Furuno Sat-C Mnual
Furuno Sat-C Mnual
Furuno Sat-C Mnual
FELCOM 15
Installation Manual
TABLE OF CONTENTS
SAFETY INSTRUCTIONS .............................................................................................................i
EQUIPMENT LISTS......................................................................................................................ii
SYSTEM CONFIGURATION .......................................................................................................iv
1. MOUNTING THE UNIT..........................................................................................................1
1.1 Antenna Unit.................................................................................................................1
1.2 Terminal Unit ................................................................................................................4
1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306 ........................................6
1.4 Printer PP-510 (option)/EGC Printer PP-505 (option) ..................................................7
1.5 AC/DC Power Supply Unit PR-240 (option) .................................................................7
1.6 Junction Box IC-315 .....................................................................................................8
2. WIRING .................................................................................................................................9
2.1 Antenna Cable Connector at the Terminal Unit..........................................................10
2.2 Distress Alert/Received Call Unit IC-305....................................................................13
2.3 Alarm Unit IC-306 .......................................................................................................14
2.4 Junction Box IC-315 ...................................................................................................15
3. INITIAL SETTING................................................................................................................16
3.1 Setting the IMN (INMARSAT MOBILE NO.)...............................................................16
3.2 Setting for External Equipment...................................................................................17
4. INSTALLATION OF GPS BOARD (OPTION).....................................................................18
5. CHANGING POWER SUPPLY SPECIFICATIONS ............................................................21
PACKING LISTS....................................................................................................................... A-1
OUTLINE DRAWINGS.............................................................................................................. D-1
INTERCONNECTION DIAGRAM ............................................................................................. S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
The paper used in this manual
is elemental chlorine free.
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax : +81-(0)798-65-4200
WARNING CAUTION
Do not open the equipment
Confirm that the power supply voltage
unless totally familiar with
is compatible with the voltage rating
electrical circuits and
of the equipment.
service manual.
Connection to the wrong power supply
ELECTRICAL Only qualified personnel can cause fire or equipment damage. The
SHOCK should work inside the
voltage rating appears on the label at the
HAZARD equipment.
rear of the terminal unit.
i
EQUIPMENT LISTS
Standard Supply
Name Type Code No. Qty Remarks
Antenna Unit IC-115 - 1
Terminal Unit IC-215 - 1
Distress Alert/
IC-305 - 1
Received Call Unit
Alarm Unit IC-306 - 1
Junction Box IC-315 - 1 w/CP16-02501*
CP16-02101 004-439-060 For 30 m antenna cable (w/o armor)*
CP16-05001 001-101-960 For 30 m antenna cable (w/armor)*
1 set
CP16-02111 004-439-070 For 50 m antenna cable (w/armor)*
CP16-02121 004-439-080 For 100 m antenna cable (w/armor)*
CP16-02301 (for IC-215)*,
Installation CP16-02300 000-043-433 1 set
CP16-02302 (for keyboard)*
Materials
CP16-02201 004-438-890 1 set For IC-305/306
TP5FBAW-5DFB 000-159-523-11 30 m antenna cable (w/o armor)
5D-FB-CV-NP 000-173-676-10 30 m antenna cable (w/armor)
1
8D-FB-CV 000-168-241-10 50 m antenna cable (w/armor)
12D-SFA-CV 000-138-866 100 m antenna cable (w/armor)
Accessories FP16-00600 1 set Mini keyboard (G84-4100PPAUS), FD
000-043-434
(FP16-00601)
Spare Parts SP16-01301 004-439-370 1 set Fuse*
Optional Supply
Name Type Code No. Qty Remarks
FD-ROM 16-5-0164 004-438-920 1 set
GPS Board OP16-47 001-017-110 1 set
GPS Board Kit OP16-48 000-011-766 1 set
RF Cover (GPS) OP16-49 000-011-767 1
EGC Printer PP-505 - 1
Printer PP-510 - 1 w/CP16-01200*
AC/DC Power Supply Unit PR-240 - 1 w/CP24-00151*
000-560-452 For junction box, 10m
000-103-868 For junction box, 20m
CO-SPEVV-SB-C
5-pair cable 000-103-869 1 For junction box, 30m
0.2x5P
000-132-829 For junction box, 40m
000-132-828 For junction box, 50m
IC-307 (2units), FD-ROM (for
SSAS Modification Kit** OP16-33 000-043-492 1
RFCON CPU, for TERM CPU)
SSAS Alert Unit** IC-307 000-043-473 1 w/CP16-03101, FP16-00901
For distress alert/received call
OP16-27 004-448-000 1
Flush Mounting Kit unit, alarm unit
OP16-28 004-448-010 1 For SSAS alert unit
ALC (FFA) Modification Kit* OP16-26 004-439-840 1
Russian Language Kit OP16-43 004-449-590 1 For IC-215
PC Terminal Software OP16-45 004-449-600 1 Russian Language
Antenna Mounting Kit CP16-03701 004-555-000 1 set
ii
Antenna Bracket CP16-03702 001-016-260 1 See page D-14.
