6625 Site Preparation
6625 Site Preparation
6625 Site Preparation
Site Preparation
B006-6663-A000
1207
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY
INTERFERENCE STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la
classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Information to User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that
interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference,
which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
CAUTION
NCR Corporation is not responsible for any radio or television interference caused by unauthorised
modifications of this equipment or the substitution or attachment of connecting cables and equipment
other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may
void the user’s authority to operate the equipment. The correction of interference caused by such
unauthorized modifications, substitutions, or attachments will be the responsibility of the user.
The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:
NOTICE
This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to
read it carefully.
It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications
and requirements of NCR and all applicable national, state, or local codes, regulations and laws.
Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are
hereby acknowledged.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available.
NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances,
photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office
for information that is applicable and current.
© 2007
By NCR Corporation, Dayton, Ohio U.S.A.
http://www.ncr.com
All Rights Reserved
Table of Contents
INTRODUCTION ...............................................................................................................1
How to Use This Site Preparation Bookset ....................................................................2
Purpose and Audience ....................................................................................................2
Site Compliance ..............................................................................................................2
Customer Responsibilities ..............................................................................................3
Product Identification .....................................................................................................4
PACKAGE DIMENSIONS.................................................................................................5
Manoeuvring the ATM Into Position..............................................................................6
ATM DIMENSIONS...........................................................................................................7
Standard Sleeve Without Collar .....................................................................................8
UL Security Enclosure ...............................................................................................8
CEN Security Enclosure ............................................................................................9
Short Sleeve Without Collar .........................................................................................10
UL Security Enclosure .............................................................................................10
CEN Security Enclosure ..........................................................................................11
Collar Dimensions ........................................................................................................12
Standard Collar ........................................................................................................12
Advert Collar............................................................................................................13
Lowered Height Collar.............................................................................................14
B006-6663-A000 i
Minimum Distance Between Two Installations.......................................................25
Exterior Wall Clearances ..............................................................................................26
Standard Collar ........................................................................................................26
Advert Collar............................................................................................................26
Lowered Height Collar.............................................................................................27
SEALING THE HOLE IN THE WALL AGAINST COLD AND WATER ....................39
VIDEO CAMERA.............................................................................................................47
Ambient Lighting..........................................................................................................47
Internal Space Constraint for Fitting a Third-Party Video Camera..............................48
ii B006-6663-A000
NCR 6625 ATM Site Preparation
Table of Contents
INTRODUCTION
The NCR 6625 Automated Teller Machine (ATM) may be installed through any suitable
exterior wall or vestibule location.
B006-6663-A000 1
NCR 6625 ATM Site Preparation
Site Compliance
This bookset contains the information necessary for the preparation of a site conforming to
NCR specifications. It is very important that the site complies with the requirements
specified in this bookset, because, once the equipment has been installed, deficiencies in
site preparation or the problems caused by these deficiencies are much more difficult to
detect and correct. Further, failure to comply with these requirements or to take proper
steps to protect equipment against risks identified in this bookset may cause serious
damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical wiring and
mechanical systems must also comply with all relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent who is fully conversant
with the special requirements of electronic equipment. The responsibility for ensuring that
the site is prepared in compliance with this bookset remains with the customer.
For information and guidance purposes only, a list is provided, in general terms, of those
matters for which the customer is responsible. This list is not intended to be
comprehensive, and in no way modifies, alters, or limits the responsibility of the customer
for all aspects of adequate site preparation.
2 B006-6663-A000
NCR 6625 ATM Site Preparation
NCR staff will be available to answer questions relating to the contents of this bookset but,
except where:
a the customer has been notified that a full or partial consultancy service is available
and/or that NCR will be willing to undertake a preliminary or final site survey and
b the customer shall have entered into a formal contract with NCR for provision of the
same
no comment, suggestion or advice offered or not offered about preparation of the site nor
any inspection of the site whether before or after preparation is to be taken as approval of
the location of the site and equipment or of its preparation and NCR will not be liable in
respect of any comment, suggestion or advice given by its staff or in respect of any failure
to give advice.
