F E AT U RES

• Heat Transfer Pad with Excellent


Temperature Response

• Rugged Stainless Steel Sheath Provides


Excellent Mechanical Protection

• Replaceable Element Design


Simplifies RTD Replacement

U N I T E D E L E C T R I C C O N T R O L S 2

UNITED ELECTRIC
CONTROLS
RTDs

overview features
R TDs

United Electric Controls offers a broad range of temperature sensors. Simplify installation and address
We design, engineer and manufacture the following types of sensor maintenance issues with United Electric
assemblies: Controls Heat Trace RTDs capable for
use in any pipe or surface temperature
measuring application, these sensors
• Thermocouples have been specifically designed for use
with electronic heat control products.
• RTDs (both wire wound and thin film)
• Thermistors United Electric Controls heat trace
• Integrated Circuit (IC) products have:
• Heat transfer pad for maximum
All of our products are known for their consistent high reliability and durability. temperature response
We are continually examining and improving our engineering, production and
service operations to meet constantly evolving customer requirements. Our • Rugged stainless steel sheath
ISO 9001 certification is objective proof of our company-wide commitment for excellent mechanical
to quality. protection

• Replaceable RTD e-clamps


UE Temperature Sensor Group

UE has recognized the importance of Temperature Sensors to the future of Replaceable element design simplifies
United Electric Controls. We have assembled a talented group of Temperature and reduces the cost of sensor
Sensor experts to form our Sensor Group at our Headquarters in Watertown, replacement. United Electric Controls
MA. This organization is specifically formed to serve our wide spectrum of Heat Trace RTDs make the job of
customers. We have experienced professionals dedicated to producing the replacing a faulty element easy. With
best temperature sensors for your products. This group consists of experts with old style Heat Trace RTDs, several time-
extensive Temperature Sensor experience in: consuming and expensive steps need to
be executed to replace a faulty element.
• Sales
• Design
• Engineering
• Supplier Development
• Manufacturing
• Customer Service
• Marketing
• Quality Assurance

2 U N I T E D E L E C T R I C C O N T R O L S

Uncontrolled if printed
RTDs

TECHNOLOGY

The process routinely involves 3 trades When choosing which temperature sensor to use there are many things to
to make a change – insulation handlers, consider. One very important decision is selecting the type of sensor that best
welders and technicians. This results in fits your requirement. For use in heat trace applications, RTDs provide the best
significant cost and downtime. accuracy. Below is a description of the characteristics of RTDs.
With United Electric Controls Heat Trace
RTDs with replaceable elements, the
process is not only simpler, but much RTDs or Resistance Temperature Detectors
quicker and more cost-effective. To
replace a faulty element, you simply RTDs are stable and have a fairly wide temperature range, but are not as
remove the head cover, disconnect the rugged as thermocouples.
leads and remove the element. You then
insert the new element and reconnect An RTD capitalizes on the fact that the electrical resistance of a material
the leads. Your process is up and changes as its temperature changes. RTDs rely on the resistance change in a
running in minutes. metal. The resistance will rise more or less linearly with temperature.

RTDs are used to measure temperatures from -196°C to 500°C (-320°F to


932°F).

Here is a summary of some of the advantages and disadvantages of RTDs:

Advantages Disadvantages

Most Stable Slower Response Time


Most Accurate Current Source Required
More Linear than Thermocouples Self-heating
Better Repeatability Less Robust than Thermocouples

U N I T E D E L E C T R I C C O N T R O L S 3

Uncontrolled if printed
RTDs

specifications
R TDs

NEMA 4 CAST ALUMINUM HEAD WITH REPLACEABLE ELEMENT T1804

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0° C
Tolerance: Class B, +/- 0.12%
Enclosure: Cast aluminum head; conforms to NEMA 4 requirements
Sheath: 0.375” O.D. stainless steel
Operating Range: 0° to 482° C (32° to 900° F)

Uses replacement element T1805

Product Number Nominal Pipe Size O.D.


T1804-F Flat 0
T1804-5 0.50 0.84 ��

T1804-7 0.75 1.05


T1804-10 1.00 1.32
T1804-15 1.50 1.90 �
��

T1804-20 2.00 2.38
T1804-30 3.00 3.50
T1804-40 4.00 4.50
T1804-60 6.00 6.63
T1804-80 8.00 8.63

4 U N I T E D E L E C T R I C C O N T R O L S

Uncontrolled if printed
RTDs

EXPLOSION PROOF CAST ALUMINUM HEAD WITH REPLACEABLE ELEMENT T1804X

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
Enclosure: Cast aluminum head; approved for Class I,
Division I, Groups C, D; Class II, Groups E,F,G
Sheath: 0.375” O.D. stainless steel
Operating Range: 0° to 482°C (32° to 900°F)

Uses replacement element T1805


��

Product Number Nominal Pipe Size O.D.


