Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Energy Meters

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

ABB Kft.

—Energetikai Termékek Üzletág


ABB
E-mail: kisfeszultseg@hu.abb.com
Electrification BusinessVáci út 99.
Cím: 1139 Budapest,
BL Smart Buildings


new.abb.com/low-voltage/HU

abb.com/lowvoltage

Energy meters
A step toward environmental improvement
and fair cost allocation
9AKK107492A3149 - 05/2019

• MID Approved
• Reliable in harsh conditions
• Complete offer of functionalities
• Integrated in ABB Ability EDCS
© Copyright 2017 ABB. All rights reserved.
Specifications subject to change without notice.
8/15 8/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201



Energy efficiency
Energy meters ABB EQmatic and Energy meters G series
The details make the difference
Energy meters G series
G13 is the Ethernet gateway that will make data collection from a meter network very conve-
nient. communication is performed using JSON (JavaScript Object Notation) on the Ethernet
side. The gateway is also equipped with a webserver that provides a detailed overview of all
meters installed in a network as well as the possibility to perform advanced configurations
of the meters and read-out data. High data security is obtained by encryption using SSL (Se-
cure Sockets Layer).
G13
Seals for terminals The gateway communicates with Energy meters over EQ bus, a communication protocol
based on the IEC standards (DLMS/cosem), using RS-485, and can also work as an M-Bus
master for M-Bus enabled ABB meters.

8
8
Communication protocols on the meter side: EQ bus over RS-485, M-Bus and ABB IR port.
Communication protocols on the system side: Ethernet with JSON. built-in webserver
for meter reading and meter management.

Description Order details Price Weight Pack


1 piece 1 piece unit

EAN Type code Order code kg pc.


100 - 240 V AC 7392696705523 G13 100-000 2CMA170552R1000 0.190 1

Infrared port for


DIN-Rail mounted
communication
and pro M design
between Meter Interface Module, KNX
communications It records consumption and measured values of the electrical energy consumption
MID approved
adapter and meter meters. Using an infra-red interface, the ABB energy meter types of the A- and B-series are
and verified
incorporated. The information and data which is read can be used, for example, for cost centre
accounting, energy optimisation, monitoring of installations and visualisation.

Description Order details Price Weight Pack


1 piece 1 piece unit

EAN Type code Order code kg pc.


KNX meter module 4016779662079 ZS/S 1.1 2CDG110083R0011 0.100 1
ZS/S 1.1

Pixel or Segment LCD


back-lit display

Configurable for both 3 Seals for access


and 4 wire networks to the SET button
8/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters. The details make the difference.

A series B series Instrumentation


Key applications Key applications The C series meters support reading
• Facility management installations • Cost transfer/billing of instrument values. A number of
• Critical power • Solar power electrical properties can be read:
• Production lines • EV chargers • Power factor
• System solutions • Elevators/escalators • Active power
• Power quality • Lighting • Current
• Etc. • Installation beside machines • Voltage
• Etc.
Key performance G13
Single phase or three phase Key performance Key applications
Direct connected up to 80 A or Single phase or three phase • Meter management and
transformer current- and/or voltage Direct connected up to 65 A or CT configuration
transformers (CTVT) connected (three phase types) • Remote reading of meter data
Active energy measurement Active energy measurement
8

• Integration of meters in system


• Class B (Cl. 1) or • Class B (Cl. 1) or
solutions
• Class C (Cl. 0,5 S) on CTVT • Class C (Cl. 0,5 S) on CT connected
• Etc.
connected meters meters
Wide voltage range Alarm functions
• 100 - 690 V phase to phase MID (Module B and D) Key performance
• 57,7 - 400 V phase to neutral Reactive energy measurement Connection to meters via
Alarm functions Import/export measurement of energy • RS-485 EQ bus or
MID (Module B and D) • Optional communication via via • M-Bus
Reactive energy measurement M-Bus or • IR (one port)
Import/export measurement of energy • RS-485 (For Modbus RTU or EQ Ethernet connection
Optional communication bus) • https, JSON
• via M-Bus or 4 tariffs controlled by Upgrade of firmware
• RS-485 (For Modbus RTU or EQ • input or • Gateway
bus) • communication • Meters (EQ bus)
4 tariffs controlled by inputs, Pulse outputs (S0 compatible) Time synchronization
• communication or Routing of data
• built-in clock Instrumentation
Previous values by The B series meters support reading of Built-in webserver
• day or instrument values. Meter readout via webserver
• week or A large number of electrical properties
• Individual meters
• month can be read. Depending on version of
Demand measurement (per period) • Cluster of meters
the meter the following data is
• 3 maximum • CSV export of meter data
available:
• 1 minimum • Active power • Read instrument values
Load profiles • Apparent power User authentication
• 8 channels independently • Reactive power • Administrator
configurable • Current • Restricted user
• 40 000 values total • Voltage Gateway settings
Harmonics measurement up to 16th • Frequency • IP address
harmonic • Power factor • Gateway name
• Current • Time and date
• Voltage Meter communication
• and evaluation of THD C series • Meter registration
Pulse outputs (S0 compatible) Key applications • Scan network
• HVAC applications • Register meter
Instrumentation • Stand-alone applications
• Add meter access rights
The A series meters support reading of • Domestic applications
• Read all data, all data found in the
instrument values. A large number of • Camping and Marinas
meters could be read in the
electrical properties can be read. • Etc.
Depending on version of the meter the webserver
following data is available: Key performance • Meter settings
• Active power Single phase or three phase Meter configuration via webserver
• Apparent power Very compact Basic meter settings
• Reactive power • 1 & 3 modules. • Ratio
• Current Direct connected up to 40 A • Time/date
• Voltage Active energy measurement • Pulse output/alarm
• Frequency Accuracy class 1 • Tariff settings
• Power factor Alarm functions • Inputs/outputs settings
• Harmonics (Current and Voltage) MID (Module B and F) as option Advanced function settings
• Total harmonic distortion Pulse output (S0 compatible) • Demand
• Previous values
• Load profile
8/17


Energy efficiency
Selection guide Energy meters.

