Wi-Fi Comm. with APP. IoT integrated Cloud
and monitoring

www.growatt-america.com
Datasheet MIN3000TL-XH-US MIN3800TL-XH-US MIN5000TL-XH-US MIN6000TL-XH-US MIN7600TL-XH-US

Input Data (PV)


Max. Recommended PV Power(STC) 6000W 7600W 10000W 12000W 15200W
DC/AC Ratio 2
Max. DC System Voltage 600V
Startup Voltage 50V
Nominal Voltage 360V
Operating Voltage Range 50~550V
No. of MPPT 2 2 2 3 3
No. of PV Strings per MPPT 2/2 2/2 2/2 2/2/2 2/2/2
Max. Input Current per MPPT 13.5A
Max. Short-circuit Current per MPPT 16.9A
Input/Output Data (Battery)
I/O Voltage Range 360V~550V
Nominal DC Voltage 400V
I/O DC Current 14.3A
I/O DC Power 5000W
Battery Technology LFP
Battery Capacity per Module 9.9kWh
Scalability Up to 2

Output Data (AC)


AC Nominal Power@240V AC 3000W 3800W 5000W 6000W 7600W
AC Nominal Power@208V AC 2600W 3290W 4330W 5200W 6580W
Max. AC Apparent Power 3000VA 3800VA 5000VA 6000VA 7600VA
Nominal AC Voltage 208V/240V
AC Voltage Range @208V AC @240V AC 183V~229V/211V~264V
AC Grid Frequency 50/60Hz
AC Grid Frequency Range 45~65Hz
Max. Output Current 12.5A 16A 21A 25A 32A
Power Factor(@Nominal Power) >0.99
Adjustable Power Factor 0.8 Leading~0.8 Lagging
THDi <3%
AC Grid Connection Type L1/L2/N/PE

Output Data (Backup)


AC Nominal Power 3000W 3800W 5000W 5000W 5000W
Max. AC Power Output 3680VA 4000VA 6000VA 6000VA 6000VA
Nominal AC Voltage 240V
Max. Output Current 16A 16.7A 25A 25A 25A
THD 5%
Efficiency
Max. Efficiency 98.0% 98.2% 98.4% 98.4%
CEC Efficiency@240V AC 97.0% 97.0% 97.5% 97.0% 97.5%
CEC Efficiency@208V AC 96.5% 97.0% 97.5% 97.0% 97.0%
Protection Devices
DC Reverse-polarity Protection Yes
DC Switch Yes
DC Surge Protection Type II
Insulation Resistance Monitoring Yes
AC Surge Protection Type III
AC Short-circuitS Protection Yes
Ground Fault Monitoring Yes
Grid Monitoring Yes
Anti-islanding Protection Yes
Residual-current Monitoring Unit Yes
AFCI Protection Yes

General Data
Dimensions (W / H / D) 15.75/22.41/6.98 inch (400/569/170.5mm)
Weight 32.3lbs (14.65kg)
Operating Temperature Range –13°F~+140°F (–25 °C ~ +60 °C) de-rating above 113°F
Altitude 9843ft (3000m)
Internal Consumption at Night <1W (for PV inverter)/<5W (for storage inverter)
Cooling Natural Convection
Electronics Protection Degree NEMA4X (IP65)
Relative Humidity 0~95%
Interfaces
RS 485 Yes
WIFI/4G Communication Optional
Warranty: 10 Years Yes(optional for extended 15 and 20 years warranty)
Revenue Grade Meter ANSI C12.20 (meet 0.5% accuracy)
IEEE1547, CA Rule21, Rule14 (HECO Compliant), FCC Part15 Class B, UL1741, UL1741SA,CSA C22.2, UL1699B, UL1741 CRD

GROWATT USA INC. Address: 9227 Reseda Blvd. #435 Northridge, CA 91324. Sales Hotline : 818 800 9455 Service Hotline : 818 800 9177
Email: usa@ginverter.com