R419 Intelligent Animal Ventilator User Manual EN - V13
R419 Intelligent Animal Ventilator User Manual EN - V13
R419 Intelligent Animal Ventilator User Manual EN - V13
Ventilator
User Manual A
© 2020 Shenzhen RWD Life Science Co., Ltd, All rights reserved.
No individual and/or organization shall publish, modify, reproduce, issue, rental, adapted, and
translated into other languages without RWD’s writen permission.
is RWD’s registered trademark or mark, these trademarks and the related security
mark belong to RWD’s intangible property. The use of non RWD’s trademark or mark in this
instruction manual are only for editing purposes, without other purposes, the rights belong to their
respective rights owners.
Statement
RWD reserves the right to modify the content of this manual without prior notice.
RWD reserves the right to change the technology without prior notice.
RWD reserves the right to modify the product specifications without prior notice.
RWD does not guarantee the information in any forms, including (but not limited to) the
responsibility of proposing the implied merchantability and suitability for a specific purpose.
RWD in only the following conditions is considered to be responsible for the safety, reliability and
performance of the instruments, i.e.:
Assembly operation, expansion, adjustment, improvements and repairs carried out by RWD
authorized personnel;
RWD is not responsible for the products’ safety, reliability or operation status in the following
conditions:
1.2 Safety
In order to avoid the harm to the experimental animal or operator and the damages to the
ventilator, please refer to Chapter “2-System Safety”.
If you have any questions or suggestions related to safety, please contact our company for
after-sales service support.
The appearance is simple, light and elegantly colored, compact layout, and an overall
small size. It can be equipped with a respiratory anesthesia machine bracket, which is
flexible and convenient to operate;
Three modes are available: Volume Control Mode (VCV), Pressure Control Mode
(PIP-CV), and Apnea Mode (APNEA);
Equipped with two different sized bellows (300 ml and 1500 ml) suitable for animals
weighing less than 100kg;
Display specifications: 5-inch LCD color display is simple, intuitive, and easy to
operate, with real-time readings of monitored data;
Intelligent input: imports the commonly used animal breathing parameters into the
database, input the weight, and it automatically outputs the recommended breathing
parameter values;
Breathing parameter storage and recall;
Real-time display of breathing-related curve parameters, which is intuitive and
1
visual;
Auditory alarm, with text message prompts, improving human-machine interaction, and
reducing human error;
It is powered by an internal rechargeable battery and will run for more than 4 hours
while unplugged.
Fig 1
No. Parts Description
1 Bellows cover To isolate fresh gas from driving gas
Inputs fresh oxygen and anesthetic gas into the lungs of the
2 Folded bag
animal
3 Base To connect device and bellows
4 Display screen To display device operation information and set parameters
5 Battery indicator When powered by the battery, this indicator will be on.
External power After the equipment is connected to an external power
6
indicator source, this indicator will be on.
Refers to inspiration hold button. An inspiration will be
7 INSP.HOLD Button
held while this button is pressed.
Press button and hold for 1 second to start the equipment.
When you hear the equipment prompt tone, the equipment
8 Power switch button
is turned on, and will enter the self-calibration interface.
Pressing the button for 3 seconds will off the equipment.
2
Fig 2
No. Components Description
1 Fresh gas port To anaesthesia machine
2 anaesthetic wastes exhaust To gas filtration tank
port
3 17mm port To the port of the driving gas
4 Port of gas source Oxygen source (or air)
5 Port of pressure sensor To 22mm port
6 Air outlet Discharge waste gas of the driving gas
7 Port of the driving gas To 17mm port
8 Power adapter interface Power input port
1.5 Specification
Item Specification
Dimension 253mm×224mm×112mm
Weight 3.22kg
Respiratory rate 2~60 bpm
I:E 1:1.0~1:4.0
Tidal volume 20~1500ml
Peak inspiratory pressure 5~35 cmH2O
Trigger pressure -9.0 ~ -1.0 cmH2O
Patient weight range ≤100.0kg
Touch screen 5 inch, 800 × 480
3
2-System Safety
2.1 Safety Instructions
For safety, please pay attention to the following items:
Please read the user’s manual carefully.
Operating conditions of R419 Smart Veterinary Ventilator:
Temperature: 0℃~ +40℃, humidity:15%~95% (non-
condensing),atmospheric pressure: 70kPa ~ 110kPa
Storage conditions of R419 Smart Veterinary Ventilator:
Temperature: -20℃~ +45℃, relative humidity : ≤95%, atmospheric pressure:
70kPa ~ 110kPa
Warning:
When high pressure oxygen meets combustible materials (lubricating grease, motor oil,
alcohol, etc.), it may cause an explosion:
Keep the equipment and all connections absolutely free of oil and grease.
It is strictly forbidden to smoke near the ventilator and/or ignite an open flame.