How do I select the best meter for my application?


There are many versions of Energy meters in order to meet your requests. The EQ program comprises meters with different
func-tionalities such as tariffs, communication interfaces or advanced clock functions. Spend a little time to evaluate the func-
tions and imagine how they could add extra value to your metering. For example, the input counter (from Silver level)
on an Energy meter can be used to count products produced by a machine and be read out together with the energy
consumption of the same machine. In one easy go you can allocate energy to any produced product from one source. Another
useful function is previous values (from Gold level). If you charge users in intervals the meter can secure the data even in the
event of a broken communication link. You can collect the correct interval data later and also make it visible
for your counterpart immediately on the meters display in case of any discussions.

Make the meter to an asset.


Take the step from passive meter reading to an active user of the data you can retrieve. The meter can be an important asset
for you in order to avoid costs like penalties or extra charge for reactive energy (from Bronze level). Keep track of your maxi-

8
mum demand and reduce them to avoid charges. Energy meters can tell you the value of the maximum/minimum demand and
also when it occurred. Harmonics is the source of many problems for all sorts of equipment connected to the low
voltage network. Use an Energy meter (Platinum level) to measure the THD and isolate the source before you have to take
the cost and consequences of poor power quality.

Single phase Three phase


Function
C11 B21 A41 A42 C13 B23 B24 A43 A44
Direct connected 1 1 3 1 3 4 1 1 2 3 1 2 3 5

Transformer connected 1 3 5 1 2 3 1 2 3 4 5
2 element metering 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
3 element metering 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5

Accuracy 1 %, Class 1, Class B 1 1 3 1 3 4 1 3 1 1 2 3 1 2 1 2 3 5 1 2 3


Accuracy 0.5 %, Class 0,5 S, Class C 5 3 3 4 5

Active energy 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Reactive energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Apparent energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Import/Export energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5

Tariff registers, 1-4 3 3 4 3 5 3 3 3 5 3 4 5

Instrument values 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5

Alarm function 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Harmonics, 2th-16th and THD 5 5 5

Previous values - day, week, month 4 5 5 4 5

Max and min demand 4 5 5 4 5

Load profiles - 8 channels 5 5 5

Pulse output 1 1 1 1 1 1 2 1 2 1 2 1 2

I/O board - 2 in, 2 out 3 3 4 3 3 3 3 3 4

Configurable I/O - 4 I/O channels 5 5 5

Tariffs controlled by input 3 3 4 3 5 3 3 3 5 3 4 5

Tariffs controlled by communication 3 3 4 3 5 3 3 3 5 3 4 5

Tariffs controlled by clock 4 5 5 4 5

MID approved, verified optional 1 3 1 3 4 1 3 5 optional 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5

IEC approved 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5

Communication - Infrared (M-Bus) 1 3 1 3 4 1 3 5 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5


Communication - M-Bus optional optional optional optional optional optional optional
Communication - RS-485 Modbus optional optional optional optional optional optional optional
Communication - RS-485 EQ bus optional optional optional optional optional optional optional

1 = Steel
2 = Bronze
3 = Silver
4 = Gold
5 = Platinum
= Not available
Optional = Available on some order codes
8/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters selection table

Energy meters C11 Energy meters C13 Energy meters B21 Energy meters B23 Energy meters B24

Overall dimensions 1 DIN module 3 DIN modules 2 DIN modules 4 DIN modules

Display LCD Backlit LCD

Operating voltage 230 V AC 3x230/400 V AC 220...240 V AC 3x220/380...240/415 V AC


8

Frequency 50 / 60 Hz

Max current 40 A 65 A 6A

CTVT connection Direct Direct Direct Direct CT

Active energy Standard feature

Reactive energy - -
Optional
Apparent energy - -

Accuracy Cl. 1 (B) Cl. 1 (B), Cl. 0,5 S (C)

Up to 4 tariffs - - Optional

Max/min demand - - - - -

Previous values - - - - -

Load profiles - - - - -

Alarm function Standard feature

Harmonic analysis - - - - -

Event log - - Standard feature

Active power

Voltage
Instrumentation parameters (standard)
Current

Power factor

Frequency - - Instrumentation parameters

Pulse output Standard feature

I/O 1 Output* 1 Output* or 2 outputs/2 inputs (optional)

Built-in serial communication - - IR / M-Bus (optional) / RS-485 (optional)

Protocols - - M-Bus, Modbus RTU, EQ bus

*) The pulse output can be assigned as an output if it is not used for pulses
**) For 16,7 Hz meters
8/19

Energy meters A41 Energy meters A42 Energy meters A43 Energy meters A44 Energy meters G13

4 DIN modules 7 DIN modules 4 DIN modules

Backlit Pixel (LCD) No display

57.7...288 V AC or 3x57.7/100 ... 288/500 or


57.7...288 V AC 3x57.7/100 ... 288/500 100...240 V AC
100...288** V AC 3x57.7/100 ... 400/690

8
50 / 60 Hz
50 / 60 Hz 50 / 60 Hz
(or 16,7 / 50 / 60 Hz)

80 A 6A 80 A 6A -

Direct CTVT Direct CTVT -

Standard feature -

-
optional
-

Cl. 1 (B) Cl. 1 (B), Cl. 0,5 S (C) Cl. 1 (B) Cl.1 (B), Cl. 0,5 S (C) -

Optional -

Optional -

Standard feature

Power quality (optional) -

Standard feature -

-
Instrumentation parameters (standard)
-

Instrumentation parameters (optional) -

Standard feature -

1 output or 2 outputs/2 inputs (optional) or 4 configurable inputs and outputs (optional) -

