Catalogo Pulsateria Omron
Catalogo Pulsateria Omron
Catalogo Pulsateria Omron
Pushbutton Switches
A22NN/A22NL
Button Colors
Red Green Yellow White Blue Black
A22NN-
-N
Opaque
Non-lighted
Switches Red Green Yellow White Blue Orange
A22NN-
-U
Transparent
Lighted A22NL-
-T
Switches Transparent Opaque
Red Green Yellow White Blue Orange
white*
When lit
* The colors when the Switches are lit are for transparent white buttons (code: TW) and yellow LED Lamps (code: Y).
1
A22NN/A22NL
List of Models
Plastic bezels Brushed metal bezels Metal bezels
A22N
-BN A22N
-MN A22N
-RN
Flat Flat Flat
A22N
-BG A22N
-MG
Full guard Full guard
2
A22NN/A22NL
Model Number Structure
Model Number Legend - - - - - Shipped as a set that includes the Operation Unit, LED Lamp, Mounting Collar, and Contact Block.
For information on combinations, refer to Ordering Information on pages 4 to 7.
■ Specifications: Refer to page 15. ■ Precautions for correct use: Refer to page 23.
■ Dimensions: Refer to page 17. ■ Accessories and tools: Refer to page 13.
3
A22NN/A22NL
Ordering Information
Model Numbers for Sets - - - - Shipped as a set that includes the Operation Unit, LED Lamp, Mounting Collar, and Contact Block.
Note: Normally, the Button and LED Lamp with the same color are combined.
However, opaque white is available by combining a white Button and yellow LED. A22N
-
-TWA-G
-Y
■ Subassemblies: Refer to pages 8 to 12. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
(You can order Operation Units, LED Lamps, Mounting Collars, and ■ Accessories and tools: Refer to page 13.
Contact Blocks individually.)
4
A22NN/A22NL
Ordering Information
Model Numbers for Sets - - - Shipped as a set that includes the Operation Unit, LED Lamp, Mounting Collar, and Contact Block.
Note: Normally, the Button and LED Lamp with the same color are combined.
However, opaque white is available by combining a white Button and yellow LED. A22N
-
-TWA-G
-Y
■ Subassemblies: Refer to pages 8 to 12. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
(You can order Operation Units, LED Lamps, Mounting Collars, and ■ Accessories and tools: Refer to page 13.
Contact Blocks individually.)
5
A22NN/A22NL
Ordering Information
Model Numbers for Sets - - - Shipped as a set that includes the Operation Unit, LED Lamp, Mounting Collar, and Contact Block.
Note: Normally, the Button and LED Lamp with the same color are combined.
However, opaque white is available by combining a white Button and yellow LED. A22N
-
-TWA-G
-Y
■ Subassemblies: Refer to pages 8 to 12. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
(You can order Operation Units, LED Lamps, Mounting Collars, and ■ Accessories and tools: Refer to page 13.
Contact Blocks individually.)
6
A22NN/A22NL
Ordering Information
Model Numbers for Sets - - - Shipped as a set that includes the Operation Unit, LED Lamp, Mounting Collar, and Contact Block.
Note: Normally, the Button and LED Lamp with the same color are combined.
However, opaque white is available by combining a white Button and yellow LED. A22N
-
-TWA-G
-Y
■ Subassemblies: Refer to pages 8 to 12. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
(You can order Operation Units, LED Lamps, Mounting Collars, and ■ Accessories and tools: Refer to page 13.
Contact Blocks individually.)
7
A22NN/A22NL
Ordering Information
Switch Structure - - - - You can order Operation Units, LED Lamp, Mounting Collars, and Contact Blocks individually. Use them in
combination for models that are not available as assembled Switches. They can also be used as inventory for
maintenance parts.
Plastic Operation Units Brushed Metal Operation Units Metal Operation Units
Lighted models
Non-lighted
models
Reinforcement Plate
■ Model numbers of sets: Refer to pages 4 to 7. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
■ Accessories and tools: Refer to page 13.
8
A22NN/A22NL
Ordering Information
Subassemblies - - - - -You can order Operation Units, LED Lamps, Mounting Collars, and Contact Blocks individually. Use them in
combination for models that are not available as assembled Switches. They can also be used as inventory for
maintenance parts.
Operation Units
Plastic, flat Plastic, projected
■ Model numbers of sets: Refer to pages 4 to 7. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
■ Accessories and tools: Refer to page 13.