When installing and replacing the oxygen cylinder, use your hand as much as possible
to tighten all the connections on the oxygen cylinder and pressure relief valve. If you
need to use tools, do not use excessive force, it may cause damage to the threads and
sealing materials and may result in gas leakage.
Take measures to prevent the oxygen cylinder from tipping over. If the oxygen
cylinder falls over, the pressure relief valve may be damaged and cause an explosion.
Important:
Always open the pressure relief valve on the oxygen cylinder slowly to prevent
the surge of pressure from impacting the valve fittings inside the ventilator.
Always check the pressure of the oxygen cylinder. Do not completely exhaust the
oxygen in it, humidity in the surrounding air may invade it and cause parts to rust.
Attention:
Animals and the ventilator must be continuously observed during use.
The breathing circuit interconnected with the anesthesia machine needs to be
remain unobstructed and easy to observe. Avoid operations that may result in
covering or affecting their function (e.g. improper location of the animal).
A large number of quality assurance measures have been taken in the
development of the equipment software, and the risk due to software defects is
minimal.
Take measures to protect the rubber components from ultraviolet light and
prolonged direct sunlight, to avoid embrittlement of these parts.
2.2 Cautions
Before operating this equipment, the operator should meticulously read this user’s manual
and fully understand its contents.
Before using this equipment, please carefully check all connectors to ensure adequate
4
gas-tightness and to avoid any leakage.
Equipment malfunctions caused by improper cleaning, maintenance or operation will
be considered the user’s responsibility.
If someone disassembles the equipment’s main body without authorization, RWD shall stop
providing any quality assurance or technical maintenance service to this equipment. If the
user has any technical questions, please contact the authorized person or the RWD for
support.
Risk of electric shock: Laypeople are prohibited from removing the cover or panel of the equipment and
removing the built-in rechargeable battery.
DANGER: The use of flammable or explosive gases as a gas source for the equipment is prohibited.
Warning!!!
The R419 Smart Veterinary Ventilator should self-calibrate when started. If self-calibration
cannot be done, it means there may be some kind of circuit breakdown or internal pipe leakage. In
that case the user should turn off the equipment power and make sure the gas source pressure is
between 41-87 psi, the breathing circuit connection is correct, and the flow rate of the anesthesia
machine is appropriate (note that the breathing circuit is connected to the breathing bag at this time,
and the evaporating tank of the anesthesia machine is closed). Then, turn on the equipment for self-
calibration after the folded bag in the bellows of the ventilator rises to the top of the bellows. If
self-calibration fails again, please contact your supplier or the RWD after-sales service department
for further support.
Warning!
It is forbidden to use the oxygen flush button on the anesthesia machine
during the inspiration phase of the breathing cycle. It may cause severe lung
rupture in the animal. During the inspiration phase, the drain valve in the control
unit is closed, so the oxygen flow is added to the breathing machine's air supply
flow, and the only direction of the airflow is to the lungs of the experimental
animal.
2.4 Warranty
The warranty of this equipment starts from the day it leaves the factory. If the equipment cannot
be used normally due to problems such as materials and/or process defects, the company
undertakes after-sales service such as maintenance and/or part replacement.
5
Any damage caused by improper use is not covered by the warranty. If repair or replacement
of parts is required, the cost will be borne by the user.
If the equipment that has been returned for repair has been dismantled without the
authorization of RWD before arriving at RWD, the company does not provide after-sales
service such as warranty, free maintenance or parts replacement.
The warranty statement (including its restrictions) is exclusively issued by RWD and covers
all other warranties.
6
3-Unpacking and Assembly
1) Inspect the packing for any signs of damage that may have occurred during shipping, if
damage has occurred, make a damage claim to the carrier and contact with RWD or
your local dealer immediately.
2) Remove all components from the shipping carton. Save all boxes and packing materials
for future shipments.
3) Check the packing list to ensure all components ordered are included. Ifthere is any
doubt or you need help, contact RWD or your local dealer immediately.
Packing list:
Device body -------------------------------------------------------1
300ml Bellows and bellows cover --------------------------------------1
1500 ml Bellows and bellows cover ----------------------------------- 1
1.2 m Bellows pipe ------------------------------------------------- 1
(For connecting ventilators and gas filter cans)
0.9m Reusable threaded pipe ---------------------------------------- 1
(Used to connect anesthesia machines and ventilators, can be steam sterilized)
Airway pressure connection pipe - Luer-22mm connector ------------------ 1
Rubber booster tube(ID : 15mm) -------------------------------------1
30-22mm Bellows joint ----------------------------------------------1
Power cable----------------------------------------------------------- 1
Power Adapter ------------------------------------------------------ 1
Warranty card -------------------------------------------------------1
User manual ------------------------------------------------------------ 1
Note: If your order contains other gadgets, it may also be packed at the same time. Please refer to the
waybill.
