8/15 8/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
—
Energy efficiency
Energy meters ABB EQmatic and Energy meters G series
The details make the difference
Energy meters G series
G13 is the Ethernet gateway that will make data collection from a meter network very conve-
nient. communication is performed using JSON (JavaScript Object Notation) on the Ethernet
side. The gateway is also equipped with a webserver that provides a detailed overview of all
meters installed in a network as well as the possibility to perform advanced configurations
of the meters and read-out data. High data security is obtained by encryption using SSL (Se-
cure Sockets Layer).
G13
Seals for terminals The gateway communicates with Energy meters over EQ bus, a communication protocol
based on the IEC standards (DLMS/cosem), using RS-485, and can also work as an M-Bus
master for M-Bus enabled ABB meters.
8
8
Communication protocols on the meter side: EQ bus over RS-485, M-Bus and ABB IR port.
Communication protocols on the system side: Ethernet with JSON. built-in webserver
for meter reading and meter management.
—
Energy efficiency
Energy meters. The details make the difference.
—
Energy efficiency
Selection guide Energy meters.
8
mum demand and reduce them to avoid charges. Energy meters can tell you the value of the maximum/minimum demand and
also when it occurred. Harmonics is the source of many problems for all sorts of equipment connected to the low
voltage network. Use an Energy meter (Platinum level) to measure the THD and isolate the source before you have to take
the cost and consequences of poor power quality.
Transformer connected 1 3 5 1 2 3 1 2 3 4 5
2 element metering 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
3 element metering 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Active energy 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Reactive energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Apparent energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Import/Export energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Instrument values 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Alarm function 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Harmonics, 2th-16th and THD 5 5 5
Pulse output 1 1 1 1 1 1 2 1 2 1 2 1 2
IEC approved 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
1 = Steel
2 = Bronze
3 = Silver
4 = Gold
5 = Platinum
= Not available
Optional = Available on some order codes
8/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters selection table
Energy meters C11 Energy meters C13 Energy meters B21 Energy meters B23 Energy meters B24
Overall dimensions 1 DIN module 3 DIN modules 2 DIN modules 4 DIN modules
Frequency 50 / 60 Hz
Max current 40 A 65 A 6A
Reactive energy - -
Optional
Apparent energy - -
Up to 4 tariffs - - Optional
Max/min demand - - - - -
Previous values - - - - -
Load profiles - - - - -
Harmonic analysis - - - - -
Active power
Voltage
Instrumentation parameters (standard)
Current
Power factor
*) The pulse output can be assigned as an output if it is not used for pulses
**) For 16,7 Hz meters
8/19
Energy meters A41 Energy meters A42 Energy meters A43 Energy meters A44 Energy meters G13
8
50 / 60 Hz
50 / 60 Hz 50 / 60 Hz
(or 16,7 / 50 / 60 Hz)
80 A 6A 80 A 6A -
Standard feature -
-
optional
-
Cl. 1 (B) Cl. 1 (B), Cl. 0,5 S (C) Cl. 1 (B) Cl.1 (B), Cl. 0,5 S (C) -
Optional -
Optional -
Standard feature
Standard feature -
-
Instrumentation parameters (standard)
-
Standard feature -
—
Energy efficiency
Energy meters A series
Technical features
A41
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 57.7 - 288 V AC (-20% - +15%)
3x230/400 V AC
57.7 - 288 or 100 ... 288 V AC (-20% - +15%) 3x57.7/100 ... 288/500 V AC (-20% - +15%) 3x57.7/100 ... 288/500 or
3x100/173 ... 400/690 V AC (-20% - +15%)
1.8 VA (0.8 W) total at 230 V AC
0.001 VA (0.001 W) at Iref and In 0.006 VA (0.006 W) per phase at Iref 0.001 VA (0.001 W) at Iref and In*
- 5A -
1A - 1A
1A 5A 1A
0.05 A 0.5 A 0.05 A
8
6A 80 A 6A
0.02 A 0.25 A 0.01 A
< 1 mA < 20 mA < 1 mA
0.5 - 10 mm2 1 - 25 mm2 0.5 - 10 mm2
1.2 Nm 2 Nm 1.2 Nm
0.5 - 1 mm2
0.25 Nm
-40°C - +70°C
-40°C - +85°C
75% yearly average, 95% on 30 days/year
Terminal 960°C, cover 650°C (IEC 60695-2-1)
IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.
