STG Perkins 135kva

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

STANDARD SPECIFICATIONS ENGINE / TECHNICAL DATA

135 KVA
1. ENGINE Perkins
Engine Make
Perkins four stroke heavy duty high 1106A-70TG1
Engine Model
performance industrial type diesel
engine. Governing class ISO 8528-5 G2
Number of Cylinders 6
2. ENGINE FILTRATION SYSTEM Cylinder Arrangement Vertical in line
• Cartridge type dr Bore and Strokemm 105 x 135
• Displacement / Cubic Capacity litres 7.01
• o
ave replaceable Induction System Turbocharged,air to air aftercooled
elements. Cycle
Combustion System
4 stroke
Direct Injection
POWERED
3. COOLING RADIATOR
Radiator and cooling fan, complete with safety
Compression Ratio
Rotation
18.2:1 BY:
guards, designed to cool the engine at high
ambient temperatures (consult your dealer for Cooling System Water - cooled
de-ration factors).
Frequency and Engine Speed 50Hz & 1500rpm 60Hz & 1800rpm

4. EXHAUST SYSTEM Prime Standby Prime Standby


Gross Engine Power kW (hp) 123.7(166) 136.9(184) 140.5(188) 155.4(208)
Silencer noise reduction level 12 (dB) 15.9 - -
Fuel Consumption @ 50% load L/hr 18.0
Maximum allowable back pressure 6 (kPa) -
@ 75% load L/hr 22.7 - 26.5
@ 100% load L/hr 30.2 33.8 35.2 38.8
5. CIRCUIT BREAKER TYPE 18.0 18.0 18.0 18.0
Total Lubrication System Capacity litres
3 pole MCB / MCCB (supplied disconnected
and without cables) Total Coolant Capacity (inc. radiator)litres 21.0 21.0 21.0 21.0

CONTROL PANEL Exhaust Temperature:°C 576 576 576 576


Radiator Cooling Air Flow (Min): m 3 /sec 3.81 4.1 3.9 4.3
Make Deep Sea Combustion Air Flow: m3/min 7.64 8.1 11.0 11.5
Exhaust Gas Flow:m3/min 20.8 22.7 27.2 29.1
Model DSE6110/20
Fuel Tank Capacity:litres 275 275 275 275

The DSE6110 i s an Auto Start Control Module


and The DSE6120 is an auto mains(utility)
Failure Control Module for single gen-set applications.
Both modules have been designed to work with DIMENSIONS AND WEIGHT*
electronic engines providing advance engine
monitoringand protection features. Lengthmm Widthmm Heightmm Weight* kg (wet)
2400 850 1300 1240
• Transfer between mains(utility) and
ALTERNATOR DATA
generator power(DSE6120 only) * For skid mounted genset without enclosure wet weight = with lube oil and coolant
• Generator frequency Make Stamford
• Underspeed, Overspeed Model UCI 274 E
• Generator volts (L-L, L-N) KVA 140
• Generator current KW 112
Output Ratings Prime Standby No. of bearings
• Engine oil pressure 1
• Engine coolant temperature 380-415 V, 3 ph, 50 Hz, 1500 rpm 135.01 KVA 148.51 KVA Insulation class H
Total Harmonic Content in linear load <5% , at no load < 1.5%
• Fuel level (Warning or shutdown) 108.01 KW 118.81 KW
• Hours run counter Winding Leads 12
480 V, 3 ph, 60 Hz, 1800 rpm 135.60 KVA 149.16 KVA Ingress Protection IP23
• Battery volts
108.48 KW 119.33 KW Excitation System Self-Excited
• Fail to start/stop
Winding Pitch 2/3
• Emergency stop
Applicable Voltages: 220/127 V at 60 Hz only (Consult your dealer for more details) AVR Model AS440 / SX460
• Failed to reach loading voltage/frequency
Ratings at 0.8 Power Factor Overspeed 2250 mn-1
• Charge fail
Voltage Regulation ±1%
• Loss of magnetic pick-up signal
Short Circuit Capacity -
• Low DC voltage
• CAN diagnostics and CAN fail/error
The image shown above might not be the final product
STANDARD SPECIFICATIONS