3.2 Installation
i. Check that the control host (main body) is intact and all interfaces on the rear panel, to
ensure that the air supply port (SUPPLYGAS), the driving gas port (DRIVING GAS),
and the exhaust port (EXHAUST) are not blocked;
ii. Check that the bellows and bellows cover are intact and that there is no debris inside
bellows;
iii. Install the bellows and bellows cover. Make sure the corrugated sheath at the bottom of
the bellows around the mounting ring of the control host, gently holds the outer edge
7
of the bellows disc (top of the bellows), lift it up and down, and repeat several times to
smooth out the ripples on the bellows. Then replace the bellows cover and gently press
and rotate the bellows cover clockwise until it snaps into the bayonet at the base. The
bellows and bellows cover are now installed.
Fig 3
iv. Connect the pipes of the driving gas. Use a rubber boosting tube to connect the 17mm
port of the bellows base to the driving gas port (DRIVING GAS) on the control unit;
Fig 4
v. Install the breathing circuit port. Connect the airway pressure connection pipe (Luer
taper) on the side of the airway pressure connection pipe - Luer -22mm connector to
the port of pressure sensor (PRESSURE TRANSDUCER) of the control unit, tighten
it, and then install the 22mm connector (transparent) onto the 22mm port of the
bellows base;
8
Fig 5
vi. Connect the ventilator to the anesthesia system. Remove the breathing bag from the
anesthesia machine and connect the 22mm port on the bellows base to the breathing
bag interface of the anesthesia machine with a threaded pipe;
Fig 6
vii. Connect the ventilator to the gas recovery system. Connect the 22mm bellows
connector to the 30mm port on the bellows base and connect to the gas filtering tank
using the bellows.
Fig 7
viii. Connect the gas supply system. Use an oxygen tube and a three-way valve to connect
the pressure relief valve of oxygen cylinder (gas output pressure should range from 41
to 87psi) to the air supply port (SUPPLY GAS) on the ventilator. The other outlet of
three-way valve is connected to the air interface of the anesthesia system.
9
4-Operating Instruction
4.1 Power-On self-calibration/test
1) Connect the gas source pipes of the anesthesia machine and the R419 intelligent ventilator,
turn on the gas source switch, adjust the pressure output of the decompression meter to 50
psi (0.344 MPa recommended value), and confirm that the volatilization tank switch of
anesthesia machine is adjusted to “0” position;
2) Connect the breathing circuit according to Section 3.2, open the anesthesia machine
flowmeter, and adjust the flow rate to about 1 L/min. When the folded bag of R419 Smart
Veterinary Ventilator bellows rises to the top of the transparent cover, press and hold the
power switch for 1 second to start the equipment. The equipment will give a click sound and
enter the self-calibration interface. Self-calibration will test the power source voltage,
battery voltage, air source pressure, airway pressure and sensor.
Fig 8
3) After the self-calibration passes, the interface automatically enters the main interface after 3
seconds;
Fig 9
10
After the R419 Smart Veterinary Ventilator enters the main interface, users can set the breathing
parameters such as the inspiration/ expiration ratio and airway pressure upper limit alarm. Press
to enter sub-main interface for setting the system parameters, such as adjusting the brightness
of the LCD screen.
Fig 10
the upper pressure limit displayed on the main interface of the ventilator to 30cmH2O,
click to start, after several breathing cycles, the real-time tidal volume(VT)reaches the set
value, then press the HOLD button until the airway pressure value rises or falls slowly. Rising
means the air tightness is good. If it is falling, no more than 3 cmH2O within 10 seconds, the air-
tightness is still considered adequate. If the drop in pressure exceeds these values, there may be a
problem with air leakage or tube circuitry. After having checked that the tube is tightly
connected, and the airway pressure still drops more than 3 cmH2O in less than 10 seconds, then
there is a leak in the ventilator. It is recommended that the user follows the above steps to
regularly check the ventilator, to avoid affecting its operation.
11
Fig 11
Volume Control Mode (VCV): With tidal volume (VT) as the reference standard, the
inspiration process is complete when the volume of gas inhaled by the animal reaches the set tidal
volume;
Pressure Control Mode (PIP-CV): With peak inspiratory pressure (PIP) as the reference
standard, the inspiration process is complete when the gas inhaled by the animal reaches the set
peak inspiration pressure;
Apnea Mode (APNEA): Selecting this mode will allow the animal to spontaneously breath;
when the animal does not breath for a pre-set period of time, the air supply starts immediately,
and delivers the pre-set assisted ventilation. This process will cease when the animal begins to
spontaneously breath again. If the user observes that the animal has begun to spontaneously
breath, and assisted ventilation is no longer necessary, the user can stop the ventilator and end
assisted ventilation.