Antenna Mounting Pipe CP16-03703 001-014-510 1
*: See packing lists at the back of this manual.
**: The SSAS modification kit is required for the SSAS. For installation of three IC-307s, additional SSAS
alert unit is necessary.
iii
SYSTEM CONFIGURATION
ANTENNA
UNIT
IC-115
DGPS
Printer**
PP-510
* For 12 VDC power supply,
DC-DC converter is Mini Keyboard Distress Alert/
required to use PP-510.
Received Call Unit
IC-305
Distress Message Controller
24 VDC DMC-5 JUNCTION
BOX Alarm Unit
OR
IC-315 IC-306
SSAS Alert Unit* SSAS Alert Unit*
IC-307 IC-307
Navigator
(Max. 3 units)
Unit Category
Terminal Unit Protected from weather
Antenna Unit Exposed to weather
Other Units Protected from weather
iv
1. MOUNTING THE UNIT
NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to coating
or plastic parts of the equipment.
Those items contain organic solvents that can damage coating and plastic
parts, especially plastic connectors.
5 5 15 15
INSTALLTION
ZONE
PROHIBITED
2m ZONE
1.5 m
15
2m
5m
S-band radar
HORIZONTAL LINE
S-band radar and installation area
1
1. MOUNTING THE UNIT
• The allowable vibration level as specified by Inmarsat is as shown in the table below.
Allowable vibration level
Frequency Level
2 to 10 Hz 2.54 mm Peak Amplitude
10 to 100 Hz 9.8 m/s² Peak Acceleration
• Avoid the location near funnels and stacks; smoke and soot on the radome can lower
signal level.
• Separate the antenna unit 5 m from HF, VHF or 27 MHz antenna.
Mounting
The antenna cable is available in lengths of 30 m, 50 m and 100 m (see table below).
Cable length Type Remarks
30 m (no armor) TP5FBAW-5DFB TNC connector at both ends
30 m (w/armor) 5D-FB-CV-NP
50 m (w/armor) 8D-FB-CV N connector on one end (antenna side)
100 m (w/armor) 12D-SFA-CV
To mount the antenna unit, an exclusive pipe is necessary.
Note 1: Do not shorten these cables. Interference can result, affecting performance.
Note 2: To mount the antenna unit with the optional antenna mounting kit (Type:
CP16-03701, Code No.: 004-555-000), see page D-13.
Locally prepare an antenna mast with a ground stud (M6 stainless steel bolt welded to
antenna mast) and mounting pipe with threads and plate (See the outline drawing of the
mounting plate shown on the next page.) Weld the mounting pipe to the antenna mast.
The distance between the stud and the earth terminal on the antenna unit should be within
340 mm, which also is the length of the supplied earth wire.
