NCR 6625 ATMs

Site Preparation

B006-6663-A000
1207
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY
INTERFERENCE STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.

Canadian Class A Device Declaration


This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la
classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Information to User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that
interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference,
which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.

CAUTION
NCR Corporation is not responsible for any radio or television interference caused by unauthorised
modifications of this equipment or the substitution or attachment of connecting cables and equipment
other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may
void the user’s authority to operate the equipment. The correction of interference caused by such
unauthorized modifications, substitutions, or attachments will be the responsibility of the user.

The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:

• 2004/108/EC ‘EMC Directive’


• 93/68/EEC ‘CE Marking Directive’.
For further information, refer to the Electromagnetic Compatibility (EMC) and Safety section.

NOTICE
This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to
read it carefully.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications
and requirements of NCR and all applicable national, state, or local codes, regulations and laws.

The product described in this book is a licensed product of NCR Corporation.

NCR and Personas are trademarks of NCR Corporation.

Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are
hereby acknowledged.

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available.
NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances,
photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office
for information that is applicable and current.

© 2007
By NCR Corporation, Dayton, Ohio U.S.A.
http://www.ncr.com
All Rights Reserved
Table of Contents

NCR 6625 ATM Site Preparation

INTRODUCTION ...............................................................................................................1
How to Use This Site Preparation Bookset ....................................................................2
Purpose and Audience ....................................................................................................2
Site Compliance ..............................................................................................................2
Customer Responsibilities ..............................................................................................3
Product Identification .....................................................................................................4

PACKAGE DIMENSIONS.................................................................................................5
Manoeuvring the ATM Into Position..............................................................................6

ATM DIMENSIONS...........................................................................................................7
Standard Sleeve Without Collar .....................................................................................8
UL Security Enclosure ...............................................................................................8
CEN Security Enclosure ............................................................................................9
Short Sleeve Without Collar .........................................................................................10
UL Security Enclosure .............................................................................................10
CEN Security Enclosure ..........................................................................................11
Collar Dimensions ........................................................................................................12
Standard Collar ........................................................................................................12
Advert Collar............................................................................................................13
Lowered Height Collar.............................................................................................14

ACCESS FOR ALL...........................................................................................................15


Height and Depth to Main Facia Items .........................................................................15
Topmost Viewable Facia Item .................................................................................17
Facia Item Locations for Voice Guidance ....................................................................18
Task Lighting ................................................................................................................18
Wheelchair Clearance ...................................................................................................19

INSTALLATION AND SERVICE CLEARANCES........................................................20


Important Notice to Users.............................................................................................20
Optimum Clearances.....................................................................................................21
Standard Sleeve........................................................................................................21
Short Sleeve .............................................................................................................22
Optimum Distance Between Two Installations .......................................................23
Minimum Clearances ....................................................................................................24

B006-6663-A000 i
Minimum Distance Between Two Installations.......................................................25
Exterior Wall Clearances ..............................................................................................26
Standard Collar ........................................................................................................26
Advert Collar............................................................................................................26
Lowered Height Collar.............................................................................................27

SERVICE ACCESS PANELS AND FACIA APERTURE ..............................................28

HOLE IN THE WALL ......................................................................................................29


NCR Optimum Height ..................................................................................................29
Lowered Heights...........................................................................................................30
Centre for Accessible Environments in the UK (CAE) ...........................................30
Department of Justice Standard for Accessible Design (ADA)...............................30
Canadian Standards Association (CSA) ..................................................................30
Additional Lowered Heights.........................................................................................30
Australian Bankers’ Association..............................................................................31
Australian Standard Automated Teller Machines - User Access.............................31
United Nations Division for Social Policy and Development .................................31
Installation Categories ..................................................................................................32
Installing Through a Glass Wall ...................................................................................32

INSTALLING THROUGH A NEW HOLE .....................................................................33


New Hole Installation at Lowered Height ....................................................................33
New Hole Installation at Optimum Height ...................................................................35

INSTALLING THROUGH AN EXISTING HOLE .........................................................36


Existing Hole Installation at Lowered Height ..............................................................36
Existing Hole Installation at Optimum Height .............................................................38