—
Energy efficiency
Energy meters A series
port a wide voltage range as well as a wide tem- A series meters with a functionality level of Gold
perature range. The display is pixel-oriented and or Platinum have an internal clock for
can display up to four quantities at the same advanced functionality:
time. Navigating the meter is easily done via the • Event log
push-buttons below the display. To configure the • Previous values
meter settings, the set button must be accessed • Load profile
and this • Maximum and minimum demand
button is protected against unauthorized use
when the “glass lid” on the front of the meter The tariffs are controlled via inputs, via
is closed and sealed. The exceptional low power communication or via an internal clock in Gold and
consumption of the meters makes them Platinum versions.
economical in the long run - an important feature
specially for large meter populations.
The A series support up to four I/O’s. It can be
two inputs and two outputs in a fixed configura-
Data from the A series meters can be collected via
tion or four I/O points that are freely configured
pulse output or serial communication. The pulse
to input or output. Inputs can be used for count-
output is a solid state relay that generates pulses
ing pulses from e.g. a water meter, or reading sta-
proportionally to the measured energy. The me-
tus from external devices. Outputs can be used as
ters can also be equipped with built-in serial com-
pulse outputs or controlling external apparatus
munication interfaces for M-Bus or Modbus RTU
like
(RS-485). Meters with RS-485 interface can also
a contactor or an alarm (connected via an external
be set to communicate over the new EQ bus with
relay). The I/O’s need an external voltage supply.
the gateway G13. All meters in the A series come
The A series meters are type approved according
with an infrared port for communication with an
to IEC and they are both type approved and veri-
external Serial Communication Adapter (SCA)
fied according to MID. MID is the Measuring In-
struments Directive 2014/32/EU from the Euro-
pean Commission. MID type approval and
verification is mandatory for meters in billing ap-
plications within EU and EEA. The type approval is
according to standards that covers all relevant
technical aspects of the meter. These include cli-
mate conditions, electromagnetic compatibility
(EMC), electrical requirements, mechanical re-
quirements and accuracy.
8/23
—
Energy efficiency
Energy meters A series
Technical features
A series
Outputs
Type Transistor or MOSFET
Current 2 - 100 mA
Voltage 5 - 240 V AC/DC. For meters with only 1 output, 5 -
40 V DC.
A series Pulse output frequency Programmable: 1 - 999999 imp/kWh
Pulse length Programmable: 10 - 990 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
Inputs
8
Voltage 0 - 240 V AC/DC
OFF 0 - 5 V AC/DC
ON 57 - 240 V AC/24 - 240 V DC
Min. pulse lenght 30 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
Immunity to conducted disturbance 150 kHz - 80 MHz, (IEC 61000-4-6)
Immunity to disturbance with harmonics 2kHz - 150kHz
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards EC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-
22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21,
GB/T 17215.211-2006, GBT 17215.321-2008 class 1
& 2, GB/T 17215.322-2008 class 0,5 S, GB
4208-2008, EN 50470-1, EN 50470-3 category A, B &
C Energy meters.
Mechanical
Material Polycarbonate in transparent front glass, bottom
case, upper case and terminal cover, Glass
reinforced polycarbonate in terminal block.
Dimensions A41 / A42 A43 / A44
Width 70 mm 123 mm
Height 97 mm 97 mm
Depth 65 mm 65 mm
DIN modules 4 7
8/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters A series
Direct connected energy meter up to 80 A. Verified and approved according to MID. IEC
approval.Instrument values. Alarm function. Communication - Infrared (M-Bus).
Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
57.7...288 V AC, Pulse output, RS-485 705004 A41 112 - 2CMA170500R1000 0.230 1
100
57.7...288 V AC, Pulse output, M-Bus 002400 A41 113 - 2CMA100240R1000 0.230 1
100
Class 1 (Reactive Class 2) with functionality level Silver. Active and
reactive energy, import/export, tariffs 1-4, tariff
controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
Energy meters A series
8
57.7...288 V AC, Pulse output, RS-485 705103 A42 112 - 2CMA170510R1000 0.200 1
100
57.7...288 V AC, Pulse output, M-Bus 002424 A42 113 - 2CMA100242R1000 0.200 1
100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
*) The meters are not tested and approved for placement on rolling stock.
8/26 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters A series
Direct connected energy meter up to 80 A. Verified and approved according to MID. IEC
approval. 2- and 3-element metering. Instrument values. Alarm function. Communication -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
Energy meters A series
Transformer CTVT connected energy meter up to 6 A. Verified and approved according to MID.
IEC approval. 2- and 3-element metering. Instrument values. Alarm function. Communica-tion -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
8
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze. Active and reactive energy, import/export.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 000130 A44 211 - 2CMA100013R1000 0.350 1
Pulse output 100
3 x 57.7/100...288/500 V AC, 705349 A44 212 - 2CMA170534R1000 0.350 1
Pulse output, RS-485 100
3 x 57.7/100...288/500 V AC, 705356 A44 213 - 2CMA170535R1000 0.350 1
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 2 output, 705363 A44 311 - 2CMA170536R1000 0.350 1
2 input 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Silver. Active and reactive
energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705370 A44 352 - 2CMA170537R1000 0.350 1
2 output, 2 input, RS-485 100
3 x 57.7/100...288/500 V AC, 705387 A44 353 - 2CMA170538R1000 0.350 1
2 output, 2 input, M-Bus 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Gold. Active and reactive energy, import/export,
tariffs 1-4, tariff controlled via inputs, communication or clock,previous values, max and min demand.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705400 A44 452 - 2CMA170540R1000 0.350 1
2 output, 2 input, RS-485 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Platinum. Active and reactive
energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock,
previous values, max and min demand, advanced load profiles, harmonics and THD.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705455 A44 552 - 2CMA170545R1000 0.350 1
Configurable 4 I/O channels, RS-485 100
3 x 57.7/100...288/500 V AC, 705462 A44 553 - 2CMA170546R1000 0.350 1
Configurable 4 I/O channels, M-Bus 100
3 x 57.7/100...400/690 V AC, 705493 A44 552 - 2CMA170549R1000 0.350 1
1 input + 1 output, RS-485 110
3 x 57.7/100...400/690 V AC, 705486 A44 553 - 2CMA170548R1000 0.350 1
1 input + 1 output, M-Bus 110
8/28 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters B series
Technical features
B21
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 220...240 VAC (-20% - +15%)
Power dissipation voltage circuits 1.1 VA (0.5 W) total at 230 V AC
Power dissipation current circuits 0.012 VA (0.012 W) at Iref and Ib
B series
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
Maximum current I max 65 A
8
B23 B24
3x230/400 V AC
3x220/380...240/415 VAC (-20% - +15%)
1.7 VA (0.8 W) total at 230 V AC
0.007 VA (0.007 W) per phase at Iref and Ib 0.0007 VA (0.0005 W) per phase at Iref and In
-
1A
-
0.05 A
6A
8
0.02 A
< 1 mA
0.5 - 10 mm2
1.2 Nm
1/9 - 9999/1
5000 imp/kWh
IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.
—
Energy efficiency
Energy meters B series
The Energy meters, B series is a range of meters for single phase and three phase metering.
The B series meters are mounted on a DIN rail and are suitable for installation in distribution
boards and small enclosures such as consumer units. The B series are suitable in applications
where there is a need for reliable energy measurements and where space
is limited.
