MFM-REF

https://www.mfmref.com
info@mfmref.com
BITZER Software v6.9.1 rev2074 28.02.2019 / All data subject to change. 5 / 13

Technical Data: 4TES-9Y


Dimensions and Connections

Technical Data
Technical Data
Displacement (1450 RPM 50Hz) 41,33 m3/h
Displacement (1750 RPM 60Hz) 49,88 m3/h
No. of cylinder x bore x stroke 4 x 60 mm x 42 mm
Weight 134 kg
Max. pressure (LP/HP) 19 / 32 bar
Connection suction line 35 mm - 1 3/8''
Connection discharge line 28 mm - 1 1/8''
Oil type R134a/R407C/R404A/R507A/R407A/R407F BSE32(Standard) / R134a tc>70°C: BSE55 (Option)
Oil type R22 (R12/R502) B5.2(Option)
Motor data
Motor version 2
Motor voltage (more on request) 380-420V PW-3-50Hz
Max operating current 19.9 A
Winding ratio 50/50
Starting current (Rotor locked) 49.0 A Y / 81.0 A YY
Max. Power input 13,0 kW
Extent of delivery (Standard)
Motor protection SE-B1, CM-RC-01(Option)
Enclosure class IP66
Vibration dampers Standard
Oil charge 2,60 dm³
Available Options
Discharge gas temperature sensor Option
Start unloading Option
Capacity control 100-50% (Option)
Capacity Control - infinite 100-10% (Option)
Additional fan Option
Refrigerant Injection (RI) Option
Oil service valve Option
Crankcase heater 0..140 W PTC (Option)
Oil level monitoring OLC-K1 (Option)
Sound measurement
Sound power level (-10°C / 45°C) 74,3 dB(A) @50Hz
Sound power level (-35°C / 40°C) 78,9 dB(A) @50Hz
Sound pressure level @ 1m (-10°C / 45°C) 66,3 dB(A) @50Hz
Sound pressure level @ 1m (-35°C / 40°C) 70,9 dB(A) @50Hz
Sound power level (-10°C / 45°C) R134a 72,3 dB(A) @50Hz
Sound pressure level @ 1m (-10°C / 45°C) R134a 64,3 dB(A) @50Hz
MFM-REF
https://www.mfmref.com
info@mfmref.com
BITZER Software v6.9.1 rev2074 28.02.2019 / All data subject to change. 6 / 13
Semi-hermetic Reciprocating Compressors

Semi-hermetic Reciprocating Compressors


Motor 1 = e.g. 4TES-12 with 12 "HP", primary for air-conditioning (e.g. R22,R407C) and air-conditioning with R134a at high
ambient temperatures.
Motor 2 = e.g. 4TES-9 with 8 "HP", universal Motor for medium and low temperature application (e.g. R404A, R507A, R407A,
R407F) and air-conditioning with R134a
Motor 3 = e.g. 4TES-8, for medium temperature applications and R134a
For more information concerning the application range use the "Limits" button.

Operation modes 4VES-7 to 6FE-44 and 44JE-30 to 66FE-88 with R407F/R407A/R22


CIC = liquid injection with low temperature application, suction gas cooled motor.

ASERCOM certified performance data


The Association of European Refrigeration Component Manufacturers has implemented a procedure of certifying performance
data. The high standard of these certifications is assured by:
* plausibility tests of the data performed by experts.
* regular measurements at independent institutes.
These high efforts result in the fact that only a limited number of compressors can be submitted. Due to this not all BITZER
compresors are certified until now. Performance data of compressors which fulfil the strict requirements may carry the label
"ASERCOM certified". In this software you will find the label at the respective compressors on the right side below the field
"result" or in the print out of the performance data. All certified compressors and further information are listed on the homepage
of ASERCOM.

Condensing capacity
The condensing capacity can be calculated with or without heat rejection. This option can be set in the menu
Program ⟹ Options. The heat rejection is constantly 5 % of the power consumption. The condensing capacity is to be found in
the line Condensing cap. (with HR) resp. Condensing capacity.

Data for sound emission


Data based on 50 HZ apllication (IP-units 60 Hz) and R404A if not declared.
Sound pressure level: values based on free field area conditions with hemisperhical sound emission in 1 meter distance.

General remarks regarding sound data


Listed sound data were measured under testing conditions in our laboratory. For this purpose the free-standing test sample is
mounted on a solid foundation plate and the pipework is connected vibration-free to the largest extend possible. Suction and
discharge lines are fixed in a flexible configuration, such that a transmission of vibrations to the environment can be largely
excluded. In real installations considerable differences might be observed, compared to the measurements in the laboratory.
The airborne sound emitted by the compressor can be reflected from surfaces of the system and this may increase the airborne
sound level measured close to the compressor. Vibrations caused by the compressor are also transferred to the system by the
compressor feet and piping depending on the damping ratio of the fixings. Thus, the vibrations can induce other components to
such an extent that these components contribute to an increase in airborne sound emission. If required, the transfer of
vibrations to the system can be minimized by suitable fixing and damping elements.
Legend of connection positions according to "Dimensions":
1 High pressure connection (HP)
2 Connection for discharge gas temperature sensor (HP) (for 4VE(S)-6Y .. 4NE(S)-20(Y) connection for CIC sensor as
alternative)
3 Low pressure connection (LP)
4 CIC system: injection nozzle (LP)
4b Connection for CIC sensor
4c Connection for CIC sensor (MP / operation with liquid subcooler)
5 Oil fill plug
6 Oil drain
7 Oil filter (magnetic screw)
8 Oil return (oil separator)
8* Oil return with NH3 and insoluble oil
9 Connection for oil and gas equalization (parallel operation)
9a Connection for gas equalization (parallel operation)
9b Connection for oil equalization (parallel operation)
10 Oil heater connection
11 Oil pressure connection +
12 Oil pressure connection –
13 Cooling water connection
14 Intermediate pressure connection (MP)
15 Liquid injection (operation without liquid subcooler and with thermostatic expansion valve)
16 Connection for oil monitoring (opto-electrical oil monitoring "OLC-K1" or differential oil pressure switch "Delta-PII")
MFM-REF
https://www.mfmref.com
info@mfmref.com
BITZER Software v6.9.1 rev2074 28.02.2019 / All data subject to change. 7 / 13

17 Refrigerant inlet at liquid subcooler


18 Referigerant outlet at liquid subcooler
19 Clamp space
20 Terminal plate
21 Maintenance connection for oil valve
22 Pressure relief valve to the atmosphere (discharge side)
23 Pressure relief valve to the atmosphere (suction side)
24 IQ MODULE
SL Suction gas line
DL Discharge gas line
Dimensions can show tolerances according to EN ISO 13920-B.
MFM-REF
https://www.mfmref.com
info@mfmref.com
BITZER Software v6.9.1 rev2074 28.02.2019 / All data subject to change. 8 / 13

Selection: Horizontal receivers


Input Values
Common Yes
Auto
Operating point Auto

Operating Points
A
to [°C] -10
tc [°C] 45

Result
Compressor: 4TES-9Y
Recommendation: F252H
Selection F252H
Recommended operating point: A
Selected operating point: A
Receiver volume 25,0 dm³
max refrigerant charge 27,6 kg
receiver load 75,4 %
Receiver unit indivi. components
lower fixing rails 327301-05
upper fixing rails 327301-24
upper fixing plate 320366-02
#1: Receiver selection for compact systems without condensing pressure control. Precise calculation only via refrigerant charge (see notes).