Instruction manual

0 Instruction Manual Electrobloc EBL 99 G

Electrobloc EBL 99 G
Type no. 911.417

Table of contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3 Description and appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . 3

4 Suitable accessories (not supplied) . . . . . . . . . . . . . . . . . . . . . . . . 4

5 Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

8 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

9 Changing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

10 Technical faults, possible causes and remedies . . . . . . . . . . . . . . 9

11 Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

12 Block diagram - for specialist workshop only . . . . . . . . . . . . . . . . 11

13 Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

© 2005 Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de

SDT-0054-00EN Situation: 15.06.2005


Instruction Manual Electrobloc EBL 99 G

1 Introduction
This instruction manual contains important information for safe operation of
the Electrobloc. It is essential to read and to follow the given safety informa-
tion.
The instruction manual should always be kept in the motorhome/caravan. All
safety information must be passed on to other users.

W Failure to comply with this sign may lead to the endangerment of per-
sons.

W Failure to comply with this sign may damage the device or the connected
consumers.

W This sign indicates recommendations or special features.

The reproduction, translation and duplication of this manual, even in parts, is


not allowed without written authorization.

2 Safety information
The design of the Electrobloc is state-of-the-art and according to approved
safety technology. Nevertheless, if the safety information in this instruction
manual is not closely followed, persons might get injured or the Electrobloc
might be damaged.
Do not use the Electrobloc if it is not in technically good order and condition.
The instruction manual must be followed.
Any technical faults affecting the safety of persons or of the Electrobloc must
be dealt with immediately by qualified personnel.

W The electrical system of the motorhome or the caravan has to meet


current DIN, VDE and ISO regulations. Manipulations of the electrical
system will endanger the safety of persons and the vehicle, and are
therefore prohibited.
W Never make any modifications to the Electrobloc.
W The electrical connection may only be established by qualified person-
nel and must be carried out according to the Schaudt installation
instructions.
W Connection work is to be carried out in tensionless condition only.
W Risk of fatal injury due to electric shock or fire in the case of a defective
mains cable or incorrect connection!
W Risk of fatal injury!
Never perform maintenance on the Electrobloc when it is live.
W Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
W Never bridge or repair fuses.
W Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
W Only use original fuses rated as specified in the instruction manual.

2 Situation: 15.06.2005 SDT-0054-00EN


Instruction Manual Electrobloc EBL 99 G

W Danger of burning! During operation the back of the Electrobloc gets


hot. Do not touch.
W Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Elec-
trobloc or an excessively high battery working temperature (more than
30 °C).

W The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.
W An incorrectly set battery selector switch damages the living area battery.
W Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
W If the living area battery is separated from the Electrobloc using the 12 V
main switch at the control and switch panel, the frost protection valve of
the heater system opens. Water may be lost. For more information, see
the instruction manual of the heater system.
W Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
W Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solarzelle" (+ Solar Module) on the solar charge regulator.
W To avoid voltage peaks during warm-up, do not connect the generator until
it is running in a stable manner. Otherwise, the Electrobloc, the 12 V con-
sumers or other connected equipment might get damaged. It is essential
that the generator complies with the mains supply specifications.
W The mains supply on board car ferries might not always be perfect. There-
fore, never connect the Electrobloc to the mains on car ferries. Otherwise,
the Electrobloc, the 12 V consumers or other connected equipment might
get damaged.

3 Description and appropriate use


The Electrobloc EBL 99 G is designed as a main power distributor for
motorhomes/caravans. The Electrobloc is a permanent installation. The Elec-
trobloc is for charging batteries and supplying 12 V appliances with power.
The electrical management system Electrobloc EBL 99 G consists of:
P The LAS 1218 charger module
P The 12 V distribution
P Fuses for the 12 V circuits
P A battery monitor module
P Other control and monitoring functions
The charger module is a primary controlled switch-mode power supply. This
modern switching technology achieves high charging performance at a com-
pact size and low weight.
A control and switch panel has to be connected for operation. This control and
switch panel controls the electrical functions in the living area of in the
motorhome, including accessories.

SDT-0054-00EN Situation: 15.06.2005 3


Instruction Manual Electrobloc EBL 99 G

There are connections for an auxiliary charging unit and a solar charge regu-
lator.