SEALING THE HOLE IN THE WALL AGAINST COLD AND WATER ....................39

REQUIREMENTS FOR THE FLOOR.............................................................................40


Floor Covering ..............................................................................................................40
Floor Loading ...............................................................................................................40

BOLT HOLES ...................................................................................................................41


Standard Sleeve Bolt Hole Locations ...........................................................................42
Short Sleeve Bolt Hole Locations.................................................................................44
Security Bolts................................................................................................................46

VIDEO CAMERA.............................................................................................................47
Ambient Lighting..........................................................................................................47
Internal Space Constraint for Fitting a Third-Party Video Camera..............................48

ii B006-6663-A000
NCR 6625 ATM Site Preparation

Table of Contents

NCR 6625 ATM Site Preparation

INTRODUCTION

The NCR 6625 Automated Teller Machine (ATM) may be installed through any suitable
exterior wall or vestibule location.

B006-6663-A000 1
NCR 6625 ATM Site Preparation

How to Use This Site Preparation Bookset


The site preparation is part of the NCR 6625 Site Preparation Bookset. It acts both as a
specifications book, and also as a gateway to the other books in the bookset, which are:
Electrical and Protection Requirements (B006-6657)
Environmental and Planning Requirements (B006-6658)

Purpose and Audience


This book is intended for architects and those responsible for preparing a site prior to the
arrival of the ATM.
Site preparation details are given under the following main sections within this book:
Package Dimensions
ATM Dimensions
Access for All
Installation and Service Clearances
Hole in the Wall
Requirements for the Floor

Site Compliance
This bookset contains the information necessary for the preparation of a site conforming to
NCR specifications. It is very important that the site complies with the requirements
specified in this bookset, because, once the equipment has been installed, deficiencies in
site preparation or the problems caused by these deficiencies are much more difficult to
detect and correct. Further, failure to comply with these requirements or to take proper
steps to protect equipment against risks identified in this bookset may cause serious
damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical wiring and
mechanical systems must also comply with all relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent who is fully conversant
with the special requirements of electronic equipment. The responsibility for ensuring that
the site is prepared in compliance with this bookset remains with the customer.
For information and guidance purposes only, a list is provided, in general terms, of those
matters for which the customer is responsible. This list is not intended to be
comprehensive, and in no way modifies, alters, or limits the responsibility of the customer
for all aspects of adequate site preparation.

2 B006-6663-A000
NCR 6625 ATM Site Preparation

NCR staff will be available to answer questions relating to the contents of this bookset but,
except where:
a the customer has been notified that a full or partial consultancy service is available
and/or that NCR will be willing to undertake a preliminary or final site survey and
b the customer shall have entered into a formal contract with NCR for provision of the
same
no comment, suggestion or advice offered or not offered about preparation of the site nor
any inspection of the site whether before or after preparation is to be taken as approval of
the location of the site and equipment or of its preparation and NCR will not be liable in
respect of any comment, suggestion or advice given by its staff or in respect of any failure
to give advice.
Finally, only the customer can know the full extent of damage which may be caused to his
business by reason of failure of the equipment which is to be installed. For this reason it is
the customer’s responsibility to ascertain the extent of any such possible damage to his
existing or planned business, and to effect, full insurance in respect of it.

Customer Responsibilities
The customer must do or provide the following:
When required by NCR, provide the NCR customer service representative with
appropriate drawings that indicate:
Location of the equipment
Site wiring (power and signal, paths and lengths)
Location of other equipment capable of generating electrical noise,
electromagnetic interference, heat, etc.
Make building alterations necessary to meet wiring and other site requirements.
Provide and install all communications cables, wall jacks, special connectors, and
associated hardware.
Provide and install necessary power distribution boxes, conduits, grounds, lightning
protection, and associated hardware.
Make sure all applicable codes, regulations and laws (including, but not limited to,
electrical, building, safety, and health) are met.
Provide and install auxiliary power or other equipment as required.
Provide storage or service areas as required.
Make sure the environmental requirements of the system/unit are met.

B006-6663-A000 3
NCR 6625 ATM Site Preparation

Provide floor coverings and environmental systems that limit or control static
electricity build-up and discharge.
Install the product at a height which meets the accessibility regulations of the relevant
country.