9
A22NN/A22NL
Ordering Information
Subassemblies - - - - - You can order Operation Units, LED Lamps, Mounting Collars, and Contact Blocks individually. Use them in
combination for models that are not available as assembled Switches. They can also be used as inventory for
maintenance parts.
■ Model numbers of sets: Refer to pages 4 to 7. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
■ Accessories and tools: Refer to page 13.
10
A22NN/A22NL
Ordering Information
Subassemblies - - - - -You can order Operation Units, LED Lamps, Mounting Collars, and Contact Blocks individually. Use them in
combination for models that are not available as assembled Switches. They can also be used as inventory for
maintenance parts.
Metal, mushroom
■ Model numbers of sets: Refer to pages 4 to 7. ■ Specifications: Refer to page 15.■ Dimensions: Refer to page 17.
■ Accessories and tools: Refer to page 13.
11
A22NN/A22NL
Ordering Information
Subassemblies - - - You can order Operation Units, LED Lamps, Mounting Collars, and Contact Blocks individually. Use them in
combination for models that are not available as assembled Switches. They can also be used as inventory for
maintenance parts.
LED Lamps
Applied voltage 6 VAC/DC 12 VAC/DC 24 VAC/DC 100/110/120 VAC 200/220/230/240 VAC
Appearance
Color Model Model Model Model Model
Red A22NZ-L-RA A22NZ-L-RB A22NZ-L-RC A22NZ-L-RD A22NZ-L-RE
Green A22NZ-L-GA A22NZ-L-GB A22NZ-L-GC A22NZ-L-GD A22NZ-L-GE
Yellow A22NZ-L-YA A22NZ-L-YB A22NZ-L-YC A22NZ-L-YD A22NZ-L-YE
White A22NZ-L-WA A22NZ-L-WB A22NZ-L-WC A22NZ-L-WD A22NZ-L-WE
Blue A22NZ-L-AA A22NZ-L-AB A22NZ-L-AC A22NZ-L-AD A22NZ-L-AE
Mounting Collar
Appearance Model
A22NZ-H-01
Contact Blocks
Appearance Contacts Model
Lighting Units
Appearance Applied voltage Model
6 VAC/DC A22NZ-T-A
12 VAC/DC A22NZ-T-B
24 VAC/DC A22NZ-T-C
100/110/120 VAC A22NZ-T-D
200/220/230/240 VAC A22NZ-T-E
Reinforcement Plate
Appearance Model
A22NZ-A-C01
12
A22NN/A22NL
Ordering Information
Accessories and Tools (Order Separately)
Item Appearance Classification Model Remarks
13
A22NN/A22NL
A22Z-3443B Black
A22Z-3443R Red
Without text
A22Z-3443W White
A22Z-3443C Transparent
A22Z-3443R-2
White text on red background
STOP A22Z-3443R-4
--- A22Z-3443B-1
Small Legend Plates
START A22Z-3443B-3
ON A22Z-3443B-5
OFF A22Z-3443B-6 Legend Plate with white text on
black background included.
UP A22Z-3443B-7 For 22.3-mm panel hole diameter.
DOWN A22Z-3443B-8
POWER ON A22Z-3443B-9
OFF-ON A22Z-3443B-10
A22Z-3453B Black
A22Z-3453R Red
Large Legend Plates Without text
A22Z-3453W White
A22Z-3453C Transparent
14
A22NN/A22NL
Specifications
Certified Safety Standard Ratings
UL 508 (File No. E76675), CSA C22.2 No.14
6 A 240 VAC, 10 A 120 VAC
TÜV (EN60947-5-1)
AC-15 3 A 240 VAC
DC-13 4 A 24 VDC
CCC (GB14048.5)
AC-15 3 A 240 VAC
DC-13 4 A 24 VDC
Ratings
Contacts (Standard Load)
Rated insulation voltage 600 V
Rated carry current 10 A
Applied voltage 24 V 120 V 240 V 380 V 440 V
AC at 50/60 Resistive load (AC-12) 10 A 10 A 6A 2A 2A
Hz Inductive load (AC-15) 10 A 6A 3A 1.9 A 1.6 A
Resistive load (DC-12) 8A 2.2 A 1.1 A --- ---
DC
Inductive load (DC-13) 4A 1.1 A 0.55 A --- ---
Note: 1. The above ratings were obtained by conducting tests under the following conditions.