1 2 3 4 5 6 7 8 9 10

12 11 SDT00266

Fig. 1 Electrobloc EBL 99 G, front view


1 Mains connection
2 Connections for refrigerator
3 Connections for refrigerator power supply, D+ and sensor/control wires
4 Connections for frost protection valve, heater and floor light/step
5 Connections for control and switch panel
6 Spare connections
7 Connections for solar charge regulator
8 Connections for auxiliary charging unit
9 Connections for TV, pump and other consumers
10 Battery selector switch
11 Flat vehicle fuses
12 Battery cut-off switch

4 Suitable accessories (not supplied)

Control and switch panel P IT 20-2, IT 20-3, IT 95, IT 901, IT 991, IT 992, IT 993
P LT 410, LT 99, LT 993
and their variants

Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current
Additional 2-pin charging cable, lengths supplied on request

Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur-
rent of 14 A with 3-pin connector plug, including 0.5 m cable

5 Electrical data
Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I
Suitable batteries 6-cell lead acid or lead gel batteries of at least 55 Ah
Current-carrying capacity 12 V outputs No more than 90 % of the rated current
of the appropriate fuse may be drawn,
see the block diagram.

4 Situation: 15.06.2005 SDT-0054-00EN


Instruction Manual Electrobloc EBL 99 G

6 Operation
6.1 Operating controls

Flat vehicle fuses


W Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
W Never bridge or repair fuses.
W Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
W Only use original fuses rated as specified in the instruction manual.

The flat vehicle fuses protect the various circuits.

Battery cut-off switch The battery cut-off switch "Batterie Ein/Aus" (battery on/off) disconnects the
following connections from the living area battery:
P All 12 V consumers
P The frost protection valve
P The control and switch panel
This prevents the living area battery from slowly discharging due to closed cir-
cuit current while the vehicle is not in use.
The batteries can still be charged using the Electrobloc, the alternator, an
auxiliary charging unit or the solar charge regulator, even when the battery
cut-off switch is switched off.

W Before starting up:


P Make sure the living area battery is connected.
P Make sure the battery selector switch is set for the correct type of bat-
tery.
P Make sure the AES fuse is only used if the AES refrigerator is connect-
ed. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.

Start up the system „ Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery
on).
„ After switching on the battery cut-off switch or after changing batteries:
Switch on the 12 V main switch on the control and switch panel briefly to
start up the consumers.

Shutting down the system „ Set the battery cut-off switch to "Batterie Aus" (battery off).

W When the living area battery is separated from the Electrobloc by the bat-
tery cut-off switch, the frost protection valve of the heater system opens.
Water may be lost. For more information, see the instruction manual of the
heater system.

SDT-0054-00EN Situation: 15.06.2005 5


Instruction Manual Electrobloc EBL 99 G

Battery selector switch

W Danger of explosion from formation of detonating gas due to an incor-


rectly set battery selector switch, defective batteries, defective Electro-
bloc or an excessively high battery working temperature (more than
30 °C).

W An incorrectly set battery selector switch damages the living area battery.
W Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.

The switching option provided by the battery selector switch ensures optimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
Use a thin object (e. g. a ballpoint pen cartridge) to move the battery selector
switch.
„ Set lead gel battery: Set the battery selector switch to "Blei-Gel" (lead gel).
„ Set lead acid battery: Set the battery selector switch to "Blei-Säure" (lead
acid).

12 V main switch (on the The 12 V main switch on the control and switch panel switches all consumers
control and switch panel) and the panel on and off.
Exceptions:
P Heater
P Floor light/step
P Frost protection valve
P AES/compressor refrigerator
P Spare 4
For more information, see the instruction manual of the control and switch
panel.

6.2 Additional functions


Automatic switch function 7KLVUHOD\VXSSOLHVWKH$(6FRPSUHVVRUUHIULJHUDWRUZLWKSRZHUIURPWKH
for AES/compressor VWDUWHUEDWWHU\ZKHQWKHYHKLFOHHQJLQHLVUXQQLQJDQGWKH'FRQQHFWLRQLV
refrigerator OLYHAn AES/compressor refrigerator is powered by the living area battery
when the vehicle engine is switched off.

Mains charging of starter This feature provides an automatic float charge for the starter battery at up to
battery 2 A when the 230 V mains is connected to the Electrobloc.

6 Situation: 15.06.2005 SDT-0054-00EN


Instruction Manual Electrobloc EBL 99 G

6.3 Battery monitor

Automatic disconnector The battery monitor compares the voltage of the living area battery to a refer-
ence voltage. As soon as the battery voltage falls below 10.5 V, all 12 V con-
sumers are switched off via the main switch relays 1 and 2. Only the frost pro-
tection valve is still powered. The automatic disconnector is not triggered by
short-term low voltage (less than 2 seconds), caused by high current when
switching on consumers.
If an overload or an insufficiently charged living area battery causes the volt-
age to fall so low that the automatic disconnector is triggered, any consumers
which are not essential should be switched off.
You may be able to switch on the 12 V power supply for a short time. To do
this, switch on the 12 V main switch on the control and switch panel.
However, if the battery voltage remains below 11.0 V, you cannot switch the
12 V power supply back on.
Fully charge up the living area battery as soon as possible. For more informa-
tion see the description of battery voltage.

