990 Test Adapter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Specifications

Temperature Range
Battery
Recommended Battery
Operating 990
0 to 50EC (32 to 122EF)
Battery Life
9 V alkaline battery (NEDA 1604A)
10 hours, typical
Storage Test Adapter
-20 to 70EC (-4 to 158EF)
Note:
Battery capacity is reduced below 0EC.
Relative Humidity User Guide
5 to 90% non-condensing (operating and storage)
Battery shelf life is reduced when stored
above 40EC.
Mechanical Specifications ©1993 Bently Nevada Corporation
Width 102 mm (4.0 in) All rights reserved
Length 191 mm (7.5 in)
WARNING Height 33 mm (1.3 in)
Weight 355 g (0.78 lb) The 990 Test Adapter inverts and isolates the
PROX OUT signal from the 990 transmitter so you
Do not attempt to recharge alkaline batteries,
can connect 990 transmitters to diagnostic
store batteries near a source of high heat, or Ordering Information equipment. The adapter modifies the PROX OUT
discard batteries in fire. Doing so may cause
signal so that it matches the Bently Nevada
the batteries to leak or explode. 990 Test Adapter Package standard for Proximitor® signals by performing the
122115-01 Package includes: Test Adapter, following operations:
9V Battery, AC Adapter, Power
AC Adapter Cord, User Guide, and Soft ! shifts the phase of the PROX OUT signal by 180E
Output Voltage Carrying Case. and changes the voltage from positive to negative
9.0 Vdc ± 5% (regulated for 0 to 100 mA)
Center Conductor Spare Parts ! isolates the transmitter from diagnostic
Positive 01810700 Battery (9 volt alkaline) equipment so that grounded equipment will not
Power Cord Input Connector 02270056 AC Adapter (universal AC input to 9 affect the transmitter's 4-20 mA loop
3 conductor, IEC 320 male type volts)
Input Voltage Options 02198937 Power Cord (for USA AC power The 990 Test Adapter includes the following
120 Vac @ 60 Hz, nominal or 220 or 240 Vac outlet) features:
@ 50 Hz, nominal 123133-01 User Guide
04160101 Soft Carrying Case ! small size and weight for portable operation
Inputs
Connector Type Female BNC type Accessories ! battery or AC adapter power options
Input Impedance 1 MS, nominal 123266-01 Coaxial Cable Kit (4 cables, 5 feet
Input Voltage Range 1.0 to 16.75 volts each) ! auto shutoff circuit that powers the unit down
02211505 Single Coaxial Cable (1 cable, 5 when the battery is low
Outputs feet)
Connector Type Female BNC type
! two channels, so orbits can be displayed for XY
Output Impedance 50 S, nominal
probe configurations
Minimum Resistive Load 10 kS
Maximum Cable Length 305 metres (1000 feet)
Frequency Response 0 to 10 kHz, -5%
Short Circuit Duration Indefinite
Part Number 123133-01
Revision NC
Battery voltage too low.
Replace battery.

POWER ON LED not lit when using AC adapter


power
Input voltage switch on AC adapter in
wrong position.
Check input voltage switch.

AC adapter not connected properly.


Check connections at AC adapter jack,
power cord input, and AC power outlet.

Output signal seems to be in error


Test adapter does not have power.
Check POWER ON LED.

Input or output cable not connected


Connecting the Inputs and Outputs properly.
Operation Use coaxial cables as shown in the above figure. Check input and output connections.
The test adapter can be connected to grounded,
AC-powered test equipment (oscilloscope, DVF, 990 Test Adapter not functioning
WARNING ADRE®, etc.) or to battery-powered or ungrounded correctly.
test equipment (portable signal analyzer, DMM, Run Verification Test.
etc.).
Contact with rotating machinery can cause
severe injury. Test and Verification
Be careful. Keep safe distance.
CAUTION Required equipment: function generator,
Using Battery Power oscilloscope, and three coaxial cables.
Put on/off switch in the ON position. The POWER 1. Set the function generator for a 1 kHz sine wave
Connecting the 990 Test Adapter to a with a 1 V pp amplitude and +6 Vdc offset.
ON LED comes on to indicate that the test adapter
continuous monitoring system could result in 2. Connect the function generator to the test
is ready for use.
false alarms and/or incorrect monitor adapter input using a coaxial cable.
readings. 3. Connect the oscilloscope to the test adapter
Using AC Adapter Power
Since the AC adapter is designed for universal AC input and output using coaxial cables.
input, configure the adapter for your AC power Troubleshooting 4. Display both the input and output signals on the
outlet. First, put the input voltage switch on the AC oscilloscope
adapter in the correct position. Make sure that you Problem Cause/Solution 5. Verify that the output signal is the mirror image of
have the appropriate power cord for your AC power POWER ON LED not lit when using battery power the input signal.
outlet. On/off switch not in ON position.
Check switch.
Connect the AC adapter to the AC ADAPTER jack
and the AC power outlet as shown in the above AC adapter connected but not used.
figure. The POWER ON LED comes on to indicate Disconnect AC adapter.
that the test adapter is ready for use.
Battery not connected properly.
Check battery connection.