(1) Ambient temperature: 20 ±2°C
(2) Ambient humidity: 65% ±5% RH
(3) Operating frequency: 30 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC.
LED Lamps
Rated voltage Applied voltage Rated current
Approx. 11 mA (red, orange, yellow, or blue)
6 VAC/DC 6 VAC/DC ±10%
Approx. 5 mA (white or green)
Approx. 12 mA (red, orange, yellow, or blue)
12 VAC/DC 12 VAC/DC ±10%
Approx. 5 mA (white or green)
Approx. 12 mA (red, orange, yellow, or blue)
24 VAC/DC 24 VAC/DC ±10%
Approx. 5 mA (white or green)
100 VAC 100 VAC ±10%
110 VAC 110 VAC ±10% Approx. 2 mA
120 VAC 100 to 130 VAC
200 VAC 200 VAC ±10%
220 VAC 220 VAC ±10%
Approx. 2 mA
230 VAC 230 VAC ±10%
240 VAC 220 to 250 VAC
15
A22NN/A22NL
Specifications
Characteristics
Type Pushbutton Switches
Item Non-lighted models Lighted models
Allowable operating Mechanical 60 operations/minute max.
frequency Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. (initial value)
Between terminals of same polarity 2,500 VAC at 50/60 Hz for 1 min
Dielectric strength
Between each terminal and ground 2,500 VAC at 50/60 Hz for 1 min
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Shock resistance Malfunction 1,000 m/s2 max. (malfunction within 1 ms)
Momentary action: 5,000,000 operations min.
Mechanical
Durability Alternate action: 500,000 operations min.
Electrical 500,000 operations min.
Ambient operating temperature*1 −25 to 70°C −25 to 55°C
Ambient operating humidity 35% to 85% RH
Ambient storage temperature*1 −40 to 80°C
Degree of protection*2 IP66, NEMA 4X, NEMA13
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination (application environment) 3 (IEC 60947-5-1)
Pushbutton Switches
Momentary Alternate
Lighted Non-lighted Lighted Non-lighted
Linking example
Operation Unit
Mounting Collar
Note: If you increase the number of Contact Blocks, evaluate the Switch under actual working conditions before permanent installation and use
the Switch within a number of switching operations that will not adversely affect the Switch’s performance.
16
A22NN/A22NL
Dimensions (Unit: mm)
5
0.5 0.5
5 1.8
6
30 1.8 45.3
13.5
11 45.3
28.8 dia.
23.3 dia. 43.5
11
19.1 45.3
11
19.1 45.3
40 dia. 43.5
11
20.7 45.3
17
A22NN/A22NL
Dimensions (Unit: mm)
5
0.5
1.8
11
30 45.3 13.5 45.3
28.8 dia.
43.5
23.3 dia.
11
19.1 45.3
11
19.1 45.3
40 dia. 43.5
11
20.7 45.3
18
A22NN/A22NL
Dimensions (Unit: mm)
5
0.5
1.8
11
30 45.3 13.5
45.3
28.8 dia.
43.5
23.3 dia.
11
19.1 45.3
40 dia. 43.5
11
20.7 45.3
45.3
66.8
20 20
1 3 3 1 X1 3
X
LED
Lamp
Six, M3.5
Six, M3.5
Phillips/slotted Phillips/slotted 2 4 4 2 X2 4
screws screws
Contact Blocks
19
A22NN/A22NL
Dimensions (Unit: mm)
24.3 30
9.8 dia.
9 dia.
17.1
51.3
29.6
22.2 32.2
29.6
47 9.9
47 9.9
Reinforcement Plate
A22NZ-A-C01
12.1
29.8
3.6
20
A22NN/A22NL
Dimensions (Unit: mm)
Dimensions of Accessories
Tightening Wrench LED Extractor
A22NZ-A-301 A22NZ-A-302
3-dia. hole
2.8
14 dia. 10 dia.
28 dia.
59
2.5
107.5
25 dia.
133
8 dia.
30 3.50
14 16
7
15
Control Box
Four, M4 Phillips Four, 3.7-dia,
A22NZ-A-B01Y binding screws 40 M4-tapped holes
Cover (yellow) Case (black)
24.2 22.3 dia. 10 Two, 14-dia.
