Datasheet PMT-12V50W2BA

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

PMT2
Highlights & Features
• Household appliance approvals according to IEC/EN 60335-1,
IEC/EN 61558-1 and IEC/EN 61558-2-16
• Universal AC input voltage range
• No load power consumption <0.3 W
• Low profile design : 29 mm height
• OVC III, Pollution Degree 3
• Wide operating temp -30°C ~70°C (Support -40°C cold start)
• Conforms to harmonic current IEC/EN 61000-3-2, Class A
• High MTBF > 700,000 hrs per Telcordia SR-332
• Compliance with SEMI-F47

Safety Standards

CB Certified for worldwide use

Model Number: PMT-☐V50W2B☐☐


Unit Weight: 0.176 kg (0.389 lb)
Dimensions (L x W x H): 99 x 82 x 29 mm
(3.9 x 3.23 x 1.14 inch)
General Description
PMT 2nd generation (PMT2) power supplies is designed in a low 29 mm profile and accepts universal AC input. The highly efficient
convection cooling construction can operate from -30°C to 70°C. The single output model is competitively priced for general industrial
and ITE applications. It complies to major safety approvals such as IEC/EN 60335-1, IEC/EN 61558-2-16, IEC 60950-1 & IEC/EN/UL
62368-1.

Model Information
PMT2 Panel Mount Power Supply

Model Number Input Voltage Range Rated Output Voltage Rated Output Current
PMT-12V50W2B☐☐ 90-264 Vac 12 Vdc 4.2 A
PMT-15V50W2B☐☐ 15 Vdc 3.4 A
PMT-24V50W2B☐☐ 24 Vdc 2.2 A
PMT-30V50W2B☐☐ 30 Vdc 1.7 A
PMT-36V50W2B☐☐ 36 Vdc 1.45 A
PMT-48V50W2B☐☐ 48 Vdc 1.1 A

Model Numbering
CC code
PM T– □V 50W 2 B □ □
Panel Product Type Output Voltage Output Single Phase Family Code: B Connector Type Blank – Without
Mount T – Enclosed 12 – 12 V Power with Low Profile With No PFC A – Terminal Block connector cover &
coating
15 – 15 V
B – With single side
24 – 24 V coating*1
30 – 30 V
36 – 36 V
48 – 48 V
*1 : 12 V / 24 V models only

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
1 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Specifications

PMT-12V50W2B PMT-15V50W2B PMT-24V50W2B PMT-30V50W2B PMT-36V50W2B PMT-48V50W2B


Model Number
☐☐ ☐☐ ☐☐ ☐☐ ☐☐ ☐☐

Input Ratings / Characteristics

Nominal Input Voltage 100-240 Vac


Input Voltage Range 90-264 Vac
Nominal Input Frequency 50-60 Hz
Input Frequency Range 47-63 Hz
Input Current 0.95 A typ. @ 115 Vac, 0.6 A typ. @ 230 Vac
Efficiency at 100% Load @ 230Vac 85.0% typ. 87.0% typ. 88.0% typ. 88.0% typ. 89.0% typ. 88.5% typ.
No Load Power Consumption < 0.3 W@ 230 Vac
Max Inrush Current (Cold Start) 45 A typ. @ 230 Vac
Leakage Current < 0.5 mA @ 240 Vac

Output Ratings / Characteristics*2

Nominal Output Voltage 12 Vdc 15 Vdc 24 Vdc 30 Vdc 36 Vdc 48 Vdc


Factory Set Point Tolerance 12 Vdc ± 1% 15 Vdc ± 1% 24 Vdc ± 1% 30 Vdc ± 1% 36 Vdc ± 1% 48 Vdc ± 1%
Output Voltage Adjustment Range 10.8-13.2 Vdc 13.5-16.5 Vdc 21.6-26.4 Vdc 27.0-33.0 Vdc 32.4-39.6 Vdc 43.2-52.8 Vdc
Output Current 4.2 A 3.4 A 2.2 A 1.7 A 1.45 A 1.1 A
Output Power 50.4 W Max. 51 W Max. 52.8 W Max. 51 W Max. 52.2 W Max. 52.8 W Max.
Line Regulation ± 0.5% (@ 115 Vac & 230 Vac input)
Load Regulation ± 0.5% (@ 115 Vac & 230 Vac input)
PARD*3 (20MHz) < 120 mVpp @ 0°C to 70°C < 150 mVpp @ 0°C to 70°C < 200 mVpp @ 0°C to 70°C
360 mVpp typ. @ -30°C to 0°C 450 mVpp typ. @ -30°C to 0°C 600 mVpp typ. @ -30°C to 0°C

Rise Time 30 ms typ. @ 115 Vac & 230 Vac


Start-up Time 1,000 ms typ. @ 115 Vac
500 ms typ. @ 230 Vac
Hold-up Time 12 ms typ. @ 115 Vac, 60 ms typ. @ 230 Vac
Dynamic Response
± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz &
(Overshoot & Undershoot O/P
10 KHz)
Voltage)
Start-up with Capacitive Loads 8,000µF Max 8,000µF Max 8,000µF Max 470uF Max 470uF Max 470uF Max