2
1. MOUNTING THE UNIT
12-S
20
1x14 UNS
200
Earth wire (340 mm)
100
Ground stud
Mounting pipe
Antenna mast
6
.4
25
Mounting pipe and antenna mast
For how to wire the antenna cable, see "Installation and Replacement of Antenna Unit",
included with the antenna unit.
3
1. MOUNTING THE UNIT
Mounting
Tabletop mounting
1. Fix the hanger on a table with four tapping screws (5x20, supplied).
282
240 + 0.5
4-φ7
80 + 0.5
29 + 3
Flush mounting
Use local supplied pan head screws (M4x20) when the thickness of the bulkhead is from 11
to 14 mm. For bulkhead which exceeds 14 mm in thickness the length of the pan head
screws should be bulkhead thickness A +7.8±2 mm. Also the length of B should be max. 8
mm (B≤8 mm).
B A
1. Prepare a cutout in the mounting location whose dimensions are as shown on next
page.
2. Fix the display unit by six pan head screws M4x20, inserting from the inside of the
bulkhead. Refer to the outline drawing at the end of this manual.
4
1. MOUNTING THE UNIT
38 80 120
M4x20
228±0.5
223±1
230±0.5
4.5
273±1 4-R2.25
58
Dimensions for flush mounting
Keyboard
15
1. Attach the function key label ( INM-C 12 ) to the location shown below.
Function key label (supplied)
_ I
! @ # $ % ^ & ( ) + Home
Back-
1 2 3 4 5 6 7 7 8 8 9 9 0 - = space
Q W E R T Y U I O P { } Pg Up
Tab 4 5 5 6 - [ ] \
Caps A S D F G H J K L : " Pg Dn
Lock Enter
1 2 3 ; + ' Enter
5
1. MOUNTING THE UNIT
ALARM ALARM
ACK ACK
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the bottom chassis to the mounting location with four tapping screws (supplied).
3. Cable can be entered from bottom or rear panel. Select suitable entrance. For rear
panel entrance, change the clamp orientation as follows.
a) Unfasten two screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten two screws removed at step a) to fix the clamp.
Unfasten these screws.
Refasten screws.
Rotate.
Flush mounting
The optional flush mounting kit OP16-27 (Code No. 004-448-000) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-4201-1 100-317-841 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-162-605-10 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied as the option kit).
3. Fasten four tapping screws (ø5, supplied as the option kit) to mount the fixture to the
mounting position.
6
1. MOUNTING THE UNIT
Label for
200 Compass safety distance
405
Printer PP-510
PP-505 (option)
1. Fix the hanger on a table with four tapping screws.
2. Screw knobs into printer.
3. Set printer to hanger and tighten knobs.
272 + 1
100 + 1
7
1. MOUNTING THE UNIT
1. Remove four screws from the unit to separate the bottom chassis from the top chassis.
2. Fix the bottom chassis to the mounting location with four tapping screws (4x16:
supplied).
3. Connect the cables appropriately referring to Chapter 2.
120 + 0.5
70 + 0.5
8
2. WIRING
24 VDC
VCTF-0.75x3C
(5 m)
Printer
For cable w/armor PP-510
0.34 m
Cable Assy.
Ground wire
TPA5FB0.4NJ5FBA-5DFB
TP5FBAW-5DFB,
5D-FB-CV-NP, 30 m 30 m (No armor)
8D-FB-CV, 50 m Connector at both 16S0184,
12D-SFA-CV, 100 m ends 3m
Connector at one end
Mini keyboard
TNCP-NJ G84-4100PPAUS
connector DGPS
(Supplied)
LAN cable
Connector N-P-5DFB (10BaseT, local supply)
N-P-8DFB Remove the cover to use.
N-P-12DSFA
(Supplied, local arrangement)
Copper strap
MJ-A3SPF0018-050Z
1.2 m
Wiring of FELCOM 15
9
2. WIRING
Center Pin Set the center pin to the core and solder
the pin from the hole in the pin.
(Pull the pin with approx. 1 kg of force to
check strength of solder joint.)
- Be sure the solder is flush with surface of
Solder here.
pin.
