ICC-ES Evaluation Report ESR-2461
ICC-ES Evaluation Report ESR-2461
ICC-ES Evaluation Report ESR-2461
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 03 00 00—CONCRETE body, expansion clip, nut, and washer. The anchor is
Section: 03 16 00—Concrete Anchors illustrated in Figure 1.
The stud anchor body has a tapered mandrel formed on
DIVISION: 05 00 00—METALS
the installed end of the anchor, and a threaded section at
Section: 05 05 19—Post-Installed Concrete Anchors
the opposite end. The taper of the mandrel increases in
diameter toward the installed end of the anchor. The
REPORT HOLDER:
three-segment expansion clip wraps around the tapered
mandrel. Before installation, this expansion clip is free to
MKT METALL-KUNSTSTOFF-TECHNIK GmbH & Co.
rotate about the mandrel. The anchor is installed in a
KG
predrilled hole. When the anchor is set using an applied
torque to the hex nut, the mandrel is drawn into the
EVALUATION SUBJECT:
expansion clip, which engages the drilled hole and transfers
the load to the base material. Pertinent dimensions are as
MKT SRS TZ ANCHORS FOR CRACKED AND
set forth in Table 1.
UNCRACKED CONCRETE
3.1.2 SRS TZ Carbon Steel: The stud elements of carbon
1.0 EVALUATION SCOPE steel anchors are manufactured from carbon steel
Compliance with the following codes: complying with DIN EN 10263-3 and have a minimum
5 μm (0.0002 inch) zinc plating. The expansion clip
2018, 2015, 2012 and 2009 International Building Code®
elements of the carbon steel anchors are fabricated from
(IBC)
stainless steel complying with AISI/SAE 304 or 316. The
2018, 2015, 2012 and 2009 International Residential carbon steel hex nut complies with ASTM A563, Grade A.
Code® (IRC) The carbon steel washer complies with ANSI/ASME
Property evaluated: B18.22.1 or EN ISO 7089.
Structural 3.1.3 SRS TZ 304 Stainless Steel: The stud elements of
2.0 USES 304 stainless steel anchors are manufactured from stainless
steel complying with AISI/SAE 304 or 316. The expansion
The MKT SRS TZ carbon and stainless steel expansion
clip elements are fabricated from stainless steel complying
anchors are used to resist static, wind and seismic
with AISI/SAE 304 or 316. The stainless steel hex nuts
(Seismic Design Categories A through F) tension and shear
comply with the chemical and dimensional requirements of
loads in cracked and uncracked normal-weight or
ASTM F594, 304 alloy group. The stainless steel washer
lightweight concrete having a specified compressive
complies with ANSI/ASME B18.22.1 or EN ISO 7089, 304
strength, f′c, ranging from 2,500 psi to 8,500 psi
alloy group.
(17.2 MPa to 58.6 MPa). The MKT SRS TZ carbon steel
expansion anchors are also used to resist static, wind and 3.1.4 SRS TZ 316 Stainless Steel: The stud elements of
seismic tension and shear loads in cracked and uncracked 316 stainless steel anchors are manufactured from stainless
normal-weight or sand-lightweight concrete over metal deck steel complying with AISI/SAE 316. The expansion clip
having a minimum specified compressive strength, f′c, of elements are fabricated from stainless steel complying with
3,000 psi (20.7 MPa). AISI/SAE 316. The stainless steel hex nuts comply with the
The MKT SRS TZ anchoring system complies with chemical and dimensional requirements of ASTM F594, 316
anchors as described in Section 1901.3 of the 2018 and alloy group. The stainless steel washer complies with
2015 IBC, Section 1909 of the 2012 IBC and Section 1912 ANSI/ASME B18.22.1 or EN ISO 7089, 316 alloy group.
of the 2009 IBC. The anchor system is an alternative to cast- 3.2 Concrete:
in-place anchors described in Section 1908 of the 2012 IBC,
and Section 1911 of the 2009 IBC. The anchors may also Normal-weight and lightweight concrete must comply with
be used where an engineered design is submitted in Sections 1903 and 1905 of the IBC.