IR / M-Bus (optional) / RS-485 (optional) IR, RS-485, M-Bus, Ethernet

M-Bus, Modbus, EQ bus HTTPS, EQ bus, M-Bus, JSON


8/20 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters A series

Technical features
A41
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 57.7 - 288 V AC (-20% - +15%)

Power dissipation voltage circuits 1.5 VA (0.6 W) total at 230 V AC


A-series Power dissipation current circuits 0.006 VA (0.006 W) at Iref and Ib
Base current Ib 5A
Rated current In -
Reference current Iref 5A
Transitional current Itr 0.5 A
8

Maximum current Imax 80 A


Minimum current Imin 0.25 A
Starting current Ist < 20 mA
Terminal wire area 1 - 25 mm2
Recommended tightening torque 2 Nm
Communication
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
Transformer ratios
Configurable current ratio (CT) -
Configurable voltage ratio (VT) -
Pulse indicator (LED)
Pulse frequency 1000 imp/kWh
Pulse length 40 ms
Frequency 50 or 60 Hz ± 5%
Accuracy Class B (Cl.1) and Reactive Cl. 2
Active energy 1%
Display of energy Pixel oriented display (LCD)
Environmental
Operating temperature -40°C - +70°C
Storage temperature -40°C - +85°C
Humidity 75% yearly average, 95% on 30 days/year
Resistance to fire and heat Terminal 960°C, cover 650°C (IEC 60695-2-1)
Resistance to water and dust IP20 on terminal block without protective
enclosure and IP51 in protective enclosure,
according to IEC 60529.
Mechanical environment Class M2 in accordance with the Measuring
Instrument Directive (MID). (2014/32/EU).
Electromagnetic environment Class E2 in accordance with the Measuring
Instrument Directive (MID), (2014/32/EU).

*) For 690 V AC meters:


Power dissipation voltage circuits 2.2 VA (1.0 W) total at 230 V AC
Power dissipation current circuits 0.001 VA (0.001 W) per phase at Iref and In
8/21

A42 A43 A44

3x230/400 V AC
57.7 - 288 or 100 ... 288 V AC (-20% - +15%) 3x57.7/100 ... 288/500 V AC (-20% - +15%) 3x57.7/100 ... 288/500 or
3x100/173 ... 400/690 V AC (-20% - +15%)
1.8 VA (0.8 W) total at 230 V AC
0.001 VA (0.001 W) at Iref and In 0.006 VA (0.006 W) per phase at Iref 0.001 VA (0.001 W) at Iref and In*
- 5A -
1A - 1A
1A 5A 1A
0.05 A 0.5 A 0.05 A

8
6A 80 A 6A
0.02 A 0.25 A 0.01 A
< 1 mA < 20 mA < 1 mA
0.5 - 10 mm2 1 - 25 mm2 0.5 - 10 mm2
1.2 Nm 2 Nm 1.2 Nm

0.5 - 1 mm2
0.25 Nm

1/9 - 9999/1 - 1/9 - 9999/1


1/999 - 999999/1 - 1/999 - 999999/1

5000 imp/kWh 1000 imp/kWh 5000 imp/kWh


40 ms
50 or 60 Hz ± 5 % (or 16.7 Hz optional) 50 or 60 Hz ± 5 %
B (Cl.1), C (Cl. 0,5 S) and Reactive Cl. 2 A (Cl.2), B (Cl.1) and Reactive Cl. 2 B (Cl.1), C (Cl. 0,5 S) and Reactive Cl. 2
0.5%, 1% 1% 0.5%, 1%

-40°C - +70°C
-40°C - +85°C
75% yearly average, 95% on 30 days/year
Terminal 960°C, cover 650°C (IEC 60695-2-1)
IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.

Class M2 in accordance with the Measuring Instrument Directive (MID). (2014/32/EU).

Class E2 in accordance with the Measuring Instrument Directive (MID), (2014/32/EU).


8/22 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters A series

such as the KNX adapter.


The A series meters ranges from single phase to
three phase meters and from basic up to ad- A series supports following instrumentation val-
vanced functionality without any comparison. ues dependent on version of meter:
The A series meters are mounted on a DIN rail and • Active energy
are suitable for installation in distribution boards • Current
and small enclosures such as consumer units. • Voltage
With the main terminals in accordance with DIN • Power factor
43857 and accessible from the below the meters, • Reactive power
the A series is suitable for many applications. • Total harmonic distortion
• Apparent power
The low rated or base currents of these products • Frequency
ensures high dynamic performance with superior • Harmonics
accuracy even at low currents. The meters sup-
8

port a wide voltage range as well as a wide tem- A series meters with a functionality level of Gold
perature range. The display is pixel-oriented and or Platinum have an internal clock for
can display up to four quantities at the same advanced functionality:
time. Navigating the meter is easily done via the • Event log
push-buttons below the display. To configure the • Previous values
meter settings, the set button must be accessed • Load profile
and this • Maximum and minimum demand
button is protected against unauthorized use
when the “glass lid” on the front of the meter The tariffs are controlled via inputs, via
is closed and sealed. The exceptional low power communication or via an internal clock in Gold and
consumption of the meters makes them Platinum versions.
economical in the long run - an important feature
specially for large meter populations.
The A series support up to four I/O’s. It can be
two inputs and two outputs in a fixed configura-
Data from the A series meters can be collected via
tion or four I/O points that are freely configured
pulse output or serial communication. The pulse
to input or output. Inputs can be used for count-
output is a solid state relay that generates pulses
ing pulses from e.g. a water meter, or reading sta-
proportionally to the measured energy. The me-
tus from external devices. Outputs can be used as
ters can also be equipped with built-in serial com-
pulse outputs or controlling external apparatus
munication interfaces for M-Bus or Modbus RTU
like
(RS-485). Meters with RS-485 interface can also
a contactor or an alarm (connected via an external
be set to communicate over the new EQ bus with
relay). The I/O’s need an external voltage supply.
the gateway G13. All meters in the A series come
The A series meters are type approved according
with an infrared port for communication with an
to IEC and they are both type approved and veri-
external Serial Communication Adapter (SCA)
fied according to MID. MID is the Measuring In-
struments Directive 2014/32/EU from the Euro-
pean Commission. MID type approval and
verification is mandatory for meters in billing ap-
plications within EU and EEA. The type approval is
according to standards that covers all relevant
technical aspects of the meter. These include cli-
mate conditions, electromagnetic compatibility
(EMC), electrical requirements, mechanical re-
quirements and accuracy.
8/23