- Be sure there is no gap between center
pin and insulator. Do not push the center
pin into the insulator.
- Do the soldering as quickly as possible so
as not to deform the insulator.
Insulator Ring
Shell
10
2. WIRING
8D-FB-CV (50 m)
Outer Sheath Dimensions in millimeters.
Armor Inner Sheath Shield Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
50 30 dimensions shown left.
30 10
1
Expose the insulator by 1 mm.
5
Expose the insulator by 5 mm.
Pin
Clamp Nut Slip the pin onto the conductor. Solder them
Shell
together through the hole on the pin.
11
2. WIRING
12D-SFA-CV (100 m)
1.8
Expose the insulator by 1.8 mm.
12
2. WIRING
Shield
Vinyl sheath
Conductor
(Twisted pair)
2
S =1.25 mm
=1.35 mm Painting
(Sectional view)
16P0213
For CO-SPEVV-
SB-C 0.2x5P 1 2 3 4 5
13
2. WIRING
16P0213 JP2
JP1
14
2. WIRING
For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable
(Japan Industrial Standards) TTYCS-4 or equivalent. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with IC-315.
1 Vcc
IC-305/306
2 GND
3 TD/RD-A
4 TD/RD-B
Cover 5 NC
6 TD-A(NAV) 1
7 TD-B(NAV) 2
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
Cable clamp 12 DMC OUT-C
13 DMC IN-H
14 DMC IN-C 3 Core 7 mm
15 DMC CTR
Terminal
board Sticker for
To terminal unit
connection of
other equipment
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
15
3. INITIAL SETTINGS
3.1 Setting the IMN (INMARSAT MOBILE NO.)
After the wiring, set your IMN (Inmarsat Mobile No.) as below.
Setup
1. Distress Alert Setup
2. System Setup
3. Editor Setup
4. Terminal Setup
5. EGC Setup
6. Auto Mode Setup
7. E-Mail Setup
8. Directories
9. Configuration
Setup menu
3. Press [2] key to display the System Setup menu.
Setup
System Setup
System Date & Time 01:53 02-02-25 (YY-MM-DD)
IMN
MES Operation Mode INMARSAT-C
Nav Port OFF
Active Port INT
Message Output Port INT
EGC Output Port INT
9.Network
Configuration
Setup
Command Window
To clear the IMN, press [I] [M] [N] in order while pressing the [Alt] key down at step 5.
16
3. INITIAL SETTINGS
7. Press the number key for unit not connected, and then press the [Enter] key.
For example, press the [1] and [Enter] keys when the DMC-5 is not connected.
[ DMC ]
1. ON
2. OFF E: Exit
Enter No.:
17
4. INSTALLATION OF GPS BOARD
(OPTION)
This chapter provides the procedure for the installation of the GPS board (in the terminal
unit), which provides GPS position information.
* * *
*: Remove
18
4. INSTALLATION OF GPS BOARD (OPTION)
2. Unfasten four pan head screws (M3x8) to remove the RF cover (S).
3. Fasten three pan head screws (M3x8, supplied with the kit) to attach the GPS board to
the RF cover.
4. Attach the 7P connector from the RF cover to the JI on the GPS board.
Cable
#
#
RF cover
J1
Grommet
Fix the cable with the clamp. less than 2.94N (300gf)
19
4. INSTALLATION OF GPS BOARD (OPTION)
a
b
7. Reassemble the terminal unit as below.
a) Fasten six spacers ○a by hand tentatively.
b) Fasten eight pan head screws ○b tightly.
c) Fasten six spacers ○a by box driver tightly.
d) Fasten other screws and washers to complete. b b
20
5. CHANGING POWER SUPPLY
SPECIFICATIONS
The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s
mains. If the ship’s mains is 100 VAC-115 VAC, change the tap connection and terminal
board connection as below. Attach a label supplied as accessories to the front panel
according to the ship’s mains.
