FRENIC Lift
FRENIC Lift
FRENIC Lift
Information in this catalog is subject to change without notice. Printed in Japan 2005-9 (I05a/E05) CM 00 FIS
MEH426a
Elevator Inverter
The Series of exclusive inverters for operation of elevators are specially designed
High performance vector control High overload capacity
to have a number of improved features over previous elevator inverters, such as vastly lower torque ripple.
Current response (ACR): 500Hz 200% of rated current for 10s
We have incorporated the functions that customers find most necessary in elevator controls to provide Speed control accuracy: ±0.01% (Overload begins from 80% continuous operation with
an inverter that delivers performance that fits your elevator system. a carrier frequency of 10kHz.)
Higher Performance
Globalization Peripheral support tools
Overload capacity: 200% for 10s
Current response: 5 times greater than previous models (compared with the UD series) EC Directives Inverter support loader software is
Reduction of torque ripple realizes low vibration. Reduced roll-back during starting up. (CE Marking) (EN61800-3, EN50178) provided.
Safety standards (EN954-1) (Approval pending) A multi-function keypad (with backlit LCD)
Sink/source switchable makes it possible to copy or edit the
RS-485 communications (Modbus RTU) is function code data.
Motor capacity
adopted as standard equipment.
5.5 7.5 11 15 18.5 22 30 37 45 55 CAN Open Bus is adopted as standard
(kW)
Three-phase equipment.
400V Under development
2 3
Elevator Inverter
The Series of exclusive inverters for operation of elevators are specially designed
High performance vector control High overload capacity
to have a number of improved features over previous elevator inverters, such as vastly lower torque ripple.
Current response (ACR): 500Hz 200% of rated current for 10s
We have incorporated the functions that customers find most necessary in elevator controls to provide Speed control accuracy: ±0.01% (Overload begins from 80% continuous operation with
an inverter that delivers performance that fits your elevator system. a carrier frequency of 10kHz.)
Higher Performance
Globalization Peripheral support tools
Overload capacity: 200% for 10s
Current response: 5 times greater than previous models (compared with the UD series) EC Directives Inverter support loader software is
Reduction of torque ripple realizes low vibration. Reduced roll-back during starting up. (CE Marking) (EN61800-3, EN50178) provided.
Safety standards (EN954-1) (Approval pending) A multi-function keypad (with backlit LCD)
Sink/source switchable makes it possible to copy or edit the
RS-485 communications (Modbus RTU) is function code data.
Motor capacity
adopted as standard equipment.
5.5 7.5 11 15 18.5 22 30 37 45 55 CAN Open Bus is adopted as standard
(kW)
Three-phase equipment.
400V Under development
2 3
Specifications
Standard specifications for three-phase 400V series Common Specifications
Item Specifications Item Detailed Specifications
Model (FRN LM1S-4 ) 5.5 7.5 11 15 18.5 22 Vector control with PG (Controlled motor type: Induction motor (IM)
Control method
Vector control with PG (Controlled motor type: synchronous motor with permanent magnet)
Applicable motor rating [kW] (*1) 5.5 7.5 11 15 18.5 22
Adjustment
Rated capacity [kVA] (*2) 10.2 14 18 24 29 34 Set value: Variable from 5 to 15kHz (5.5 to 22kW)
Carrier frequency Note) To protect the inverter, the carrier frequency may be reduced automatically in accordance with ambient temperature
Voltage [V] (*3) Three-phase, 380V, 400V/50Hz, 380V, 400V, 440V, 460V/60Hz and output current conditions. (An auto reduction stop function is included.)