Two, 21.4-dia bottom lead holes
side lead holes Two, 4.4-dia
oval mounting holes
24.2 80 62
3.2
18.5
3.2 5.4
10
80 38 40
59.9
Lock Ring
A22NZ-A-50501
29
1.8
1
29
21
A22NN/A22NL
Dimensions (Unit: mm)
0.9
40 0.9
50
20.6
20.6
Legend Plates
Small A22Z-3443@-@ Large A22Z-3453@
1 26.8 1
26.8
8.2
17.9
5 dia.
23.4 20.5
1
22
A22NN/A22NL
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches/Indicators.
X1
R: 10 kΩ (1 W)
bleeder resistor
LED
Lamp
X2
23
A22NN/A22NL
Application
Mounting to the Panel
Panel Hole Dimensions Dimension B
• Panel hole dimensions are given below. Operation Unit shape Dimension B
• The recommended panel thicknesses are given below. Mushroom 40 mm min.
Panel hole dimension Panel thickness Other than the above 30 mm min.
24.1 +0.4
0 dia.
Mounting Nut
Using the Lock Ring Standard Switch
Rubber washer Projecting part
25.5 dia.
• Align the Lock Ring with the slot on the case and insert it so that
the edge is flush with the panel.
Note: The minimum mounting pitch is based on three Contact Blocks (1)
in stage 1 with one wire attached to each terminal.
TOP mark
If you attach two wires or link Units, determine the mounting
pitch based on the dimensions diagrams and ease of operation
and wiring.
Dimension A When Using Accessory (2)
• Dimension A is 50 mm minimum when a Standard Legend Plate
Frame is attached.
• Dimension A is 51 mm minimum when a Large Legend Plate
Frame is attached.
• Dimension A is 75 mm minimum when a Protective Cover is
attached.
24
A22NN/A22NL
(2)
(1)
(1)
(2)
(3)
(3)
(1)
(1)
(2)
Engraving
• Engrave legends on the Legend Plates.
Do so with the straight part of the Legend Plate positioned on the
right and left.
• The characters must be engraved no deeper than 0.5 mm. Use an
alcohol-based paint, such as a melamine, phthalic acid, or acrylic
resin based paint.
25
A22NN/A22NL
Display range
15.4 dia.
Legend
Plate di- Attaching and Replacing LED Lamps
1.6
mensions 5.15 Removing the LED Lamp from the Panel Surface
• Insert the LED Lamp Extractor as shown in the following figure and
Projected,
Full-guard, or 15.9 dia.
then rotate the Extractor in the direction shown at (2) while
Mushroom pressing it inward.
Switches
17.1 0−0.2 dia.
T = 0.1 to 0.2 mm
Display range
Attaching the LED Lamp from the Panel Surface
17.7 dia.
Legend • Insert the LED Lamp into the LED Lamp Extractor as shown in the
Plate di- following figure. Align the projections on the LED Lamp with the
mensions LED Lamp insertion guides, insert the LED Lamp, and turn it in the
1.30
direction indicted at (2).
2.00
(2)
Flat Switches
19.6 0−0.2 dia. (1)
Film dimen-
sions
17.5 0−0.2
T = 0.1 to 0.2 mm
LED Lamp insertion guides
26
A22NN/A22NL
Operation
Unit
Rubber washer (built
into the Operation Unit)
Screwdriver • Align the TOP mark on the Operation Unit, part A on the Legend
Side Plate, and the notch in the panel, and insert the Operation Unit.
Switch Box Cover
Part A
TOP mark
Cable hole
Strike at four
diagonally
opposed locations
Groove to open the hole.
Attaching and Removing Legend Plates
• Press the Legend Plate into the depression in the Legend Plate Legend Plate
Frame. The Legend Plate Frame can be separate or it can be Panel thickness: 0.8 to 4 mm
mounted on the panel when you attach the Legend Plate.
• The direction of the characters will depend on the mounting • If there is no notch in the panel, remove part A from the Legend
direction of the Operation Unit if the Switch is a Selector Switch or Plate with pliers.
Key Selector Switch.
Part A
Depression
27
MEMO
28
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. © OMRON Corporation 2015 All Rights Reserved.
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, In the interest of product improvement,
Alexandra Technopark, 200 Yin Cheng Zhong Road, specifications are subject to change without notice.
Singapore 119967 PuDong New Area, Shanghai, 200120, China
Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Cat. No. A239-E1-01 0415 (0415)