Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

GGW40 50Hz

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

GGW040 | 4.

5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

Image used for illustration purposes only

Power Ratings
Standby 40 kVA/32 kW
GGW040
Prime 36 kVA/29 kW

Codes and Standards ENERGY GENERATION


Not all codes and standards apply to all configurations. Contact
PRAMAC ensures superior quality and performance by managing all
factory for details.
aspects of production: from design to manufacturing.
PRAMAC can trace its roots back to 1966; from then onwards it has
BS5514 and DIN 6271
TM

been expanding its activity in the energy and material-handling sector,


continuously growing globally with a wide and flexible product range.
SAE J1349 In the field of power generation, PRAMAC offers solutions for every
®

kind of power supply demand: portable and industrial generators for


stand by and prime power applications, and mobile and towable
ISO 3046, 7637, 8528, 9001
lighting for outdoor needs.

NEMA ICS10, MG1, 250, ICS6, AB1 PRAMAC operates through a wide distribution network and provides
global coverage even in the most demanding markets.
ANSI C62.41
50 Hz SPEC SHEET

1 of 6
GGW040 | 4.5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

STANDARD FEATURES

ENGINE SYSTEM ELECTRICAL SYSTEM GENERATOR SET


• Oil Drain Extension • Battery Charging Alternator • Internal Genset Vibration Isolation
• Heavy Duty Air Cleaner • Battery Cables • Separation of Circuits - High/Low Voltage
• Level 1 Fan and Belt Guarding (Open Set Only) • Battery Tray • Separation of Circuits - Multiple Breakers
• Stainless Steel Flexible Exhaust Connection • Rubber-Booted Engine Electrical Connections • Wrapped Exhaust Piping
• Factory Filled Oil and Coolant • Solenoid Activated Starter Motor • Standard Factory Testing
• Critical Silencer • 1 Year Limited Warranty (or 1,000 Hours)
• Oil Temperature Sender with Alarm ALTERNATOR SYSTEM
• Air Filter Restriction Indicator
• Class H Insulation Material
ENCLOSURE (If Selected)
• 2/3 Pitch • Rust-Proof Fasteners with Nylon Washers to
FUEL SYSTEM • Skewed Stator Protect Finish
• NPT Fuel Connection on Frame • Brushless Excitation • High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Primary and Secondary Fuel Shutoff • Sealed Bearing
• Gasketed Doors
• Full Load Capacity Alternator
• Upward Facing Discharge Hoods (Radiator
COOLING SYSTEM and Exhaust)
• Closed Coolant Recovery System • Stainless Steel Lift Off Door Hinges
• UV/Ozone Resistant Hoses • Stainless Steel Lockable Handles
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension

CONTROL SYSTEM • Expandable Analog and Digital Inputs and Outputs 4.3 Inch Color Touch Screen Display
• Remote Wireless Software Update Capable • Resistive Color Touch Screen
• Wi-Fi®, Bluetooth®, BMS, and Remote Telemetry • Easily Identifiable Icons
• Built-In Programmable Logic Eliminates the Need for • Multi-Lingual
POWERZONE® External Controllers Under Most Conditions
• On Screen Editable Parameters
PRO • Programmable I/O Channel Properties
• Key Function Monitoring
• Built-In Diagnostics
• Three Phase Voltage, Amperage, kW, kVA, and kVAr

Alarms and Warnings


• Selectable Line to Line or Line to
Neutral Measurements
• High/Low Oil Pressure • Frequency
• High/Low Coolant Level • Engine Speed
• High/Low Coolant Temperature • Engine Coolant Temperature
• Sender/Sensor Failure • Engine Oil Pressure
• High/Low Oil Temperature • Engine Oil Temperature
• Over Total kW • Battery Voltage
• Over/Under Speed • Hourmeter
Power Zone® Pro Controller • Over/Under Voltage • Warning and Alarm Indication
• NFPA 110 Level 1 Compliant • Over/Under Frequency • Diagnostics
• Engine Protective Functions • Over Current • Maintenance Events/Information
50 Hz SPEC SHEET

• Alternator Protective Functions • High/Low Battery Voltage


• Digital Engine Governor Control • Battery Charger Current
• Digital Voltage Regulator • Phase to Phase and Phase to Neutral Short Circuits
• Multiple Programmable Inputs and Outputs (I2T Algorithm)
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time Stamping
2 of 6
GGW040 | 4.5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