Finally, only the customer can know the full extent of damage which may be caused to his
business by reason of failure of the equipment which is to be installed. For this reason it is
the customer’s responsibility to ascertain the extent of any such possible damage to his
existing or planned business, and to effect, full insurance in respect of it.
Customer Responsibilities
The customer must do or provide the following:
When required by NCR, provide the NCR customer service representative with
appropriate drawings that indicate:
Location of the equipment
Site wiring (power and signal, paths and lengths)
Location of other equipment capable of generating electrical noise,
electromagnetic interference, heat, etc.
Make building alterations necessary to meet wiring and other site requirements.
Provide and install all communications cables, wall jacks, special connectors, and
associated hardware.
Provide and install necessary power distribution boxes, conduits, grounds, lightning
protection, and associated hardware.
Make sure all applicable codes, regulations and laws (including, but not limited to,
electrical, building, safety, and health) are met.
Provide and install auxiliary power or other equipment as required.
Provide storage or service areas as required.
Make sure the environmental requirements of the system/unit are met.
B006-6663-A000 3
NCR 6625 ATM Site Preparation
Provide floor coverings and environmental systems that limit or control static
electricity build-up and discharge.
Install the product at a height which meets the accessibility regulations of the relevant
country.
Product Identification
The product is identified by a class type number, 6625, and a 4 digit model number, which
is printed on a label fixed inside the top cabinet of the ATM. The serial number is unique
to each ATM. The tracer number is used to identify where the ATM was built. Please
quote all of the serial and tracer numbers, including the prefix, when making reference to
the ATM.
Made in UK
Vac: XXX Hz: 50/60 A:X.X
U® L
LISTED
649 ® LR 32207
Automated Teller Machine
24 Hour Service Level 1
Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.
Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescrites
dans le Reglement sur le brouillage radioelectrique du Canada.
4 B006-6663-A000
NCR 6625 ATM Site Preparation
PACKAGE DIMENSIONS
The dimensions of a packaged and unpackaged ATM are shown in the following
illustration.
977 mm
1435 mm (38.5 in.)
(56.5 in.)
1836 mm
(72.3 in.)
1405 mm
957 mm (55.3 in.)
(37.7 in.)
UL CEN
A Height of ATM and pallet 1648 mm 1657 mm
(64.9 in.) (65.2 in.)
B006-6663-A000 5
NCR 6625 ATM Site Preparation
Note 1: The dimensions assume the ATM is being moved using equipment that does not
extend beyond the ATM or packaging.
Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.
A B
6 B006-6663-A000
NCR 6625 ATM Site Preparation
ATM DIMENSIONS
The following illustrations show dimensions for ATMs configured with CEN Grade L,
CEN Grade I, CEN Grade III, CEN Grade IV Spanish Certified and UL 291 Level 1
security enclosures.
Note: Cables enter the ATM through the hole in the base of the ATM security enclosure.
Refer to page 41 for the location of the hole.
B006-6663-A000 7
NCR 6625 ATM Site Preparation
UL Security Enclosure
The illustration below shows the dimensions for a standard sleeve ATM configured with a
UL security enclosure. It shows the sleeve before a collar has been fitted.
747 mm
(29.4 in.)
803 mm
(31.6 in.)
36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)
742 mm 1301 mm
(29.2 in.) (51.2 in.)
1489 mm
(58.6 in.)
1160 mm
(45.7 in.)
831 mm
650 mm (32.7 in.)
536 mm (25.6 in.)
(21.1 in.)
8 B006-6663-A000
NCR 6625 ATM Site Preparation
747 mm
(29.4 in.) 803 mm
(31.6 in.)
36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)
742 mm
(29.2 in.) See Note 1
1498 mm
(59.0 in.)
1169 mm
(46.0 in.)
840 mm
659 mm (33.1 in.)
547 mm (25.9 in.)
(21.5 in.)
