IndustrialNet™ Category 6 S/FTP Copper Cable

S P E C I F I CAT I O N S H E E T

specifications
Category 6 S/FTP copper cable shall meet or exceed the IEC 61156-6 and IndustrialNet ™ Category 6 S/FTP
ANSI/TIA-568-C.2 Category 6 standards up to 80 meters. The stranded Copper Cable
copper conductors shall be 24/7 AWG with foamed polyethylene (PE)
insulation. The copper conductors shall be twisted in pairs. Each of the Flame retardant,
four pairs shall be surrounded by an overall metallic foil. All four pairs shall halogen-free
then be surrounded by an overall braided shield and covered with a 4-pair: ISX6004AYL-LED
polyurethane (PUR) jacket. The jacket shall be oil, ozone, and abrasion
resistant for enhanced chemical resistance and mechanical performance.
Category 6A RJ45 Field
The jacket shall be flame retardant and halogen-free for industrial Ethernet Terminable Plug
applications. The cable shall support high flex and torsion applications. Field terminable
plug: FPS6X88MTG
IndustrialNet Category 5e Shielded

technical information 600 V-Rated Patch Cords


Electrical performance: Certified component performance up to 80 meters and exceeds the CM/CMX: ISTPHCH1MTL**
requirements IEC 61156-6 and ANSI/TIA-568-C.2 Category 6 at swept
frequencies up to 250 MHz IndustrialNet M12 D-Code to

RJ45 Panel Mount Adapter


Standard compliances: Flexure IEC 61935-2
Flex Life Test: 1 million cycles at 10x cable diameter; 10 million cycles at Panel mount
20x cable diameter adapter: ICAM12DRJS
Torsion Life Test: 3 million cycles, 360°
Ozone resistance VDE 0805 Mini-Com Modular Patch Panel
®

Oil resistance EN 60811-2-1 (7 days x 24hrs/90°C) 8-port, unshielded: CDPP8RG


Conductors/insulators: Four pairs of 24/7 AWG stranded copper insulated with foamed polyethylene 8-port, shielded: CDPP8RG-S
Insulation diameter: 1.38 – 1.48mm (0.054 – 0.058 in.) DIN Rail Adapter
Flame rating: Flame retardant, halogen-free – IEC 60332-1-2, IEC 60754-1; EN50575: 1-port: CADIN1IG***
Euroclass Eca
1-port, shielded: CADIN1IG-S***
Installation tension: 80 N (18 lbf) maximum
**For other lengths, change the length
Temperature rating: -40°C to 80°C (-40°F to 167°F) during transport, installation, and operation designation (1M) of the part number to the
desired length (0.3M, 0.6M, 2M, 3M, 5M, or
Cable jacket: Polyurethane (PUR), oil, ozone, and abrasion resistant 10M); to designate color, replace TL (Teal)
Cable diameter: 8.0mm (0.315 in.) nominal suffix with BL (Black), RD (Red), or YL (Yellow).
For example, the part number for a 2-meter
Cable weight: 30 kg/500m (66 lbs./1640 ft.) teal patch cord is ISTPHCH2MTL.
***For standard colors other than International Gray,
Packaging: Packaged 500 meters (1640 feet) on a reel Package tested to ISTA Procedure 1A
replace IG in part number with BL (Black).

key features and benefits


Third party tested Cable has been tested by an independent laboratory and complies with the
electrical standard requirements of IEC 61156-6 and ANSI/TIA-568-C.2
Category 6 standards
Reliability Shielded S/FTP cable construction protects against environmental elements
that can cause electrical performance failures; stranded conductors for
standard flex applications and ease of installation; cable jacket shall be
oil, ozone, and abrasion resistant for enhanced chemical resistance and
mechanical performance
Descending length Easy identification of remaining cable reduces installation time and cable scrap
cable markings
Packaged on a reel Ensures proper performance and provides quick installation

applications
IndustrialNet™ Category 6 S/FTP Copper Cable Key applications include:
provides reliability and high performance as an • 10BASE-T (Ethernet)
integral component of the end-to-end solution • 100BASE-T (Fast Ethernet)
for industrial Ethernet and Ethernet/IP based
• 1000BASE-T (Gigabit Ethernet)
communications networks. The 4-pair high
performance cable ensures highest availability • Industrial Ethernet
in conditions seen in industrial environments. • Ethernet/IP
The cable incorporates a durable PUR jacket • Downlinks from control panel to the machine area
for use in installations requiring cable with a • Uplinks featuring gigabit data transmission from
halogen-free rating. the control panel to the consolidation point

www. p a n d u i t .c om
IndustrialNet™ Category 6 S/FTP Copper Cable

additional specifications
Mechanical Test
Ultimate Breaking Strength >400 N (90 lbf)
Minimum Bend Radius 8x cable diameter
Electrical Test
Nominal Velocity of Propagation (NVP) 74%
Operating Voltage, maximum 80 V

cable construction

Stranded Conductor Wire

Conductor Insulator

Cable Shield Screen

Twisted Pair
(Foil) Shield

Jacket

WORLDWIDE SUBSIDIARIES AND SALES OFFICES

PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD.
Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia
Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020

For a copy of Panduit product warranties, log on to www.panduit.com/warranty

For more information ©2021 Panduit Corp.


ALL RIGHTS RESERVED.
Visit us at www.panduit.com Printed in the U.S.A.
Contact Customer Service by email: cs@panduit.com COSP342--WW-ENG
or by phone: 800.777.3300 4/2021

You might also like