Digital Power Meter

DM38
Features
LCD display with back lighting
Modbus-RTU communication
DIN rail type

MEASUREMENT PARAMETERS:
• Phase Voltage ( L-N )
• Line Voltage ( L-L )
• Phase Current
• Bidirectional kW (per phase & total)
• Bidirectional kVAR (per phase & total)
• Bidirectional kVA (per phase & total)
• Frequency
• Power Factor (per phase & total)
• Energy (+ and - ) for kWh, kVARh and kVAh
• THD Phase Voltage ( L-N )
• THD Phase Current

Technical Data
DISPLAY TYPE POWER MEASUREMENT POWER SUPPLY
LCD display Real power, apparent power, reactive power Self supplied : 100 ~ 240 V AC
measurement Frequency : 50 / 60 Hz
Measuring updating period :1s Power consumption : <3 VA
MEASUREMENTS Accuracy : 1.0%
3-phase 4-wire system
COMMUNICATION
POWER FACTOR MEASUREMENT Hardware interface : Isolated RS485
CURRENT MEASUREMENT (TRMS) Total and displacement power factor Protocol : Modbus-RTU
CT primary : 5 ~ 8000 A Accuracy : 1.0% Baud rate : 2400, 4800, 9600,
CT secondary :5A 19200, 38400
Minimum measurement : 10 mA
Accuracy : 0.5% from 1A to FREQUENCY MEASUREMENT
6 A (secondary) Measurement range : 45 ~ 65 Hz ENVIRONMENTAL CONDITIONS
Burden : < 0.03 VA at 5 A Measurement updating period : 1s Operating temperature : -10˚C ~ +55˚C
Sustained overload :6A Accuracy : 0.5% Storage temperature : -20˚C ~ +70˚C
Humidity : 0 – 95%,
non condensing
VOLTAGE MEASUREMENT (TRMS) ENERGY ACCURACY
Nominal phase voltage : 70 ~ 300 V AC Active (according to IEC 62053-21) : class 1 MECHANICAL
Minimum measurement : 10 V Reactive (according to IEC 62053-23) : class 2 Mounting : DIN rail
DM 38

Accuracy : 0.5% at full scale Dimension (mm) : 65(w) x 85(h) x 50(d)


Approximate weight : 0.3 kg
Digital Power Meter

Typical Application Diagram

DM 38 CONNECTION DIAGRAM

RS 485 120 Ohm


S1 S2 S1 S2 S1 S2 Modbus-RTU

1 2 3 4 5 6 7 8 9 10 11
I1 I2 I3

+
GND P1
S1
DM38
L1 ! S2

X
LOAD
L2 P2
L3
Ln
NOTE: Current transformer secondary
12 13 14 15 16 17 18 19 20 21 22
terminal MUST NOT be earthed.
L1 L2 L3 Ln

Electromagnetic Compatibility (EMC) Case Dimensions

Part 6-2: Generic Standards IEC61000-6-2


Immunity for industrial environments. Front
65 mm
Part 6-4: Generic Standards IEC61000-6-4
Emission standard for industrial environments.

45.5 mm
85 mm

Ordering Information
71 mm

MODEL DESCRIPTION
DM 38-240A Self Powered 100~240 V AC
Side
50 mm
DM 38

15.5 mm