12
Fig 12
Fig 13
Fig 14
3) After deleting the last named parameter group in the parameter list interface, the [Delete]
button is disabled;
4) The “Unnamed” parameter group cannot be deleted, it is optional, and the [Delete] button
is disabled;
5) The main interface uses the parameter group ABC, the parameter list interface pre-deletes
the parameter group, and displays the prompt "It is in use and cannot be deleted” Click the
OK button to exit the pop-up box;
Fig 15
15
3) After adjusting the parameters during ventilation, the newly adjusted parameters will be
executed during the next inspiration phase, and the current breathing cycle will not
forcibly interrupted.
Fig 16
4.7.3 Calibration
1)Click to enter the interface as shown in the figure below (Note: be sure to
unplug the threaded pipe shown in Figure 18 before calibration), and click the “Clear”
button on the right side of “Airway Pressure sensor”. (We recommended this to be cleared
monthly)
16
Fig 17
Fig 18
17
Fig 19
a. The information bar shows "High Airway Pressure!" indicating that the airway
pressure is excessive. A continuous auditory alarm "beep" will sound. At this point, the
ventilator will automatically end ventilation, keeping the airway pressure value within
the set value range, and it will then enter the ventilation cycle. When the airway
pressure returns to the set value range, this alarm message and status will be
automatically cancelled. When an alarm occurs, check the breathing circuit
immediately to confirm that it is connected correctly, the tidal volume is correct, and
confirm whether the set Maximum Pressure Limit (PLIMmax) is suitable for the
animal or the animal’s current state.
b. When the airway pressure is too low, the device starts to sound an alarm. If the
current airway pressure is lower than 2 cmH2O, check the breathing circuit
immediately to see whether the breathing circuit is damaged or leaking. The flowmeter
of the anesthesia machine is normally open.
c. This alarm message can appear in both states of “standby or normal operation”.
To find the cause of the leak:
1. Prepare a soapy water solution with a perfume-free soap.
2. Use this solution to wet all threaded connectors and hose connectors.
Bubbles will form where there are leaks in the system.
3. Remove the pressure from the system: to do this the oxygen cylinder must
be turn off. Turn the host (main body of equipment) on for a while until the
pressure gauge on the oxygen cylinder reads "0". Then shut down the host
again.
4. If there is a leak, replace the damaged part.
5. Then recheck for air tightness and leaks.
6. If the leak cannot be eliminated, it must be repaired.
Note: Before the ventilator is used again, be sure to have a professional physician set the
appropriate airway pressure according to the animal. If the VT setting value is too low, the
animal will not be able to inhale sufficiently. If the VT setting value is too high, the animal's
chest and lungs will over-inflate, causing chest and lung injury.
It is recommended to operate this equipment under the guidance of a physician, pre-set the
approximate airway pressure value, observe the animal's chest and lung undulation and blood oxygen
saturation, blood gas and other breathing parameters, and that those values are within the ideal range. If
there is a deviation, then make a subtle adjustments.
18
Fig 20
b. The information bar displays “Low Gas Source Pressure!” and “High Gas Source
Pressure!”, accompanied by a continuous alarm sound, indicating that the air supply
pressure is too low/high! Please check the oxygen cylinder or the central air supply
source immediately, confirm that the air supply connection is properly connected, and the
joint is not loose or leaking, and adjust the output pressure of the oxygen cylinder relief
valve or the central air supply source to 41 ~87psi, and make sure the cylinder pressure is
not less than 50bar (about 5MPa) to ensure sufficient working time.
c. This alarm message can appear in both states of “standby” or “normal” operation
Note: Please slowly open the gas valve of the oxygen cylinder. The cylinder pressure can now
be viewed on the pressure gauge of the pressure relief valve. For example, a 200 bar reading
indicates that the cylinder is sufficient, and a 100 bar reading indicates that only half of the
cylinder is available.
Note: When the cylinder pressure is less than 50 bar, the oxygen cylinder should be replaced
to ensure sufficient working time. After turning on the gas valve on the oxygen cylinder, turn
it off again and observe the pressure gauge indicator on the pressure relief valve. If the pointer
position remains the same, the system is airtight. If the pointer continues to drop, there is a
leak.
19
forcibly compress the folded bag of bellows to output gas, which is abnormal.
The ventilator will be automatically held now, please check the breathing circuit
immediately, and confirm that the breathing circuit is connected correctly, including if
it is falling off or loose. Check whether the anesthesia breathing pipe is blocked or bent,
and if the flow meter of anesthesia machine correctly adjusts the output of gas flow.
Before running the equipment again, be sure to raise the folded bag of ventilator
bellows to the top of the bellows!
b. This alarm message appears in the "normal operation" state.
Warning: Do not operate when the folded bag of ventilator bellows does not rise to the top
of the bellows! Running in this state for a long time may cause damage to the equipment.
21
5-Cleaning and Maintenance
5.1 Product Cleaning
The majority of the ventilator is not in direct contact with anesthetic gases, so only a dry
cloth is required for cleaning. Cleaning the surface of the ventilator: The surface can be wiped
with a clean, soft, damp cloth. Neutral cleaning agents can be used to remove stubborn stains.
