Power Ranges: 23.7 – 48.5 kW; 31.8 – 65.0 bhp


Full Load Speed Range: 1200 – 2500r/min

Engine Characteristics: Typical Engine Features


• Lister Petter four cylinder, indirect injection.
• Naturally aspirated.
• Water cooled.
• Diesel fuelled.
• Anti-clockwise rotation, looking on the flywheel end.
• Standard oil and fuel filters.
• Heavy duty air cleaner.
• 12 volt electric starting with a 55 Amp alternator.

Design Features:
• Designed for continuous operation in ambients up to
52°C (122°F)
• Tropical radiator with a pusher fan and full guarding.
• Gear driven positive displacement type lubricating oil
pump.
• 250 hour service intervals. Standard Equipment and Options
• Self-vent fuel system with a rotary fuel injection pump
and integrated fuel control solenoid. Standard Equipment:
• Combustion chamber glow plugs. • Flywheel with ring gear.
• Flywheel housing with SAE3 flange.
• Inlet and exhaust manifolds.
• Spin-on lubricating oil filter.
• Fuel filter/agglomerator.
• Electric fuel lift pump.
Warranty • Low oil pressure switch.
• Operators Handbook.
• Standard – two years from manufacture.
• Optional – five years from the date of sale (conditions
apply).

Optional Items:
• A comprehensive range of options allows the
customer to select a specification which matches
Emission Compliant their requirement.
• Five year warranty from the date of sale (conditions
• EPA Tier 2 compliant – 1800rmin fixed speed. apply).
Power and Torque Performance to ISO 3046
r/min 1200 1500 1800 2000 2200 2500

Fixed speed kW - 28.7 33.2 - - -


continuous hp - 38.5 44.5 - - -
Fixed speed kW - 31.6 36.5 - - -
overload power hp - 42.3 48.9 - - -

Variable speed kW 23.7 30.2 35.7 39.0 41.9 46.3


continuous hp 31.4 40.5 47.9 52.3 56.2 62.1

Variable speed kW 25.0 31.6 36.9 40.3 43.6 48.5


overload power hp 33.5 42.4 49.5 54.0 58.4 65.0

Torque – vari- Nm 188.6 192.3 189.4 186.2 181.9 176.9


able speed con- lbf ft 139.1 141.8 139.7 137.4 134.2 130.5

Fuel Consumption – full load, continuous power


r/min 1200 1500 1800 2000 2200 2500

g/kW h 230 235 242 242 240 245


Technical Data
Type of fuel injection Indirect
Aspiration Natural
Direction of rotation – looking on flywheel end Anti-clockwise
mm 94.0
Nominal cylinder bore
in 3.7
mm 120.0
Stroke
in 4.7
litre 3.33
Total cylinder capacity 3
in 203.3
Compression ratio 22:1
Firing order (number 1 cylinder is at the gear end) 1-3-4-2
Minimum idling speed r/min 700
Minimum full load speed r/min 1200
Number of flywheel ring gear teeth 122
Number of starter motor pinion gear teeth 10
Maximum intermittent end thrust N 2160.0
- forwards towards the flywheel lbf 485.0
N 1080.0
- rearwards away from the flywheel
lbf 242.5
Maximum continuous end thrust N 1080.0
- forwards towards the flywheel lbf 242.5
N 540.0
- rearwards away from the flywheel
lbf 121.3
Nm 20.0
Maximum inline power take off from the crankshaft pulley
lbf ft 44.1
Auxiliary hydraulic power take off drive ratio 1:1
Nm 125.0
Auxiliary hydraulic power take off maximum permissible torque
lbf ft 276.0

Maximum permissible intake restriction at full rated speed and mbar 63.5
load in H2O 25.0
mbar 68.0
Maximum permissible exhaust back pressure
in H2O 27.2
Approximate Dimensions and Weight Rating Definitions (ISO 3046)
1. Fixed Speed Power - continuous speed (ICN)
kg 245 The power in kW which the engine is capable of
Dry weight delivering continuously at the stated crankshaft speed,
under conditions of 100 kPa barometric pressure, 30%
lb 539 relative humidity and 25°C air inlet temperature,
provided that the engine is overhauled and maintained
mm 781 in good operating condition and that fuel to BS EN 590
Length (A) Class A1 or A2, and lubricating oils to the correct
in 30.7 performance specification and viscosity classification as
recommended by Lister Petter Limited, are used.
mm 570 2. Fixed Speed Powers - overload power (ICXN)
Width (B) The maximum power in kW which the engine is capable
in 22.4 of delivering intermittently at the stated crankshaft
speed for a period not exceeding one hour in any period
mm 712 of twelve hours continuous running, immediately after
working at the continuous power, uner the conditions
Height (C) specified in (1) above.
in 28.0
3. Variable Speed - fuel stop power, continuous power (IFN)
The maximum power in kW which an engine is capable
of delivering continuously at stated crankshaft speed,
under the conditions as specified in item 1, with the fuel
limited so that the fuel stop power cannot be exceeded.

4. Variable Speed - fuel stop power, intermittent (IOFN)


The maximum power in kW which an engine is capable
of delivering intermittently at the stated crankshaft
speed, for a period not exceeding 1 hour in any period
of 12 hours continuous running immediately after
running at the Continuous Fuel Stop Power rating.

5. De-rating
For non-standard site conditions, reference should be
made to relevant BS, ISO and DIN standards.

Notes:
1. The overload capability applies to a fully run-in engine.
This is normally attained after a running period of about 50
hours .
2. Power ratings measured at the flywheel and fuel
consumptions, apply to a fully run-in, non derated engine
without a radiator and fan fitted, and without power
absorbing accessories or transmission equipment.

Distributors Address

UK
Lister Petter Limited, Dursley, Gloucestershire GL11 4HS England
Tel: +44 (0)1453 544141; Fax: +44 (0)1453 546732; E-mail: sales@lister-petter.co.uk http://www.lister-petter.co.uk
USA
Lister Petter Americas Inc. 815 E. 56 Highway, Olathe, Kansas 66061 USA
Tel: +1 913 764-3512; Fax: +1 913 764-5493; E-mail: info@lister-petter.com; http://www.lister-petter.com
FRANCE
Lister Petter France, 17 Avenue de L'escouvrier, Zone d'Activites, 95842 Sarcelles, Cedex France
Tel: +33 (0)1 39330420; Fax: +33 (0)1 34195760; E-mail: commercial@lister-petter-france.fr
INDIA
Lister Petter Private Limited, 102 Beaver Gradeur, Baner, Pune 411045 India
Tel: +91 20 729 3284; Fax: +91 20 729 3287
CHINA
Lister Petter China, Jinan Fugiang Power Co. Ltd. 159 Ying Xiong Shan Street, Jinan PC 250002. P.R. China
Tel: +86 531 271 0148; Fax: +86 531 297 1113

We have made efforts to ensure that the information is accurate, but reserve the right to amend specifications and information without notice and without obligation or
liability
P027-08496 Issue 11: May 2006 © Copyright Lister Petter Limited

You might also like