Energy efficiency
Energy meters A series

Technical features
A series
Outputs
Type Transistor or MOSFET
Current 2 - 100 mA
Voltage 5 - 240 V AC/DC. For meters with only 1 output, 5 -
40 V DC.
A series Pulse output frequency Programmable: 1 - 999999 imp/kWh
Pulse length Programmable: 10 - 990 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
Inputs

8
Voltage 0 - 240 V AC/DC
OFF 0 - 5 V AC/DC
ON 57 - 240 V AC/24 - 240 V DC
Min. pulse lenght 30 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
Immunity to conducted disturbance 150 kHz - 80 MHz, (IEC 61000-4-6)
Immunity to disturbance with harmonics 2kHz - 150kHz
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards EC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-
22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21,
GB/T 17215.211-2006, GBT 17215.321-2008 class 1
& 2, GB/T 17215.322-2008 class 0,5 S, GB
4208-2008, EN 50470-1, EN 50470-3 category A, B &
C Energy meters.
Mechanical
Material Polycarbonate in transparent front glass, bottom
case, upper case and terminal cover, Glass
reinforced polycarbonate in terminal block.
Dimensions A41 / A42 A43 / A44
Width 70 mm 123 mm
Height 97 mm 97 mm
Depth 65 mm 65 mm
DIN modules 4 7
8/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters A series

Direct connected energy meter up to 80 A. Verified and approved according to MID. IEC
approval.Instrument values. Alarm function. Communication - Infrared (M-Bus).
Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters single phase electricity meter, 4 DIN with IR port, 80 A


Class B (Cl. 1) with functionality level Steel. Active energy

Description Bbn Order details Price Weight Pack


A41
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, Pulse output 705547 A41 111 - 2CMA170554R1000 0.230 1
100
8

57.7...288 V AC, Pulse output, RS-485 705004 A41 112 - 2CMA170500R1000 0.230 1
100
57.7...288 V AC, Pulse output, M-Bus 002400 A41 113 - 2CMA100240R1000 0.230 1
100
Class 1 (Reactive Class 2) with functionality level Silver. Active and
reactive energy, import/export, tariffs 1-4, tariff
controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, 2 output, 2 input, 705035 A41 312 - 2CMA170503R1000 0.230 1
RS-485 100
57.7...288 V AC, 2 output, 2 input. 705042 A41 313 - 2CMA170504R1000 0.230 1
M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Gold. Active
and reactive energy, import/export, tariffs 1-4, tariff
controlled via inputs, communication or clock, previous values, max and min demand.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, 2 output, 2 input, 705059 A41 412 - 2CMA170505R1000 0.230 1
RS-485 100
8/25


Energy efficiency
Energy meters A series

Transformer CTVT connected energy meter up to 6 A. Verified and approved according to


MID. IEC approval. Voltage V - 57...288 V AC. Instrument values. Alarm function.
Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus,
RS-485 EQ bus.

Energy meters single phase electricity meter, 4 DIN with IR port, 6 A


Class B (Cl. 1) with functionality level Steel. Active energy
A42
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, Pulse output 705554 A42 111 - 2CMA170555R1000 0.200 1
100

8
57.7...288 V AC, Pulse output, RS-485 705103 A42 112 - 2CMA170510R1000 0.200 1
100
57.7...288 V AC, Pulse output, M-Bus 002424 A42 113 - 2CMA100242R1000 0.200 1
100

Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, 2 output, 2 input, 705127 A42 312 - 2CMA170512R1000 0.200 1
RS-485 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Platinum. Active and reactive energy,
import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values,
max and min demand, advanced load profiles, harmonics and THD. Versions for 16.7, 50 or 60 Hz.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


57.7...288 V AC, Configurable 4 I/O 002387 A42 552 - 2CMA100238R1000 0.200 1
channels, RS-485 100
100...288 V AC, Configurable 4 I/O 705189 A42 552 - 2CMA100518R1000 0.200 1
channels, RS-485 16.7*, 50 or 60 Hz 120
100...288 V AC, Configurable 4 I/O 705196 A42 553 - 2CMA100519R1000 0.200 1
channels, M-Bus 16.7*, 50 or 60 Hz 120

*) The meters are not tested and approved for placement on rolling stock.
8/26 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters A series

Direct connected energy meter up to 80 A. Verified and approved according to MID. IEC
approval. 2- and 3-element metering. Instrument values. Alarm function. Communication -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters three phase electricity meter, 7 DIN with IR port, 80 A

A43 Class B (Cl. 1) with functionality level Steel. Active energy


Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 57.7/100...288/500 V AC, 705202 A43 111 - 2CMA170520R1000 0.440 1
Pulse output 100
8

3 x 57.7/100...288/500 V AC, 002448 A43 112 - 2CMA100244R1000 0.440 1


Pulse output, RS-485 100
3 x 57.7/100...288/500 V AC, 002455 A43 113 - 2CMA100245R1000 0.440 1
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze. Active and reactive energy, import/export.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 57.7/100...288/500 V AC, 705226 A43 212 - 2CMA170522R1000 0.440 1
Pulse output, RS-485 100
3 x 57.7/100...288/500 V AC, 705233 A43 213 - 2CMA170523R1000 0.440 1
Pulse output, M-Bus 100

Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 57.7/100...288/500 V AC, 705257 A43 312 - 2CMA170525R1000 0.440 1
2 output, 2 input, RS-485 100
3 x 57.7/100...288/500 V AC, 705264 A43 313 - 2CMA170526R1000 0.440 1
2 output, 2 input, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Platinum. Active and reactive energy,
import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous
values, max and min demand, advanced load profiles, harmonics and THD.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 57.7/100...288/500 V AC, 705318 A43 512 - 2CMA170531R1000 0.440 1
Configurable 4 I/O channels, RS-485 100
3 x 57.7/100...288/500 V AC, 705325 A43 513 - 2CMA170532R1000 0.440 1
Configurable 4 I/O channels, M-Bus 100
8/27


Energy efficiency
Energy meters A series

Transformer CTVT connected energy meter up to 6 A. Verified and approved according to MID.
IEC approval. 2- and 3-element metering. Instrument values. Alarm function. Communica-tion -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters three phase electricity meter, 7 DIN with IR port, 6 A


Class B (Cl. 1) with functionality level Steel. Active energy
A44
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705332 A44 111 - 2CMA170533R1000 0.350 1
Pulse output 100
3 x 57.7/100...288/500 V AC, 002486 A44 112 - 2CMA100248R1000 0.350 1
Pulse output, RS-485 100
3 x 57.7/100...288/500 V AC, 002493 A44 113 - 2CMA100249R1000 0.350 1

8
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze. Active and reactive energy, import/export.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 000130 A44 211 - 2CMA100013R1000 0.350 1
Pulse output 100
3 x 57.7/100...288/500 V AC, 705349 A44 212 - 2CMA170534R1000 0.350 1
Pulse output, RS-485 100
3 x 57.7/100...288/500 V AC, 705356 A44 213 - 2CMA170535R1000 0.350 1
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 2 output, 705363 A44 311 - 2CMA170536R1000 0.350 1
2 input 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Silver. Active and reactive
energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705370 A44 352 - 2CMA170537R1000 0.350 1
2 output, 2 input, RS-485 100
3 x 57.7/100...288/500 V AC, 705387 A44 353 - 2CMA170538R1000 0.350 1
2 output, 2 input, M-Bus 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Gold. Active and reactive energy, import/export,
tariffs 1-4, tariff controlled via inputs, communication or clock,previous values, max and min demand.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705400 A44 452 - 2CMA170540R1000 0.350 1
2 output, 2 input, RS-485 100
Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Platinum. Active and reactive
energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock,
previous values, max and min demand, advanced load profiles, harmonics and THD.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
EAN Type code Order code kg pc.
3 x 57.7/100...288/500 V AC, 705455 A44 552 - 2CMA170545R1000 0.350 1
Configurable 4 I/O channels, RS-485 100
3 x 57.7/100...288/500 V AC, 705462 A44 553 - 2CMA170546R1000 0.350 1
Configurable 4 I/O channels, M-Bus 100
3 x 57.7/100...400/690 V AC, 705493 A44 552 - 2CMA170549R1000 0.350 1
1 input + 1 output, RS-485 110
3 x 57.7/100...400/690 V AC, 705486 A44 553 - 2CMA170548R1000 0.350 1
1 input + 1 output, M-Bus 110
8/28 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters B series

Technical features
B21
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 220...240 VAC (-20% - +15%)
Power dissipation voltage circuits 1.1 VA (0.5 W) total at 230 V AC
Power dissipation current circuits 0.012 VA (0.012 W) at Iref and Ib
B series
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
Maximum current I max 65 A
8

Minimum current I min 0.25 A


Starting current I st < 20 mA
Terminal wire area 1 - 25 mm2
Recommended tightening torque 2 Nm
Communication
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
Transformer ratios
Configurable current ratio (CT) -
Pulse indicator (LED)
Pulse frequency 1000 imp/kWh
Pulse length 40 ms
General data
Frequency 50 or 60 Hz ± 5%
Accuracy Class B (Cl. 1) and Reactive Cl. 2
Active energy 1%
Display of energy 6 digit LCD
Environmental
Operating temperature -40°C - +70°C
Storage temperature -40°C - +85°C
Humidity 75% yearly average, 95% on 30 days/year
Resistance to fire and heat Terminal 960 °C, cover 650°C (IEC 60695-2-1)
Resistance to water and dust IP20 on terminal block without protective
enclosure and IP51 in protective enclosure,
according to IEC 60529.
Mechanical environment Class M2 in accordance with the Measuring
Instrument Directive (MID). (2014/32/EU).
Electromagnetic environment Class E2 in accordance with the Measuring
Instrument Directive (MID), (2014/32/EU).
8/29

B23 B24

3x230/400 V AC
3x220/380...240/415 VAC (-20% - +15%)
1.7 VA (0.8 W) total at 230 V AC
0.007 VA (0.007 W) per phase at Iref and Ib 0.0007 VA (0.0005 W) per phase at Iref and In
-
1A
-
0.05 A
6A

8
0.02 A
< 1 mA
0.5 - 10 mm2
1.2 Nm

1/9 - 9999/1

5000 imp/kWh

B (Cl. 1) or C (Cl. 0.5 S) and Reactive Cl. 2


0.5%, 1%
7 digit LCD

IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.

Class M2 in accordance with the Measuring Instrument Directive (MID). (2014/32/EU).

Class E2 in accordance with the Measuring Instrument Directive (MID), (2014/32/EU).


