GENERAL NOTES :--


B1(9"x23") B1(9"x23") 1. Use M20(1:2:4) grade for slab, beams & footings
M25(as per desigen mix) for columns.
2. Use FE415 grade tor steel.
300' 300' 3. S.B.C OF the soil is taken as per soil report

300

300
500 kn/msq
4. Provide clear cover of 40mm for columns ,
B3(9"x23")

B3(9"x23")
50mm for footings.

B4(9"x23")
5. Provide clear cover of 25mm for beams ,
15mm for slab .
6. Footings are desigen for 24.50 m ht
B2(9"x23") B2(9"x23") 7.Read horizontal beams from left to right &
vertical from bottom to left.

8.crank +ve bars at L/4 th of span & extend -ve


bars L/5 th of span.
9.Do not over lap bottom rods at center and top

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


rods at support.
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

300' 300' 10.Slab thickness 150 slab.

300

300
11.lap length 48 D ( D-dia of the bar)
in compression
12.lap length 52 D ( D-dia of the bar) in tension

B1(9"x23") B1(9"x23") 13. Desigend for earth quake load IS 1893-2002


& seismic zone -3
14. Desigend for wind load IS 875 (part 3)-1987.
PLAN 15. Fill loose pockets with p.c.c (1:2:4)
16. Don't Scale the drawing.

NOTE :- Refer flour milling consultant dra.


for cut -out details and same information.
8"

PROJECT NAME:
SCALE: N.T.S

DATE 6-1-2023
PROPOSED SRI JAGGANATH ROLLER
DRAWN MUSTAFA FLOUR MILL , KHURDA .
DESIGNED SANISH

CHECKED DATTATREYA TITLE:


REV. No.

KULKARNI CONSULTANT'S
STRUCTURAL (st)RUCTURAL ENGINEERS, ARCHITECTS & PROJECT CONSULTANT'S
CONSULTANTS: #216, KUBERA TOWER'S, NARAYAN GUDA,HYDERABAD.
CONTACT NO'S:- 04023223891, 09246343724, 09246343720.
EMAIL:- kulku_kcons@yahoo.com