6. FUEL SYSTEM AVAILABLE OPTIONS & ACCESSORIES


RATINGS DEFINITION
On Generating Sets up to 2000 KVA, the We offer a range of optional features and accessories to tailor our
base frame design can be incorporated with Prime Power generating sets to meet your power needs.
an integral fuel tankwith a capacity of
approx. 8 hours running at Full Load. The These ratings are applicable for supplying continuous electrical
power (at variable load) in lieu of 3500.0 1200.0
breather fuel feed and return lines to the
Engine and drain plug. commercially purchased power. 10% overload power is available
for 1 hour in 12 hours continuous
7. ALTERNATOR operation.
7.1 INSULATION SYSTEM
Standby Power
• The insulation system is Class H. 1720.0
• All windings are impregnated in either a triple These ratings are applicable for supplying continuous electrical
dipthermosetting liquid, oil and acid resisting
polyester varnish or vacuum pressure
power (at variable load) in the event of a
impregnated with a special utility power failure. No overload is permitted on these ratings.
polyester resin.
STANDARD REFERENCE CONDITIONS
• Heavy coat of antitracking varnish additional
protection against moisture. Output ratings are presented at 25°C air inlet temperature,
barometric pressure 100 kPa, relative humidity 30%. This
7.2 AUTOMATIC VOLTAGE REGULATOR (AVR)
generating set is designed to operate at high ambient
The fully sealed Automatic Voltage Regulator
maintains the Voltage Regulation at ±0.5%. temperatures (up to 55°C), humidity (up to 99%) and 2400
Nominal adjustment by means of a trim pot altitudes. De-ration may apply,please consult your dealer for
incorporated on the AVR.

7.3 MOTOR STARTING an overload capacity


STAUNCH Generators are assembled Some of the
equivalent to 300% of the Full Load impedance at
zero Power Factor can be sustained for 10 l Genset models. in
seconds. tion in this 1300
document is substantially correct at time of printing and
8. MOUNTING ARRANGEMENT may be altered subsequently.

8.1 BASE FRAME Generating Set pictured may include optional accessories.
The complete Generating Set is mounted as a
whole on a heavy duty fabricated steel
STAUNCH
Baseframe. 11. DOCUMENTATIONS a set of Operation & Maintenance 850
manual, Circuit wiring diagrams and Commissioning / Fault
8.2 COUPLINGThe Engine and Alternator are ny the Generator.

12. QUALITY STANDARDS The equipment meets the


ACCESSORIES
Alternator rotor.
following standards: BS4999, BS5000, BS5514 IEC 60034,
8.3 ANTI-VIBRATION MOUNTING PADS anti- VDE0530, NEMA MG 1.22 and ISO 8528. • switches
Vibration • Load banks
Alternator feet and the Baseframe thus ensuring 13. WARRANTY All of the Generating Sets are covered • Auxiliary fuel tanks
complete vibration isolation of the rotating under a warranty policy for a period of 12 months. Warranty
assembly.The Fan & Fan Drive along with the of the equipment is in line with manufacturers warranty
• Manual & automatic
Battery Charging
terms & conditions. • Genuine spare partstransfer
8.4 SAFETY GUARDS The Fan & Fan Drive along
with the Battery Charging Alternator are Safety (check warranty statement for more details, as it may vary
Guard protected for personal protection. for different countries)In line with continuous product OPTIONS
development, we reserve the right to change s ations
9. FACTORY TESTS without notice. • Water jacket heater
• The Generating set is load tested before • A variety of generating set
dispatch • Additional protection alarms
• All protective devices control functions and site For further information on all of the standard
load conditions are simulated. The generator and and optional features accompanying this • Water fuel seperator control and synchronizing and
it’s systems are checked before dispatch. product please contact your local dealer or visit: shutdowns
10.EQUIPMENT FINISHING all mild steel
• panels
WWW.STAUNCHMACHINERY.COM
components are fully degreased and painted with • Battery charger
powder coated paint to ensure maximum scuff
resistance and durability.