T1804X-F Flat 0
T1804X-5 0.50 0.84 �
��

T1804X-7 0.75 1.05
T1804X-10 1.00 1.32
T1804X-15 1.50 1.90
T1804X-20 2.00 2.38
T1804X-30 3.00 3.50
T1804X-40 4.00 4.50
T1804X-60 6.00 6.63
T1804X-80 8.00 8.63

NEMA 4X CAST IRON, EPOXY COATED HEAD WITH REPLACEABLE ELEMENT T1855

Element type: Dual element, 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
Enclosure: Cast iron head with epoxy coating; conforms to NEMA 4X requirements
Sheath: 0.375” O.D. stainless steel
Operating Range: 0° to 482°C (32° to 900°F)

Uses replacement element T1805D

Product Number Nominal Pipe Size O.D.


T1855-F Flat 0 ��
T1855-5 0.50 0.84
T1855-7 0.75 1.05
T1855-10 1.00 1.32
T1855-15 1.50 1.90 �
��

T1855-20 2.00 2.38


T1855-30 3.00 3.50
T1855-40 4.00 4.50
T1855-60 6.00 6.63
T1855-80 8.00 8.63

U N I T E D E L E C T R I C C O N T R O L S 5

Uncontrolled if printed
RTDs

NEMA 4X POLYCARBONATE BOX WITH REPLACEABLE ELEMENT T1844


R TDs

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
Enclosure: Polycarbonate head; conforms to NEMA 4X requirements, 6 knock-outs

Sheath: 0.375 O.D. stainless steel


Operating Range: 0° to 482°C (32° to 900°F)

Uses replacement element T1805

Product Number Nominal Pipe Size O.D.


T1844-F Flat 0 ��
T1844-5 0.50 0.84
T1844-7 0.75 1.05
T1844-10 1.00 1.32
T1844-15 1.50 1.90 �
��

T1844-20 2.00 2.38
T1844-30 3.00 3.50
T1844-40 4.00 4.50
T1844-60 6.00 6.63
T1844-80 8.00 8.63

NEMA 4 CAST ALUMINUM HEAD/FIXED ELEMENT T1441

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
Enclosure: Cast aluminum head; conforms to NEMA 4 requirements
Sheath: 0.250” O.D. stainless steel
Operating Range: -18°C to 371°C (0° to 700°F) ��

Product Number
T1441
��

6 U N I T E D E L E C T R I C C O N T R O L S

Uncontrolled if printed
RTDs

CAST ALUMINUM HEAD WITH REPLACEABLE ELEMENT T1441X

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
Enclosure: Cast aluminum head; See T1804X
Sheath: 0.250” O.D. stainless steel
Operating Range: -18°C to 371°C (0°F to 700°F)
��
� �

Product Number
T1441X
��

100 OHM RTD ASSEMBLY WITH FLEXIBLE MI CABLE CONSTRUCTION T1792

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C �� ±��
Tolerance: Class B, +/- 0.12%
Sheath: 0.250” O.D. stainless steel
Operating Range: -18° to 780°C (0° to 1400°F) maximum

Product Number Length (in inches) L Instrument


T1792 120 1/2” NPT �

T1792-8 8 1/2” NPT


T1792-10 10 1/2” NPT
T1792-12 12 1/2” NPT

SINGLE AND DUAL “BULLET” RTD REPLACEMENT ELEMENT


(For T1804, T1804X, T1855, T1844) ��
� �

Element type: 3 wire construction, DIN 0.00385


Resistance: 100 ohms @ 0°C
Tolerance: Class B, +/- 0.12%
���
Sheath: 0.250” O.D. stainless steel
Lead: 22 AWG, fiberglass insulation, st/st armor
Operating Range: 0° to 482°C (32° to 900°F)
��

