Datasheet PMT-12V50W2BA
Datasheet PMT-12V50W2BA
Datasheet PMT-12V50W2BA
PMT2
Highlights & Features
• Household appliance approvals according to IEC/EN 60335-1,
IEC/EN 61558-1 and IEC/EN 61558-2-16
• Universal AC input voltage range
• No load power consumption <0.3 W
• Low profile design : 29 mm height
• OVC III, Pollution Degree 3
• Wide operating temp -30°C ~70°C (Support -40°C cold start)
• Conforms to harmonic current IEC/EN 61000-3-2, Class A
• High MTBF > 700,000 hrs per Telcordia SR-332
• Compliance with SEMI-F47
Safety Standards
Model Information
PMT2 Panel Mount Power Supply
Model Number Input Voltage Range Rated Output Voltage Rated Output Current
PMT-12V50W2B☐☐ 90-264 Vac 12 Vdc 4.2 A
PMT-15V50W2B☐☐ 15 Vdc 3.4 A
PMT-24V50W2B☐☐ 24 Vdc 2.2 A
PMT-30V50W2B☐☐ 30 Vdc 1.7 A
PMT-36V50W2B☐☐ 36 Vdc 1.45 A
PMT-48V50W2B☐☐ 48 Vdc 1.1 A
Model Numbering
CC code
PM T– □V 50W 2 B □ □
Panel Product Type Output Voltage Output Single Phase Family Code: B Connector Type Blank – Without
Mount T – Enclosed 12 – 12 V Power with Low Profile With No PFC A – Terminal Block connector cover &
coating
15 – 15 V
B – With single side
24 – 24 V coating*1
30 – 30 V
36 – 36 V
48 – 48 V
*1 : 12 V / 24 V models only
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
1 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Specifications
*2 For power de-rating from > 50°C to 70°C, see power de-rating on page 3.
*3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. PSU need to burn in > 5 minutes
when AMB ≤ 0℃
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
2 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Mechanical
Environment
Surrounding Air Temperature Operating -30°C to +70°C (-40°C Cold Start)
Storage -40°C to +85°C
Power De-rating > 50°C de-rate power by 2% / °C
< 100 Vac de-rate power by 1.33% / V
(86.67% load @ 90 Vac)
Operating Humidity 20 to 90% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft)
Shock Test Non-Operating IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for
each 3 directions
Operating IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for
each 3 directions.
Vibration Non-Operating IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G);
20 min per axis for all X, Y, Z direction
Operating IEC 60068-2-6, Sine Wave: 20Hz to 500 Hz (5G);
10 min per cycle, 60 min for each axis (X, Y, Z)
Over Voltage Category II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Pollution Degree 3
Protections
Overvoltage 13.2 V - 17.4V 16.5 V - 21.0 V 26.4V - 33.6 V 33.0 V - 40.5 V 39.6 V - 48.6 V 52.8 V - 64.8 V
SELV Output, SELV Output, SELV Output, SELV Output, SELV Output, SELV Output,
Latch Mode Latch Mode Latch Mode Latch Mode Latch Mode Latch Mode
Overload / Overcurrent 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over Temperature Latch Mode
Hiccup Mode, Non-Latching
Short Circuit
(Auto-Recovery when the fault is removed)
Reliability Data
MTBF > 700,000 hrs as per Telcordia SR-332
I/P: 230 Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time 10 years (230 Vac, 50% load @ 40°C)
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
3 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
EMC
Emissions (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32
Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-4,
EN/BS EN 61000-6-3 : Class B
Immunity EN/BS EN 55035, KN 35
Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80 MHz – 1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
2 kV
Surge IEC 61000-4-5 Level 4 Criteria A1)
Common Mode4): 4 kV
Differential Mode5): 2 kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150 kHz – 80 MHz, 10 Vrms
Power Frequency Magnetic IEC 61000-4-8 Level 4 Criteria A1)
Fields 30 A/Meter
Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B
40% residual; 10 cycle, Criteria C3)
70% residual; 25 cycle, Criteria C3)
Harmonic Current Emission IEC/EN/BS EN Class A
61000-3-2
Voltage Sag Immunity SEMI 80% of 200 Vac 160 Vac, 1000 ms Criteria A1)
F47 – 0706 70% of 200 Vac 140 Vac, 500 ms Criteria A1)
50% of 200 Vac 100 Vac, 200 ms Criteria A1
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
4 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Block Diagram
Transformer &
Power Stage
L AC/DC Converter Vo+
& Inrush current DC/DC Output Rectifier
AC Input EMI Filter Converter DC Output
limit Filter
& Filter
N Vo-
Over Voltage
Protection
Device Descriptions
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
5 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Dimensions
L x W x H: 99 x 82 x 29 mm (3.9 x 3.23 x 1.14 inch)
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
6 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Engineering Data
Output Load De-rating VS Surrounding Air Temperature Note
1. Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1. & Fig. 2.
2. The PSU will be bouncing and start up
time will not exceed 5s when ambient
temperature at ‐30 °C
3. If the output capacity is not reduced when the
surrounding air temperature >50°C, the
device will run into Over Temperature
Protection. When activated, power supply will
latch off, until the surrounding air temperature
is lowered or the load is reduced as far as
necessary to keep the device in working
condition, and require removal/re-application
of input AC voltage in order to restart.
4. In order for the device to function in the
manner intended, it is also necessary to keep
a safety distance as recommended in the
safety instructions while the device is in
operation.
5. Depending on the surrounding air temperature
Fig. 1 De-rating for Horizontal Mounting Orientation and output load delivered by the power
> 50°C de-rate power by 2% / °C supply, the device can be very hot!
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
7 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
* If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.
• Use flexible cable (stranded or solid) of AWG No. 18-12. User should calculate and select the suitable wire specification
(type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 8 Kgf.cm. (6.94 lbf.in).
The insulation stripping length should not exceed 0.275” or 7 mm (Refer to Fig. 3).
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
8 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Only use M3 screw ≤ 3 mm (0.20 inch) through the base mounting holes.
This is to keep a safe distance between the screw and internal
components.
Recommended mounting tightening torque: 4~7 Kgf.cm. (3.47~6.08 lbf.in).
Safety Instructions
• If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further
information.
• To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50 mm (1.97 inch) from all ventilated surfaces while
the device is in operation.
• The device is not recommended to be placed on low thermal conductive surface. For example, plastics.
• The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not
touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
• Do not touch the terminals while power is being supplied. Risk of electric shock.
• Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause:
Electric shock; Safety Hazard; Fire; Product failure
• The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth
terminal on the connector be connected to the grounded surface.
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
9 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.
Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.
■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
10 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET
Others
Attention
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for
using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail
(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or
action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using
the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.
Authorized Representatives
The Netherlands United Kingdom
Delta Greentech (Netherlands) B.V. Delta Electronics Europe Limited
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 1 Redwood Court, Peel Park Campus,
East Kilbride, Glasgow, G74 5PF, United Kingdom
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
11 www.DeltaPSU.com (August 2022, Rev. 12)