accordance with Section R301.1.3 of the IRC. 3.3 Steel Deck Panels:
3.0 DESCRIPTION
Steel deck panels must comply with the configuration in
3.1 MKT SRS TZ Anchors: Figure 4 and have a minimum base-metal thickness of 0.035
3.1.1 General: SRS TZ anchors are torque-controlled, inch (0.889 mm) [20 gage]. Steel deck must comply with the
mechanical expansion anchors consisting of a stud anchor requirements of ASTM A653/A653M SS Grade 33, and
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2020 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 10
ESR-2461 | Most Widely Accepted and Trusted Page 2 of 10
have a minimum yield strength of 33 ksi accordance with ACI 318-14 17.4.2 or ACI 318-11 D.5.2, as
(228 MPa). applicable, is not required.
4.0 DESIGN AND INSTALLATION 4.1.4 Requirements for Static Pullout Strength in
4.1 Strength Design: Tension: The nominal pullout strength of a single anchor in
tension in accordance with ACI 318-14 17.4.3 or ACI 318-
4.1.1 General: Design strength of anchors complying with 11 D.5.3, as applicable, in cracked and uncracked concrete,
the 2018 and 2015 IBC as well as Section R301.1.3 Np,cr and Np,uncr, respectively, is given in Table 3 of this
of the 2018 and 2015 IRC, must be determined in report. For all design cases, ψc,P = 1.0.
accordance with ACI 318-14 Chapter 17 and this report.
The nominal pullout strength in cracked concrete may be
Design strength of anchors complying with the 2012 IBC adjusted by calculations according to Eq-1:
as well as Section R301.1.3 of the 2012 IRC, must be
.
determined in accordance with ACI 318-11 Appendix D and 𝑁 𝑁 (lb, psi) (Eq.-1)
, ,
this report. ,
.
Design strength of anchors complying with the 2009 IBC 𝑁 𝑁 (N, MPa)
, ,
as well as Section R301.1.3 of the 2009 IRC, must be .
determined in accordance with ACI 318-08 Appendix D and where f′c is the specified concrete compressive strength.
this report.
In regions of a concrete member where analysis indicates
A design example according to the 2018, 2015 and 2012 no cracking in accordance with ACI 318-14 17.4.3.6 or ACI
IBC is given in Figure 5 of this report. Design parameters 318-11 D.5.3.6, as applicable, the nominal pullout strength
are based on the 2018 and 2015 IBC (ACI 318-14) and the in tension can be adjusted by calculations according to Eq-
2012 IBC (ACI 318-11) unless noted otherwise in Sections 2.
4.1.1 through 4.1.12 of this report. The strength design of
.
anchors must comply with ACI 318-14 17.3.3 or ACI 318-11 𝑁 𝑁 (lb, psi) (Eq.-2)
, ,
D.4.1, as applicable, except as required in ACI 318-14 ,
17.2.3 or ACI 318-11 D.3.3, as applicable. .
𝑁 , 𝑁 , (N, MPa)
Strength reduction factors, , as given in ACI 318-14 .
17.3.3 or ACI 318-11 D.4.3, as applicable, must be used for Where values for nominal pullout strengths, Np,cr or Np,uncr,
load combinations calculated in accordance with Section are not provided for the 5/8-inch-diameter (15.9 mm) anchors
1605.2 of the IBC and Section 5.3 of ACI 318-14 or Section in Table 3, the pullout strength does not need to be
9.2 of ACI 318-11, as applicable. Strength reduction factors, considered.
, as given in ACI 318-11 D.4.4 must be used for load
combinations calculated in accordance with ACI 318-11 The pullout strength in cracked concrete of the carbon
Appendix C. steel anchors installed in the soffit of sand-lightweight or
normal-weight concrete over profile steel deck floor and roof
The value of f′c used in the calculations must be limited to assemblies, as shown in Figure 4, is provided in Table 5.
