This document provides an overview of DMR conventional terminal programming using Hytera's CPS software. It discusses the programming purpose, preparation needed including installing software and connecting hardware, an overview of the CPS interface and functions, and examples of configuring basic radio functions like contacts lists, channels, zones, control services, and more. The goal is to understand the steps to configure basic radio functions using CPS for DMR conventional terminal programming. The training session will last 1.5 hours and cover programming purpose, preparation, CPS overview, function configuration, and case studies.

Uploaded by

Virus Loading
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
240 views

DMR Conventional Terminal Programming

This document provides an overview of DMR conventional terminal programming using Hytera's CPS software. It discusses the programming purpose, preparation needed including installing software and connecting hardware, an overview of the CPS interface and functions, and examples of configuring basic radio functions like contacts lists, channels, zones, control services, and more. The goal is to understand the steps to configure basic radio functions using CPS for DMR conventional terminal programming. The training session will last 1.5 hours and cover programming purpose, preparation, CPS overview, function configuration, and case studies.

Uploaded by

Virus Loading
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

DMR Conventional Terminal Programming

www.hytera.com
Course Overview

1. Sales
Object
2. Technical support engineer

1. Software overview
Content 2. Basic functions configuration

Goal 1. Grasp the configuration steps of basic functions

Period: 1.5 hours


Contents

1 Programming Purpose

2 Preparation

3 CPS Overview

4 Function Configuration

5 Case Study
Programming Purpose

Factory
Settings

Why configuration is
needed?

Customer Network
Requirement Plan
Contents

1 Programming Purpose

2 Preparation

3 CPS Overview

4 Function Configuration

5 Case Study
Preparation
◼ Software

USB Driver Version


Region CPS Version
(Windows OS)
China Mainland V8.05.06.007.CHS
North America and Oceania(Australia
V8.05.06.007.NA2
& New Zealand )
Europe, Middle East and Africa V8.05.06.007.EM5 V5.30.42.0

South and Latin America V8.05.06.007.SA6


Asian (Except China mainland) V8.05.06.007.AS8
Preparation
◼ Software
Install the USB driver.
Install the CPS.
Preparation
◼ Hardware
Connect the radio to PC with programming cable.
The following are DMR programming cables:

PD7 Series X1/PD6 Series PD5 Series Mobile/Repeater


Contents

1 Programming Purpose

2 Preparation

3 CPS Overview

4 Function Configuration

5 Case Study
CPS Overview
◼ Main Interface

Menu
Toolbar
Tab View

Programming Area
Tree Bar

Help View
Status Bar
CPS Overview
◼ CPS Common Operation
CPS Overview
◼ CPS Common Operation
CPS Overview
◼ CPS Tree Introduction
Radio Information:
Display the radio's basic information.

Common:
Parameters are subject to both conventional and
other trunking mode.

Conventional:
Parameters are only subject to conventional mode.

XPT Trunking:
Parameters are only subject to XPT trunking mode.

DMR/MPT Trunking:
Parameters are only subject to DMR/MPT trunking mode.
Contents

1 Programming Purpose

2 Preparation

3 CPS Overview

4 Function Configuration

5 Case Study
Function Configuration
◼ Function Overview

Basic Configuration General Functions Common Setting

• Private Call • VOX • Power Auto Adjust


• Group Call • One Touch Call • Quick Dial
• All Call • Ctrl Services • Audio Setting
• Short Massage • Emergency Alarm • Password Setting
Function Configuration
◼ Basic Configuration
Set the radio ID.
Function Configuration
◼ Basic Configuration
Edit contact list:
Call Type - Private Call, Group Call, Alert Call, All Call.
Portable and Mobile radio can contain a maximum of 1024 members.
Function Configuration
◼ Basic Configuration
Edit RX group list:
Up to 32 group lists, each group list can add 64 members.
Function Configuration
◼ Basic Configuration
Edit channel information:
➢Set Color Code(0-15).
➢Set Slot Operation(Slot1/Slot2/Pseudo Trunk).
Function Configuration
◼ Basic Configuration
Edit channel information:
➢Set TX/RX frequency, TX contact list and RX group list.
Function Configuration
◼ Basic Configuration
Edit zone information:
Up to 64 zones, each zone can support up to 16 channels.
Function Configuration
◼ Basic Configuration
Write the configuration data to radio.
Function Configuration
◼ Basic Function-Ctrl Service
For transmitter party, check the “Encode” option to send the command.
Function Configuration
◼ Basic Function-Ctrl Service
For receive party, check the option in “Decode” to decode the command.
Function Configuration
◼ Basic Function-Emergency Service
Configure emergency system.
Function Configuration
◼ Basic Function-Emergency Service
Check the transmitter options on channel.
Function Configuration
◼ Basic Function-Emergency Service
Edit the receiver options on channel.
Alarm Indication: Set whether audio and visual indication is given when receiving.
Alarm ACK: To acknowledge an emergency alarm automatically.
Call Indication: Give an audio and visual indication when an emergency call is received.
Function Configuration
◼ Common Setting-Power Auto Adjust
Configure the power auto adjust function.
The radio automatically adjusts the transmit power based on the strength of signals received
from the repeater. This feature is available only for the radio whose "Power Level" is set to "High".
Function Configuration
◼ Common Setting-Volume
Edit the max and min volume.
Function Configuration
◼ Common Setting-Power-on Message
Edit the power on message.
Function Configuration
◼ Common Setting-Password
Edit the power on and CPS password.