Product Identification
The product is identified by a class type number, 6625, and a 4 digit model number, which
is printed on a label fixed inside the top cabinet of the ATM. The serial number is unique
to each ATM. The tracer number is used to identify where the ATM was built. Please
quote all of the serial and tracer numbers, including the prefix, when making reference to
the ATM.

Class: 6625 Model: XXXX


Serial: XX-XXXXXXXX
NCR Global Solutions Ltd.
Tracer: XX-XXXXX

Made in UK
Vac: XXX Hz: 50/60 A:X.X

U® L
LISTED
649 ® LR 32207
Automated Teller Machine
24 Hour Service Level 1

Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.

Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescrites
dans le Reglement sur le brouillage radioelectrique du Canada.

‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘

4 B006-6663-A000
NCR 6625 ATM Site Preparation

PACKAGE DIMENSIONS
The dimensions of a packaged and unpackaged ATM are shown in the following
illustration.

977 mm
1435 mm (38.5 in.)
(56.5 in.)

1836 mm
(72.3 in.)

1405 mm
957 mm (55.3 in.)
(37.7 in.)

UL CEN
A Height of ATM and pallet 1648 mm 1657 mm
(64.9 in.) (65.2 in.)

B006-6663-A000 5
NCR 6625 ATM Site Preparation

Manoeuvring the ATM Into Position


Ensure that doorways and corridors leading to your point of installation are wide enough
to allow the package to pass through, or make arrangements to unpack the ATM in an area
with sufficient access and then move it to the installation site. Also ensure that any
corridors can support the weight of the ATM. Refer to page 40 for the maximum weight of
the ATM and its floor loading.
The following table gives the minimum dimensions for doorways, corridors with right
angle corners and the space required to rotate an ATM on its axis.

Note 1: The dimensions assume the ATM is being moved using equipment that does not
extend beyond the ATM or packaging.

Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.

A B

Packaged ATM Packaged ATM Unpackaged


(pallet, carton (pallet and ATM
and lid) carton)
A Doorway or straight corridor 989 mm 969 mm 779 mm
(38.9 in.) (38.2 in.) (30.7 in.)
B Corridor with corner 1210 mm 1185 mm 1017 mm
(47.6 in.) (46.7 in.) (40.0 in.)
C Rotation about centre 1748 mm 1712 mm 1529 mm
(68.8 in.) (67.4 in.) (60.2 in.)

6 B006-6663-A000
NCR 6625 ATM Site Preparation

ATM DIMENSIONS
The following illustrations show dimensions for ATMs configured with CEN Grade L,
CEN Grade I, CEN Grade III, CEN Grade IV Spanish Certified and UL 291 Level 1
security enclosures.
Note: Cables enter the ATM through the hole in the base of the ATM security enclosure.
Refer to page 41 for the location of the hole.

B006-6663-A000 7
NCR 6625 ATM Site Preparation

Standard Sleeve Without Collar

UL Security Enclosure
The illustration below shows the dimensions for a standard sleeve ATM configured with a
UL security enclosure. It shows the sleeve before a collar has been fitted.

747 mm
(29.4 in.)
803 mm
(31.6 in.)

36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)

742 mm 1301 mm
(29.2 in.) (51.2 in.)

250 mm 555 mm 426 mm 875 mm


(9.84 in.) (21.9 in.) (16.8 in.) (34.4 in.)

1489 mm
(58.6 in.)
1160 mm
(45.7 in.)
831 mm
650 mm (32.7 in.)
536 mm (25.6 in.)
(21.1 in.)

151 mm 553 mm 800 mm


(5.94 in.) (21.8 in.) (31.5 in.)
837 mm
(33.0 in.)

8 B006-6663-A000
NCR 6625 ATM Site Preparation

CEN Security Enclosure


The illustration below shows the dimensions for a standard sleeve ATM configured with a
CEN Grade I, CEN Grade L, CEN Grade III or CEN Grade IV Spanish Certified security
enclosure. It shows the sleeve before a collar has been fitted.

747 mm
(29.4 in.) 803 mm
(31.6 in.)

36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)

742 mm
(29.2 in.) See Note 1

250 mm 555 mm 426 mm 875 mm


(9.84 in.) (21.9 in.) (16.8 in.) (34.4 in.)