Warning!
Use only water and a neutral detergent to clean the bellows and bellows cover. Wipe with a
soft cloth. Do not use a rough cloth or a scented cleaning agent. Be careful not to use ethanol for
cleaning.
Cleaning the bellows cover: Rotate the bellows cover counterclockwise until the buckle is
completely exposed (this step requires a large external force due to the action of the sealing ring),
and lift the bellows cover vertically. Since the bellows cover is not in direct contact with anesthetic
gases, it is only necessary to wipe it with a clean, damp cloth, or dip in a neutral detergent and
rinse with water. High temperature steam cannot be used to sterilize the bellows cover. High
temperature steam will cause the bellows cover to deform to the point of being unusable. Be
careful not to use ethanol for cleaning.
22
Warning!
Do not disassemble the battery, put it into fire, or short-circuit it. Burning, exploding, or
leaking batteries can cause personal injury.
23
6-Troubleshooting
If there are other malfunctions in the ventilator, please refer to the “Troubleshooting Table” for
potential solutions. If the fault still cannot be eliminated, please contact the relevant RWD personnel.
Fault description Possible cause Methods for Troubleshooting
1)No gas supply pressure a. Check if the air supply line is folded or
2)The inspiration adjustment blocked.
When the ventilator is running,
knob is set at the minimum value b. Insufficient air source pressure
the sound of the valve tapping
3)The air pressure at the input of c. Adjust the inspiration capacity
can be heard but it is not d. The gas source supply of the anesthesia
working, and the ventilator the ventilator is excessively low
machine does not meet the flow
makes a buzzing sound when requirements, and a new gas supply source
the animal is breaths.
is required.
24
7-Return to factory for repair
It is forbidden to return the ventilator or related components to the company without
authorization. Please contact RWD personnel to obtain the authorization before returning equipment
or components.
If the equipment needs to be returned to the factory, please prepare and provide the
following information:
a) Serial number and user manual of equipment
b) Problem description, return reason and request
c) Contact information of the relevant personnel of your company (telephone
and detailed address)
d) If the equipment returned for repair involves fee issues, please provide the
contact information (phone and detailed address) of a person authorized to
make payments for your company.
Note: Please properly pack the equipment and components to be repaired so as to avoid
secondary damage during transportation!
25
8-After-sale service
RWD Life Science Co., Ltd is headquartered in Nanshan District High-tech Park, Shenzhen.
Since its establishment in 2002, it has always been committed to providing customers with high-
quality services. Pursuing customer satisfaction is our consistent goal. The company has a strong after-
sales service team and insists on providing customers with 24/7 service.