The low rated or base currents of these products ensures high dynamic performance with
superior accuracy even at low currents. The B series meters are meters for many
applications and installations. Navigating the meter is easily done via the push-buttons be-
low the display. To configure the meter settings, the set button must be accessed and this
button is protected against unauthorized use when the “glass lid” on the front of the meter
is closed and sealed. The exceptional low power consumption of the meters, less than 0.9 VA
and 1.6 VA, makes them economical in the long run - an important feature specially for large
8
meter populations.
Data from the B series meters can be collected via pulse output or serial communication. The
pulse output is a solid state relay that generates pulses proportionally to the measured en-
ergy. The meters can also be equipped with built-in serial communication interfaces for M-
Bus or Modbus RTU (RS-485). Meters with RS-485 interface can also be set to
communicate over the new EQ bus with the new gateway G13. All meters in the B series come
with an infrared port for communication with an external Serial Communication
Adapter (SCA) such as the KNX adapter.
The B series meters support reading of instrument values. A large number of electrical
properties can be read. Depending on version of the meter the following data is available:
• Active power
• Apparent power
• Reactive power
• Current
• Voltage
• Frequency
• Power factor
The B series support two inputs and two outputs in a fixed configuration. Inputs can be used
for counting pulses from e.g. a water meter, or reading status from external devices. Out-
puts can be used as pulse outputs or controlling external apparatus like a contactor or an
alarm (connected via an external relay).
The B series meters are type approved according to IEC and they are both type approved and
verified according to MID. MID is the Measuring Instruments Directive 2014/32/EU from the
European Commission. MID type approval and verification is mandatory for meters in billing
applications within EU and EEA. The type approval is according to standards that covers all
relevant technical aspects of the meter. These include climate conditions, electromagnetic
compatibility (EMC), electrical requirements, mechanical requirements and accuracy.
8/31
—
Energy efficiency
Energy meters B series
Technical features
B series
Outputs
Current 2 - 100 mA
8
Inputs
OFF 0 - 5 V AC/DC
EMC compatibility
Impulse voltage test 6 kV 1.2/50μs (IEC 60060-1)
Standards IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class
0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-
2006, GB/T 17215.312-2008 class 1 & 2, GB/T 17215.322-
2008 class 0,5 S, GB 4208-2008, EN 50470-1, EN 50470-3
category A, B & C
Mechanical
Width 35 mm 70 mm
Height 97 mm 97 mm
Depth 65 mm 65 mm
DIN modules 2 4
8/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters B series
Direct connected energy meter up to 65 A. Verified and approved according to MID. IEC
approval. Instrument values. Alarm function. - Communication - Infrared (M-Bus).
Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
1 x 230 V AC, Pulse output, M-Bus 001519 B21 113 - 100 2CMA100151R1000 0.150 1
For direct connection up to 65 A. Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver.
Active and reactive energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
Energy meters B series
Direct connected energy meter up to 65 A. Verified and approved according to MID. IEC
approval. 2- and 3-element metering. Instrument values. Alarm function. Communication -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
8
100
3 x 230/400 V AC, Pulse output, 001649 B23 112 - 2CMA100164R1000 0.320 1
RS-485 100
3 x 230/400 V AC, Pulse output, 001656 B23 113 - 2CMA100165R1000 0.330 1
M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze.
Active and reactive energy, import/export.
—
Energy efficiency
Energy meters B series
—
Energy efficiency
Energy meters C series
The Energy meters, C series are truly compact meters for single phase and three phase
metering. The C series is mounted on a DIN rail and is suitable for installation in distribution
boards and small consumer units.
Only one or three module wide, the C series is a very compact meter for single phase
and three phase applications. The meters have an LCD with large digits showing energy
register and instrumentation values. The meters have a wide temperature range which
makes it possible to install the meters in many locations. Navigating the meters are easily
done via the push-button below the display. The exceptional low power consumption of the
meters, less than 0,3 W and 0,6 W at 230 V AC, makes them economical in the long run
- an important feature specially for large meter populations.
The C series meters support reading of instrument values. A number of electrical properties
8
can be read:
• Power factor
• Active power
• Current
• Voltage
The C series meters have an output that can be used as pulse output or alarm output.