Output rating
Rated current [A] (*4) 13.5 18.5 24.5 32.0 39.0 45.0 Maximum speed Converted into inverter output frequency, 120Hz (2-pole: 7,200r/min, 4-pole: 3,600r/min, 6-pole: 2,400r/min) PG frequency:
Overload current rating [A] (10 sec) 27.0 37.0 49.0 64.0 78.0 90.0 100kHz or lower
Overload capacity 200% for 10s Control range Converted into inverter output frequency, 0 to 120 Hz (4-pole: 0 to 3,600 r/min)
Speed control
Control response (*1) 100Hz(Max)
Rated frequency [Hz] 50, 60Hz
Analog setting: ±0.2% or less of the max. speed (25 ± 10°C)
Main power: phases, voltage, frequency Three-phase, 380 to 480V, 50/60Hz Control accuracy (*1)
Multi-step speed setting/Communications setting: ±0.01% or less of the max. speed (-10 to +45°C)
Normal operation
Auxiliary control power input: Phases, voltage, frequency Single-phase, 200 to 480V, 50/60Hz
Analog setting: 1/1,000 of the max. speed
Permissible voltage and frequency fluctuation (*8) Voltage: +10 to -15% (Voltage imbalance within 2% *5), frequency: +5 to -5% Multi-step speed setting (Converted into inverter output frequency): 0.01 Hz (99.99 Hz or lower), 0.1Hz (100.0 to 120.0Hz)
Input power supply
Setting resolution
With DCR Communications: 1/20,000 of the maximum speed or in inverter output frequency conversion, 0.01Hz (fixed)
Rated input current [A] 10.6 14.4 21.1 28.8 35.5 42.2
(*6) Without DCR 17.3 23.2 33.0 43.8 52.3 60.6 External signals (digital input): FWD/STOP commands, REV/STOP commands, Coast-to-stop command, External alarm, Error reset, etc.
Start/stop
Required power capacity [kVA] (*7) 7.4 10 15 20 25 30 Keypad operation: Remote/Local switching permits start and stop operation using the and keys (option).
Multi-step speed command: Through a combination of 3 external signals (digital input) (8 steps)
Auxiliary Phases, voltage, frequency Single-phase, 200 to 480V, 50/60Hz Analog Signal: 0 to ± 10V
control Speed settings
Voltage: +10 to -15%, Frequency: +5 to -5% Multi-function keypad (option): Remote/Local switching permits setting with the and keys.
power input Permissible Voltage and Frequency Fluctuations
Control Functions
Communications: RS-485, CAN Bus (under study)
Braking time [s] 30
Braking
S-curve acceleration/ S-curve acceleration start/end point, s-curve deceleration start/end point and other points are set separately (10 steps).
Duty cycle (%ED) [%] 50
deceleration setting Setting range: 0 to 50%
Minimum connectable resistance value [Ω] 64 48 24 24 16 16
Forced stop, Multi-step speed command (with S-curve acceleration/deceleration), Run command matching timer,
DC REACTOR (DCR) Option Multi-step speed command matching timer, Digital input logical inverse, Digital output logical inverse, Soft start, Stop
Sequence functions
Applicable Safety Standard EN50178: 1997 (Approval pending) frequency continuation, Acceleration/deceleration calculation function cancel
Protective enclosure (IEC60529) IP20 Control Torque control, Speed adjuster feed forward compensation, Vibration suppression observer, Notch filter, Speed adjuster
functions Parameter switching, Digital torque bias, Analog torque bias, Motor parameter tuning, etc.
Cooling system Fan cooling
Exclusive functions Password, unbalanced load compensation, creepless running, battery operation
Weight [kg] 5.6 5.7 7.5 11.1 11.2 11.7
PMSM function Magnet pole position offset tuning
(*1) Fuji Electric’s 4-pole standard motor is used as an example of a applicable motor rating.
(*2) The rated capacity shows the case where the output voltage is 440V.
Installation location Indoors. Free from corrosive or flammable gases, dust or oil mist. (Pollution degree 2 (IEC60664-1)). No exposure to direct sunlight.
(*3) Voltages exceeding the power supply voltage cannot be output. Ambient temperature Open: -10 to +45°C
(*4) The rated current shows the case where the carrier frequency is 10kHz, ambient temperature is 45°C or under, and the root mean squared current in cycle operation is 80% of the inverter’s rated current.