The company also has offices in 31 provinces and cities including Guangzhou, Shanghai, Chengdu,
Nanjing, Hangzhou, Kunming, Xi'an, Taiyuan and Shandong. It has set up an after-sales service center in
Beijing, and will establish after-sales service centers in other cities such as Shanghai, covering more cities.
This initiative will respond quickly to customer service needs, minimizing losses caused by equipment
failures.
In the meanwhile, passing through the unremitting endeavor of years, we have also established a
friendly partnership with distributors across the country, created a national comprehensive after-sales
service system, and maintained long-term stable cooperative relations with new and regular customers.
26
9-Technical parameters
Appendix 1. PIP-CV Parameter Setting Reference
Max airway
WEIGHT Freq Trig Recommended
pressure
(Kg) (bpm) (cmH20) flow
(cmH2O)
2 18 10 -2 2
2.5 18 10 -2 2
3 18 12 -2 2
3.5 18 12 -2 3
4 18 12 -2 3
4.5 18 12 -2 4
5 18 12 -2 4
5.5 12 12 -2 3
6 12 12 -2 3
6.5 12 12 -2 4
7 12 12 -2 4
7.5 12 12 -2 4
8 12 12 -2 4
8.5 12 12 -2 5
9 12 12 -2 5
9.5 12 12 -2 5
10 12 12 -2 6
11 12 13 -3 6
12 12 13 -3 7
13 12 13 -3 7
14 12 13 -3 8
15 12 13 -3 8
16 12 13 -3 9
17 12 13 -3 9
18 12 13 -3 10
19 12 13 -3 10
20 12 13 -3 11
21 12 16 -3 12
22 12 16 -3 12
23 12 16 -3 13
24 12 16 -3 13
25 12 16 -3 14
26 12 16 -3 14
27 12 16 -3 15
28 12 16 -3 15
29 12 16 -3 16
27
Max airway
WEIGHT Freq Trig Recommended
pressure
(Kg) (bpm) (cmH20) flow
(cmH2O)
30 12 16 -3 17
31 9 16 -3 14
32 9 16 -3 14
33 9 16 -3 15
34 9 16 -3 15
35 9 16 -3 16
36 9 18 -3 16
37 9 18 -3 17
38 9 18 -3 17
39 9 18 -3 18
40 9 18 -3 18
41 9 18 -3 19
42 9 18 -3 19
43 9 18 -3 19
44 9 18 -3 20
45 9 18 -3 20
46 9 18 -3 21
47 9 18 -3 21
48 9 18 -3 22
49 9 18 -3 22
50 9 18 -3 23
51 9 18 -3 23
52 9 18 -3 23
53 9 18 -3 23
54 9 20 -3 24
55 9 20 -3 24
56 9 20 -3 24
57 9 20 -3 25
58 9 20 -3 25
59 9 20 -3 26
60 9 20 -3 26
61 9 22 -3 26
62 9 22 -3 27
63 9 22 -3 27
64 9 22 -3 27
65 9 22 -3 28
66 9 22 -3 28
67 9 22 -3 28
68 9 22 -3 29
28
Max airway
WEIGHT Freq Trig Recommended
pressure
(Kg) (bpm) (cmH20) flow
(cmH2O)
69 9 22 -3 29
70 9 22 -3 29
71 9 22 -3 30
72 9 22 -3 30
73 9 22 -3 30
74 9 22 -3 31
75 9 22 -3 31
76 9 22 -3 31
77 9 22 -3 32
78 9 22 -3 32
79 9 22 -3 32
80 9 22 -3 33
81 9 22 -3 33
82 9 22 -3 34
83 9 22 -3 34
84 9 22 -3 34
85 9 22 -3 35
86 9 22 -3 35
87 9 22 -3 35
88 9 22 -3 36
89 9 22 -3 36
90 9 22 -3 36
91 9 22 -3 37
92 9 22 -3 37
93 9 22 -3 37
94 9 22 -3 38
95 9 22 -3 38
96 9 22 -3 38
97 9 22 -3 39
98 9 22 -3 39
99 9 22 -3 39
100 9 22 -3 40
29
Appendix 2. VCV Mode Breathing Parameter Setting Reference
airway
WEIGHT Freq Trig standard measured
pressure limit I:E ratio
(Kg) ( bpm) ( cmH20) VT VT
(cmH2O)
2 18 13 -2 1:2 14.3 29
2.5 18 13 -2 1:2 14.3 36
3 18 15 -2 1:2 14.3 43
3.5 18 15 -2 1:2 14.3 50
4 18 15 -2 1:2 14.3 57
4.5 18 15 -2 1:2 14.3 64
5 18 15 -2 1:2 14.3 72
79
5.5 12 15 -2 1:2.2 14.3
6 12 15 -2 1:2.2 14.3 86
6.5 12 15 -2 1:2.2 14.3 93
7 12 15 -2 1:2.2 14.3 100
7.5 12 15 -2 1:2.2 14.3 107
8 12 15 -2 1:2.2 14.3 114
8.5 12 15 -2 1:2.2 14.3 122
9 12 15 -2 1:2.2 14.3 129
9.5 12 15 -2 1:2.2 14.3 136
10 12 15 -2 1:2.2 14.3 143