Ship’s mains Tap connection Terminal board Label
200-230 VAC 2.2-1.7 A
200-230 VAC SEL 230 V Below (a)
1φ 50/60 Hz
100-115 VAC 3.2-2.6 A
100-115 VAC SEL 115 V Below (b)
1φ 50/60 Hz
Remove screw
and cover.
Cover
Front panel
(a) 200-230 VAC
Relay
1 Black Coil
2 Grey 3
J4 2
3 1
1 SEL
Terminal board 2 115V
3 Heat sink
4 SEL
(b) 100-115 VAC 5 230V
6
1 Black 7
8
2 Grey
3
Tap connection
(Pull out to disconnect.)
Front panel
Attach appropriate label.
AC Power Switch
(When connecting DC input, note that the DC power is supplied
even though this switch is turned off.)
21
IC-215-J*/IC-215-E* 16AK-X-9851 -6 1/1
PACKING LIST
NAME OUTLINE DESCRIPTION/CODE № Q'TY NAME OUTLINE DESCRIPTION/CODE № Q'TY
機器引渡し前の注意 C52-00201-* ワ/エイ
ユニット UNIT 1
BEFORE DELIVERING TO OWNER
ターミナルユニット 000-809-353-1*
IC-215* 1
TERMINAL UNIT 取扱説明書 OM*-56350-*
**
1
000-043-432-00 OPERATOR'S MANUAL
000-809-348-1* **
予備品 SPARE PARTS SP16-01301
取扱説明書 OM*-56351-* 1
予備品 SP16-01301 (IC-215用) OPERATOR'S MANUAL
1 **
SPARE PARTS 000-150-358-1*
004-439-370-00 装備要領書 IM*-56350-* 1
付属品 ACCESSORIES FP16-00600 INSTALLATION MANUAL
000-809-350-1* **
フロッピーディスク組品 FP16-00601
遭難通信要領 TIC-56350-* ワ/エイ
1 1
FLOPPY DISK DISTRESS COMMUNICATION
004-439-400-00 000-809-352-1*
ミニキーボード G84-4100PPAUS 1
KEYBOARD
000-172-018-10
図書 DOCUMENT
アプリケーションフォ-ム J5-950010-* ワ/エイ 1
REGISTRATION FOR SERVICE
ACTIVATION 000-807-330-1*
ヒューズ変更のお願い C52-00206-* 1
NOTICE FOR FUSE REPLACEMENT
000-147-004-1*
1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL
A-1
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
C5635-Z01-D
#-: #-:
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
A-2 A-3
+% +%
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
࡙࠾࠶࠻ 70+6 ࡙࠾࠶࠻ 70+6
ㆣ㔍⼊ႎེ ⌕ାᜰ␜ེ
+% +%
&+564'55#.'4670+6 #.#4/70+6
Ꮏ᧚ᢱ +056#..#6+10/#6'4+#.5 %2 Ꮏ᧚ᢱ +056#..#6+10/#6'4+#.5 %2
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
:575 :575
5'.(6#22+0)5%4'9 5'.(6#22+0)5%4'9