1498 mm
(59.0 in.)
1169 mm
(46.0 in.)
840 mm
659 mm (33.1 in.)
547 mm (25.9 in.)
(21.5 in.)

151 mm 553 mm 800 mm


(5.94 in.) (21.8 in.) (31.5 in.)
See Note 2

Note 1: For CEN I/CEN L this dimension is 1301 mm (51.2 in.), for CEN III and CEN
IV this dimension is 1309 mm (51.5 in.)

Note 2: For CEN I/CEN L this dimension is 865 mm (34.1 in.), for CEN III and CEN IV
this dimension is 883 mm (34.8 in.)

B006-6663-A000 9
NCR 6625 ATM Site Preparation

Short Sleeve Without Collar

UL Security Enclosure
The illustration below shows the dimensions for a short sleeve ATM configured with a UL
security enclosure. It shows the sleeve before a collar has been fitted.

747 mm
(29.4 in.) 803 mm
(31.6 in.)

606 mm 100 mm
36 mm (23.9 in.) (3.94 in.)
(1.42 in.)
742 mm
1187 mm
(29.2 in.)
(46.7 in.)
250 mm 555 mm 312 mm 875 mm
(9.84 in.) (21.9 in.) (12.3 in.) (34.4 in.)

1489 mm
(58.6 in.)
1160 mm
(45.7 in.)
831 mm
650 mm (32.7 in.)
536 mm (25.6 in.)
(21.1 in.)

151 mm 553 mm 800 mm


(5.94 in.) (21.8 in.) (31.5 in.)
837 mm
(33.0 in.)

10 B006-6663-A000
NCR 6625 ATM Site Preparation

CEN Security Enclosure


The illustration below shows the dimensions for a short sleeve ATM configured with a
CEN Grade I, CEN Grade L, CEN Grade III or CEN Grade IV Spanish Certified security
enclosure. It shows the sleeve before a collar has been fitted.

747 mm
(29.4 in.) 803 mm
(31.6 in.)

36 mm 606 mm 100 mm
(1.42 in.) (23.9 in.) (3.94 in.)

742 mm
(29.2 in.)
See Note 1

250 mm 555 mm 312 mm 875 mm


(9.84 in.) (21.9 in.) (12.3 in.) (34.4 in.)

1498 mm
(59.0 in.)
1169 mm
(46.0 in.)
840 mm
659 mm (33.1 in.)
547 mm (25.9 in.)
(21.5 in.)

151 mm 553 mm 800 mm


(5.94 in.) (21.8 in.) (31.5 in.)
See Note 2

Note 1: For CEN I/CEN L this dimension is 1187 mm (46.7 in.), for CEN III and CEN
IV this dimension is 1195 mm (47.0 in.)

Note 2: For CEN I/CEN L this dimension is 865 mm (34.1 in.), for CEN III and CEN IV
this dimension is 883 mm (34.8 in.)

B006-6663-A000 11
NCR 6625 ATM Site Preparation

Collar Dimensions

Standard Collar
The illustration below shows the dimensions for an ATM configured with a standard
collar.

40 mm
(1.57 in.)
727 mm 75 mm 64 mm
(28.60 in.) (2.95 in.) (2.52 in.)

37.5 mm
(1.48 in.)

626 mm
(24.6 in.)

UL CEN Short Sleeve Standard Sleeve


A 1224 mm 1233 mm B 239 mm 353 mm
(48.2 in.) (48.5 in.) (9.41 in.) (13.9 in.)

12 B006-6663-A000
NCR 6625 ATM Site Preparation

Advert Collar
The illustration below shows the dimensions for an ATM configured with an advert collar.

40 mm 75 mm
(1.57 in.) (2.95 in.)

278 mm
727 mm 37.5 mm
(10.9 in.)
(28.60 in.) (1.48 in.)

839 mm
(33.0 in.)

UL CEN Short Sleeve Standard Sleeve


A 1438 mm 1447 mm B 239 mm 353 mm
(56.6 in.) (57.0 in.) (9.41 in.) (13.9 in.)

B006-6663-A000 13
NCR 6625 ATM Site Preparation

Lowered Height Collar


The illustration below shows the dimensions for an ATM configured with a lowered
height collar.
40 mm 75 mm
(1.57 in.) (2.95 in.)

