Mat Foundation Y Dir Rebar Design
Mat Foundation Y Dir Rebar Design
Mat Foundation Y Dir Rebar Design
51 Calshot Road
CKMbT Internationals pte Ltd
Calcs for Start page no./Revision
#01-20/21/22/23
229 Mountbatten Rd
Mat Foundation Y dir Rebar Design 1
Mountbatten Square, Singapore 398007 Calcs by Calcs date Checked by Checked date Approved by Approved date
RAM 28/6/2023
Design summary
Overall design utilisation; 0.983
Overall design status; PASS
Section 1 Strip Design 800x1000
Description Unit Provided Required Utilisation Result
Top reinforcement mm2 1206 1185 (crk) 0.983 PASS
Bottom reinforcement mm2 1206 1185 (crk) 0.983 PASS
Shear reinforcement mm2/m 2681 905 0.338 PASS
Concrete details - Table 3.1. Strength and deformation characteristics for concrete
Concrete strength class; C32/40
Aggregate type; Quartzite
Aggregate adjustment factor - cl.3.1.3(2); AAF = 1.0
Characteristic compressive cylinder strength; fck = 32 N/mm2
Mean value of compressive cylinder strength; fcm = fck + 8 N/mm2 = 40 N/mm2
Mean value of axial tensile strength; fctm = 0.3 N/mm2 (fck/ 1 N/mm2)2/3 = 3.0 N/mm2
Secant modulus of elasticity of concrete; Ecm = 22 kN/mm2(fcm / 10 N/mm2)0.3 AAF = 33346 N/mm2
Ultimate strain - Table 3.1; cu2 = 0.0035
Shortening strain - Table 3.1; cu3 = 0.0035
Effective compression zone height factor; = 0.80
Effective strength factor; = 1.00
Coefficient k1; k1 = 0.40
Coefficient k2; k2 = 1.0 (0.6 + 0.0014 / cu2) = 1.00
Coefficient k3; k3 = 0.40
Coefficient k4; k4 = 1.0 (0.6 + 0.0014 / cu2) = 1.00
Partial factor for concrete -Table 2.1N; C = 1.50
Compressive strength coefficient - cl.3.1.6(1); cc = 0.85
Design compressive concrete strength - exp.3.15; fcd = cc fck / C = 18.1 N/mm2
Compressive strength coefficient - cl.3.1.6(1); ccw = 1.00
Design compressive concrete strength - exp.3.15; fcwd = ccw fck / C = 21.3 N/mm2
Maximum aggregate size; hagg = 20 mm
Density of reinforced concrete; = 2500 kg/m3
Monolithic simple support moment factor; 1 = 0.25
Reinforcement details
Characteristic yield strength of reinforcement; fyk = 500 N/mm2
Partial factor for reinforcing steel - Table 2.1N; S = 1.15
Design yield strength of reinforcement; fyd = fyk / S = 435 N/mm2
6 × 16f
1000
Minimum area of reinforcement required - exp.7.1; Asc,min = kc k fct,eff Act / s = 1185 mm2
PASS - Area of tension reinforcement provided exceeds minimum required for crack control
Quasi-permanent moment; MQP = Mpos_QP_s1 = 0.0kNm
Permanent load ratio; RPL = MQP / M = 0.00
Service stress in reinforcement; sr = fyd As,req / As,prov RPL = 0 N/mm2
Maximum bar spacing - Tables 7.3N; sbar,max = 300 mm
PASS - Maximum bar spacing exceeds actual bar spacing for crack control