8/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters B series

The Energy meters, B series is a range of meters for single phase and three phase metering.
The B series meters are mounted on a DIN rail and are suitable for installation in distribution
boards and small enclosures such as consumer units. The B series are suitable in applications
where there is a need for reliable energy measurements and where space
is limited.

The low rated or base currents of these products ensures high dynamic performance with
superior accuracy even at low currents. The B series meters are meters for many
applications and installations. Navigating the meter is easily done via the push-buttons be-
low the display. To configure the meter settings, the set button must be accessed and this
button is protected against unauthorized use when the “glass lid” on the front of the meter
is closed and sealed. The exceptional low power consumption of the meters, less than 0.9 VA
and 1.6 VA, makes them economical in the long run - an important feature specially for large
8

meter populations.

Data from the B series meters can be collected via pulse output or serial communication. The
pulse output is a solid state relay that generates pulses proportionally to the measured en-
ergy. The meters can also be equipped with built-in serial communication interfaces for M-
Bus or Modbus RTU (RS-485). Meters with RS-485 interface can also be set to
communicate over the new EQ bus with the new gateway G13. All meters in the B series come
with an infrared port for communication with an external Serial Communication
Adapter (SCA) such as the KNX adapter.

The B series meters support reading of instrument values. A large number of electrical
properties can be read. Depending on version of the meter the following data is available:
• Active power
• Apparent power
• Reactive power
• Current
• Voltage
• Frequency
• Power factor

Up to 4 tariffs are controlled via inputs or communication.

The B series support two inputs and two outputs in a fixed configuration. Inputs can be used
for counting pulses from e.g. a water meter, or reading status from external devices. Out-
puts can be used as pulse outputs or controlling external apparatus like a contactor or an
alarm (connected via an external relay).

The B series meters are type approved according to IEC and they are both type approved and
verified according to MID. MID is the Measuring Instruments Directive 2014/32/EU from the
European Commission. MID type approval and verification is mandatory for meters in billing
applications within EU and EEA. The type approval is according to standards that covers all
relevant technical aspects of the meter. These include climate conditions, electromagnetic
compatibility (EMC), electrical requirements, mechanical requirements and accuracy.
8/31


Energy efficiency
Energy meters B series

Technical features
B series
Outputs

Type Transistor or MOSFET

Current 2 - 100 mA

Voltage 5 - 240 V AC/DC. For meters with only 1 output 5 -


40 VDC.
B series
Pulse output frequency Programmable 1 - 999999 imp/kWh

Pulse length Programmable 10 - 990 ms

Terminal wire area 0.5 - 1 mm2

Recommended tightening torque 0.25 Nm

8
Inputs

Voltage 0 - 240 V AC/DC

OFF 0 - 5 V AC/DC

ON 57 - 240 V AC/24 - 240 V DC

Min. pulse length 30 ms

Terminal wire area 0.5 - 1 mm2

Recommended tightening torque 0.25 Nm

EMC compatibility
Impulse voltage test 6 kV 1.2/50μs (IEC 60060-1)

Surge voltage test 4 kV 1.2/50μs (IEC 61000-4-5)

Fast transient burn test 4kV (IEC 61000-4-4)

Immunity to electromagnetic HF-fields 80 MHz - 2 GHz (IEC 61000-4-6)

Immunity to conducted disturbance 150kHz - 80MHz (IEC 61000-4-6)

Immunity to disturbance with harmonics 2kHz - 150kHz

Radio frequency emission EN 55022, class B (CISPR22)

Electrostatic discharge 15 kV (IEC 61000-4-2)

Standards IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class
0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-
2006, GB/T 17215.312-2008 class 1 & 2, GB/T 17215.322-
2008 class 0,5 S, GB 4208-2008, EN 50470-1, EN 50470-3
category A, B & C
Mechanical

Material Polycarbonate in transparent front glass. Glass


reinforced polycarbonate in bottom case and
upper case. Polycarbonate in terminal cover.
Dimensions B21 B23/B24

Width 35 mm 70 mm

Height 97 mm 97 mm

Depth 65 mm 65 mm

DIN modules 2 4
8/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters B series

Direct connected energy meter up to 65 A. Verified and approved according to MID. IEC
approval. Instrument values. Alarm function. - Communication - Infrared (M-Bus).
Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters single phase electricity meter, 2 DIN with IR port, 65 A


For direct connection up to 65 A. Class B (Cl. 1) with functionality level Steel.
Active energy

B21 Description Bbn Order details Price Weight Pack


7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


1 x 230 V AC, Pulse output 001496 B21 111 - 100 2CMA100149R1000 0.140 1
1 x 230 V AC, Pulse output, RS-485 001502 B21 112 - 100 2CMA100150R1000 0.150 1
8

1 x 230 V AC, Pulse output, M-Bus 001519 B21 113 - 100 2CMA100151R1000 0.150 1

For direct connection up to 65 A. Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver.
Active and reactive energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


1 x 230 V AC, 2 output, 2 input 001540 B21 311 - 100 2CMA100154R1000 0.140 1
1 x 230 V AC, 2 output, 2 input, 001557 B21 312 - 100 2CMA100155R1000 0.150 1
RS-485
1 x 230 V AC, 2 output, 2 input, M-Bus 001564 B21 313 - 100 2CMA100156R1000 0.150 1
8/33


Energy efficiency
Energy meters B series

Direct connected energy meter up to 65 A. Verified and approved according to MID. IEC
approval. 2- and 3-element metering. Instrument values. Alarm function. Communication -
Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters three phase electricity meter, 4 DIN with IR port, 65 A

Class B (Cl. 1) with functionality level Steel.


Active energy
B23
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, Pulse output 001632 B23 111 - 2CMA100163R1000 0.310 1

8
100
3 x 230/400 V AC, Pulse output, 001649 B23 112 - 2CMA100164R1000 0.320 1
RS-485 100
3 x 230/400 V AC, Pulse output, 001656 B23 113 - 2CMA100165R1000 0.330 1
M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze.
Active and reactive energy, import/export.