8,000 psi (55.2 MPa), maximum, in accordance with ACI The nominal pullout strength in cracked concrete must be
318-14 17.2.7 or ACI 318-11 D.3.7. calculated according to Eq-1, whereby the value Np,deck,cr
Design parameters are provided in Tables 3 and 4 of this must be substituted for Np,cr and the value of
report. Strength reduction factors, , corresponding to 3,000 psi (20.7 MPa) must be substituted for the value of
ductile steel elements may be used. 2,500 psi (17.2 MPa) in the denominator. In regions of a
concrete member where analysis indicates no cracking in
4.1.2 Requirements for Static Steel Strength in accordance with ACI 318-14 17.4.3.6 or ACI 318-11 D.5.3.6,
Tension: The nominal steel strength in tension, Nsa, in as applicable, the nominal pullout strength in uncracked
accordance with ACI 318-14 17.4.1.2 or ACI 318-11 D.5.1.2, concrete must be calculated according to Eq-2, whereby the
is given in Table 3 of this report. Strength reduction factors, value of Np,deck,uncr must be substituted for Np,uncr and the
sa, corresponding to ductile steel elements as described in value of 3,000 psi (20.7 MPa) must be substituted for the
Table 3 must be used. value of 2,500 psi (17.2 MPa) in the denominator. The use
4.1.3 Requirements for Static Concrete Breakout of SRS TZ stainless steel anchors installed in the soffit of
Strength in Tension: The nominal concrete breakout concrete on steel deck assemblies is beyond the scope of
strength of a single anchor or group of anchors in tension, this report. For all design cases
Ncb and Ncbg, respectively, must be calculated according to Ψc,p = 1.0.
ACI 318-14 17.4.2 or ACI 318-11 D.5.2., as applicable, 4.1.5 Requirements for Static Steel Strength in Shear:
modified as described in this section. The basic concrete The nominal steel strength in shear, Vsa, in accordance with
breakout strength in tension, Nb, must be calculated ACI 318-14 17.5.1.2 or ACI 318-11 D.6.1.2, as applicable,
according to ACI 318-14 17.4.2.2 or ACI 318-11 D.5.2.2, as is given in Table 4 of this report and must be used in lieu of
applicable, using the values of hef and kcr as given in Table the values derived by calculations from ACI 318-14 Eq.
3. The value of f′c used in the calculations must be limited to 17.5.1.2b or ACI 318-11, Eq. D-29, as applicable. Strength
a maximum of 8,000 psi (55.2 MPa), in accordance with ACI
reduction factors, sa, corresponding to ductile steel
318-14 17.2.7 or ACI 318-11 D.3.7, as applicable. The
elements as described in Table 4 must be used.
nominal concrete breakout strength in tension in regions
where analysis indicates no cracking at service loads in The shear strength, Vsa,deck, of anchors installed in the
accordance with ACI 318-14 17.4.2.6 or ACI 318-11 D.5.2.6, soffit of sand-lightweight or normal-weight concrete over
as applicable, must be calculated with ψc,N = 1.0 and kuncr profile steel deck floor and roof assemblies, as shown in
as given in Table 3. Figure 4, is given in Table 5.
For SRS TZ carbon steel anchors installed in the soffit of 4.1.6 Requirements for Static Concrete Breakout
sand-lightweight or normal-weight concrete over profile Strength of Anchor in Shear: The nominal concrete
steel deck floor and roof assemblies, as shown in Figure 4, breakout strength of an anchor or group of anchors in shear,
determination of the concrete breakout strength in Vcb and Vcbg, respectively, must be calculated in accordance
ESR-2461 | Most Widely Accepted and Trusted Page 3 of 10
with ACI 318-14 17.5.2 or ACI 318-11 D.6.2, as applicable, A value for nominal pullout strengths, Np,eq, is not provided
modified as described in this section. The basic concrete for the 5/8-inch-diameter (15.9 mm) anchors in Table 3,
breakout strength in shear, Vb, must be calculated in hence the pullout strength in tension for seismic loads does
accordance with ACI 318-14 17.5.2.2 or ACI 318-11 D.6.2.2, not need to be considered.
