Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Messrs.: Specification For Approval

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

MESSRS.

SPECIFICATION FOR APPROVAL


承 認 書
Product ELECTRO MAGNETIC BUZZER

Part No. AC-1205G-P1-LF

Customer
Approval

Customer
Part No.

Approved By Checked By Made By

工程部 工程部 工程部


JASON CHEN ZACK GUO JERRY CHEN
JAN-29-2013 JAN-29-2013 JAN-29-2013

Advanced Acoustic Technology Corporation


昊宬股份有限公司//常州笠翔电子有限公司
Head Company / 2F, No.207, Sec. 6, Chung Shan N. Rd., Taipei, Taiwan
Tel: +886-2-8866-5255 Fax: +886-2-8866-5250
大陸總公司 / 中國江蘇省常州市新北區龍虎塘工業園新苑四路 89 號
Tel: +86-519-8511-2382 Fax: +86-519-8510-0908
ISO 14001 Certified
http://www.aatc.tw EDITION:1.1
QS9000 Certified

RoHS
AATC-FORM-S001
ADVANCED ACOUSTIC TECHNOLOGY CORP.
昊 宬 股 份
TECHNOLOGY 有 限 公 司
CORP.
REVISIONS

PRODUCT ELECTRO MAGNETIC BUZZER

PART NO. AC-1205G-P1-LF

REV. REVISER DATE DESCRIPTION

1 JERRY 2013-01-29 Creating new drawing SPEC.

RoHS
1. SPECIFICATION AC-1205G-P1-LF

ITEM UNITS SPECIFICATIONS CONDITIONS

01 Rated Voltage V 5.0 Vp-p


0V
02 Operating Voltage V 3.0 ~ 7.0
Applying rated voltage, rated frequency
mA Mean: 50
03 Consumption Current Square wave, 1/2 duty subject to standard
(Max)
Peak: 150 state.

04 Direct Current Resistance Ω 40± 6


Applying rated voltage, rated frequency
Sound pressure level dBA
05 85 Square wave, 1/2 duty subject to standard
(Distance at 10cm ) (Min)
state.

06 Rated Frequency Hz 2400

07 Operating Temp. ℃ -30 ~ +70

08 Storage Temp. ℃ -40 ~ +85

09 Weight g 2.0

2. MEASURING METHOD

2-1. Test Condition 2-2. Standard drive circuit


STANDARD
Temperature : 15 ~ 35℃
Relative humidity : 45% ~ 85%, VCC
Atmospheric pressure: 860mbar to 1060mbar.

JUDGEMENT
+
Temperature : 20±3℃
Vo-p Sample
Relative humidity : 60% ~ 70%,
Atmospheric pressure : 860mbar to 1060mbar 1/2 duty
-
Square wave

Tr:2SC1741AS or Equivalent
Vin HE8050
180  Vce< 0.15V

RoHS
2-3. Standard Test Fixture

Drive Circuit
Power Amplifier
DC Power

Buzzer Microphone
B&K Type 4191 & 2669
Audio Analyzer B&K Type 2012

SPL meter
B&K Type 2240
2-4. Frequency Response Curve
ELECTRO MAGNETIC BUZZER Jerry

ADVANCED ACOUSTIC TECHNOLOGY CORPORATION


4. RELIABLITY TESTS

Item Test conditions Evaluation standard


The part shall be capable of withstanding a storage
01 High temp. Storage life
Temperature of +85℃ for 96 hours.
The part shall be capable of withstanding a storage
02 Low temp. Storage life
Temperature of -40℃ for 96 hours.
The part shall be subjected 10 cycles.
One cycle shall of ;

85°C
03 Temp. cycle
-40°C
30 min 30 min
60 min

The part shall be subjected 10 cycles. One cycle


shall be 12 hours and consist of;

04 Temp./Humidity cycle 1. After the test the part shall meet


specifications without
Any degradation in appearance
and performance except S.P.L
Rated Voltage, Frequency applied. 2. S.P.L shall be ±7 dB.
1. Ordinary temperature
The part shall be subjected to 1000 hours at
room temperature (25 ±10℃)
1. High temperature
05 Operating life
The part shall be subjected to 500 hours at
70℃
2. Low temperature
The part shall be subjected to 500 hours at
-30℃

Amplitude:1.5mm
9.3g
0.3g Time :1min/axis

06 Vibration 10 55 Hz

Make this test for the directions of X, Y, Z for 2


hours each (total 6 hours).
Item Test conditions Evaluation standard
The part only shall be dropped from a height of
75cm onto a 40mm thick wooden board 1 times
Free drop
in 3 Direction each (X.Y.Z).
(a total of 3 times).
07
The part only shall be dropped from a height of
100cm onto a 10mm thick wooden board 1 times
Free drop (Packing)
in 3 axes (X.Y.Z).
(a total of 3 times).
Hand Soldering : 360±5℃ / ≦ 2 Sec.
08 Solder ability
Recommend using constant searing-iron
1. After the test the part shall meet
specifications without
Any degradation in appearance
and performance except S.P.L
2. S.P.L shall be ±7 dB.
09 Soldering profile

Soldering into solder bath: 260±5℃.


Pull lead with a force of 5N,on the direction
10 Lead strength
of the lead axis for 10 :10±1 sec
Solvent : deionizer water
11 Wash ability Solvent temp. : 55±5℃
Soaking time : 5±0.5 min.

Note:
1. After solder bath, the cooling time must be longer than 2 hours before function test.
2. If you need more information, please contact our technology department, thank you.