(*5) Voltage imbalance [%] = (Max. voltage [V] – Min. voltage [V]) / 3-phase average voltage [V] x 67 (See IEC61800-3). When using the inverter at an imbalance rate of 2 to 3%, use an optional AC reactor (ACR). Ambient humidity 5 to 95% RH (No condensation)
(*6) Calculations were made based on a power supply capacity of 500 kVA (if the inverter capacity exceeds 50 kVA, the power supply capacity is 10 times the inverter capacity) and a connected power supply %X = 5%.
Environment
(*7) The inverter is equipped with a DC reactor (DCR). Altitude 1,000 m or lower
(*8) These permissible fluctuations are for the main power and the auxiliary control power input.
Note: The 30 kW to 55 kW models are currently under development. 55kW or lower 3mm: 2 to less than 9Hz
2
9.8 m/s : 9 to less than 20Hz
Vibration 2
2 m/s : 20 to less than 55Hz
2
1 m/s : 55 to less than 200Hz
External Dimensions
250
220
[ Unit: mm ]
12 226 12 215
5.5 to 11kW 12 196 12 215
15 to 22kW 2- 10 11.2
11
2- 10 11.2
11
260
238
400
378
11
10
11
10
4 5
Specifications
Standard specifications for three-phase 400V series Common Specifications
Item Specifications Item Detailed Specifications
Model (FRN LM1S-4 ) 5.5 7.5 11 15 18.5 22 Vector control with PG (Controlled motor type: Induction motor (IM)
Control method
Vector control with PG (Controlled motor type: synchronous motor with permanent magnet)
Applicable motor rating [kW] (*1) 5.5 7.5 11 15 18.5 22
Adjustment
Rated capacity [kVA] (*2) 10.2 14 18 24 29 34 Set value: Variable from 5 to 15kHz (5.5 to 22kW)
Carrier frequency Note) To protect the inverter, the carrier frequency may be reduced automatically in accordance with ambient temperature
Voltage [V] (*3) Three-phase, 380V, 400V/50Hz, 380V, 400V, 440V, 460V/60Hz and output current conditions. (An auto reduction stop function is included.)
Output rating
Rated current [A] (*4) 13.5 18.5 24.5 32.0 39.0 45.0 Maximum speed Converted into inverter output frequency, 120Hz (2-pole: 7,200r/min, 4-pole: 3,600r/min, 6-pole: 2,400r/min) PG frequency:
Overload current rating [A] (10 sec) 27.0 37.0 49.0 64.0 78.0 90.0 100kHz or lower
Overload capacity 200% for 10s Control range Converted into inverter output frequency, 0 to 120 Hz (4-pole: 0 to 3,600 r/min)
Speed control
Control response (*1) 100Hz(Max)
Rated frequency [Hz] 50, 60Hz
Analog setting: ±0.2% or less of the max. speed (25 ± 10°C)
Main power: phases, voltage, frequency Three-phase, 380 to 480V, 50/60Hz Control accuracy (*1)
Multi-step speed setting/Communications setting: ±0.01% or less of the max. speed (-10 to +45°C)
Normal operation
Auxiliary control power input: Phases, voltage, frequency Single-phase, 200 to 480V, 50/60Hz
Analog setting: 1/1,000 of the max. speed
Permissible voltage and frequency fluctuation (*8) Voltage: +10 to -15% (Voltage imbalance within 2% *5), frequency: +5 to -5% Multi-step speed setting (Converted into inverter output frequency): 0.01 Hz (99.99 Hz or lower), 0.1Hz (100.0 to 120.0Hz)
Input power supply
Setting resolution
With DCR Communications: 1/20,000 of the maximum speed or in inverter output frequency conversion, 0.01Hz (fixed)
Rated input current [A] 10.6 14.4 21.1 28.8 35.5 42.2
(*6) Without DCR 17.3 23.2 33.0 43.8 52.3 60.6 External signals (digital input): FWD/STOP commands, REV/STOP commands, Coast-to-stop command, External alarm, Error reset, etc.