as applicable, using the values of le and da described in
4.1.8.2 Seismic Shear: The nominal concrete breakout
Table 4 of this report. The value of f′c used for calculation strength and pryout strength for anchors in shear must be
purposes must not exceed 8,000 psi (55.2 MPa) in calculated in accordance with ACI 318-14 17.5.2 and 17.5.3
accordance with ACI 318-14 17.2.7 or ACI 318-11 D.3.7. or ACI 318-11 D.6.2 and D.6.3, respectively, as as
For anchors installed in the soffit of sand-lightweight or applicable, as described in Sections 4.1.6 and 4.1.7 of this
normal-weight concrete over profile steel deck floor and roof report. In accordance with ACI 318-14 17.5.1.2 or ACI 318-
assemblies, as shown in Figure 4, calculation of the 11 D.6.1.2, as applicable, the appropriate value for nominal
concrete breakout strength in accordance with ACI 318-14 steel strength in shear for seismic loads, Vsa,eq or Vsa,deck,eq,
17.5.2 or ACI 318-11 D.6.2 is not required. described in Tables 4 and 5, must be used in lieu of Vsa.
4.1.7 Requirements for Static Concrete Pryout 4.1.9 Interaction of Tensile and Shear Forces: The
Strength of Anchor in Shear: Static nominal concrete interaction of tensile and shear forces must be calculated in
pryout shear strengths of an anchor or group of anchors, Vcp accordance with ACI 318-14 17.6 or ACI 318-11 Section
and Vcpg, respectively, must be calculated in accordance D.7.
with ACI 318-14 17.5.3 or ACI 318-11 D.6.3, as applicable, 4.1.10 Requirements for Critical Edge Distance: In
modified by using the value of kcp described in Table 4 of applications where c<cac and supplemental reinforcement to
this report and the value of Ncb or Ncbg as calculated in control splitting of the concrete is not present, the concrete
accordance with Section 4.1.3 of this report. breakout strength in tension for uncracked concrete,
For anchors installed in the soffit of sand-lightweight or calculated according to ACI 318-14 17.4.2 or ACI 318-11
normal-weight concrete over profile steel deck floor and roof D.5.2, as applicable, must be further multiplied by the factor
assemblies, as shown in Figure 4, calculation of the of Ψcp,N given by the following equation:
concrete pryout strength in accordance with ACI 318-14 c
17.5.3 or ACI 318-11 D.6.3 is not required.
ψcp,N = (Eq.-4)
cac
4.1.8 Requirements for Seismic Design: For load whereby the factor Ψcp,N need not be taken as less than
combinations including seismic, the design must be 1.5hef
. For all other cases Ψcp,N=1.0. In lieu of ACI 318-14
performed in accordance with ACI 318-14 17.2.3 or ACI cac
318-11 D.3.3, as applicable and as modified by Section 17.7.6 or ACI 318-11 D.8.6, the critical edge distance, cac,
1905.1.8 of the 2018 and 2015 IBC. For the 2012 IBC, required to develop the basic concrete breakout strength of
Section 1905.1.9 shall be omitted. Modifications to ACI 318- a post-installed anchor in uncracked concrete without