⌕┵ሶ ⌕┵ሶ
(8
.( (8
.(
%4+/210.7) %4+/210.7)
⌕┵ሶ ⌕┵ሶ
(8 (8
%4+/210.7) %4+/210.7)
࿑ᦠ &1%7/'06
+%ᒁ߈ᷰߒ೨ߩᵈᗧ
%
$'(14'&'.+8'4+0)61190'4
㪈㪅㩿㪁㪈䋩䈱䋪䋪䋪䋪䈲䇮䉍䊶ή䈚䈱᭽䈏䉍䉁䈜䇯
㪘㪭㪘㪠㪣㪘㪙㪣㪜㩷㪮㪠㪫㪟㩷㪦㪩㩷㪮㪠㪫㪟㪦㪬㪫㩷㪁㪁㪁㪁㪁㩷㪬㪥㪠㪫㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%<% %<%
A-4 A-5
Ꮏ᧚ᢱ Ꮏ᧚ᢱ
+%
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㩃㨺㩖㩨㩣⚵ຠ ㆬᛯޓޓޓޓޓޓޓ 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
ޓ61$'5'.'%6'&
&5(#%8/ 㩂㩥ޓ//
%#$.'#55; +057.#6+105.''8'
%1&'01 %1&'01
㨻㩧㩍㩏㩃㨺㩖㩨㩣⚵ຠ ㆬᛯޓޓޓޓޓޓޓ 㩃㨺㩖㩨㩣⼔᧚
ޓ61$'5'.'%6'&
&($%8/ 41*5
%#$.'#55; %#$.'2416'%6+10
%1&'01 /#6'4+#. %1&'01
㩃㨺㩖㩨㩣⚵ຠ ㆬᛯޓޓޓޓޓޓޓ 㩄㩧㩗㩨㨹㩂㩇
ޓ61$'5'.'%6'&
62($#9&($/ %8$
%#$.'#55; %#$.'6+'
%1&'01 %1&'01
หゲ㩃㨺㩖㩨㩣 ㆬᛯޓޓޓޓޓޓޓ 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
ޓ61$'5'.'%6'&
&($%802/ 01
#4/174'&%1#:+#.%#$.' 5'.($10&+0)6#2'
%1&'01 %1&'01
㩃㨺㩖㩨㩣⚵ຠ 49
49
%#$.'#55;
%1&'01
㩃㩚㩆㨺㩣
59㨻㩣㩚㩋㨷㨺㩖㩨)
5+.+%1047$$'4
%1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
%/' %/-
A-6 A-7
Ꮏ᧚ᢱ Ꮏ᧚ᢱ
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
㩂㩥ޓ// 㩂㩥ޓ//
+057.#6+105.''8' +057.#6+105.''8'
%1&'01 %1&'01
㩃㨺㩖㩨㩣⼔᧚ 㩃㨺㩖㩨㩣⼔᧚
41*5 41*5
%#$.'2416'%6+10 %#$.'2416'%6+10
/#6'4+#. %1&'01 /#6'4+#. %1&'01
㩄㩧㩗㩨㨹㩂㩇 㩄㩧㩗㩨㨹㩂㩇
%8$ %8$
%#$.'6+' %#$.'6+'
%1&'01 %1&'01
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
01 01
5'.($10&+0)6#2' 5'.($10&+0)6#2'
%1&'01 %1&'01
㩄㩒㩂㩊
0 㩄㩒㩂㩊
0
02&($%( 052&5(#%(
%1#:+#.%100'%6140 %100'%614
6;2' %1&'01 %1&'01
㩃㨺㩖㩨㩣⚵ຠ 49 㩃㨺㩖㩨㩣⚵ຠ 49
49 49
%#$.'#55; %#$.'#55;
%1&'01 %1&'01
㩃㩚㩆㨺㩣 㩃㩚㩆㨺㩣
59㨻㩣㩚㩋㨷㨺㩖㩨) 59㨻㩣㩚㩋㨷㨺㩖㩨)
5+.+%1047$$'4 5+.+%1047$$'4
%1&'01 %1&'01
㩄㩒㩂㩊
60%0 㩄㩒㩂㩊
60%0
60%20, 60%20,
%1#:+#.%100'%614 %1#:+#.%100'%614
#ਸ਼ %1&'01 #ਸ਼ %1&'01
㩃㨺㩖㩨㩣⚵ຠ 㩃㨺㩖㩨㩣⚵ຠ
62#($10,($#&($ 62#($10,($#&($
%#$.'#55'/$.; %#$.'#55'/$.;
%1&'01 %1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
%/. %/.
A-8 A-9
Ꮏ᧚ᢱ Ꮏ᧚ᢱ
+%
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ 㩔㩢㩙㨺㩂
+0/#4
㩂㩥ޓ// 41*5
+057.#6+105.''8' .#$'.