7 Maintenance
The Electrobloc requires no maintenance.

Cleaning Clean the Electrobloc with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances.
Do not allow fluid to penetrate the inside of the Electrobloc.

8 Shutting down the system


W Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
W Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solarzelle" (+ Solar Module) on the solar charge regulator.

W When the living area battery is separated from the Electrobloc by the bat-
tery cut-off switch, the frost protection valve of the heater system opens.
Water may be lost. For more information, see the instruction manual of the
heater system.

Disconnecting the living Disconnect the living area battery from the 12 V power supply if you are not
area battery from the 12 V going to use the motorhome for a lengthy period (for example during the
power supply winter).
„ Switch off the 12 V main switch on the control and switch panel.
„ Set the battery cut-off switch on the Electrobloc to "Batterie Aus" (battery
off).
„ Remove the plug "+ Solarzelle" (+ Solar Module) on the solar charge reg-
ulator, if the battery is going to be removed.
„ Pull out the fuse for the AES refrigerator.

SDT-0054-00EN Situation: 15.06.2005 7


Instruction Manual Electrobloc EBL 99 G

W The living area battery can also be charged using the internal charger
module, an auxiliary charging unit, the solar charge regulator and the alter-
nator when the battery cut-off switch is switched off.

9 Changing the battery


W Batteries may only be changed by qualified personnel.
W Follow the instructions of the battery manufacturer.
W To disconnect the battery from the Electrobloc, all you need to do is set the
battery cut-off switch on the Electrobloc to "Batterie Aus" (battery off).
W Charging unsuitable types of battery may irreparably damage them.
W Only use the Electrobloc for connecting the 12 V power supply to 6-cell
lead gel or lead acid batteries.

Only use batteries of the same type and capacity and those installed by the
manufacturer.
You can change from lead acid to lead gel batteries.
You cannot change from lead gel to lead acid batteries. Ask your dealer for
advice.

W Danger of explosion from formation of detonating gas due to an incor-


rectly set battery selector switch, defective batteries, defective Electro-
bloc or an excessively high battery working temperature (more than
30 °C).

W An incorrectly set battery selector switch damages the living area battery.
W Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.

The switching option provided by the battery selector switch ensures optimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
Use a thin object (e. g. a ballpoint pen cartridge) to move the battery selector
switch.
„ Set lead gel battery: Set the battery selector switch to "Blei-Gel" (lead gel).
„ Set lead acid battery: Set the battery selector switch to "Blei-Säure" (lead
acid).

Starting up the system „ Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery
on).
„ After switching on the battery cut-off switch or after changing batteries:
Switch on the 12 V main switch on the control and switch panel briefly to
start up the consumers.

8 Situation: 15.06.2005 SDT-0054-00EN


Instruction Manual Electrobloc EBL 99 G

10 Technical faults, possible causes and remedies


If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, e. g. if you are abroad, you can have the Electrobloc
repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.

Fault Possible cause Remedy


Living area battery is not No mains voltage Switch on the automatic
charged during 230 V fuse in the vehicle
operation (battery voltage
Have the mains voltage
constantly below 13.3 V)
checked
Defective Electrobloc Call customer service
Living area battery is over- Defective Electrobloc Call customer service
charged during 230 V
operation (battery voltage
constantly above 14.5 V)
Starter battery is not No mains voltage Switch on the automatic
charged during 230 V fuse in the vehicle
operation (battery voltage
Have the mains voltage
constantly below 13.0 V)
checked
Defective Electrobloc Call customer service
Living area battery is not Defective alternator Have the alternator
charged during mobile checked
operation (battery voltage
No voltage at D+ input Have the fuse and wiring
below 13.0 V)
checked
Defective Electrobloc Call customer service
The living area battery is Defective alternator Have the alternator
overcharged during mobile checked
operation (battery voltage
constantly above 14.3 V)
The refrigerator does not No power supply to the Have the fuse and wiring
work during mobile opera- refrigerator checked
tion
Defective Electrobloc Call customer service
Defective refrigerator Have the refrigerator
checked
Solar charger does not Solar charge regulator not Plug in the solar charge
work (power supply and plugged in regulator
engine are off)
Defective fuse or wiring Have the fuse and wiring
checked
Defective solar charge reg- Have the solar charge reg-
ulator ulator checked

SDT-0054-00EN Situation: 15.06.2005 9


Instruction Manual Electrobloc EBL 99 G

Fault Possible cause Remedy


12 V power supply in the 12 V main switch for the liv- Switch on the 12 V main
living area does not work ing area battery is switch for the living area
switched off battery
Battery cut-off switch is Switch on the battery cut-
switched off off switch
Defective fuse or wiring Have the fuse and wiring
checked
Defective Electrobloc Call customer service

W If the device becomes too hot due to excessive ambient temperature or


lack of ventilation, the charging current is automatically reduced. However,
always prevent the device from overheating.
W If the automatic shutdown mechanism of the battery monitor is triggered,
fully charge up the living area battery.