Description Bbn Order details Price Weight Pack


7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, Pulse output, 001663 B23 212 - 2CMA100166R1000 0.320 1
RS-485 100

Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver.


Active and reactive energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, 2 output, 001687 B23 311 - 2CMA100168R1000 0.330 1
2 input 100
3 x 230/400 V AC, 2 output, 001694 B23 312 - 2CMA100169R1000 0.340 1
2 input, RS-485 100
3 x 230/400 V AC, 2 output, 001700 B23 313 - 2CMA100170R1000 0.350 1
2 input, M-Bus 100
8/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters B series

Transformer CT connected energy meter up to 6 A. Verified and approved according to MID.


IEC approval. 2- and 3-element metering. Instrument values. Alarm function. Communication
- Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.

Energy meters three phase electricity meter, 4 DIN with IR port, 6 A

Class B (Cl. 1) with functionality level Steel. Active energy

B24 Description Bbn Order details Price Weight Pack


7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, Pulse output 001779 B24 111 - 2CMA100177R1000 0.250 1
100
8

3 x 230/400 V AC, Pulse output, 001786 B24 112 - 2CMA100178R1000 0.250 1


RS-485 100
3 x 230/400 V AC, Pulse output, 001793 B24 113 - 2CMA100179R1000 0.270 1
M-Bus 100

Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze.


Active and reactive energy, import/export.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, Pulse output, RS- 001809 B24 212 - 2CMA100180R1000 0.250 1
485 100

Class C (Cl. 0.5 S) (Reactive Cl. 2) with functionality level Silver.


Active and reactive energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, 2 output, 2 input, 001830 B24 352 - 2CMA100183R1000 0.270 1
RS-485 100
3 x 230/400 V AC, 2 output, 2 input, 001847 B24 353 - 2CMA100184R1000 0.290 1
M-Bus 100
8/35


Energy efficiency
Energy meters C series

The Energy meters, C series are truly compact meters for single phase and three phase
metering. The C series is mounted on a DIN rail and is suitable for installation in distribution
boards and small consumer units.

Only one or three module wide, the C series is a very compact meter for single phase
and three phase applications. The meters have an LCD with large digits showing energy
register and instrumentation values. The meters have a wide temperature range which
makes it possible to install the meters in many locations. Navigating the meters are easily
done via the push-button below the display. The exceptional low power consumption of the
meters, less than 0,3 W and 0,6 W at 230 V AC, makes them economical in the long run
- an important feature specially for large meter populations.

The C series meters support reading of instrument values. A number of electrical properties

8
can be read:
• Power factor
• Active power
• Current
• Voltage

The C series meters have an output that can be used as pulse output or alarm output.
The alarm quantity and levels is easily configured on the meter with the push button.
The output can be used for controlling external apparatus like a contactor or an alarm
indicator (connected via an external relay).

The C series meters are type approved according to IEC and MID. MID is the Measuring
Instruments Directive 2014/32/EU from the European Commission. The type
approval is according to standards that covers all relevant technical aspects of the meter.
These include climate conditions, electromagnetic compatibility (EMC), electrical
requirements, mechanical requirements and accuracy.

MID versions have initial verification according to annex F of the Measuring Instruments
Directive.
8/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters C series

Technical features
C11 C13
Voltage/current inputs
Nominal voltage 230 V AC 3x230/400 V AC
Voltage range 230 V AC (-20% - +15%) 3x230/400 V AC (-20% - +15%)
Power dissipation voltage circuits 7.4 VA (0.3 W) at 230 V 1.5 VA (0.6 W) total at 230 V
Power dissipation current circuits 0.04 VA (0.04 W) at Ib and Iref 0.04 VA (0.04 W) per phase at Ib
C series
and Iref
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
8

Maximum current I max 40 A


Minimum current I min 0.25 A

Starting current I st < 20 mA


Terminal wire area 0.5 - 10 mm2 0.5 - 10 mm2
Recommended tightening torque 0.8 Nm
General data
Frequency 50 or 60 Hz ± 5%
Accuracy Class B (Cl.1)
Active energy 1%
Display of energy 6 digit LCD 7 digits LCD
Communication
Terminal wire area -
Recommended tightening torque -
Pulse indicator (LED)
Pulse frequency 1000 (imp/kWh)
Pulse length 40 ms
Environmental
Operating temperature - 25°C - +70°C
Storage temperature - 25°C - +85°C
Humidity 75% yearly average, 95% on 30 days/year
Resistance to fire and heat Terminal 960°C, cover 650°C (IEC 60695-2-1)
Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in
protective enclosure, according to IEC 60529.
Mechanical environment Class M2 in accordance with the Measuring Instrument Directive
(MID). (2014/32/EU).
Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive
(MID), (2014/32/EU).
8/37


Energy efficiency
Energy meters C series

Technical features
C11 C13
Outputs
Type Transistor
Current 2 - 100 mA
Voltage 5 - 40 V DC
Pulse output frequency 100 or 1000 (imp/kWh)
Pulse length 100 ms
Terminal wire area 0.5 - 10 mm2 0.5 - 6 mm2
Recommended tightening torque 0.8 Nm 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)

8
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagneti 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
HF-fields
Immunity to conducted 150 kHz - 80 MHz, (IEC 61000-4-6)
disturbance
Immunity to disturbance with 2kHz - 150kHz
harmonics
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards IEC 62052-11, IEC 62053-21 class 1, GB/T 17215.211-2006, GBT
17215.321-2008 class 1, GB 4208-2008, EN 50470-1, EN 50470-3
category B
Mechanical
Material Glass reinforced polycarbonate
Dimensions
Width 17,5 mm 54 mm
Height 111 mm 122 mm
Depth 65 mm 65 mm
DIN modules 1 3
8/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201


Energy efficiency
Energy meters C series

Direct connected energy meter up to 40 A. IEC approval. Instrument values.