*2 For power de-rating from > 50°C to 70°C, see power de-rating on page 3.
*3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. PSU need to burn in > 5 minutes
when AMB ≤ 0℃

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
2 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Mechanical

Case Chassis Aluminum


Case Cover SGCC
Dimensions (L x W x H) 99 x 82 x 29 mm (3.9 x 3.23 x 1.14 inch)
Unit Weight 0.176 kg (0.389 lb)
Indicator Green LED (DC OK)
Cooling System Convection
Terminal M3.5 x 5 Pins (Rated 300 V / 20 A)
Wire AWG 18-12
Current rating can refer to page6 “Wire AWG Table”
Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25 dBA

Environment
Surrounding Air Temperature Operating -30°C to +70°C (-40°C Cold Start)
Storage -40°C to +85°C
Power De-rating > 50°C de-rate power by 2% / °C
< 100 Vac de-rate power by 1.33% / V
(86.67% load @ 90 Vac)
Operating Humidity 20 to 90% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft)
Shock Test Non-Operating IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for
each 3 directions
Operating IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for
each 3 directions.
Vibration Non-Operating IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G);
20 min per axis for all X, Y, Z direction
Operating IEC 60068-2-6, Sine Wave: 20Hz to 500 Hz (5G);
10 min per cycle, 60 min for each axis (X, Y, Z)
Over Voltage Category II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Pollution Degree 3

Protections

Overvoltage 13.2 V - 17.4V 16.5 V - 21.0 V 26.4V - 33.6 V 33.0 V - 40.5 V 39.6 V - 48.6 V 52.8 V - 64.8 V
SELV Output, SELV Output, SELV Output, SELV Output, SELV Output, SELV Output,
Latch Mode Latch Mode Latch Mode Latch Mode Latch Mode Latch Mode

Overload / Overcurrent 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over Temperature Latch Mode
Hiccup Mode, Non-Latching
Short Circuit
(Auto-Recovery when the fault is removed)

Protection Against Shock Class I with PE*4 connection


*4 PE: Protection Earth

Reliability Data
MTBF > 700,000 hrs as per Telcordia SR-332
I/P: 230 Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time 10 years (230 Vac, 50% load @ 40°C)

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
3 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Safety Standards / Directives


Safety Entry Low Voltage SELV
Electrical Safety TUV Bauart EN 62368-1, EN 60335-1, EN 61558-1/-2-16
cULus UL 62368-1, and CAN/CSA C22.2 No. 62368-1
CB scheme IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16
KC K 60950-1
EAC TP TC 004/2011
BSMI CNS 14336-1
CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive
2014/35/EU
UKCA In conformance with Electromagnetic Compatibility Regulations 2016 and
Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation Input to Output 4.0 KVac
Input to Ground 2.0 KVac
Output to Ground 1.25 KVac

EMC
Emissions (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32
Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-4,
EN/BS EN 61000-6-3 : Class B
Immunity EN/BS EN 55035, KN 35
Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80 MHz – 1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
2 kV
Surge IEC 61000-4-5 Level 4 Criteria A1)
Common Mode4): 4 kV
Differential Mode5): 2 kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150 kHz – 80 MHz, 10 Vrms
Power Frequency Magnetic IEC 61000-4-8 Level 4 Criteria A1)
Fields 30 A/Meter
Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B
40% residual; 10 cycle, Criteria C3)
70% residual; 25 cycle, Criteria C3)
Harmonic Current Emission IEC/EN/BS EN Class A
61000-3-2
Voltage Sag Immunity SEMI 80% of 200 Vac 160 Vac, 1000 ms Criteria A1)
F47 – 0706 70% of 200 Vac 140 Vac, 500 ms Criteria A1)
50% of 200 Vac 100 Vac, 200 ms Criteria A1
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
4 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Block Diagram
Transformer &
Power Stage
L AC/DC Converter Vo+
& Inrush current DC/DC Output Rectifier
AC Input EMI Filter Converter DC Output
limit Filter
& Filter
N Vo-

Over Temperature PWM Control & Photo Coupler &


Protection Over Power Feedback Control
Protection

Over Voltage
Protection

Device Descriptions

1) Input & Output terminal block connector


2) DC voltage adjustment potentiometer
3) DC OK control LED (Green)

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
5 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Dimensions
L x W x H: 99 x 82 x 29 mm (3.9 x 3.23 x 1.14 inch)

Wire AWG Table

Current rating for PVC Wire AWG


6 AWG 52.5 A 20 AWG 6.5 A
8 AWG 37.5 A 22 AWG 5.0 A
10 AWG 29.0 A 24 AWG 3.5 A
12 AWG 22.5 A 26 AWG 2.5 A
14 AWG 16.5 A 28 AWG 2.0 A
16 AWG 12.0 A 30 AWG 1.5 A
18 AWG 9.0 A