Note 1: For CEN I/CEN L this dimension is 1301 mm (51.2 in.), for CEN III and CEN
IV this dimension is 1309 mm (51.5 in.)
Note 2: For CEN I/CEN L this dimension is 865 mm (34.1 in.), for CEN III and CEN IV
this dimension is 883 mm (34.8 in.)
B006-6663-A000 9
NCR 6625 ATM Site Preparation
UL Security Enclosure
The illustration below shows the dimensions for a short sleeve ATM configured with a UL
security enclosure. It shows the sleeve before a collar has been fitted.
747 mm
(29.4 in.) 803 mm
(31.6 in.)
606 mm 100 mm
36 mm (23.9 in.) (3.94 in.)
(1.42 in.)
742 mm
1187 mm
(29.2 in.)
(46.7 in.)
250 mm 555 mm 312 mm 875 mm
(9.84 in.) (21.9 in.) (12.3 in.) (34.4 in.)
1489 mm
(58.6 in.)
1160 mm
(45.7 in.)
831 mm
650 mm (32.7 in.)
536 mm (25.6 in.)
(21.1 in.)
10 B006-6663-A000
NCR 6625 ATM Site Preparation
747 mm
(29.4 in.) 803 mm
(31.6 in.)
36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)
742 mm
(29.2 in.)
See Note 1
1498 mm
(59.0 in.)
1169 mm
(46.0 in.)
840 mm
659 mm (33.1 in.)
547 mm (25.9 in.)
(21.5 in.)
Note 1: For CEN I/CEN L this dimension is 1187 mm (46.7 in.), for CEN III and CEN
IV this dimension is 1195 mm (47.0 in.)
Note 2: For CEN I/CEN L this dimension is 865 mm (34.1 in.), for CEN III and CEN IV
this dimension is 883 mm (34.8 in.)
B006-6663-A000 11
NCR 6625 ATM Site Preparation
Collar Dimensions
Standard Collar
The illustration below shows the dimensions for an ATM configured with a standard
collar.
40 mm
(1.57 in.)
727 mm 75 mm 64 mm
(28.60 in.) (2.95 in.) (2.52 in.)
37.5 mm
(1.48 in.)
626 mm
(24.6 in.)
12 B006-6663-A000
NCR 6625 ATM Site Preparation
Advert Collar
The illustration below shows the dimensions for an ATM configured with an advert collar.
40 mm 75 mm
(1.57 in.) (2.95 in.)
278 mm
727 mm 37.5 mm
(10.9 in.)
(28.60 in.) (1.48 in.)
839 mm
(33.0 in.)
B006-6663-A000 13
NCR 6625 ATM Site Preparation
84 mm
727 mm 37.5 mm
(3.31 in.)
(28.60 in.) (1.48 in.)
210 mm
(8.27 in.)
855 mm 104 mm
(33.70 in.) (4.1 in.)
14 B006-6663-A000
NCR 6625 ATM Site Preparation
Height Depth
(from base of ATM) (from front of
collar)
740 mm 749 mm 99 mm
E SS Cash Exit (19.1 in.) (29.5 in.) (3.9 in.)
815 mm 824 mm 81 mm
F Audio Jack Plug (32.1 in.) (32.4 in.) (3.2 in.)
961 mm 970 mm 87 mm
G Card Reader (37.8 in.) (38.2 in.) (3.4 in.)
B006-6663-A000 15
NCR 6625 ATM Site Preparation
front
A B C D E F G H
16 B006-6663-A000
NCR 6625 ATM Site Preparation
50o
32o
381 mm (15 in.) Touchscreen 381 mm (15 in.) Touchscreen
B006-6663-A000 17
NCR 6625 ATM Site Preparation
C
A
D
E
Task Lighting
A minimum of 200 LUX is required for task lighting.
18 B006-6663-A000
NCR 6625 ATM Site Preparation
Wheelchair Clearance
The following illustration shows the clearance required for wheelchair approach and its
turning circle.
1524 mm
(60.0 in.)