Alarm function. Optional - Verified and approved according to MID.D.

Energy meters single phase electricity meter, 1 DIN, 40 A

Class B (Cl.1) with functionality level Steel. Active energy


Description Bbn Order details Price Weight Pack
C11 7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


1 x 230 V AC, Pulse 035712 C11 110 - 2CMA103571R1000 0.070 1
output 1000 imp/kWh 101*)
Class 1 with functionality level Steel. Active energy
8

1 x 230 V AC, Pulse 035729 C11 110 – 2CMA103572R1000 0.070 1


output 1000 imp/kWh 301

Direct connected energy meter. IEC approval. 3 elementmetering. Instrument values.


Alarm function. Optional - Verified and approved according to MID.

Energy meters three phase electricity meter, 3 DIN, 40 A

For direct connection up to 40 A. Class B (Cl.1) with functionality level Steel. Active energy
C13
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit

EAN Type code Order code kg pc.


3 x 230/400 V AC, 035743 C13 110 - 2CMA103574R1000 0.170 1
Pulse output 1000 imp/kWh 101*)
For direct connection up to 40 A. Class 1 with functionality level Steel. Active energy
3 x 230/400 V AC, 035750 C13 110 - 301 2CMA103575R1000 0.170 1
Pulse output 1000 imp/kWh
*) MID approval according to Module
B and F
8/39


Energy efficiency
ABB EQmatic and Energy meters G series

Energy Analyzer, M-Bus, MDRC


NEW
Compact and web-based stand-alone devices for energy management applications.
For monitoring, logging, displaying and analyzing consumption data of up to 16 or
64 electricity, gas, water or heat meters via M-Bus. Automatic detection for ABB Energy
meters (A/B-Series). Access to the device via web browser. The user interface provides
graphical analysis functions, e.g. dashboard, historical data, instantaneous values, benchmark
functions, cost allocation according to consumer groups and more.

QA/S 3.16.1
Description Order details Price Weight Pack
1 piece 1 piece unit

EAN Type code Order code kg pc.

8
64 Devices 4016779997768 QA/S 3.64.1 2CDG110227R0011 0.15 1
16 Devices QA/S 3.16.1 2CDG110226R0011 0.15 1

QA/S 3.64.1

Energy Analyzer, Modbus RTU, MDRC


NEW
Compact and web-based stand-alone devices for energy management applications. For
monitoring, logging, displaying and analyzing consumption data of up to 16 or 64
electricity, gas, water or heat meters via Modbus RTU. Automatic detection for ABB Energy
meters (A/B-Se-ries). Access to the device via web browser. The user interface provides
graphical analysis functions, e.g. dashboard, historical data, instantaneous values,
benchmark functions, cost allocation according to consumer groups and more.
QA/S 4.xx.1
Description Order details Price Weight Pack
1 piece 1 piece unit

EAN Type code Order code kg pc.


Modbus RTU, 16 Devices QA/S 4.16.1 2CDG110228R0011 0.15 1
Modbus RTU, 64 Devices QA/S 4.64.1 2CDG110229R0011 0.15 1
8/15 8/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 41 9 0 05 C0201



Energy efficiency
Energy meters ABB EQmatic and Energy meters G series
The details make the difference
Energy meters G series
G13 is the Ethernet gateway that will make data collection from a meter network very conve-
nient. communication is performed using JSON (JavaScript Object Notation) on the Ethernet
side. The gateway is also equipped with a webserver that provides a detailed overview of all
meters installed in a network as well as the possibility to perform advanced configurations
of the meters and read-out data. High data security is obtained by encryption using SSL (Se-
cure Sockets Layer).
G13
Seals for terminals The gateway communicates with Energy meters over EQ bus, a communication protocol
based on the IEC standards (DLMS/cosem), using RS-485, and can also work as an M-Bus
master for M-Bus enabled ABB meters.

8
8
Communication protocols on the meter side: EQ bus over RS-485, M-Bus and ABB IR port.
Communication protocols on the system side: Ethernet with JSON. built-in webserver
for meter reading and meter management.

Description Order details Price Weight Pack


1 piece 1 piece unit

EAN Type code Order code kg pc.


100 - 240 V AC 7392696705523 G13 100-000 2CMA170552R1000 0.190 1

Infrared port for


DIN-Rail mounted
communication
and pro M design
between Meter Interface Module, KNX
communications It records consumption and measured values of the electrical energy consumption
MID approved
adapter and meter meters. Using an infra-red interface, the ABB energy meter types of the A- and B-series are
and verified
incorporated. The information and data which is read can be used, for example, for cost centre
accounting, energy optimisation, monitoring of installations and visualisation.

Description Order details Price Weight Pack


1 piece 1 piece unit

EAN Type code Order code kg pc.


KNX meter module 4016779662079 ZS/S 1.1 2CDG110083R0011 0.100 1
ZS/S 1.1

Pixel or Segment LCD


back-lit display

Configurable for both 3 Seals for access


and 4 wire networks to the SET button
ABB Kft.
—Energetikai Termékek Üzletág
ABB
E-mail: kisfeszultseg@hu.abb.com
Electrification BusinessVáci út 99.
Cím: 1139 Budapest,
BL Smart Buildings


new.abb.com/low-voltage/HU

abb.com/lowvoltage

Energy meters
A step toward environmental improvement
and fair cost allocation
9AKK107492A3149 - 05/2019

• MID Approved
• Reliable in harsh conditions
• Complete offer of functionalities
• Integrated in ABB Ability EDCS
© Copyright 2017 ABB. All rights reserved.
Specifications subject to change without notice.

You might also like