Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Combo 8ui A5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

MODULUS 12/24V discrete input models

8x-3004 8DI, 4DO, 8UI


8x-3005 8DI, 4DO, 8UI, 4AI
COMBO Input/Output Modules 8x-3014 8DI, 4DO, 8UI, 4AO
with 8 Universal Analog Inputs 120/240V discrete input models
8x-3104 8DI, 4DO, 8UI
Modulus COMBO Input/Output modules extend the I/O capacity of 8x-3105 8DI, 4DO, 8UI, 4AI
Modulus SCADA controllers, as well as the many 3rd party devices 8x-3114 8DI, 4DO, 8UI, 4AO
that support industry standard communications protocols such as
Modbus, DF1, SDI-12 and Ethernet IP.

COMBO modules are available with 12/24V or 120/240V Discrete


Inputs. Both AC and DC signals are supported.

Modulus COMBO I/O modules have built-in web pages for configura-
tion, programming, monitoring and manuals. No application software
is needed; just a web browser. Custom user documentation can also
be loaded into the module, so that drawings, datasheets, etc. are
always available for site support and maintenance. Modulus COMBO I/O Module

• 8 DISCRETE INPUTS (OPTICALLY ISOLATED)


• 4 DISCRETE OUTPUTS (RELAY)
• 8 UNIVERSAL ANALOG INPUTS (w/SENSOR CONDITIONING)
• 4 OPTIONAL ADDITIONAL ANALOG INPUTS OR OUTPUTS
• 1 ETHERNET PORT
• 2 SERIAL PORTS (BUS PORT PLUS 1 GENERAL PURPOSE PORT)

STANDALONE OPERATION ALARMING


Modulus COMBO I/O modules can serve as standalone devices with A COMBO module can manage alarm conditions on any of it’s local
SCADA communications, local and web human machine interfaces inputs, as well as over 500 conditions monitored by communications
(HMIs), trending and data logging, alarming, reporting, and program- with other devices. Alarms conditions can be displayed locally and
mable logic control. annunciated by a contact closure on one of its outputs, or in tandem
with other devices such as a Modulus Cellular Communications mod-
COMMUNICATIONS
COMBO modules have an Ethernet port and two serial ports to com- ule (for text message and e-mail alerts). The module maintains a

municate directly with Modbus devices, as well as Allen Bradley journal spreadsheet file of when alarms occurred, when they were

PLCs. Ethernet to Serial bridging is also supported. The module can acknowledged, by whom, and when the alarm conditions cleared.

also serve as a communications concentrator or master controller. PROGRAMMABLE LOGIC


Each COMBO module supports programmable logic written in any
GRAPHICAL, MOBILE, AND LOCAL HMIs
Configurable graphical web and mobile device interfaces are built mix of ladder logic, function block and text languages. Programmable

into COMBO modules. The front panel display can also be custom- logic can be used for anything that can’t be done with the built-in

ized to show live process values and states, and make setting functions of the module.

changes. PID AND PUMP CONTROL


COMBO modules support four Proportional, Integral and Derivative
HISTORICAL TRENDING AND EVENT LOGGING
COMBO modules have an internal solid state flash disk, as well as a (PID) loops and have a built-in triplex Pump Controller (float or level

micro SD memory card slot to record over 100 years of data! You can control with alternation).

retrieve and display historical data with built-in web tools and extract REDUNDANCY
trend and event data as spreadsheet files. COMBO I/O modules support redundancy for enhanced reliability. If
a module goes off-line, a designated backup can take over automati-
REPORTING
Reports can be created in minutes showing live values, production cally.

totals, trend and event data, alarm summaries, etc. Customize re-
ports with your own logos and graphics. Call up reports on demand,
or have them automatically transferred to your computer.