+0/#4
%1&'01 %1&'
01
㩃㨺㩖㩨㩣⼔᧚ 㩔㩢㩙㨺㩂 %1/2#555#('
&+56#0%'
41*5 41*5
%#$.'2416'%6+10 56+%-'4
/#6'4+#. %1&'01 %1&'
01
㩄㩧㩗㩨㨹㩂㩇 㩃㨺㩖㩨㩣⚵ຠ
%8$ 5
%#$.'6+' 219'4%#$.'#55;
%1&'01 %1&'
01
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 㩃㨺㩖㩨㩣⚵ຠ 㩊㨺㩚㩏㩣㩟㩐㨹㩎↪(ޓ14
6'4/+0#.70+6
01 (','$%2.
5'.($10&+0)6#2' %#$.'#55'/$.;
%1&'01 %1&'
01
㩄㩒㩂㩊
0
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷
02&($%( :575
%100'%614 5'.(6#22+0)5%4'9
%1&'01 %1&'
01
㩃㨺㩖㩨㩣⚵ຠ 49 㩖㩩㩢㩧㩊ขઃ᧼
⚵ຠ
49 %2
%#$.'#55; 24+06'4(+:674'
%1&'01 %1&'
01
㩃㩚㩆㨺㩣 㩖㩩㩢㩧㩊ขઃ᧼
⚵ຠ
59㨻㩣㩚㩋㨷㨺㩖㩨) %2
5+.+%1047$$'4 24+06'4(+:674'
%1&'01 %1&'
01
㩄㩒㩂㩊
60%0
60%20,
%1#:+#.%100'%614
#ਸ਼ %1&'01
㩃㨺㩖㩨㩣⚵ຠ
62#($10,($#&($
%#$.'#55'/$.;
%1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎ
ޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
37#.+6;+56*'5#/' 241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
%/$ %/)
##:
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
A-10 A-11
24%'/5#
%1&'01 #-:
6;2'
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
%2
࡙࠾࠶࠻ 70+6
Ꮏ᧚ᢱ #%&%㔚Ḯ
24
+056#..#6+10/#6'4+#.5 219'45722.;70+6
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
176.+0' 3 6; Ꮏ᧚ᢱ +056#..#6+10/#6'4+#.5
01 0#/' &'5%4+26+105 4'/#4-5
41*5 Ꮏ᧚ᢱ
㩃㨺㩖㩨㩣߃
%2
%#$.'%.#/2 +056#..#6+10/#6'4+#.5
%1&'
01
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
:575
5'.(6#22+0)5%4'9
%1&'
01
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ䍘䍎䍢䍼䉕䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎޕ
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/' 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%/& %<,
A-12 A-13
ᡷㅧ㩁㨹㩎 Ꮏ᧚ᢱ
/1&+(+%#6+10-+6 +%
+056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
ਛ࿖41*5㩙㨺㩂 㩕㨷㨺㩇㩨㩔㩢㩙㨺㩂
41*5
%*+0#41*55'#. (75'.#$'.
%1&'01 %1&'
01
㩔㩢㩙㨺㩂
#.% ޓ41*5 㨻㨺㩇᧼ 41*5
.#$'. %122'4564#2
%1&'01 %1&'
01
ဳᑼ㌏᧼
#.%
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷
:575
0#/'2.#6'
#.% 5'.(6#22+0)5%4'9
%1&'01 %1&'
01
(&41/ 㩕㨷㨺㩇㩨
()$18#2$(
(.122;&+5-41/ (75').#5567$'6;2'
%1&'01 %1&'
01
㩃㨺㩖㩨㩣⚵ຠ/,
/,#52(<%
%#$.'#55;
%1&'
01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 241&7%637#.+6;+56*'5#/'
37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
%/& %/'
A-14 A-15
%1&'01 #-:
%1&'01 #-:
6;2' 52 $1:012
6;2' %2
5'652'4
5*+201 52#4'2#465.+56(14 75' 8'55'.