84 mm
727 mm 37.5 mm
(3.31 in.)
(28.60 in.) (1.48 in.)

210 mm
(8.27 in.)

855 mm 104 mm
(33.70 in.) (4.1 in.)

UL CEN Short Sleeve Standard Sleeve


A 1453 mm 1462 mm B 239 mm 353 mm
(57.2 in.) (57.6 in.) (9.41 in.) (13.9 in.)

14 B006-6663-A000
NCR 6625 ATM Site Preparation

ACCESS FOR ALL


The ATM has been designed to meet the height and reach requirements of both able-
bodied and disabled, excluding the visually impaired. For wheelchair users, the ATM
offers optimised parallel approach, providing easy access, security and private space if
installed according to the specifications detailed in this document.

Height and Depth to Main Facia Items


The following tables give the height and depth to the main facia items located on the facia.
All the height dimensions are calculated from the base of the ATM.

Height Depth
(from base of ATM) (from front of
collar)

Facia Item UL CEN UL and CEN

305 mm (12.0 in.) 1008 mm 1017 mm 214 mm


A Touchscreen Display (top) (39.7 in.) (40.0 in.) (8.4 in.)
381 mm (15.0 in.) 1020 mm 1029 mm 220 mm
Touchscreen Display (top) (40.2 in.) (40.5 in.) (8.7 in.)
305 mm (12.0 in.) Display - 945 mm 954 mm 163 mm
B 1st FDK (centre) (37.2 in.) (37.6 in.) (6.4 in.)
381 mm (15.0 in.) Display - 952 mm 961 mm 168 mm
1st FDK (centre) (37.5 in.) (37.8 in.) (6.6 in.)
305 mm (12.0 in.) Display - 918 mm 927 mm 144 mm
C 2nd FDK (centre) (36.1 in.) (36.5 in.) (5.7 in.)
381 mm (15.0 in.) Display - 920 mm 929 mm 145 mm
2nd FDK (centre) (36.2 in.) (36.6 in.) (5.7 in.)
705 mm 714 mm 42 mm
JKL
D 5 No. 5 Key (27.8 in.) (28.1 in.) (1.7 in.)

740 mm 749 mm 99 mm
E SS Cash Exit (19.1 in.) (29.5 in.) (3.9 in.)

815 mm 824 mm 81 mm
F Audio Jack Plug (32.1 in.) (32.4 in.) (3.2 in.)

961 mm 970 mm 87 mm
G Card Reader (37.8 in.) (38.2 in.) (3.4 in.)

1070 mm 1079 mm 117 mm


H Receipt (42.1 in.) (42.5 in.) (4.6 in.)

B006-6663-A000 15
NCR 6625 ATM Site Preparation

front

A B C D E F G H

16 B006-6663-A000
NCR 6625 ATM Site Preparation

Topmost Viewable Facia Item


The following illustrations show the projected angle from the front of the standard or
advert collar and the lowered height collar to the topmost viewable facia item.

50o
32o
381 mm (15 in.) Touchscreen 381 mm (15 in.) Touchscreen

Standard or Advert Collar Lowered Height Collar

B006-6663-A000 17
NCR 6625 ATM Site Preparation

Facia Item Locations for Voice Guidance

C
A
D
E

Facia Item Distance from No. 5 Key Clock Face Position

305 mm (12.0 in.) Display 306 mm


10
- Top left-hand FDK (12.0 in.)
A
381 mm (15.0 in.) Display 333 mm
10
- Top left-hand FDK (13.1 in.)
446 mm
B Receipt Exit 1
(18.3 in.)
355 mm
C Card Reader 1
(14.0 in.)
264 mm
D Audio Jack Plug 2
(10.4 in.)
Cash Exit 184 mm
E 3
(7.2 in.)

Task Lighting
A minimum of 200 LUX is required for task lighting.

18 B006-6663-A000
NCR 6625 ATM Site Preparation

Wheelchair Clearance
The following illustration shows the clearance required for wheelchair approach and its
turning circle.

1524 mm
(60.0 in.)

1524 mm
(60.0 in.)

B006-6663-A000 19
NCR 6625 ATM Site Preparation

INSTALLATION AND SERVICE CLEARANCES

Important Notice to Users


If it is likely that the ATM will be upgraded with new modules as they become available,
you should use the optimum clearances.

