Code: 15A02603 R15
B.Tech III Year II Semester (R15) Supplementary Examinations December/January 2018/19
POWER SYSTEM ANALYSIS
(Electrical & Electronics Engineering)
Time: 3 hours Max. Marks: 70
PART – A
(Compulsory Question)
*****
1 Answer the following: (10 X 02 = 20 Marks)
(a) Define Cut set and Tie set.
(b) Define primitive network.
(c) Write the equation for the bus admittance matrix.
(d) List the various types of shunt and series faults.
(e) What is the need for load flow study?
(f) What is the need for slack bus?
(g) List the quantities specified and the quantities to be determined from load flow study for various types of
buses.
(h) How the convergence of N-R method is speeded up?
(i) Define swing curve. What is the use of swing curve?
(j) Give the expression for critical clearing time.
PART – B
(Answer all five units, 5 X 10 = 50 Marks)
UNIT – I
2 (a) Derive the formula for Zbus using building algorithm if the element is a branch with mutual coupled to
om
other element.
r.c
(b) Describe the procedure for modifications of Zbus when a line with mutual impedance is added.
OR
ke
3 Determine the incidence matrices A, A1, B, B1, C, C1 and K. From that verify the following relations for
an
shown in figure below, take 1 as reference bus: (i) Cb = -BLT. (ii) AbKT = U.
tR
3 4
irs
.F
w
w
1 2
w
www.FirstRanker.com
Page 1 of 2
www.FirstRanker.com www.FirstRanker.com
Code: 15A02603 R15
UNIT – III
6 (a) Explain the necessity of power flow studies in power system and list out the power flow methods.
(b) Explain computation of losses and injected power (real and reactive power) in a load flow study and
derive its equations.
OR
7 (a) Write short notes on data for power flow studies.
(b) Write an algorithm for Gauss Seidel load flow method when P-V buses are present.
UNIT – IV
8 (a) Formulate the N-R load flow problem with respect to rectangular form. Explain its solution..
(b) Writ the advantages and disadvantages of N-R method over Gauss Seidel method.
OR
9 (a) With neat flow chart, explain the computational procedure for load flow solution using fast decoupled
method when the system contains all types of buses.
(b) What is Jacobian matrix? How the elements of Jacobian matrix are computed?
UNIT – V
10 (a) Explain the classical methods for improving power system stability.
(b) A 20 MVA, 50 Hz generator delivers 20 MW over a double circuit line to an infinite bus. The generator
has kinetic energy of 2.52 MJ/MVA at rated speed. The generator transient reactance is Xd = 0.30 pu.
Each transmission circuit has R = 0 and a reactance of 0.2 pu on a 20 MVA base. E’ = 1.1 pu and infinite
bus voltage V = 1 pu. A three phase short circuit occurs at the midpoint of one of the transmission lines.
plot swing curves with fault cleared by simultaneous opening of breakers at both ends of the line at
2.5 cycles.
OR
om
11 (a) Explain equal area criterion with respect to stability with neat sketch.
(b) Explain critical clearing time and critical clearing angle by deriving its expressions.