Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Franck-Hertz Experiment

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SUPPORT MANUAL FOR PRISM SPECTROMETER

In some of the optics experiment


experiments,, we will use a spectrometer. The spectrometer is an instrument
for studying the optical spectra.. Light coming from a source is usually dispersed into its various
constituent wavelengths by a dispersive element (prism or grating) and then the resulting
spectrum is studied. A schematic diagram of a prism spectrometer is shown in Fig. 1. It consists
of a collimator, a telescope, a circular prism table and a graduated circular scale along with two
verniers.. The collimator holds an aperture at one end that limits the light coming from the source
to a narrow rectangular slit. A lens at the other end focuse
focusess the image of the slit onto the face of
the prism. The telescope magnifi fies the light dispersed by the prism (the dispersive element for
your experiments) and focuses it onto the eyepiece. The angle between the collimator and
telescope are read off by the he circular scale. The detail description of each part of the
spectrometer is given below.

Telescope Collimator
Eye piece

Prism Leveling
Focus
Table screws
Knob Adjustable slit

Leveling Leveling Focus


screw screw Knob
Height adjustment
Verniers
screw for prism table
Telescope rotation:
Fine adjustment screw
Clamp screw

Circular
scale
Magnifying glass Base leveling screws
to read vernier

Prism table rotation:


Clamp screw
Fine adjustment screw

Fig. 1: Different parts of spectrometer

1
(i) Collimator (C): It consists of a horizontal tube with a converging achromatic lens at one end
of the tube and a vertical slit of adjustable width at the other end. The slit can be moved in or out
of the tube by a rack and pinion arrangement using the focus knob and its width can be adjusted
by turning the screw attached to it. The collimator is rigidly fixed to the main part of the
instrument and can be made exactly horizontal by adjusting the leveling screw provided below it.
When properly focused, the slit lies in the focal plane of the lens. Thus the collimator provides a
parallel beam of light.
(ii) Prism table (P): It is a small circular table and capable of rotation about a vertical axis. It is
provided with three leveling screws. On the surface of the prism table, a set of parallel,
equidistant lines parallel to the line joining two of the leveling screws, is ruled. Also, a series of
concentric circles with the centre of the table as their common centre is ruled on the surface. A
screw attached to the axis of the prism table fixes it with the two verniers and also keep it at a
desired height. These two verniers rotate with the table over a circular scale graduated in fraction
of a degree. The angle of rotation of the prism table can be recorded by these two verniers. A
clamp and a fine adjustment screw are provided for the rotation of the prism table. It should be
noted that a fine adjustment screw functions only after the corresponding fixing screw is
tightened.

(iii) Telescope (T): It is a small astronomical telescope with an achromatic doublet as the
objective and the Ramsden type eye-piece. The eye-piece is fitted with cross-wires and slides in
a tube which carries the cross-wires. The tube carrying the cross wires in turn, slides in another
tube which carries the objective. The distance between the objective and the cross-wires can be
adjusted by a rack and pinion arrangement using the focus knob. The Telescope can be made
exactly horizontal by the leveling screws. It can be rotated about the vertical axis of the
instrument and may be fixed at a given position by means of the clamp screw and slow motion
can be imparted to the telescope by the fine adjustment screw.

(iv) Circular Scale (C.S.): It is graduated in degrees and coaxial with the axis of rotation of the
prism table and the telescope. The circular scale is rigidly attached to the telescope and turned
with it. A separated circular plate mounted coaxially with the circular scale carries two verniers,
V1 and V2, 180° apart. When the prism table is clamped to the spindle of this circular plate, the
prism table and the verniers turn together. The whole instrument is supported on a base provided
with three leveling screws. One of these is situated below the collimator.

Adjustment of Spectrometer: The following essential adjustments are to be made step by step
in a spectrometer experiment: Leveling the apparatus means making (a) the axis of rotation of
the telescope vertical, (b) the axis of the telescope and that of the collimator horizontal, and (c)
the top of the prism table horizontal. The following operations are performed for the purpose.