08 D.3.3 shall be applied under Section 1908.1.9 of the supplementary reinforcement, given in Table 3, must be
2009 IBC. used.
The anchors comply with ACI 318-14 2.3 or ACI 318-11 4.1.11 Requirements for Minimum Member Thickness,
D.1, as applicable, as ductile steel elements and must be Minimum Anchor Spacing, and Minimum Edge
designed in accordance with ACI 318-14 17.2.3.4, 17.2.3.5, Distance: In lieu of ACI 318-14 17.7.1 and 17.7.3 or ACI
17.2.3.6 or 17.2.3.7; ACI 318-11 D.3.3.4, D.3.3.5, D.3.3.6 or 318-11 D.8.1 and D.8.3, respectively, as applicable, values
D.3.3.7; ACI 318-08 D.3.3.4, D.3.3.5 and D.3.3.6 or ACI of cmin and smin as given in Table 1 of this report must be
318-05 D.3.3.4 or D.3.3.5, as applicable. used. In lieu of ACI 318-14 17.7.5 or ACI 318 D.8.5, as
applicable, minimum member thicknesses, hmin, as given in
4.1.8.1 Seismic Tension: The nominal steel strength and
Table 1 of this report must be used. Additional combinations
the nominal concrete breakout strength for anchors in
for minimum edge distance, cmin and spacing, smin may be
tension must be calculated in accordance with ACI 318-14
derived by linear interpolation between the given boundary
17.4.1 and 17.4.2 or ACI 318 D.5.1 and D.5.2, respectively,
values. The interpolation is shown in Figure 3. For anchors
as applicable, as described in Sections 4.1.2 and 4.1.3 of
installed through the soffit of steel deck assemblies, the
this report and taking into account the corresponding values
minimum anchor spacing along the flute must be the greater
given in Tables 1, 3, 4 and 5.
of 3.0hef or 1.5 times the flute width in accordance with
In accordance with ACI 318-14 17.4.3.2 or ACI 318-11 Figure 4.
D.5.3.2, as applicable, the appropriate value for nominal
pullout strength in tension for seismic loads, Np,eq or 4.1.12 Lightweight Concrete: For the use of anchors in
lightweight concrete, the modification factor λa equal to 0.8λ
Np,deck,cr, described in Tables 3 and 5, must be used in lieu
of Npn. The values of Np,eq can be adjusted by calculations is applied to all values of f c affecting Nn and Vn.
according to Eq-3:
. For ACI 318-14 (2018 or 2015 IBC), ACI 318-11 (2012
𝑁 , , 𝑁 , (lb, psi) (Eq.-3) IBC) and ACI 318-08 (2009 IBC), λ shall be determined in
,
accordance with the corresponding version of ACI 318.
.
𝑁 , , 𝑁 , (N, MPa) For anchors installed in the soffit of sand-lightweight
.
concrete-filled steel deck and floor and roof assemblies,
In addition, for anchors installed in the soffit of sand- further reduction of the pullout values provided in this report
lightweight or normal-weight concrete over profile steel deck is not required.
floor and roof assemblies, the nominal pullout strength in
tension for seismic loads must be calculated according to 4.2 Allowable Stress Design (ASD):
Eq-3, whereby the value Np,deck,cr must be substituted for 4.2.1 General: Design strengths for use with allowable
Np,eq and the value of 3,000 psi (20.7 MPa) must be stress design (ASD) load combinations calculated in
substituted for the value of 2,500 psi (17.2 MPa) in the accordance with Section 1605.3 of the IBC must be
denominator. established using the following relationships:
ESR-2461 | Most Widely Accepted and Trusted Page 4 of 10
5.9 Since an ICC-ES acceptance criteria for evaluating data 5.14 Special inspections must be provided in accordance
to determine the performance of expansion anchors with Section 4.4 of this report.
subjected to fatigue or shock loading is unavailable at 5.15 Anchors are manufactured in Weilerbach, Germany,
this time, the use of these anchors under such under an approved quality-control program with
conditions is beyond the scope of this report. inspections by ICC-ES.
5.10 Anchors may be installed in regions of concrete where 6.0 EVIDENCE SUBMITTED
cracking has occurred or where analysis indicates
cracking may occur (ft > fr), subject to the conditions of Data complying with the ICC-ES Acceptance Criteria for
this report. Mechanical Anchors in Concrete and Masonry Elements
(AC193), dated October 2017 (Editorially revised April
5.11 Anchors may be used to resist short-term loading due 2018), for use in cracked and uncracked concrete and
to wind or seismic forces in locations designated as quality control documentation.