Note: Installing the ATM in the minimum servicing areas may impact servicing
and/or upgrading times.

20 B006-6663-A000
NCR 6625 ATM Site Preparation

Optimum Clearances

Standard Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and standard sleeve.

1474 mm
(58.0 in.)

320 mm
(12.6 in.)

1460 mm
(57.5 in.) Module
Tray

2614 mm
(103.0 in.)

460 mm 460 mm
(18.1 in.) (18.1 in.)

330 mm
(13.0 in.)

750 mm
(29.5 in.)

B006-6663-A000 21
NCR 6625 ATM Site Preparation

Short Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and short sleeve.

1474 mm
(58.0 in.)

320 mm
(12.6 in.)

1210 mm
(47.6 in.)

Dispenser

2360 mm
(92.9 in.)

460 mm 460 mm
(18.1 in.) (18.1 in.)

203 mm
(8.0 in.)

750 mm
(29.5 in.)

22 B006-6663-A000
NCR 6625 ATM Site Preparation

Optimum Distance Between Two Installations


The optimum distance between the security enclosures of two ATMs, installed side by
side, is 460 mm (18.1 in.).
2487 mm
(97.9 in.)

See Note 1

460 mm 460 mm 460 mm


(18.1 in.) (18.1 in.) (18.1 in.)

See Note 2

287 mm
(11.3 in.)
750 mm
(29.5 in.)

Note 1: For standard sleeve ATMs this dimension is 2614 mm (103.0 in.), for short
sleeve ATMs this dimension is 2360 mm (92.9 in.).

Note 2: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).

B006-6663-A000 23
NCR 6625 ATM Site Preparation

Minimum Clearances
The following illustrations show the minimum areas required for installing and servicing
the ATM. The illustration below shows the minimum clearance dimensions for an ATM
configured with a UL, or CEN, security enclosure with standard or short sleeve.
1233 mm
(48.5 in.)
380 mm 300 mm
(15.0 in.) (15.0 in.)
83 mm 553 mm 38 mm
(3.3 in.) (21.8 in.) (1.5 in.)

890 mm
(29.5 in.)

See Note 2
Minimum
Clearance

See Note 1

See Note 3

750 mm
(29.5 in.)

Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.

Note 2: For standard sleeve ATMs this dimension is 2044 mm (80.5 in.), for short sleeve
ATMs this dimension is 1930 mm (76.0 in.).

Note 3: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).

24 B006-6663-A000
NCR 6625 ATM Site Preparation

Minimum Distance Between Two Installations


The minimum distance between two ATMs, installed side by side between the security
enclosures, is 380 mm (15.0 in.).
2167 mm
(85.3 in.)

380 mm 380 mm 300 mm


(15.0 in.) (15.0 in.) (15.0 in.)
83 mm 553 mm 553 mm 38 mm
(3.3 in.) (21.8 in.) (21.8 in.) (1.5 in.)

890 mm
(29.5 in.)

See Note 2
Minimum
Clearance

See Note 1

See Note 3

207 mm
(8.1 in.)
750 mm
(29.5 in.)

Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.

Note 2: For standard sleeve ATMs this dimension is 2044 mm (80.5 in.), for short sleeve
ATMs this dimension is 1930 mm (76.0 in.).

Note 3: For standard sleeve ATMs this dimension is 330 mm (13.0 in.), for short sleeve
ATMs this dimension is 203 mm (8.0 in.).

B006-6663-A000 25
NCR 6625 ATM Site Preparation

Exterior Wall Clearances


The illustrations below show the minimum clear wall area required around the collar for
installing and servicing the ATM.

Standard Collar

10 mm
(0.4 in.)

45 mm
(1.8 in.)

30 mm 30 mm
(1.2 in.) (1.2 in.)

Advert Collar

45 mm
(1.8 in.)

30 mm 30 mm
(1.2 in.) (1.2 in.)

26 B006-6663-A000
NCR 6625 ATM Site Preparation

Lowered Height Collar

100 mm
(3.9 in.)

45 mm
(1.8 in.)

30 mm 30 mm
(1.2 in.) (1.2 in.)