Start/stop
Required power capacity [kVA] (*7) 7.4 10 15 20 25 30 Keypad operation: Remote/Local switching permits start and stop operation using the and keys (option).
Multi-step speed command: Through a combination of 3 external signals (digital input) (8 steps)
Auxiliary Phases, voltage, frequency Single-phase, 200 to 480V, 50/60Hz Analog Signal: 0 to ± 10V
control Speed settings
Voltage: +10 to -15%, Frequency: +5 to -5% Multi-function keypad (option): Remote/Local switching permits setting with the and keys.
power input Permissible Voltage and Frequency Fluctuations
Control Functions
Communications: RS-485, CAN Bus (under study)
Braking time [s] 30
Braking
S-curve acceleration/ S-curve acceleration start/end point, s-curve deceleration start/end point and other points are set separately (10 steps).
Duty cycle (%ED) [%] 50
deceleration setting Setting range: 0 to 50%
Minimum connectable resistance value [Ω] 64 48 24 24 16 16
Forced stop, Multi-step speed command (with S-curve acceleration/deceleration), Run command matching timer,
DC REACTOR (DCR) Option Multi-step speed command matching timer, Digital input logical inverse, Digital output logical inverse, Soft start, Stop
Sequence functions
Applicable Safety Standard EN50178: 1997 (Approval pending) frequency continuation, Acceleration/deceleration calculation function cancel
Protective enclosure (IEC60529) IP20 Control Torque control, Speed adjuster feed forward compensation, Vibration suppression observer, Notch filter, Speed adjuster
functions Parameter switching, Digital torque bias, Analog torque bias, Motor parameter tuning, etc.
Cooling system Fan cooling
Exclusive functions Password, unbalanced load compensation, creepless running, battery operation
Weight [kg] 5.6 5.7 7.5 11.1 11.2 11.7
PMSM function Magnet pole position offset tuning
(*1) Fuji Electric’s 4-pole standard motor is used as an example of a applicable motor rating.
(*2) The rated capacity shows the case where the output voltage is 440V.
Installation location Indoors. Free from corrosive or flammable gases, dust or oil mist. (Pollution degree 2 (IEC60664-1)). No exposure to direct sunlight.
(*3) Voltages exceeding the power supply voltage cannot be output. Ambient temperature Open: -10 to +45°C
(*4) The rated current shows the case where the carrier frequency is 10kHz, ambient temperature is 45°C or under, and the root mean squared current in cycle operation is 80% of the inverter’s rated current.
(*5) Voltage imbalance [%] = (Max. voltage [V] – Min. voltage [V]) / 3-phase average voltage [V] x 67 (See IEC61800-3). When using the inverter at an imbalance rate of 2 to 3%, use an optional AC reactor (ACR). Ambient humidity 5 to 95% RH (No condensation)
(*6) Calculations were made based on a power supply capacity of 500 kVA (if the inverter capacity exceeds 50 kVA, the power supply capacity is 10 times the inverter capacity) and a connected power supply %X = 5%.
Environment
(*7) The inverter is equipped with a DC reactor (DCR). Altitude 1,000 m or lower
(*8) These permissible fluctuations are for the main power and the auxiliary control power input.
