Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Schematic GC-PW PSU

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

1 2 3 4 5

D1
1N4001

A A
U5 TL783
R72
5R6 +48V
3 IN OUT 2

1 ADJ
R70

1N4001
BR2 240R

220uF

220uF

220uF

220uF

100nF

220uF
DC+

2.2uF
KBP310

C39

C38

C40

C41

C46

C47
U7

D2
U3

330nF
AC AC
R65
100nF

U6
47k
T1
R71

DC-
VTT2326 RP1 10k
50K

110V ac 44V ac
B AGND B
220V ac

1
D3
1N4001

IC 7824 R73
1R +24V
110V ac 28V ac
1 VI VO 3

GND
R74

2
BR1 1R
1000uF

1000uF

1000uF

1000uF

100nF
DC+

KBP310
C42

C43

C44

C45

U9
U4
AC AC D4 Q11
330nF 1N4003 BC550
DC-

C LED C

Analog Ground
AGND AGND
100nF
U11

R75
1R

Chassis Ground
Mains Safety Earth
CGND
D D

TITLE:
GC-73 Alim REV: 2.0

Company: G.C. AUDIO Sheet: 1/1


Date: 2020-05-25 Drawn By: G.C.
1 2 3 4 5
220-240v Transformer Wiring
IEC Connector Mains Switch
(Ideally “Filtered”) DPDT

Fuse/Holder
Live Brown
White
Earth
Neutral Violet White
Red
Grey

Chassis Stud
Red
Blue

Green/Yellow

PCB “Mains Chassis Earth” Connection

100-120v Transformer Wiring


IEC Connector Mains Switch
(Ideally “Filtered”) DPDT

Fuse/Holder
Live Brown
White
Earth
Neutral Violet White
Red
Grey
Chassis Stud

Red
Blue

Green/Yellow

PCB “Mains Chassis Earth” Connection


GC-PW Transfo Connection

M4 Shakeproof Washer

M4 x 16mm screw
GC-PW Calibration / Setup

Power Up;

Measure the voltage under J3, +24V pad ( the “DC Feeds” spade terminals)

You should read +24 volts

Phantom Voltage Setting;

Measure the voltage under J3, +48V pad ( the “DC Feeds” spade terminals)

Adjust R9 until you read +48 volts