(i) Leveling of telescope: Place a spirit level on the telescope tube making its axis parallel to that
of the telescope. Bring the air bubble of the spirit level halfway towards the centre by first
turning the two base leveling screws (i.e. leaving the base leveling screw below collimator) and
then turning the telescope leveling screw. Now rotate the telescope through 180° and adjust the
base and telescope leveling screws. Repeat the operations several times so that the bubble
remains at the centre for both positions of the telescope. Next place the telescope in the line with
the collimator and bring the air bubble of the spirit level at the centre by turning the base leveling

2
screw below the collimator. Again check the first adjustment for the previous orientations of
telescope. The axis of the rotation of the telescope has thus become vertical and the axis of the
telescope has become horizontal.

(ii) Leveling of collimator: Remove the spirit level from the telescope. Place it on the collimator
along its length. Bring the air bubble of the spirit level at the centre by adjusting the collimator
leveling screw provided below the collimator. This makes the axis of the collimator horizontal.

(iii) Leveling of the prism table: Place a spirit level at the centre of the prism table and parallel
to the line joining two of the leveling screws of the prism table. Bring the air bubble of the spirit
level at the centre by turning these two screws in the opposite directions. Now place the spirit
level perpendicular to the line joining the two screws and bring the bubble at the centre by
adjusting the third screw. This makes the top of the prism table horizontal.

(iv) Adjusting cross wires and focusing image


Rotate the telescope towards any illuminated background. On looking through the eye-piece, you
will probably find the cross-wires appear blurred. Move the eye-piece inwards or outwards until
the cross-wire appears distinct.
Place the telescope in line with the collimator. Look into the eye-piece without any
accommodation in the eyes. The image of the slit may appear blurred. Make the image very
sharp by turning the focusing knob of the telescope and of the collimator, if necessary. If the
image does not appear vertical, make it vertical by turning the slit in its own plane. Adjust the
width of the slit to get an image of desired intensity.

(v) Optical leveling of a prism: The leveling of a prism makes the refracting faces of the prism
vertical only when the bottom face of the prism, which is placed on the prism table, is
perpendicular to its three edges. But if the bottom face is not exactly perpendicular to the edges,
which is actually the case, the prism should be leveled by the optical method, as described
below:
(a) Illuminate the slit by sodium light and place the telescope with its axis making an angle of
about 90° with that of the collimator.
(b) Place the prism on the prism table with its vertex coinciding with that of the table and with
one of its faces (faces AB in Fig. 2) perpendicular to the line joining two of the leveling
screws of the prism table.
(c) Rotate the prism table till the light reflected from this face AB of the prism enters the
telescope. Look through the telescope and bring the image at the centre of the field of the
telescope by turning the two screws equally in the opposite directions.
(d) Next rotate the prism table till the light reflected from the other face AC of the prism enters
the telescope, and bring the image at the centre of the field by turning the third screw of the
prism table.
(vi) Focusing for Parallel rays by Schuster’s method: This is the best method of focusing the
telescope and the collimator for parallel rays within the space available in the dark room. In
order to focus the telescope parallel light rays are required and this in turn requires a properly
adjusted collimator. For this reason the adjustment of the telescope and the collimator are usually
done together.

3
Schuster's method is based on the fact that the
effect of the prism on the divergence of the beam
is different on opposite sides of this minimum
deviation position (see Fig. 2). The emergent
beam will be less divergent (or more divergent)
than the incident beam as the angle of incidence
is increased (or decreased) from the minimum
deviation value (i.e. as the apex A in Fig.2 is
rotated towards, or away from, the telescope).
This property of the prism can be used to obtain
an accurately collimated beam. The method is Fig. 2: Minimum deviation of light ray
explained below:
(a) Place the prism on the spectrometer table as shown in Fig.2.
(b) For your prism the angle of minimum deviation is around 50° so set the telescope at an angle
a few degrees greater than this (~55°).
(c) Illuminate the slit of the spectrometer with light from a sodium lamp. Rotate the prism table
and observe the images of the slit through the telescope as it passes through the minimum
deviation position.
(d) Lock the telescope at an angle a few degrees greater than this position.
(e) Turn the prism table away from its minimum deviation position so that apex A moves
towards the telescope and a spectral line is brought into the centre of the field of view of the
telescope. Adjust the focus of the telescope until this line image is as sharp as possible.
(f) Turn the prism table to the other side of the minimum deviation position until the same
spectral line is again at the centre of the telescopes field of view. Now adjust the focus of the
collimator until a sharp image is once more obtained.
(g) Repeat this process until no further adjustment is required. If the same line image is sharply
focused when viewed on either side of the minimum deviation position then the light beam
through the prism is properly collimated.

You might also like