CONFIGURABLE OPTIONS

ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM


○ Heater with Shutoff Valves ○ Extended Factory Testing (3-Phase Only) ○ 21-Light Remote Annunciator
○ Fluid Containment Pan ○ 8 Position Load Center ○ Remote Relay Assembly (8 or 16)
○ Engine Coolant Heater ○ Spring Vibration Isolators ○ Remote E-Stop (Break Glass-Type, Surface Mount)
○ Oil Heater ○ Pad Vibration Isolators ○ Remote E-Stop (Red Mushroom-Type,
○ Level 1 Fan and Belt Guards (Enclosed Units Only) Surface Mount)
○ Radiator Duct Adapter (Open Set Only) ENCLOSURE ○ Remote E-Stop (Red Mushroom-Type, Flush Mount)
○ Two-Stage Heavy Duty Air Cleaner ○ 10A Engine Run Relay
○ Weather Protected Enclosure ○ Ground Fault Annunciator
○ Level 1 Sound Attenuated ○ 120V GFCI and 240V Outlets
FUEL SYSTEM ○ Level 2 Sound Attenuated ○ 100 dB Alarm Horn
○ NPT Flexible Fuel Line ○ Level 2 Sound Attenuated with Motorized Dampers ○ Damper Alarm Contacts (with Motorized
○ Steel Enclosure Dampers Only)
ELECTRICAL SYSTEM ○ Aluminum Enclosure ○ Wi-Fi Extension Kit

○ 10A Battery Charger


○ Up to 321 KPH Wind Load Rating (Contact Factory
for Availability)
○ Battery Warmer ○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters (with Motorized Dampers Only)
ALTERNATOR SYSTEM ○ Door Open Alarm Horn
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating

CIRCUIT BREAKER OPTIONS


○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ 3rd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers

ENGINEERED OPTIONS

CONTROL SYSTEM GENERATOR SET


○ Spare Inputs (x4) / Outputs (x4) ○ Special Testing
○ Battery Disconnect Switch ○ Battery Box

50 Hz SPEC SHEET

3 of 6
GGW040 | 4.5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

APPLICATION AND ENGINEERING DATA

ENGINE SPECIFICATIONS
General Lubrication System

Cylinder # 4 Oil Pump Type Gear Driven


Type In-Line Oil Filter Type Full-Flow Spin-On Cartridge
Displacement - L (in3) 4.5 (275.0) Crankcase Capacity - L (qt) 20 (21)
Bore - mm (in) 114.3 (4.5)
Stroke - mm (in) 107.95 (4.25) Cooling System
Compression Ratio 9.94:1
Intake Air Method Naturally Aspirated Cooling System Type Pressurized Closed
Number of Main Bearings 5 Fan Type Pusher
Connecting Rods Forged Steel, Fractured Split, Bushingless Fan Speed - RPM 2,100
Cylinder Head Cast Iron Fan Diameter - mm (in) 508 (20)
Cylinder Liners Cast Iron
Ignition Coil Near Plug Solid State Inductive Fuel System
Piston Type Cast Aluminum Flat Top
Crankshaft Type Forged Steel Fuel Type Natural Gas, Propane
Lifter Type Hydraulic Fuel Injection Electronic
Intake Valve Material Stainless Steel Fuel Shut Off Dual
Exhaust Valve Material Stainless Steel NG Operating Fuel Pressure - kPa (in H2O) 1.2 - 3.5 (5 - 14)
Hardened Valve Seats High Steel Iron Alloy Propane Operating Fuel Pressure
- kPa (in H2O) 1.7 - 3.5 (7 - 14)
Engine Governing
Engine Electrical System
Governor Electronic
Frequency Regulation (Steady State) ±0.25% System Voltage 12 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index 10000016949
Battery Voltage 12 VDC
Ground Polarity Negative

ALTERNATOR SPECIFICATIONS
Standard Model R0040124Y21 Standard Excitation Synchronous Brushless
Poles 4 Bearings Sealed Ball
Field Type Revolving Coupling Direct via Flexible Disc
Insulation Class - Rotor H Prototype Short Circuit Test Yes
Insulation Class - Stator H Voltage Regulator Type Full Digital
Total Harmonic Distortion <5% (3-Phase Only) Number of Sensed Phases All
Telephone Interference Factor (TIF) <50 Regulation Accuracy (Steady State) ±0.25%
50 Hz SPEC SHEET