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
6 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Engineering Data
Output Load De-rating VS Surrounding Air Temperature Note
1. Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1. & Fig. 2.
2. The PSU will be bouncing and start up
time will not exceed 5s when ambient
temperature at ‐30 °C
3. If the output capacity is not reduced when the
surrounding air temperature >50°C, the
device will run into Over Temperature
Protection. When activated, power supply will
latch off, until the surrounding air temperature
is lowered or the load is reduced as far as
necessary to keep the device in working
condition, and require removal/re-application
of input AC voltage in order to restart.
4. In order for the device to function in the
manner intended, it is also necessary to keep
a safety distance as recommended in the
safety instructions while the device is in
operation.
5. Depending on the surrounding air temperature
Fig. 1 De-rating for Horizontal Mounting Orientation and output load delivered by the power
> 50°C de-rate power by 2% / °C supply, the device can be very hot!

Output Load De-rating VS Input Voltage

 No output power de-rating for the input


voltage from 100 Vac to 264 Vac

Fig. 2 De-rating for AC Input Voltage


< 100 Vac de-rate power by 1.33% / V

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
7 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□
Assembly & Installation
Ⓐ Mounting holes for power supply assembly onto the mounting surface.
The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length.
Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted.
Ⓒ Connector

Base Mounting (Horizontal)

* If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.

• Use flexible cable (stranded or solid) of AWG No. 18-12. User should calculate and select the suitable wire specification
(type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 8 Kgf.cm. (6.94 lbf.in).
The insulation stripping length should not exceed 0.275” or 7 mm (Refer to Fig. 3).

Fig. 3 Assembly Reference

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
8 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

 Only use M3 screw ≤ 3 mm (0.20 inch) through the base mounting holes.
This is to keep a safe distance between the screw and internal
components.
 Recommended mounting tightening torque: 4~7 Kgf.cm. (3.47~6.08 lbf.in).

Fig. 4 Mounting Screw

Safety Instructions
• If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further
information.
• To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50 mm (1.97 inch) from all ventilated surfaces while
the device is in operation.
• The device is not recommended to be placed on low thermal conductive surface. For example, plastics.
• The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not
touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
• Do not touch the terminals while power is being supplied. Risk of electric shock.
• Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause:
Electric shock; Safety Hazard; Fire; Product failure
• The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth
terminal on the connector be connected to the grounded surface.

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
9 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□
Functions
Start-up Time
The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.

Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.

Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.

■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time

Inrush Current Dynamic Response


Inrush current is the peak, instantaneous, input current measured The power supply output voltage will remains within ± 10% of its
and, occurs when the input voltage is first applied. For AC input steady state value, when subjected to a dynamic load from 10% to
voltages, the maximum peak value of inrush current will occur 100%
during the first half cycle of the applied AC voltage. This peak value
decreases exponentially during subsequent cycles of AC voltage.

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
10 www.DeltaPSU.com (August 2022, Rev. 12)
TECHNICAL DATASHEET

PMT2 Panel Mount Power Supply


PMT2 50 W series / PMT-□V50W2B□□

Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Latch Mode)


The power supply’s Overload (OLP) and Overcurrent (OCP) The power supply’s overvoltage circuit will be activated when its
Protections will be activated when output current exceeds 110% of internal feedback circuit fails. The output voltage shall not exceed
IO (Max load). In such occurrence, the VO will start to droop and its specifications defined on under “Protections”. Power supply will
once the power supply has reached its maximum power limit, the latch, and require removal/re-application of input AC voltage in
protection is activated and the power supply will go into “Hiccup order to restart.
mode” (Auto-Recovery). The power supply will recover once the The power supply should be latch, and require removal /re-
fault condition of the OLP and OCP is removed and IO is back apply of input AC voltage in order to restart.
within the specifications.

It is not recommended to prolong the duration of Io when it is


<110% but >100%, since it may cause damage to the PSU. Over Temperature Protection (Latch Mode)
As described in Engineering data section, the power supply also
Short Circuit Protection (Auto-Recovery) has Over Temperature Protection (OTP). In the event of a higher
The power supply’s output OLP/OCP function also provides operating temperature at 100% load, the power supply will run into
protection against short circuits. When a short circuit is applied, the OTP when the operating temperature is beyond what is
output current will operate in “Hiccup mode”, as shown in the recommended in the de-rating graph. When activated, the output
illustration in the OLP/OCP section on this page. The power supply voltage will go into latch mode until the temperature drops to its
will return to normal operation after the short circuit is removed. normal operating temperature as recommended in the de-rating
graph.

Others
Attention
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for
using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail
(please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or
action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using
the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.

Manufacturer and Authorized Representatives Information


Manufacturer
Thailand Taiwan
Delta Electronics (Thailand) PCL. Delta Electronics, Inc.
909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County
32063, Taiwan

Authorized Representatives
The Netherlands United Kingdom
Delta Greentech (Netherlands) B.V. Delta Electronics Europe Limited
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 1 Redwood Court, Peel Park Campus,
East Kilbride, Glasgow, G74 5PF, United Kingdom

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
11 www.DeltaPSU.com (August 2022, Rev. 12)