www.iclinks.com
Modulus COMBO (8 Universal Analog Inputs) I/O Module Specifications
FIELD I/O
Digital Inputs: 8 Optically Isolated, bipolar (AC/DC, not polarity sensitive)
I/O Range: [8x-3004, 8x-3005, 8x-3014] 0 to 30V (OFF < 6V, ON>9V), 60V absolute maximum
[81-3104, 81-3105, 81-3114] 0 to 240V (OFF < 60V, ON>90V), 300V absolute maximum
[82-3104, 82-3105, 82-3114] 0 to 120V (OFF < 60V, ON>90V), 160V absolute maximum
I/O Current: [8x-3004, 8x-3005, 8x-3014] 1.2mA @ 12V, 3mA @ 24V [8x-3104, 8x-3105, 8x-3114] 1.2mA @ 120V, 3mA @ 240V
Filtering Individually configurable: 5Hz, 10Hz, 20Hz, 50Hz, 100Hz, 500Hz, 1KHz, 2KHz+
Digital Outputs: 4 Relay contacts, Form A (normally open)
Contact Output Rating: 240/277 Vac, 30Vdc, 3A maximum per output (resistive load). Do not exceed 8A on any group of 4 outputs on a terminal block.
A snubber diode (DC) or RC snubber (AC) must be used across the relay contacts or load connections for any inductive load.
Universal Analog Inputs: 8 16-bit, Delta Sigma, individually selectable input ranges
Input Ranges: • 20mA (minimum input for full accuracy is 0.5mA)
• 5V and +/- 5V, 10V and +/- 10V, 30V
• +/- 250mV
• 50K ohms
• J, K, T, E, R,S, B, N thermocouple (ungrounded type)
• Thermistor - 2.2K, 10K (type II, II and 11.K shunt)
• 10Ω Cu RTD, 100Ω Pt RTD (2/3 wire), 1KΩ RTD (2 wire), 3-wire RTDs requires use of two analog inputs
Maximum signal level 35Vdc on any range

OPTIONAL FIELD I/O Either one of the below options can be added to the base configuration
Analog Inputs (option) 4 16-bit, Delta Sigma, individually selectable input ranges
Input Ranges: • 20mA (minimum input for full accuracy is 0.5mA)
• 5V and +/- 5V, 10V and +/- 10V, 30V
• +/- 250mV
• 65K ohms
• J, K, T, E, R,S thermocouple (ungrounded type)
• 2.2K, 10K (type II, II and 11.K shunt)
• 1KΩ RTD (2 wire)
Analog Outputs (option) 4 12-bit
Output Ranges: • 20mA
COMMUNICATIONS
Ethernet: 1 10/100mb/s (10/100 Base-T)
SCADA Protocols Modbus TCP & UDP (master/slave), Ethernet IP (master/slave), Ethernet to Serial bridging
Internet Protocols HTTP (server), FTP (server & client), ICMP (ping; server and client), NTP (client), DHCP (server & client), DNS, DDNS
Serial: 1 RS-485 (This port is available if not used for bus communications with other modules.)
1 RS-232, RS-485, RS-422, SDI-12 (This port is always available for general purpose communications.)
Baud Rates 115K, 38.4K, 19.2K, 9600, 4800, 2400, 1200 baud
Protocols Modbus RTU (master/slave), DF1 (slave), SDI-12 (general purpose port only)

HMIs
Local: 128x32 graphical, wide temperature range yellow OLED and single pushbutton
Graphical: Web based, graphic library included. Compatible with most browsers, including Internet Explorer, Firefox, Chrome, Safari, Android
Mobile: Web based, text only, up to 50 registers. Compatible with most browsers, including Internet Explorer, Firefox, Chrome, Safari, Android

PROGRAMMING
Languages: Ladder Logic, Function Block, Text—built-in web based graphical and text editor and debugger
Capacity: 32KB logic, 2MB source code

STORAGE
Registers: 504 Numeric registers, 504 Boolean registers
Internal Flash disk: 32MB
Removable disk: Micro SD Card (up to 256GB, supplied by customer)

CLOCK
Real Time Clock: Temperature compensated with 3-day super-capacitor auto-recharge backup power
o o
Stability +/- 3ppm from –30 C to 70 C

GENERAL
I/O Power: 10Vdc to 30Vdc
Power Consumption (average)
Not using Ethernet, relays OFF 18mA @ 12Vdc / 13mA @ 24Vdc (Ethernet power saver enabled)
Using Ethernet, relays OFF 78mA @ 12Vdc / 43mA @ 24Vdc
Additional current per relay ON 10mA @ 12Vdc / 5mA @ 24Vdc
Additional with AI option 10mA @ 12Vdc / 5mA @ 24Vdc
Additional with AO option Loop current from I/O power (20mA @ 12Vdc / 20mA @ 24Vdc per output used)
Field Wiring Termination: [81-3xxx] screw terminal blocks [82-3xxx] lever terminal blocks, 3.5mm, 22 to 14GA wires
Temperature: -40oC to 70oC (operating), -40oC to 85oC (storage)
Humidity: <95% RH (non-condensing)
Enclosure: Polyamide, light gray (RAL 7035)
Mounting: 35mm DIN rail with bus connector block

Specifications subject to change without notice. Consult factory to ensure that you are working with current information.