Note: The 30 kW to 55 kW models are currently under development. 55kW or lower 3mm: 2 to less than 9Hz
2
9.8 m/s : 9 to less than 20Hz
Vibration 2
2 m/s : 20 to less than 55Hz
2
1 m/s : 55 to less than 200Hz
External Dimensions
250
220
[ Unit: mm ]
12 226 12 215
5.5 to 11kW 12 196 12 215
15 to 22kW 2- 10 11.2
11
2- 10 11.2
11
260
238
400
378
11
10
11
10
4 5
Basic Connection Diagram Options
Option card
PG card for driving synchronous motors through parallel interface: OPC-LM1-PP
External braking
resistor DB Appearance Specifications
(Note 1) 2 (CM)
DC reactor DCR (THR) (Note 7) Incremental signal: A-phase, B-phase (5V line driver)
P DB 1
G Absolute position signal: Max. 4 bit
(Note 2)
Molded case circuit PG power output: 5V ± 5%
Main circuit
breaker (MCCB) or
earth leakage circuit P1 P(+) DB N(-) Max. wiring length: 20m
breaker (ELCB) Max. input frequency: 100kHz
SR
Power supply L1/R U
Motor
3-phase L2/S V
380 to 480V M
50/60Hz L3/T W
Auxiliary (Note 3) PG card for driving synchronous motors through Endat interface: OPC-LM1-PS
control (R0)
power input (T0) Appearance Specifications
200 to 480V
50/60Hz G Grounding
Grounding terminal G Incremental signal: A-phase, B-phase (sine wave, 1Vpp)
terminal
Absolute position signal: Serial interface EnDat 2.1
Control circuit
PG power output: 5V ± 5% 300mA(Max.)
[12]
Voltage input for settings (+) +DC15V (PO)
-10V to 0 to +10V (-) Applicable PG: HEIDENHAIN, ECN1313
[11] +DC12V (PA) Max. wiring length: 20m
Analog Voltage input for settings (+) (PB)
PG
inputs -10V to 0 to +10V (-) [V2] Max. input frequency: 50kHz
(*5) (PZ)
0V Pulse encoder
[C1] (CM) (Note 6) (Pulse generator)
Current input for settings (+)
0V SINK
4mA to 20mA (-)
[11] (*6)
Keypad communications common to
RS-485 (Modbus RTU)
(DX+)
(DX-)
SOURCE
30A
Keypad (TP-G1-CLS)
RJ45 30 30B Alarm relay output (for any fault)
30C Appearance Specifications
(PLC)
+DC24V
Communications
<Y5C>
(FWD) <Y5A> Relay output Communications protocol: Modbus-RTU
(REV)
0V Connection terminal: RJ-45 connector
(CM) (Note 5)
(X1) <Y4>
(X2) Data display: 7-segment LED, 5 digits, LCD display
(X3) <Y3>
Digital Keypad operation keys:
(X4) <Y2>
inputs Motor operation keys:
(X5) <Y1> Transistor
Display
(X6) outputs LED display: For Run ( ) 1 LED
(X7) (Note 5) <CMY>
<PAO> LCD display: <Indicator display>
(X8) Hz, A, V, %, r/min, m/min, kW, x10, min, sec, PID, FWD, REV, STOP,
(EN) <PBO> REM, LOC, COMM, JOG, HAND
(CM) <Display languages (compatible with 3 languages)>
0V
(Note 4) (Note 5) • Chinese, Japanese, English
(CAN+) (CAN-)(SHLD)
(Note 1) Before connecting a DC REACTOR (DCR) (option), remove the jumper bar between terminal [PI] and terminal [P+].
(Note 2) To protect the circuit from overcurrent, install the recommended molded-case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (equipped with overcurrent
DC Reactor
protection function) on the inverter’s input side (primary circuit). Do not use a circuit breaker that exceeds the recommended capacity.
(Note 3) Connect to the auxiliary control power input if you want to activate only the control circuit and
Power Applicable
AC REACTOR P1 P(+)
establish the inverter stand-by state with the main circuit open. The inverter can be operated by Power ELCB Radio noise filter Electromagnetic Dimensions (mm) Weight
wiring to the main circuit without wiring to this terminal.
supply Noise filter contactor
L1/R supply motor Inverter type Reactor type
When connecting an earth leakage circuit breaker (ELCB) to this terminal, connect the terminals
L2/S
voltage rating W W1 D D1 D2 H Mounting Terminal (kg)
L3/T (kW) hole hole
R0 and T0 to the ELCB output side. If they are connected to the ELCB input side, the ELCB will
6×9
malfunction. This is because the inverter input terminal is for three-phase but the terminals R0 Isolation transformer
5.5 FRN5.5LM1S-4 DCR4-5.5 86 71 100 80 20 110 M4 2.6
and T0 are for single-phase. If connecting the ELCB input side to the terminals R0 and T0, be
R0
sure to connect an isolation transformer or an auxiliary B-contact of the electromagnetic
7×11
Inverter
or T0
D1
DC/DC control power 7.5 FRN7.5LM1S-4 DCR4-7.5 111 95 100 80 24 130 M5 4.2
D
contactor in the position indicated in the diagram below.