11 12 16 -3 1:2.2 14.3 157
12 12 16 -3 1:2.2 14.3 172
13 12 16 -3 1:2.2 14.3 186
14 12 16 -3 1:2.2 14.3 200
15 12 16 -3 1:2.2 14.3 215
16 12 16 -3 1:2.2 14.3 229
17 12 16 -3 1:2.2 14.3 243
18 12 16 -3 1:2.2 14.3 257
19 12 16 -3 1:2.2 14.3 272
20 12 16 -3 1:2.2 14.3 286
21 12 20 -3 1:2.2 14.3 300
22 12 20 -3 1:2.2 14.3 315
23 12 20 -3 1:2.2 14.3 329
24 12 20 -3 1:2.2 14.3 343
25 12 20 -3 1:2.2 14.3 358
26 12 20 -3 1:2.2 14.3 372
27 12 20 -3 1:2.2 14.3 386
30
airway
WEIGHT Freq Trig standard measured
pressure limit I:E ratio
(Kg) ( bpm) ( cmH20) VT VT
(cmH2O)
28 12 20 -3 1:2.2 14.3 400
29 12 20 -3 1:2.2 14.3 415
30 12 20 -3 1:2.2 14.3 429
31 9 20 -3 1:2.5 14.3 443
32 9 20 -3 1:2.5 14.3 458
33 9 20 -3 1:2.5 14.3 472
34 9 20 -3 1:2.5 14.3 486
35 9 20 -3 1:2.5 14.3 501
36 9 23 -3 1:2.5 14.3 515
37 9 23 -3 1:2.5 14.3 529
38 9 23 -3 1:2.5 14.3 543
39 9 23 -3 1:2.5 14.3 558
40 9 23 -3 1:2.5 14.3 572
41 9 23 -3 1:2.5 14.3 586
42 9 23 -3 1:2.5 14.3 601
43 9 23 -3 1:2.5 14.3 615
44 9 23 -3 1:2.5 14.3 629
52 9 23 -3 1:2.5 11 732
53 9 23 -3 1:2.5 11 743
54 9 25 -3 1:2.5 11 754
55 9 25 -3 1:2.5 11 765
56 9 25 -3 1:2.5 11 776
57 9 25 -3 1:2.5 11 787
58 9 25 -3 1:2.5 11 798
59 9 25 -3 1:2.5 11 809
60 9 25 -3 1:2.5 11 820
61 9 28 -3 1:2.5 11 831
31
airway
WEIGHT Freq Trig standard measured
pressure limit I:E ratio
(Kg) ( bpm) ( cmH20) VT VT
(cmH2O)
62 9 28 -3 1:2.5 11 842
63 9 28 -3 1:2.5 11 853
64 9 28 -3 1:2.5 11 864
65 9 28 -3 1:2.5 11 875
66 9 28 -3 1:2.5 11 886
67 9 28 -3 1:2.5 11 897
68 9 28 -3 1:2.5 11 908
69 9 28 -3 1:2.5 11 919
70 9 28 -3 1:2.5 11 930
71 9 28 -3 1:2.5 11 941
72 9 28 -3 1:2.5 11 952
73 9 28 -3 1:2.5 11 963
74 9 28 -3 1:2.5 11 974
75 9 28 -3 1:2.5 11 985
76 9 28 -3 1:2.5 11 996
77 9 28 -3 1:2.5 11 1007
78 9 28 -3 1:2.5 11 1018
79 9 28 -3 1:2.5 11 1029
80 9 28 -3 1:2.5 11 1040
81 9 28 -3 1:2.5 11 1051
82 9 28 -3 1:2.5 11 1062
83 9 28 -3 1:2.5 11 1073
84 9 28 -3 1:2.5 11 1084
85 9 28 -3 1:2.5 11 1095
86 9 28 -3 1:2.5 11 1106
87 9 28 -3 1:2.5 11 1117
88 9 28 -3 1:2.5 11 1128
89 9 28 -3 1:2.5 11 1139
90 9 28 -3 1:2.5 11 1150
91 9 28 -3 1:2.5 11 1161
92 9 28 -3 1:2.5 11 1172
93 9 28 -3 1:2.5 11 1183
94 9 28 -3 1:2.5 11 1194
32
airway
WEIGHT Freq Trig standard measured
pressure limit I:E ratio
(Kg) ( bpm) ( cmH20) VT VT
(cmH2O)
95 9 28 -3 1:2.5 11 1205
96 9 28 -3 1:2.5 11 1216
97 9 28 -3 1:2.5 11 1227
98 9 28 -3 1:2.5 11 1238
99 9 28 -3 1:2.5 11 1249
100 9 28 -3 1:2.5 11 1260
33
Appendix 3. APNEA mode breathing parameter setting reference
airway apnea
WEIGHT Freq Trig I:E measured
pressure limit standard VT time
(Kg) ( bpm) ( cmH20) ratio VT
(cmH2O) (s)
2 18 13 -2 1:2 14.3 29 15
2.5 18 13 -2 1:2 14.3 36 15
3 18 15 -2 1:2 14.3 43 15
3.5 18 15 -2 1:2 14.3 50 15
4 18 15 -2 1:2 14.3 57 15
4.5 18 15 -2 1:2 14.3 64 15
5 18 15 -2 1:2 14.3 72 15
5.5 12 15 -2 1:2.2 14.3 79 15
6 12 15 -2 1:2.2 14.3 86 15
6.5 12 15 -2 1:2.2 14.3 93 15
7 12 15 -2 1:2.2 14.3 100 15
7.5 12 15 -2 1:2.2 14.3 107 15
8 12 15 -2 1:2.2 14.3 114 15
8.5 12 15 -2 1:2.2 14.3 122 15
9 12 15 -2 1:2.2 14.3 129 15
9.5 12 15 -2 1:2.2 14.3 136 15
10 12 15 -2 1:2.2 14.3 143 15