Seismic Design Categories A through F under the IBC
subject to the conditions of this report. 7.0 IDENTIFICATION
5.12 Where not otherwise prohibited in the applicable code, 7.1 Anchors are identified by packaging labeled with the
MKT SRS TZ anchors are permitted for use with fire- anchor name and size, the manufacturer’s name
resistance-rated construction provided that at least one (MKT) and contact information, the evaluation report
of the following conditions is fulfilled: number (ESR-2461). The MKT SRS TZ anchors have
the letters SRS-TZ embossed on the threaded end of
Anchors are used to resist wind or seismic forces the stud anchor body. Length identification is required
only. to be visible after installation (see Table 2).
Anchors that support a fire-resistance-rated 7.2 The report holder’s contact information is the following:
envelope or a fire-resistance-rated membrane are
protected by approved fire-resistance-rated MKT METALL-KUNSTSTOFF-TECHNIK GmbH &
materials, or have been evaluated for resistance to Co. KG
fire exposure in accordance with recognized AUF DEM IMMEL 2
standards. WEILERBACH, 67685
GERMANY
Anchors are used to support nonstructural +49 6374 9116-0
elements. www.mkt.de
5.13 Use of zinc-coated carbon-steel anchors is limited to info@mkt.de
dry, interior locations.
TABLE 2—LENGTH IDENTIFICATION SYSTEM (CARBON STEEL AND STAINLESS STEEL ANCHORS)
Length ID marking
C D E F G H I J K L M N O P Q R S T U V W
on stud
Length of anchor
21/2 3 31/2 4 41/2 5 51/2 6 61/2 7 71/2 8 81/2 9 91/2 10 11 12 13 14 15
min ≥ (in.)
Length of anchor
3 31/2 4 41/2 5 51/2 6 61/2 7 71/2 8 81/2 9 91/2 10 11 12 13 14 15 16
max < (in.)
sdesign cdesign Spacing s
cmin1; smin1
sdesign
h ≥ hmin cmin2; smin2
the appropriate value of must be determined in accordance with ACI 318-14 17.3.3(c) or ACI 318 D.4.3(c), as applicable. If the load combinations of ACI 318-11
Appendix C are used, the appropriate value of must be determined in accordance with ACI 318-11 D.4.4.
4
The tabulated value of cp applies when the load combinations of Section 1605.2.of the IBC, ACI 318-14 Section 5.3 or ACI 318 Section 9.2, as applicable, are used
and the requirements of ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c) for Condition B, as applicable, are satisfied. Condition B applies where supplementary
reinforcement is not provided or where pryout strength governs. For installations where complying supplementary reinforcement can be verified, the factors
described in ACI 318 17.3.3 or ACI 318-11 D.4.3 for Condition A, as applicable, are allowed. If the load combinations of ACI 318-11 Appendix C are used, the
appropriate value of must be determined in accordance with ACI 318-11 D.4.4.
TABLE 5—SRS TZ CARBON STEEL CHARACTERISTIC TENSION AND SHEAR STRENGTH DESIGN INFORMATION
FOR THE SOFFIT OF CONCRETE-FILLED PROFILE STEEL DECK ASSEMBLIES1,2,6
NOMINAL ANCHOR DIAMETER
CHARACTERISTIC SYMBOL UNITS 1 5
/2 inch /8 inch
7
Nominal Embedment Depth hnom in. 2 /8 33/4
1
Effective Embedment Depth hef in. 2 /2 31/4
Installation Torque Tinst ft-lbf 35 65
Pull-Out Resistance Cracked Concrete3 Np,deck,cr lbf 1,460 2,730
Pull-Out Resistance Uncracked Concrete4 Np,deck,uncr lbf 2,335 3,855
Steel Strength in Shear5 Vsa,deck lbf 2,785 4,410
Steel Strength in Shear, Seismic5 Vsa,deck,eq lbf 1,940 3,060
Strength Reduction factor 0.65 0.65
For Sl: 1 inch = 25.4mm, 1 ft-lbf = 1.356 N-m, 1 lbf = 4.45 N.
1
Installation must comply with Section 4.3 and Figure 4. Except as specifically noted, all installations must be into the lower flute of the deck.