H
(Note 4) Use shielded or twisted cables as the control signal wires, and ground the shielded cables. To
prevent malfunction due to noise, keep control signal wires away from the main circuit wires as Auxiliary B-contact of electromagnetic contactor 11 FRN11LM1S-4 DCR4-11 111 95 100 80 24 130 7×11 M5 4.3
far as possible (at least 10 cm) and never run them in the same duct together. If they need to cross with each other, lay them at right angles.
3-phase
(Note 5) The common terminals [11], (CM) and (CMY) in the control circuit are independent of each other (isolated). 400V 15 FRN15LM1S-4 DCR4-15 146 124 120 96 15 171 7×11 M5 5.9
(Note 6) Use shielded cables for wiring. Treat the shielded wire sheath according to the pulse encoder specifications and the connecting conditions with the host controller. The figure
7×11
shows the shielded cable sheath connected with the motor’s grounding cable and the inverter side in open state. Malfunction due to noise, if any, may be improved by
W1 18.5 FRN18.5LM1S-4 DCR4-18.5 146 124 120 96 25 171 M6 7.2
connecting the inverter side to CM. D2
(Note 7) When using the (THR) function, assign the external alarm function (E01 to 09: 9) to any of the terminals (X1) to (X9). W
4-G Mounting hole 22 FRN22LM1S-4 DCR4-22 146 124 120 96 25 171 7×11 M6 7.2
6 7
Basic Connection Diagram Options
Option card
PG card for driving synchronous motors through parallel interface: OPC-LM1-PP
External braking
resistor DB Appearance Specifications
(Note 1) 2 (CM)
DC reactor DCR (THR) (Note 7) Incremental signal: A-phase, B-phase (5V line driver)
P DB 1
G Absolute position signal: Max. 4 bit
(Note 2)
Molded case circuit PG power output: 5V ± 5%
Main circuit
breaker (MCCB) or
earth leakage circuit P1 P(+) DB N(-) Max. wiring length: 20m
breaker (ELCB) Max. input frequency: 100kHz
SR
Power supply L1/R U
Motor
3-phase L2/S V
380 to 480V M
50/60Hz L3/T W
Auxiliary (Note 3) PG card for driving synchronous motors through Endat interface: OPC-LM1-PS
control (R0)
power input (T0) Appearance Specifications
200 to 480V
50/60Hz G Grounding
Grounding terminal G Incremental signal: A-phase, B-phase (sine wave, 1Vpp)
terminal
Absolute position signal: Serial interface EnDat 2.1
Control circuit
PG power output: 5V ± 5% 300mA(Max.)
[12]
Voltage input for settings (+) +DC15V (PO)
-10V to 0 to +10V (-) Applicable PG: HEIDENHAIN, ECN1313
[11] +DC12V (PA) Max. wiring length: 20m
Analog Voltage input for settings (+) (PB)
PG
inputs -10V to 0 to +10V (-) [V2] Max. input frequency: 50kHz
(*5) (PZ)
0V Pulse encoder
[C1] (CM) (Note 6) (Pulse generator)
Current input for settings (+)
0V SINK
4mA to 20mA (-)
[11] (*6)
Keypad communications common to
RS-485 (Modbus RTU)
(DX+)
(DX-)
SOURCE
30A
Keypad (TP-G1-CLS)
RJ45 30 30B Alarm relay output (for any fault)
30C Appearance Specifications
(PLC)
+DC24V
Communications
<Y5C>
(FWD) <Y5A> Relay output Communications protocol: Modbus-RTU
(REV)
0V Connection terminal: RJ-45 connector
(CM) (Note 5)
(X1) <Y4>
(X2) Data display: 7-segment LED, 5 digits, LCD display
(X3) <Y3>
Digital Keypad operation keys:
(X4) <Y2>
inputs Motor operation keys:
(X5) <Y1> Transistor
Display
(X6) outputs LED display: For Run ( ) 1 LED
(X7) (Note 5) <CMY>
<PAO> LCD display: <Indicator display>
(X8) Hz, A, V, %, r/min, m/min, kW, x10, min, sec, PID, FWD, REV, STOP,
(EN) <PBO> REM, LOC, COMM, JOG, HAND
(CM) <Display languages (compatible with 3 languages)>
0V
(Note 4) (Note 5) • Chinese, Japanese, English
(CAN+) (CAN-)(SHLD)
(Note 1) Before connecting a DC REACTOR (DCR) (option), remove the jumper bar between terminal [PI] and terminal [P+].