Modulus Combo I/O (8 Universal AIs) Rev A5 Copyright © 2017 Industrial Control Links, Inc. All Rights Reserved Industrial Control Links, Inc. 1364 Blue Oaks Blvd. Roseville, CA 95678 530.888.1800
Modulus COMBO (8 Universal I/Os) I/O Module DIMENSIONS and WIRING
4.1" (screw), 4.5" (lever)
0.9" Refer to the installation manual for additional installation details and precautions.
OPTICALLY ISOLATED DISCRETE INPUTS
12/24V
TB1 TB4 TB1 or TB2 TB1 or TB2 TB1 or TB2 The discrete inputs on a terminal
block share a common with only
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 the inputs on that same block
TB2 TB5
and are isolated from all other I/O
points.

4.6"
ST
TB3 TB6
“PNP” “NPN”
sensor sensor
COM DC DC

TB7
I/O AC or DC
+DC -DC +DC -DC

1 2 3 4 5
RELAY OUTPUTS
BUS The relay outputs on terminal
TB3 TB3 TB3
block 3 share a common with
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 only the other outputs on that
Terminal Function Terminal Block Inputs/Outputs same block and are isolated
1 -485 TB1 DI1 - DI4 from all other I/O points.
cathode band

2 +485 TB2 DI5 - DI8


+ A snubber diode (DC) or RC

rectifier
snubber
3 RESET# TB3 DO1 - DO4 snubber (AC) must be used
4 GND TB4 UI1 - UI4 across the relay contacts or
load connections for any induc-
5 +V TB5 UI5 - UI8 AC or DC AC or DC DC
tive load.
TB6 optional AI/AO +DC -DC

UNIVERSAL ANALOG INPUTS


TB4 or TB5 TB4 or TB5 TB4 or TB5
The analog inputs on terminal
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
blocks 4 and 5 share a common
General Purpose Communications Port TB-7 that is isolated from all other I/O
(modes are software configured) + points.

jumper
thermocouple
20mA or V “Self” Powered Sensor

20mA or V “Self” Powered Sensor

red

red
20mA Loop Powered Sensor

20mA Loop Powered Sensor

RS-232 RS-485 Note that 3-wire RTD sensors


utilize two analog inputs per

2-wire 10 ohm RTD


1 2 3 4 5 1 2 3 4 5 sensor.
thermistor

3-wire 100 ohm RTD


white
module ground

module ground

2-wire 1K ohm RTD


RS-232 Tx Out

RS-232 RTS Out

RS-485 -

RS-485 +
RS-232 Rx In

RS-232 CTS In

Ground

Ground

potentiometer

+ + + +
DC Power
(loop/sensor supply)
+DC

RS-422 SDI-12 OPTIONAL ADDITIONAL ANALOG INPUTS (TB6)


1 2 3 4 5 1 2 3 4 5 TB6 TB6
The optional analog inputs on
1 2 3 4 5 1 2 3 4 5 terminal block 6 share a common
that is isolated from all other I/O
module ground
module ground

+ points. These inputs support


SDI-12 Data
RS-422 - Out

RS-422 + Out

RS-422 + In

RS-422 - In

Ground
Ground

20mA and voltage signals, as


thermocouple
20mA or V “Self” Powered Sensor
20mA Loop Powered Sensor

well as 2-wire sensors (3-wire


RTDs are not supported).
thermistor
2-wire 1K ohm RTD

Typical RS-232 Wiring to Modem/Radio


+ +
potentiometer

TB7
DC Power
Pin 5
1 2 3 4 5 (loop/sensor supply)
Pin 1
-DC
Ground
Pin 5

Rx In
OPTIONAL ANALOG OUTPUTS (TB6)
Pin 2
RTS Out
Pin 7
Tx Out TB6
Pin 3

1 2 3 4 5
The optional analog outputs on
Pin 9 terminal block 6 share a common
Pin 6
with the module main input power.
+ + + +
The power is also utilized as the
module ground

source for analog output loop


20mA Loop Powered Device

20mA Loop Powered Device

20mA Loop Powered Device


20mA Loop Powered Device

power. Typically this is 24Vdc.

Modulus Combo I/O (8 Universal AIs) Rev A5 Copyright © 2017 Industrial Control Links, Inc. All Rights Reserved Industrial Control Links, Inc. 1364 Blue Oaks Blvd. Roseville, CA 95678 530.888.1800
www.iclinks.com
Industrial Control Links, Inc.
1364 Blue Oaks Blvd. Roseville, CA 95678
530.888.1800

You might also like