1524 mm
(60.0 in.)
B006-6663-A000 19
NCR 6625 ATM Site Preparation
Note: Installing the ATM in the minimum servicing areas may impact servicing
and/or upgrading times.
20 B006-6663-A000
NCR 6625 ATM Site Preparation
Optimum Clearances
Standard Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and standard sleeve.
1474 mm
(58.0 in.)
320 mm
(12.6 in.)
1460 mm
(57.5 in.) Module
Tray
2614 mm
(103.0 in.)
460 mm 460 mm
(18.1 in.) (18.1 in.)
330 mm
(13.0 in.)
750 mm
(29.5 in.)
B006-6663-A000 21
NCR 6625 ATM Site Preparation
Short Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and short sleeve.
1474 mm
(58.0 in.)
320 mm
(12.6 in.)
1210 mm
(47.6 in.)
Dispenser
2360 mm
(92.9 in.)
460 mm 460 mm
(18.1 in.) (18.1 in.)
203 mm
(8.0 in.)
750 mm
(29.5 in.)
22 B006-6663-A000
NCR 6625 ATM Site Preparation
See Note 1
See Note 2
287 mm
(11.3 in.)
750 mm
(29.5 in.)
Note 1: For standard sleeve ATMs this dimension is 2614 mm (103.0 in.), for short
sleeve ATMs this dimension is 2360 mm (92.9 in.).
Note 2: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).
B006-6663-A000 23
NCR 6625 ATM Site Preparation
Minimum Clearances
The following illustrations show the minimum areas required for installing and servicing
the ATM. The illustration below shows the minimum clearance dimensions for an ATM
configured with a UL, or CEN, security enclosure with standard or short sleeve.
1233 mm
(48.5 in.)
380 mm 300 mm
(15.0 in.) (15.0 in.)
83 mm 553 mm 38 mm
(3.3 in.) (21.8 in.) (1.5 in.)
890 mm
(29.5 in.)
See Note 2
Minimum
Clearance
See Note 1
See Note 3
750 mm
(29.5 in.)
Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.
Note 2: For standard sleeve ATMs this dimension is 2044 mm (80.5 in.), for short sleeve
ATMs this dimension is 1930 mm (76.0 in.).
Note 3: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).
24 B006-6663-A000
NCR 6625 ATM Site Preparation
890 mm
(29.5 in.)
See Note 2
Minimum
Clearance
See Note 1
See Note 3
207 mm
(8.1 in.)
750 mm
(29.5 in.)
Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.
Note 2: For standard sleeve ATMs this dimension is 2044 mm (80.5 in.), for short sleeve
ATMs this dimension is 1930 mm (76.0 in.).
Note 3: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).
B006-6663-A000 25
NCR 6625 ATM Site Preparation
Standard Collar
10 mm
(0.4 in.)
45 mm
(1.8 in.)
30 mm 30 mm
(1.2 in.) (1.2 in.)
Advert Collar
45 mm
(1.8 in.)
30 mm 30 mm
(1.2 in.) (1.2 in.)
26 B006-6663-A000
NCR 6625 ATM Site Preparation
100 mm
(3.9 in.)
45 mm
(1.8 in.)
30 mm 30 mm
(1.2 in.) (1.2 in.)
B006-6663-A000 27
NCR 6625 ATM Site Preparation
In addition to the side panels there is a removable panel at the rear of the sleeve. The
monitor and bezel can also be unlatched and removed to allow access behind the facia
from the front.
28 B006-6663-A000
NCR 6625 ATM Site Preparation
Note: The collar cannot accommodate large dips or depressions in the wall.
+/- 4 mm
(0.2 in.)
0.0 mm
(0.0 in.)
+/- 4 mm
(0.2 in.)
B006-6663-A000 29
NCR 6625 ATM Site Preparation
Lowered Heights
The following installation heights have been designed to meet the regulations listed below
and therefore meet the requirements of both able-bodied and disabled people.
