Untitled
Untitled
Untitled
12000
6000 6000
BURNT LIME STORAGE BIN
EMERGENCY SHOWER AND EYEWASH
PLANT NORTH
0390-BNS-031
A 3284 5527 0390-ZPS-002
PLANT NORTH
25800-220-P1-0390-01207
48, H
49° RT
A 48, H NO EL. 4332.000 A
49° RT AL T.O.C. ACCESS SEPARATING TANK
NO RE
3310
LIME BIN VENT FILTER 0390-MLT-006-04
AL
RE 0390-DCB-039 LIME SLAKING MILL DISCHARGE TANK
5730 10850 8150
6000
LIME BIN JIB CRANE 0390-TKS-241
0390-CNJ-001 EL. 4332.000 EMERGENCY SHOWER AND EYEWASH
CL BIN
LOW POINT 0390-ZPS-018
BURNT LIME STORAGE BIN EMERGENCY SHOWER AND EYEWASH
11250
LIME BIN VENT FILTER 0390-BNS-031 0390-ZPS-002 EMERGENCY SHOWER AND EYEWASH
0390-DCB-040 0390-ZPS-020
LIME SLAKING MILL SCRUBBER FAN LIME HOLDING TANK FEED PUMP
7940
0390-MLT-006-09 0390-PPS-241
LIME SLAKING MILL EL. 4332.600
N: 7678880.773
5250
0390-MLT-006 HIGH POINT EMERGENCY SHOWER AND EYEWASH
E: 517162.663
0390-ZPS-019
EMERGENCY SHOWER AND EYEWASH
EMERGENCY SHOWER AND EYEWASH
0390-ZPS-018
150
0390-ZPS-020
LIME HOLDING TANK FEED PUMP
B TRANSPORTER FOR SCREW 0390-PPS-241 B
150
0390-MLT-006-02 EL. 4332.000
3460
PLATF. LEVEL 1100
LIME SLAKER BALL STORAGE BIN SLOPE=10%
1390
0390-MLT-006-13 ACCESS
9350
2410
9350
EL. 4331.450
0390-CNH-050 PLATF. LEVEL BALL STORAGE BIN
LOW POINT
8860
LIME PLANT SUMP PUMP
0390-ZPS-004 0390-PPR-236
731
ACCESS EL. 4332.000
SUMP PUMP SUPPORT 908 T.O.C.
150
0390-STU-201
LIME PLANT SUMP PUMP
150
1390
0390-PPR-236 LIME HOLDING TANK FEED PUMP
0390-PPS-242
ACCESS
C C
2410
LIME HOLDING TANK
7100
7100
0390-TKF-244 SLO
22000
PE = EMERGENCY SHOWER AND EYEWASH
2.1%
0390-ZPS-001
ACCESS EMERGENCY SHOWER AND EYEWASH EL. 4331.450
SLAKER RECIRCULATION PUMP
12350
0390-ZPS-019 LOW POINT
0390-MLT-006-05
B
propiedad de Bechtel que no debe ser usada, divulgada o reproducida de ninguna forma por ninguna persona o entidad distinta a
HIGH POINT
LIME HOLDING TANK FEED PUMP
19100
Confidencial. © 2019 Bechtel Chile Ltda. Este documento, preparado bajo el Contrato 25800 celebrado entre
5250
0390-PPS-242
LIME PLANT PROCESS WATER PUMP
Bechtel o Compañia Minera Teck Quebrada Blanca S.A. sin el permiso previo y por escrito de Bechtel
8240
EMERGENCY SHOWER AND EYEWASH 0390-PPC-259
5930
0390-ZPS-001
SL
0390-ZPS-003 0390-PPC-260
OP
CL TANK D
CL TANK
E=
CL TANK CL TANK
2.
LIME HOLDING TANK
1%
0390-TKF-244
6750
LIME HOLDING TANK AGITATOR
0390-AGA-243
3758
N: 7678858.068 LIME HOLDING TANK
E: 517171.946 0390-TKF-243
8220
10005
EL. 4332.000
EMERGENCY SHOWER AND EYEWASH HIGH POINT
2907 2324
Todos los derechos reservados
0390-ZPS-005
LIME DISTRIBUTOR BOX 1575 14400 4613
EL. 4332.000
CL DISCHARGE 0390-DIS-300 HIGH POINT KEY PLAN
5300 20590 2260 S/E
CL DISCHARGE
N
76
E
79
28150
00
LIME HOLDING TANK AGITATOR
0
N:
0390-AGA-244 00
76
65
51
78
0390-PPS-244
8.
8
between Bechtel Chile Ltda. and Compañia Minera Teck Quebrada Blanca S.A. , contains information
51
.4
81
CL SUCTION
CL SUCTION
N
7200 7200
76
0390-PPS-244
78
50
0
Bechtel's prior written permission. All rights reserved
VP1 8013-CC-2027
D
25800-220-P1-0390-01207
PLAN 2 0 2 4 6 8 10 15M
SCALE: 1:150 mm 00 00
70 75
1:150 51 51
E E
G
25800_D.dgn - 863,3 mm x 558,8 mm
BECHTEL
ENG. MANAGER: BY: P. CHAPARRO P. CHAPARRO 20-NOV-2017
REAGENT PLANT
NEDM. MUÑOZ
TECK
A. CORBALAN CHECKED EGS:
SIG
BY: J. QUEVEDO 23-NOV-2017
3-.COORDINATES SYSTEM U.T.M WGS 84 HUSO 19 S PROJ. MANAGER:
K. HROZA PROJ. ENGINEER: P. MOYA 28-NOV-2017
GENERAL ARRANGEMENT
1 16-DEC-2019 GENERAL REVIEW F.P. L.L. M.M. PM/EG LIME PREPARATION SYSTEM VENDOR GENERAL ARRANGEMENT 25500-220-V2A-MWC0-00022 2-.ELEVATIONS AND COORDINATES ARE IN METERS ENG. MANAGER: E. GOMEZ 29-NOV-2017 LIME PLANT - PLAN AND FLOOR PLAN
0 21-JAN-2019 ISSUED FOR CONSTRUCTION A.A. C.R. M.M PM/EG CONCENTRATOR SITE PLAN 25800-220-P1-0300-00001 1-.DIMENSIONS ARE IN MILLIMETERS BECHTEL DRAWING N°: TECK DRAWING N°: REV.