11 12 16 -3 1:2.2 14.3 157 15
12 12 16 -3 1:2.2 14.3 172 15
13 12 16 -3 1:2.2 14.3 186 15
14 12 16 -3 1:2.2 14.3 200 15
15 12 16 -3 1:2.2 14.3 215 15
16 12 16 -3 1:2.2 14.3 229 15
17 12 16 -3 1:2.2 14.3 243 15
18 12 16 -3 1:2.2 14.3 257 15
19 12 16 -3 1:2.2 14.3 272 15
20 12 16 -3 1:2.2 14.3 286 15
21 12 20 -3 1:2.2 14.3 300 15
22 12 20 -3 1:2.2 14.3 315 15
23 12 20 -3 1:2.2 14.3 329 15
24 12 20 -3 1:2.2 14.3 343 15
25 12 20 -3 1:2.2 14.3 358 15
26 12 20 -3 1:2.2 14.3 372 15
27 12 20 -3 1:2.2 14.3 386 15
28 12 20 -3 1:2.2 14.3 400 15
29 12 20 -3 1:2.2 14.3 415 15
30 12 20 -3 1:2.2 14.3 429 15
31 9 20 -3 1:2.5 14.3 443 15
34
airway apnea
WEIGHT Freq Trig I:E measured
pressure limit standard VT time
(Kg) ( bpm) ( cmH20) ratio VT
(cmH2O) (s)
32 9 20 -3 1:2.5 14.3 458 15
33 9 20 -3 1:2.5 14.3 472 15
34 9 20 -3 1:2.5 14.3 486 15
35 9 20 -3 1:2.5 14.3 501 15
36 9 23 -3 1:2.5 14.3 515 15
37 9 23 -3 1:2.5 14.3 529 15
38 9 23 -3 1:2.5 14.3 543 15
39 9 23 -3 1:2.5 14.3 558 15
40 9 23 -3 1:2.5 14.3 572 15
41 9 23 -3 1:2.5 14.3 586 15
42 9 23 -3 1:2.5 14.3 601 15
43 9 23 -3 1:2.5 14.3 615 15
44 9 23 -3 1:2.5 14.3 629 15
45 9 23 -3 1:2.5 14.3 644 15
46 9 23 -3 1:2.5 14.3 658 15
47 9 23 -3 1:2.5 14.3 672 15
48 9 23 -3 1:2.5 14.3 686 15
49 9 23 -3 1:2.5 14.3 701 15
50 9 23 -3 1:2.5 14.3 715 15
51 9 23 -3 1:2.5 11 721 15
52 9 23 -3 1:2.5 11 732 15
53 9 23 -3 1:2.5 11 743 15
54 9 25 -3 1:2.5 11 754 15
55 9 25 -3 1:2.5 11 765 15
56 9 25 -3 1:2.5 11 776 15
57 9 25 -3 1:2.5 11 787 15
58 9 25 -3 1:2.5 11 798 15
59 9 25 -3 1:2.5 11 809 15
60 9 25 -3 1:2.5 11 820 15
61 9 28 -3 1:2.5 11 831 15
62 9 28 -3 1:2.5 11 842 15
63 9 28 -3 1:2.5 11 853 15
64 9 28 -3 1:2.5 11 864 15
65 9 28 -3 1:2.5 11 875 15
66 9 28 -3 1:2.5 11 886 15
67 9 28 -3 1:2.5 11 897 15
68 9 28 -3 1:2.5 11 908 15
69 9 28 -3 1:2.5 11 919 15
70 9 28 -3 1:2.5 11 930 15
35
airway apnea
WEIGHT Freq Trig I:E measured
pressure limit standard VT time
(Kg) ( bpm) ( cmH20) ratio VT
(cmH2O) (s)
71 9 28 -3 1:2.5 11 941 15
72 9 28 -3 1:2.5 11 952 15
73 9 28 -3 1:2.5 11 963 15
74 9 28 -3 1:2.5 11 974 15
75 9 28 -3 1:2.5 11 985 15
76 9 28 -3 1:2.5 11 996 15
77 9 28 -3 1:2.5 11 1007 15
78 9 28 -3 1:2.5 11 1018 15
79 9 28 -3 1:2.5 11 1029 15
80 9 28 -3 1:2.5 11 1040 15
81 9 28 -3 1:2.5 11 1051 15
82 9 28 -3 1:2.5 11 1062 15
83 9 28 -3 1:2.5 11 1073 15
84 9 28 -3 1:2.5 11 1084 15
85 9 28 -3 1:2.5 11 1095 15
86 9 28 -3 1:2.5 11 1106 15
87 9 28 -3 1:2.5 11 1117 15
88 9 28 -3 1:2.5 11 1128 15
89 9 28 -3 1:2.5 11 1139 15
90 9 28 -3 1:2.5 11 1150 15
91 9 28 -3 1:2.5 11 1161 15
92 9 28 -3 1:2.5 11 1172 15
93 9 28 -3 1:2.5 11 1183 15
94 9 28 -3 1:2.5 11 1194 15
95 9 28 -3 1:2.5 11 1205 15
96 9 28 -3 1:2.5 11 1216 15
97 9 28 -3 1:2.5 11 1227 15
98 9 28 -3 1:2.5 11 1238 15
99 9 28 -3 1:2.5 11 1249 15
100 9 28 -3 1:2.5 11 1260 15
36
RWD Life Science
Web: www.rwdstco.com
Add: 6540 Lusk Blvd, San Diego, CA 92121,USA
Add: Room201, Robeta Building, No.11 High Tech
North 4th Road, Nanshan District, Shenzhen City,
Guangdong Province, 518057, China
Tel: +001-858-900-6602 +86-755-86111286
After-sales Service: +86-755-86111281
After-sales E-mail: service@rwdstco.com