11 Customer service
Customer service address Schaudt GmbH, Elektrotechnik & Apparatebau
Daimlerstraße 5
88677 Markdorf
Germany
Phone: +49 7544 9577-16
Email: kundendienst@schaudt-gmbh.de
Opening hours Mon to Thu 8 to 12 a.m., 1 to 4 p.m.
Fri 8 to 12 a.m.

Sending in the device Returning a defective device:


„ Always use well-padded packaging.
„ Fill in and enclose the fault report, see section 13.
„ Send it to the addressee delivered free.

Disposal instruction When the product service life is over, dispose of the device in accordance with
the applicable regulations.

10 Situation: 15.06.2005 SDT-0054-00EN


Instruction Manual Electrobloc EBL 99 G

12 Block diagram - for specialist workshop only

&KDUJLQJUHOD\
6%

01/VRFNHWFDS[EORFN

$X[LOLDU\FKDUJLQJXQLW
1HJDWLYHFKDUJLQJXQLW
0DLQV9a+]VRFNHW
6ZLWFKEHWZHHQ
OHDGJHO %DWWHU\FXWRIIUHOD\
OHDGDFLG
7KHQHJDWLYHSROHRIWKHOLYLQJDUHDEDWWHU\PXVWEH
0DLQVZLWFKUHOD\$ 0DLQVZLWFKUHOD\$ FRQQHFWHGH[WHUQDOO\WRWKHQHJDWLYH SROHRI
WKH VWDUWHU EDWWHU\

6%  EDWW
6KXQW /$%  EDWW
1HJDWLYH/$%
05SLQFDS[EORFN

0DLQVLQGLFDWRU
6KXQWEDWWHU\
6KXQWFRQVXPHU
9RQ
9RII
9LQGLFDWRU
1HJDWLYHVHQVRU/$%  EDWW
6HQVRU/$%  EDWW
6%  EDWW
5HIULJHUDWRUUHOD\ 1RWDVVLJQHG
%DWWHU\FXWRIIVZLWFK 2II
1RWDVVLJQHG
1RWDVVLJQHG

&LUFXLWERDUG.3/(%/D
7\SHQR
5HIULJHUDWRUUHOD\ 01/VRFNHWFDS[EORFN

01/VRFNHWFDS[EORFN 6HQVRU/$% HDFK


PPð
1HJDWLYHVHQVRU/$% PD[P
)URVWSURWHFWLRQYDOYH $ 6% IRUUHIULJHUDWRU
+HDWHU 'LQSXW
$ 1HJDWLYH6% IRUUHIULJHUDWRU

)ORRUOLJKW 01/VRFNHWFDS[EORFN
VWHS
&RPSUHVVRU$(6UHIULJHUDWRU
01/VRFNHWFDS[EORFN $EVRUEHUUHIULJHUDWRU
$ 'EDVH
6RODUFKDUJH 1HJDWLYHUHIULJHUDWRU
UHJXODWRU
/5 6  01/VRFNHWFDS[EORFN
/$% OLYLQJDUHDEDWWHU\
01/VRFNHWFDS[EORFN 6% VWDUWHUEDWWHU\
79 
 5HIULJHUDWRUOLQHVPXVWEHOHDGWRWKH
6RODUPRGXOH EDWWHU\SROHVZLWKRXWEHLQJFRQQHFWHGWR
RQO\IRU/5 3XPS RWKHUEDWWHU\VXSSOLHV
PD[$

&LUFXLW
6SDUH
&LUFXLW
PD[$ PD[$
6SDUH
6SDUH PD[$
6SDUH
PD[$ PD[$

6SDUH 6SDUH

1RWDVVLJQHG

SDT00233

Fig. 2 Block diagram of Electrobloc EBL 99 G

SDT-0054-00EN Situation: 15.06.2005 11


Instruction Manual Electrobloc EBL 99 G

13 Fault report
In the event of damage, please return the defective device together with the
completed fault report.
Device type: EBL 99 G
Type no.: 911.417

There is the following defect:


(please tick)
Battery not
being charged
during power
operation
Battery not
being charged
during mobile
operation
The following
electrical con-
sumers do not
work:
Malfunction of
control and Tank Voltage Current
switch panel
Constant fault
Temporary
fault/loose con-
tact

Other remarks:

12 Situation: 15.06.2005 SDT-0054-00EN