(Note 2) To protect the circuit from overcurrent, install the recommended molded-case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (equipped with overcurrent
DC Reactor
protection function) on the inverter’s input side (primary circuit). Do not use a circuit breaker that exceeds the recommended capacity.
(Note 3) Connect to the auxiliary control power input if you want to activate only the control circuit and
Power Applicable
AC REACTOR P1 P(+)
establish the inverter stand-by state with the main circuit open. The inverter can be operated by Power ELCB Radio noise filter Electromagnetic Dimensions (mm) Weight
wiring to the main circuit without wiring to this terminal.
supply Noise filter contactor
L1/R supply motor Inverter type Reactor type
When connecting an earth leakage circuit breaker (ELCB) to this terminal, connect the terminals
L2/S
voltage rating W W1 D D1 D2 H Mounting Terminal (kg)
L3/T (kW) hole hole
R0 and T0 to the ELCB output side. If they are connected to the ELCB input side, the ELCB will
6×9
malfunction. This is because the inverter input terminal is for three-phase but the terminals R0 Isolation transformer
5.5 FRN5.5LM1S-4 DCR4-5.5 86 71 100 80 20 110 M4 2.6
and T0 are for single-phase. If connecting the ELCB input side to the terminals R0 and T0, be
R0
sure to connect an isolation transformer or an auxiliary B-contact of the electromagnetic
7×11
Inverter
or T0
D1
DC/DC control power 7.5 FRN7.5LM1S-4 DCR4-7.5 111 95 100 80 24 130 M5 4.2
D
contactor in the position indicated in the diagram below.
H
(Note 4) Use shielded or twisted cables as the control signal wires, and ground the shielded cables. To
prevent malfunction due to noise, keep control signal wires away from the main circuit wires as Auxiliary B-contact of electromagnetic contactor 11 FRN11LM1S-4 DCR4-11 111 95 100 80 24 130 7×11 M5 4.3
far as possible (at least 10 cm) and never run them in the same duct together. If they need to cross with each other, lay them at right angles.
3-phase
(Note 5) The common terminals [11], (CM) and (CMY) in the control circuit are independent of each other (isolated). 400V 15 FRN15LM1S-4 DCR4-15 146 124 120 96 15 171 7×11 M5 5.9
(Note 6) Use shielded cables for wiring. Treat the shielded wire sheath according to the pulse encoder specifications and the connecting conditions with the host controller. The figure
7×11
shows the shielded cable sheath connected with the motor’s grounding cable and the inverter side in open state. Malfunction due to noise, if any, may be improved by
W1 18.5 FRN18.5LM1S-4 DCR4-18.5 146 124 120 96 25 171 M6 7.2
connecting the inverter side to CM. D2
(Note 7) When using the (THR) function, assign the external alarm function (E01 to 09: 9) to any of the terminals (X1) to (X9). W
4-G Mounting hole 22 FRN22LM1S-4 DCR4-22 146 124 120 96 25 171 7×11 M6 7.2
6 7
Elevator Inverter
Information in this catalog is subject to change without notice. Printed in Japan 2005-9 (I05a/E05) CM 00 FIS
MEH426a