4 of 6
GGW040 | 4.5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

OPERATING DATA

POWER RATINGS

Standby Prime
Single-Phase 110/220 VAC @1.0pf 32 kVA/32 kW Amps: 145 29 kVA/29 kW Amps: 131
Three-Phase 231/400 VAC @0.8pf 40 kVA/32 kW Amps: 58 36 kVA/29 kW Amps: 52

MOTOR STARTING CAPABILITIES (skVA)

skVA vs. Voltage Dip


231/400 VAC 30%
R0040124Y21 82
R0048124Y21 104

FUEL CONSUMPTION RATES*


Natural Gas – m3/hr (scfh) Propane – m3/hr (scfh)
Percent Load Standby Prime Percent Load Standby Prime
25% 5.3 (187) 5.1 (180) 25% 2.7 (95) 2.6 (92)
50% 7.5 (264) 7.1 (250) 50% 3.5 (125) 3.4 (119)
75% 9.6 (338) 9.0 (317) 75% 4.4 (155) 4.2 (150)
100% 11.8 (415) 10.9 (386) 100% 5.2 (184) 4.9 (173)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.

COOLING
Standby Prime
Air Flow (Fan Air Flow Across Radiator) - Open Set m3/min (cfm) 82.5 (2,914)
Coolant Flow Lpm (gpm) 116 (30.7) 118 (31.3)
Coolant System Capacity L (gal) 11.4 (3.0)
Maximum Operating Ambient Temperature °C (°F) 50 (122)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 10000011319
Maximum Additional Radiator Backpressure kPa (in H2O) 0.12 (0.5)

COMBUSTION AIR REQUIREMENTS


Standby Prime
Flow at Rated Power - m3/min (cfm) 2.1 (75.2) 1.7 (61.5)

ENGINE EXHAUST
Standby Prime Standby Prime
Rated Engine Speed RPM 1,500 1,500 Exhaust Flow (Rated Output) m3/min (cfm) 6.2 (221) 5.1 (180)
Maximum Allowable Backpressure
Horsepower at Rated kW hp 49 44 kPa (inHg) 2.54 (0.75) 2.54 (0.75)
(Post Silencer)
Piston Speed m/min (ft/min) 324 (1,063) 324 (1,063) Exhaust Temperature (Rated Output) °C (°F) 607 (1,124) 602 (1,116)
BMEP kPa (psi) 554 (80) 498 (72)

Deration - Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
50 Hz SPEC SHEET

Please contact a Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards.
Standby - See Bulletin 0187500SSB
Prime - See Bulletin 0187510SSB

5 of 6
GGW040 | 4.5L | 40 kVA
INDUSTRIAL SPARK-IGNITED GENERATOR SET
PRAMAC | Power Engineering Division

DIMENSIONS AND WEIGHTS*

OPEN SET
L x W x H - mm (in) 1,984 (78.1) x 947 (37.3) x 1,128 (44.4)
H Weight - kg (lbs) 760 - 793 (1,675 - 1,748)

L W

WEATHER PROTECTED ENCLOSURE


L x W x H - mm (in) 2,408 (94.8) x 965 (38.0) x 1,461 (57.5)
Steel: 980 - 1,013 (2,160 - 2,233)
H Weight - kg (lbs)
Aluminum: 859 - 891 (1,894 - 1,965)

L W

LEVEL 1 SOUND ATTENUATED ENCLOSURE


L x W x H - mm (in) 2,408 (94.8) x 965 (38.0) x 1,461 (57.5)
Steel: 1,024 - 1,056 (2,258 - 2,329)
H Weight - kg (lbs)
Aluminum: 901 - 935 (1,987 - 2,061)

L W

LEVEL 2 SOUND ATTENUATED ENCLOSURE


L x W x H - mm (in) 2,408 (94.8) x 965 (38.0) x 1,461 (57.5)
Steel: 1,062 - 1,095 (2,341 - 2,414)
H Weight - kg (lbs)
Aluminum: 939 - 972 (2,071 - 2,144)

L W

* Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please contact a PRAMAC Industrial Dealer for detailed installation drawings.

50 Hz SPEC SHEET

6 of 6
PR Industrial s.r.l. | Località Il Piano snc | 53031 Casole d'Elsa, Siena - Italy Part No. A0000920820
©2021 PR INDUSTRIAL SRL. All rights reserved. All specifications are subject to change without notice. Rev. B 06/21/2021

You might also like