Note: To comply with ADA Accessibility Guidelines (ADAAG), July 2004, refer only to
the forward approach.
30 B006-6663-A000
NCR 6625 ATM Site Preparation
B006-6663-A000 31
NCR 6625 ATM Site Preparation
Installation Categories
Depending on the size of the hole that was cut for the previous installation, the 6625 ATM
can be installed through a new hole, an existing Personas 84 hole, or an existing Personas
87 hole in the wall.
Note: For ease of installation; NCR recommends a larger hole in the wall for new
installations.
The physical installation of the ATM is divided into the following categories:
1. Installation through a new hole in the wall:
at lowered height
at optimum height.
2. Installation through an existing hole in the wall
at lowered height
at optimum height.
32 B006-6663-A000
NCR 6625 ATM Site Preparation
625 mm
(24.6 in.)
744 mm
(29.3 in.) Hole in Wall
Lowered Height
of No. 5 Key
130 mm
A B (5.12 in.)
ATM Base
Sidewalk Plinth C
Installation Height
B006-6663-A000 33
NCR 6625 ATM Site Preparation
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must have the height that is specified in the table above.
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
34 B006-6663-A000
NCR 6625 ATM Site Preparation
625 mm
(24.6 in.)
130 mm
(5.12 in.)
1086 mm 1019 mm
(42.8 in.) (40.1 in.) ATM Base
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then, for
UL security enclosures, this dimension is 381 mm (15.0 in.) or for CEN security
enclosures, this dimension is 372 mm (14.6 in.).
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
B006-6663-A000 35
NCR 6625 ATM Site Preparation
744 mm
(29.3 in.) Hole in Wall
Lowered Height
of No. 5 Key
130 mm
A B (5.12 in.)
ATM Base
Sidewalk Plinth C
Installation Height
36 B006-6663-A000
NCR 6625 ATM Site Preparation
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must have the height that is specified in the table above.
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
B006-6663-A000 37
NCR 6625 ATM Site Preparation
610 mm
(24.0 in.)
130 mm
(5.12 in.)
1086 mm 1026 mm
(43.0 in.) (40.4 in.) ATM Base
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then, for
UL security enclosures, this dimension is 381 mm (15.0 in.) or for CEN security
enclosures, this dimension is 372 mm (14.6 in.).
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
38 B006-6663-A000
NCR 6625 ATM Site Preparation
B006-6663-A000 39
NCR 6625 ATM Site Preparation
Floor Covering
An antistatic floor covering should be used and must be of a type that will not generate
dust or fluff. The surface on which the ATM is to be sited should be level and even. In
locations where the floor may be uneven, it is recommended that a steel plate is used under
the ATM.
Floor Loading
The ATM must be installed on a floor capable of supporting the maximum weight. Only
the maximum weight should be considered as additional options may be added after
installation.
40 B006-6663-A000
NCR 6625 ATM Site Preparation
BOLT HOLES
The following illustrations show a plan of the base of the ATM (viewed from above) and
its relationship with the exterior wall. The plan should be used for pre-drilling bolt holes
‘A’ and illustrates the design of the steel plate, if used. If a plinth is used it should be no
smaller than the base of the ATM and it must be constructed of a material, and in such a
way, that it is capable of supporting the weight of the ATM (see page 40).
The definition of a plinth is a platform on to which the ATM is bolted. This plinth enables
the ATM to be installed at the required height through the wall.
B006-6663-A000 41
NCR 6625 ATM Site Preparation
470 mm
(18.50 in.)
60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)
135 mm 254 mm
(5.31 in.) (9.96 in.)
A A
800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.89 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.) Front of ATM
472 mm
(18.58 in.)
330 mm
(12.99 in.)
168 mm
(6.61 in.)
Security Enclosure
Hole in Wall
Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.
42 B006-6663-A000
NCR 6625 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a standard sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)
82 mm 265 mm 123 mm
(6.70 in.) (10.43 in.) (4.84 in.)
112 mm
(4.41 in.)
230 mm
(9.06 in.)
