Kone Step Chain
Kone Step Chain
Kone Step Chain
Maintenance Instructions
Suggested maintenance schedule for Step chain Module is one to six times per year,
dependent upon escalator use.
7-002057 (2010-02)
The pulse length and delay between pulses (for automatic oiler) are set by operational
parameters in the controller.
Pulse length (lubrication pump on time)
• Set operational parameter 19 (MINUTES) to 00.
• Set operational parameter 20 (SECONDS) to 02.
Delay between pulses (lubrication pump off time)
Delay between pulses is dependent on rise and whether the escalator is indoors or outdoors.
NOTE! Values below are starting point values for an INDOOR escalator with a vertical rise of
4.5 m. Parameters must be checked after first maintenance is completed and
adjusted accordingly.
NOTE! Values for escalators that are OUTDOORS and with different vertical rises may be
different.
• Set operational parameter 21 (HOURS) to 01.
• Set operational parameter 22 (MINUTES) to 10.
• Set operational parameter 23 (SECONDS) to 00.
707-183 (2002-10)
If required, the step chain lip track may be moistened by a spray in the running surface area.
7-002058 (2009-10)
7-002065 (2009-10)
7-002055 (2009-10)
Reduction dimension
Chain type Reduction dimension
16HDV 5 mm
22HDV 6.5 mm
30HDV 8 mm
5025314 (2011-05)
6
7
4
8
7
1
2 H
3
5
5025314(2011-05)