Ꮏ᧚ᢱ
+056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 &9)01 37#06+6; 4'/#4-5%1&'01
㩖㨱㩇㩏㨺
+6'/ 0#/'1( 14 914-+0)
01 2#46 176.+0'
41*5 6;2'01 2'4 2'4 52#4'
*11-.112(#56'0'4 5'6 8'5
%1&'01
㩕㨷㨺㩇㩨
㩖㨱㩇㩏㨺
(75'
41*5 ()$18
*11-.112(#56'0'4 #2$(
%1&'01
㩕㨷㨺㩇㩨
㩔㩢㩙㨺㩂 (75'
()$18#
2$(
.#$'.
%1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
/(4 50#/' (74701'.'%64+%%1.6& &9)01 %2%
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(ޓ144'('4'0%'10.;㧕
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ
⾰ߪᄌࠊࠅ߹ߖࠎޕ
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(
%/( 6*'722'4241&7%637#.+6;+56*'5#/'
18/Jun/09 R.Esumi
18/Jun/09 R.Esumi
8/Jul/09 R.Esumi
D-4
26/Oct/09 R.Esumi
Oct.15'07 R.Esumi
13/Jan/2012 Y.NISHIYAMA
西 山義浩
1 2 3 4 5 6
アンテナユニット
ANTENNA UNIT
IC-115
アラームユニットIC-306
ケーブル/コネクタは選択 ALARM UNIT
RW-4747 SELECT CABLE & CONNECTOR 16P0213B
TNCP-NJ
0.3m
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA ターミナルユニット 1 VCC
FBA-5DFB,0.4m 8D-FB-CV,50m,φ14.3: N-P-8DFB TERMINAL UNIT P
2 GND
5D-FB-CV,30m,φ10.7: N-P-5DFB IC-215 3 TD/RD-A
A P
4 TD/RD-B
*7 ANT DGPS *1 5 FG
TP5FBAW-5DFBB,30m,φ7.7 BNC PLUG COAX. CABLE(50Ω) DGPSデコーダー
DGPS DECODER
遭難警報器 IC-305 IC-350を接続するとき(IC-305との共用不可)
2B02 16P0208A DISTRESS ALERT/
*3 接続箱 RECEIVED CALL UNIT CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
Dsub15P JUNCTION BOX
KEYBOARD JUNCTION IC-315 *1 16P0213A
キーボード 1.6m 2m TTYCS-4 IC-315 *1
1 KDAT Vcc(ALM) 1 1 1 VCC 選択 INMARSAT No.1/2
KEYBOARD P
SELECT TTYCS-1
2 NC GND 2 2 2 GND 3 1 TR-A
2 TR-B アラームユニット
P
3 GND TD/RD-A 3 3 3 TD/RD-A 4
4 +5V TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
5 KCLK NC 5 5 5 FG IC-350 *2
6 NC TD-A 6 6
TD-B 7 7 TTYCS-1(*1) OR
CO-0.2x2P(*2) 航法装置 保安警報発呼器 保安警報発呼器 保安警報発呼器
船内LAN (HUB) RJ-45 LAN RD-A 8 8 NAV EQUIPMENT
STP CABLE(CAT5) *1 1 9 9 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
パソコンなど PC: CROSS CABLE P
E_TD_P RD-B
IC-307 (No.1) *2 *6 IC-307 (No.2) IC-307 (No.3)
2 10 10 TTYCS-4(*1) OR
LAN(HUB) OR PC, ETC. HUB: STRAIGHT CABLE E_TD-N GND
CO-0.2x5P(*2) *2 *6 *2 *6
3 E_RD_P DMC_OUT-H 11 11 1 SSAS_OUT-H 1 1
4 12 12 2 2 2
B P
5
NC
NC
DMC_OUT-C
DMC_CHECK 13 13
P
3
NC
SSAS_CHECK
P
3
P
3
P P P
6 E_RD_N DMC_IN-C 14 14 4 SSAS_IN-C 4 4
7 NC DMC_CTRL 15 15 5 SSAS_CTRL 5 5
8 NC 6 GND 6 6