A B A
33 mm
A A (1.30 in.)
160 mm
(6.30 in.) Front of ATM
514 mm
(20.24 in.)
330 mm
(12.99 in.)
168 mm
(6.61 in.)
Security Enclosure
Hole in Wall
28 mm 28 mm
(1.1 in.) (1.1 in.)
45 mm x 20 mm 60 mm x 25 mm
(1.77 in.) (0.78 in.) (2.36 in.) (0.98 in.)
Counterbore Deep Counterbore Deep
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
B006-6663-A000 43
NCR 6625 ATM Site Preparation
470 mm
(18.50 in.)
60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)
135 mm 254 mm
(5.31 in.) (9.96 in.)
A A
800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.89 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.) Front of ATM
357 mm
(14.46 in.)
203 mm
(7.99 in.)
168 mm
(6.61 in.)
Security Enclosure
Hole in Wall
Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.
44 B006-6663-A000
NCR 6625 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a short sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)
82 mm 265 mm 123 mm
(6.70 in.) (10.43 in.) (4.84 in.)
112 mm
(4.41 in.)
230 mm
(9.06 in.)
A B A
33 mm
A A (1.30 in.)
160 mm
(6.30 in.) Front of ATM
400 mm
(15.75 in.)
203 mm
(7.99 in.)
168 mm
(6.61 in.)
Security Enclosure
Hole in Wall
28 mm 28 mm
(1.1 in.) (1.1 in.)
45 mm x 20 mm 60 mm x 25 mm
(1.77 in.) (0.78 in.) (2.36 in.) (0.98 in.)
Counterbore Deep Counterbore Deep
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
B006-6663-A000 45
NCR 6625 ATM Site Preparation
Security Bolts
To meet security standards the ATM must be bolted to the floor, through the ‘A’ holes,
using four bolts with anchor washers as specified below. The floor must be capable of
withstanding the loading imposed by the anchor points for the bolts. Bolts and anchor
washers are to be supplied by the owning organisation.
If an adjustable plinth is used, it must be bolted to the floor.
The minimum specification for bolts to secure the ATM to a concrete floor and meet
security standards, is high tensile M16 (5/8 in.) bolts with appropriate anchor washers of 6
mm (0.2 in.) minimum thickness. Bolts should be a minimum depth of 150 mm (5.9 in.)
and either resin anchor bolts or shield anchor type bolts.
Note 1: Bolting of CEN security enclosures should comply with the requirements of EN
1143-1 (CEN Safe Burglary Standard).
Note 2: For CEN L, CEN 1 and CEN III safes there is an additional fifth central
anchoring hole (hole ‘B’) of a larger counterbored diameter that can be used to fit a special
local alarm sensor.
46 B006-6663-A000
NCR 6625 ATM Site Preparation
VIDEO CAMERA
Ambient Lighting
If the ATM is fitted with a video camera, it is strongly recommended that there is a
minimum of 50 LUX lighting at floor level within the area illustrated below. This lighting
level conforms to:
Australian Standard for Automatic Teller Machines (1990)
Lighting for Automatic Teller Machines as prepared by Illuminating Engineering
Society of North America (1997).
1000 mm
(39.4 in.)
1500 mm
(59.1 in.)
B006-6663-A000 47
NCR 6625 ATM Site Preparation
56º
30 mm 60 mm
(1.2 in.) (2.4 in.)
60 mm
(2.4 in.) See Note
30 mm
(1.2 in.)
Note: For standard sleeve ATMs, this dimension is 180 mm (7.1 in.). For short sleeve
ATMs, this dimension is 150 mm (5.9 in.).
48 B006-6663-A000
To help NCR maintain the quality of their publications, send comments on the accuracy, clarity,
usability, navigation, organization, and value of this book.
Address correspondence to:
Surface mail address:
NCR Financial Solutions Group Ltd
Information Solutions
Kingsway West
Dundee
Scotland
DD2 3XX
Email address:
userfeedback@exchange.scotland.ncr.com