2
Profile steel deck must comply with Figure 4 and have a minimum base steel thickness of 0.034 inch (0.9 mm). Steel must comply with ASTM A653 / A635M, with
minimum yield strength of 33 ksi (228 MPa).
3
The values must be used in accordance with Section 4.1.4 and 4.1.8.1 of this report.
4
The values must be used in accordance with Section 4.1.4 of this report.
5
The values must be used in accordance with Section 4.1.5 and 4.1.8.2 of this report.
6
The minimum anchor spacing along the flute must be the greater of 3.0hef or 1.5 times the flute width.
FIGURE 4—INSTALLATION IN THE SOFFIT OF CONCRETE OVER PROFILE STEEL DECK FLOOR AND ROOF ASSEMBLIES1
1
Anchors may be placed in the upper flute or lower flute of the steel deck profiles in accordance with Figure 3 provided the minimum hole clearance is satisfied.
Anchors in the lower flute of Figure 4 profiles may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may
be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied.
TABLE 6—EXAMPLE ALLOWABLE STRESS DESIGN VALUES FOR ILLUSTRATIVE PURPOSES 1,2,3,4,5,6,7,8
Nominal Anchor Effective
Embedment Allowable Tension Load,
Diameter, Embedment
Depth, hnom φNn /α
d0 Depth, hef
(in.) (pounds)
(in.) (in.)
1
/2 27/8 21/2 1,975
5
/8 33/4 31/4 3,085
For Sl: 1 inch = 25.4 mm, ft-lbf = 1.356 N-m, 1 lbf = 4.45 N.
1
Single anchor with static tension load only.
2
Concrete determined to remain uncracked for the life of the anchorage.
3
Load combination 5.3.1b of ACI 318-14 Section 5.3 or 9-2 of ACI 318-11 Section 9.2, as applicable, (no seismic loading) with sa = 0.75, cb = 0.65, and p = 0.65.
4
30% dead load and 70 % live load. Controlling load combination is 1.2D + 1.6L. Calculation of α based on weighted average: α = 0.3*1.2 + 0.7*1.6 = 1.48.
5
f′c = 2,500 psi (normal weight concrete).
6
ca1 = ca2 cac
7
h hmin
8
Values are for Condition B where supplementary reinforcement in accordance with ACI 318-14 17.3.3 or ACI 318-11 D.4.3, as applicable,is not provided.
ESR-2461 | Most Widely Accepted and Trusted Page 9 of 10
Determine if two 1/2 inch diameter SRS TZ carbon steel anchors with an
effective embedment depth hef = 21/2 inches installed 6 inches from center
to center and 3 inches from the edge of a 6 inch deep slab is adequate
for a service tension load of 2,000 lb. for wind and a reversible service
shear load of 400 lb. for wind (no seismic loads). The anchor group will
be in the tension zone, away from other anchors in f′c = 3,000 psi normal
– weight (cracked) concrete.
Vua = 1.6 W = 1.6 x 400 = 640 lb. Calculating for Nb and Ncbg:
0,5
3,000
Nsa = 0.75 x 2 x 9,080 = 13,620 lb. N pn, cr 2 1 . 0 x 2,810 6 ,156 lb. Table 3
2,500
4. Concrete Breakout Capacity under Tension Loading = 0.65 Table 3
17.4.2 (D.5.2)
Ncbg
A Nc
Ψec,NΨed,NΨc,NΨcp, NNb Eq.17.4.2.1b Npn, cr = 0.65 x 6,156 = 4,002 lb.
A Nco (Eq.(D-4))
where:
6. Check all Failure Modes under Tension Loading:
. Eq.17.4.2.2a
𝑁 𝑘 𝜆 𝑓ℎ 17.3.1.1
(Eq.(D-6))
(D.4.1.1)
Summary:
Eq.17.4.2.4
Ψec,N = 1.0 since eccentrically e’ N= 0
(Eq.(D-8))
Steel Capacity = 13,620 lb
Eq. 17.4.2.5b
C a,min Concrete Breakout Capacity = 3,643 lb. ← Controls
(Eq.(D-10))
Ψ ed,N 0.7 0.3 when C a,min 1.5h Pullout Capacity = 4,002 lb.