The alarm quantity and levels is easily configured on the meter with the push button.
The output can be used for controlling external apparatus like a contactor or an alarm
indicator (connected via an external relay).
The C series meters are type approved according to IEC and MID. MID is the Measuring
Instruments Directive 2014/32/EU from the European Commission. The type
approval is according to standards that covers all relevant technical aspects of the meter.
These include climate conditions, electromagnetic compatibility (EMC), electrical
requirements, mechanical requirements and accuracy.
MID versions have initial verification according to annex F of the Measuring Instruments
Directive.
8/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters C series
Technical features
C11 C13
Voltage/current inputs
Nominal voltage 230 V AC 3x230/400 V AC
Voltage range 230 V AC (-20% - +15%) 3x230/400 V AC (-20% - +15%)
Power dissipation voltage circuits 7.4 VA (0.3 W) at 230 V 1.5 VA (0.6 W) total at 230 V
Power dissipation current circuits 0.04 VA (0.04 W) at Ib and Iref 0.04 VA (0.04 W) per phase at Ib
C series
and Iref
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
8
—
Energy efficiency
Energy meters C series
Technical features
C11 C13
Outputs
Type Transistor
Current 2 - 100 mA
Voltage 5 - 40 V DC
Pulse output frequency 100 or 1000 (imp/kWh)
Pulse length 100 ms
Terminal wire area 0.5 - 10 mm2 0.5 - 6 mm2
Recommended tightening torque 0.8 Nm 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)
8
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagneti 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
HF-fields
Immunity to conducted 150 kHz - 80 MHz, (IEC 61000-4-6)
disturbance
Immunity to disturbance with 2kHz - 150kHz
harmonics
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards IEC 62052-11, IEC 62053-21 class 1, GB/T 17215.211-2006, GBT
17215.321-2008 class 1, GB 4208-2008, EN 50470-1, EN 50470-3
category B
Mechanical
Material Glass reinforced polycarbonate
Dimensions
Width 17,5 mm 54 mm
Height 111 mm 122 mm
Depth 65 mm 65 mm
DIN modules 1 3
8/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201
—
Energy efficiency
Energy meters C series
For direct connection up to 40 A. Class B (Cl.1) with functionality level Steel. Active energy
C13
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
ABB EQmatic and Energy meters G series
QA/S 3.16.1
Description Order details Price Weight Pack
1 piece 1 piece unit
8
64 Devices 4016779997768 QA/S 3.64.1 2CDG110227R0011 0.15 1
16 Devices QA/S 3.16.1 2CDG110226R0011 0.15 1
QA/S 3.64.1
—
—
Energy efficiency
Energy meters ABB EQmatic and Energy meters G series
The details make the difference
Energy meters G series
G13 is the Ethernet gateway that will make data collection from a meter network very conve-
nient. communication is performed using JSON (JavaScript Object Notation) on the Ethernet
side. The gateway is also equipped with a webserver that provides a detailed overview of all
meters installed in a network as well as the possibility to perform advanced configurations
of the meters and read-out data. High data security is obtained by encryption using SSL (Se-
cure Sockets Layer).
G13
Seals for terminals The gateway communicates with Energy meters over EQ bus, a communication protocol
based on the IEC standards (DLMS/cosem), using RS-485, and can also work as an M-Bus
master for M-Bus enabled ABB meters.
8
8
Communication protocols on the meter side: EQ bus over RS-485, M-Bus and ABB IR port.
Communication protocols on the system side: Ethernet with JSON. built-in webserver
for meter reading and meter management.
—
new.abb.com/low-voltage/HU
abb.com/lowvoltage
Energy meters
A step toward environmental improvement
and fair cost allocation
9AKK107492A3149 - 05/2019
• MID Approved
• Reliable in harsh conditions
• Complete offer of functionalities
• Integrated in ABB Ability EDCS
© Copyright 2017 ABB. All rights reserved.
Specifications subject to change without notice.