Product Number
T1805 Single element
T1805D Dual element

U N I T E D E L E C T R I C C O N T R O L S 7

Uncontrolled if printed
U.S. SALES OFFICES INTERNATIONAL OFFICES
RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls AUSTRALIA
32 Highland Rd. United Electric Controls
United Electric Controls Company recommends careful consideration South Hampton, NH 03827 (Australia) PTY Ltd
of the following factors when specifying and installing UE pressure Phone: 603-394-0078 Unit 2, 615 Warrigal Road
and temperature units. Before installing a unit, the Installation and FAX: 603-394-0175 Locked Bag 600
Maintenance instructions provided with unit must be read and understood. Ashburton, Victoria
• To avoid damaging unit, proof pressure and maximum temperature United Electric Controls 3147, Australia
limits stated in literature and on nameplates must never be exceeded, even 28 N. Wise Ave. Phone: 613-9567-0750
by surges in the system. Operation of the unit up to maximum temperature FAX: 613-9567-0755
Freeport, IL 61032
is acceptable on a limited basis (i.e., start-up, testing) but continuous
operation must be restricted to the designated adjustable range. Excessive
Phone: 815-235-3501 BELGIUM
cycling at maximum temperature limits could reduce sensor life. FAX: 815-235-3847 United Electric Controls-Europe
• A back-up unit is necessary for applications where damage to G. Van Gervenstraat 19A
a primary unit could endanger life, limb or property. A high or low United Electric Controls B-9120 Beveren-Waas, Belgium
limit switch is necessary for applications where a dangerous runaway 1022 Vineyard Drive Phone: 32-37554-383
condition could result. Conyers, GA 30013 FAX: 32-37552-747
• The adjustable range must be selected so that incorrect, inadvertent Phone: 770-483-8400
or malicious setting at any range point cannot result in an unsafe system FAX: 770-929-8716 CANADA
condition. United Electric Controls
• Install unit where shock, vibration and ambient temperature United Electric Controls (Canada) Ltd
fluctuations will not damage unit or affect operation. Orient unit so that 5829 Grazing Court 5320 Bradco Boulevard
moisture does not enter the enclosure via the electrical connection. When Mason, OH 45040 Mississauga, Ontario
appropriate, this entry point should be sealed to prevent moisture entry. Phone: 513-398-3175 L4W 1G7 Canada
• Unit must not be altered or modified after shipment. Consult UE if FAX: 513-398-3076 Phone: 905-625-5082
modification is necessary. FAX: 905-625-5709
• Monitor operation to observe warning signs of possible damage to United Electric Controls GERMANY
unit, such as drift in set point or faulty display. Check unit immediately. United Electric Controls
19335 Hadley
• Preventative maintenance and periodic testing is necessary
Stilwell, KS 66085 An Der Zentlinde 21
for critical applications where damage could endanger property or
personnel. Phone: 913-685-2775 D-64711 Erbach, Germany
• For all applications, a factory set unit should be tested before use. FAX: 913-685-2774 Phone: 496-062-7400
• Electrical ratings stated in literature and on nameplate must not
FAX: 496-062-7501
be exceeded. Overload on a switch can cause damage, even on the first United Electric Controls INDIA
cycle. Wire unit according to local and national electrical codes, using 1753 Beach Street United Electric Controls
wire size recommended in installation sheet. San Francisco, CA 94123 Amar Hill, Saki Vihar Road
• Use only factory authorized replacement parts and procedures. Phone: 415-563-5811 Powai, Mumbai 400 072
• Do not mount unit in ambient temp. exceeding published limits. FAX: 415-563-5909 Phone: 91-22-857-6921
FAX: 91-22-857-1707
LIMITED WARRANTY OF REPAIR AND REPLACEMENT
Seller warrants that the product hereby purchased is, upon delivery, free MALAYSIA
from defects in material and workmanship and that any such product United Electric Controls, Far East
which is found to be defective in such workmanship or material will be No. 1-2-2, 2nd Floor
repaired or replaced by Seller (F.O.B. UE Watertown); provided, however, Jalan 4/101C
that this warranty applies only to equipment found to be so defective Cheras Business Centre
within a period of 18 months from the date of manufacture by the Seller Batu 5, Jalan Cheras
(36 months for the Spectra 12 and One Series products). Seller shall not 56100 Kuala Lumpur, Malaysia
be obligated under this warranty for alleged defects which examination Phone: 603-9133-4122
discloses are due to tampering, misuse, neglect, improper storage, and FAX: 603-9133-4155
in any case where products are disassembled by anyone other than
authorized Seller’s representatives.
MEXICO
EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT United Electric Controls
STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER Chihuahua 129-1 NTE
WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED Unidad Nacional 89410
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY Madero, TAM
PARTICULAR PURPOSE. Mexico
Phone: 52-833-210-0646
LIABILITY LIMITATION FAX: 52-833-210-5761
SELLER’S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING
LIABILIT Y INCURRED IN CONNECTION WITH (I) BREACH OF ANY
WARRANT Y WHATSOEVER EXPRESSED OR IMPLIED, (II) A BREACH
OF CONTRACT, (III) A NEGLIGENT ACT OR ACTS (OR NEGLIGENT
FAILURE TO ACT) COMMIT TED BY SELLER, OR (IV) AN ACT FOR
WHICH STRICT LIABILITY WILL BE IMPUTED TO SELLER, IS LIMITED
TO THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED
HEREIN. IN NO EVENT SHALL THE SELLER BE LIABLE FOR ANY SPECIAL,
INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES OF A LIKE GENERAL
NATURE, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS OR
PRODUCTION, OR LOSS OR EXPENSES OF ANY NATURE INCURRED BY
UNITED ELECTRIC
THE BUYER OR ANY THIRD PARTY. CONTROLS
UE specifications subject to change without notice.
180 Dexter Avenue, P.O. Box 9143
Watertown, MA 02471-9143 USA
Telephone: 617 926-1000 Fax: 617 926-2568
http://www.ueonline.com
EMCO50001201

Uncontrolled if printed

You might also like