1.5h ef
by observation ca,min=3<1.5hef = 3.75
in.
(3) Φ Nn = 3,643 lb. as Concrete Breakout Capacity controls
Ψ ed, N 0.7 0.3 0.94
1.5(2.5) > Nua = 3,200 lb. - OK
Ψc,N = 1.0 assuming cracking at 17.4.2.6 Steel Capacity under Shear Loading:
service loads (ft > fr) (D.5.2.6) 7. 17.5.1 (D.6.1)
Calculating for ΦVsa:
Ψcp,N = 1.0 designed for cracked 17.4.2.7
Vsa = 2 x 7,420 = 14,840 lb.
concrete (D.5.2.7)
= 0.65
Table 4
Φ = 0.65
Vsa = 0.65 x 14,840 = 9,646 lb. Table 4
8. Concrete Breakout Capacity under Shear Loading: 10. Check all Failure Modes under Shear Loading:
17.3.1.1
17.5.2 (D.6.2)
(D.4.1.1)
17.5.2.1b
Summary:
(Eq. (D-31))
Steel Capacity = 9,645 lb.
where: Concrete Breakout Capacity = 2,272 lb. ← Controls
0.2
le Eq. 17.5.2.2a Pryout Capacity = 7,847 lb
Vb =7 da λ f'c ca1 1.5 (Eq. (D-33))
da
Vn = 2,272lb. as Concrete Breakout Capacity controls
Eq. 17.5.2.5
Ψec,V = 1.0 since eccentricity e’V = 0 > Vua= 640 lb. – OK
(Eq. (D-36))
Ψc,V = 1.0 assuming cracking at 17.5.2.7 If 0.2 Vn ≥ Vua then the full tension
service loads (ft > fr ) (D.6.2.7) 17.6.1
design strength is permitted.
(D.7.1)
By observation, this is not the case.
A Vc
calculating for
A Vc0 If 0.2 Nn ≥ Nua then the full shear
h = 6 > 1.5 ca1 = 1.5 x 3 = 4.5 in. 17.6.2
design strength is permitted.
(D.7.2)
AVc = (2(1.5ca1) + s1) 1.5ca1 Fig 17.5.2.1b
(Fig. By observation, this is not the case.
= (2 x 1.5 x 3 + 6) x 1.5 x 3
RD.6.2.1b)
= 67.5 in.2
Eq. 17.5.2.1c Therefore:
AVc0 = 4.5 (ca1)2 = 4.5 x 32 = 40.5 in.2 (Eq. (D-32))
Nua V
17.5.2.1 ua 1.2
A Vc 67.5 (D.6.2.1) ΦNn ΦVn
1.67
A Vc0 40.5 3,200 640
0.88 0.28 1.16 1.2 OK
3,643 2,272
calculating for Vb and Φ Vcbg
17.5.2.2
le = hef = 2.5 in. 12. Summary
(D.6.2.2)
ca1 = 3 in. Two 1/2 in. diameter SRS TZ at 2 1/2 in. effective
λ = 1.0 for normal weight concrete embedment depth are adequate to resist the applied
= 0.70 for Condition B Table 4 service tension and shear loads of 2,000 lb. and 400 lb.,
(no supplementary reinforcement provided) respectively.
0.2
2.5
Vb 7 0.5 1.0 x 3,000 (3) 1,944lb.
1.5
0.5
ΦVcbg 0.70 1.67 1.0 1.0 1.0 1,944 2,272lb.
Eq. 17.5.3.1a
Vcpg = kcp Ncbg
(Eq.(D-41))
where:
= 0.70 Table 4
17.5.3.1
kcp = 2.0 Table 4
(D.6.3.1)
Vcpg k cp Ncbg 2.0 5,605 11,210 lb. Eq. 17.5.3.1
(Eq. (D-41))