B006-6663-A000 27
NCR 6625 ATM Site Preparation

SERVICE ACCESS PANELS AND FACIA


APERTURE
For installations where there is enough room to stand at either side of the ATM, there are
two service access panels on the top-box, one at either side, as shown below. The panels
can be removed to allow easier access to the facia, keyboard and shutter areas.

In addition to the side panels there is a removable panel at the rear of the sleeve. The
monitor and bezel can also be unlatched and removed to allow access behind the facia
from the front.

28 B006-6663-A000
NCR 6625 ATM Site Preparation

HOLE IN THE WALL


The wall and floor need to be smooth and even as the collar has a tolerance of +/- 4 mm
(0.2 in. (+/- 0.5°)) at the top and bottom, with 0 mm (0.0 in. (0°)) at its centre. This is
shown in the following illustration.

Note: The collar cannot accommodate large dips or depressions in the wall.

+/- 4 mm
(0.2 in.)

0.0 mm
(0.0 in.)

+/- 4 mm
(0.2 in.)

NCR Optimum Height


This height assures the best display viewability for able-bodied people. It does not comply
with the regulations listed in the next section.
The height from sidewalk level to the base of the hole in the wall must be 1010 mm (39.8
in.). This means the ATM is installed with the number five key on the keyboard at 1086
mm (42.8 in.) from sidewalk level.

B006-6663-A000 29
NCR 6625 ATM Site Preparation

Lowered Heights
The following installation heights have been designed to meet the regulations listed below
and therefore meet the requirements of both able-bodied and disabled people.

Centre for Accessible Environments in the UK (CAE)


To ensure maximum user accommodation relative to the UK Design Guidelines “Access
to ATMs”, published by the Centre for Accessible Environments in the UK (CAE), the
ATM must be installed with the middle of the number five key on the keyboard, no higher
than 885 mm (34.8 in.) from sidewalk level. This ensures that the height of the highest
consumer interface element is no higher than 1250 mm (49.2 in.) from sidewalk level.

Department of Justice Standard for Accessible Design (ADA)


To comply with the Department of Justice Standard for Accessible Design, title III
regulation, the ATM must be installed for either:
Parallel approach, with the middle of the number five key on the keyboard no higher
than 1007 mm (39.6 in.) from sidewalk level. This ensures that the height of the
highest consumer interface element is no higher than 1372 mm (54.0 in.) from the
sidewalk level.
or
Forward approach, with the middle of the number five key on the keyboard no higher
than 855 mm (33.7 in.) from sidewalk level. This ensures that the height of the highest
consumer interface element is no higher than 1220 mm (48.0 in.) from sidewalk level.
The wheelchair clearance on page 19 shows adequate floor space for forward or parallel
approach. For minimum floor space for only forward or only parallel approach, refer to the
ADA Accessibility Guidelines and implement the appropriate forward or parallel height
requirements.

Note: To comply with ADA Accessibility Guidelines (ADAAG), July 2004, refer only to
the forward approach.

Canadian Standards Association (CSA)


To comply with the Canadian Standards Association (CSA), B651.1-01, 2004, the ATM
must be installed with the middle of the number five key on the keyboard, no higher than
835 mm (32.9 in.) from sidewalk level. This ensures that the height of the highest
consumer interface element is no higher than 1200 mm (47.2 in.) from sidewalk level.

Additional Lowered Heights


The following regulations have flexibility in their installation heights, providing that the
ATM is installed within the lower and higher limits listed below. As they do not need to be
installed at an exact height, they are not detailed in the sections that follow.

30 B006-6663-A000
NCR 6625 ATM Site Preparation

Australian Bankers’ Association


To comply with the Australian Bankers’ Association Industry Standard Automated Teller
Machine (ATM), the ATM must be installed to ensure that the lowest consumer interface
element is no less than 750 mm (29.5 in.) and the highest consumer interface element is no
higher than 1200 mm (47.2 in.) from sidewalk level.

Australian Standard Automated Teller Machines - User Access


To comply with the Australian Standard Automated Teller Machines - User Access,
AS 3769 - 1990, the ATM must be installed to ensure that the lowest consumer interface
element is no less than 685 mm (27.0 in.) and the highest consumer interface element is no
higher than 1370 mm (53.9 in.) from sidewalk level, and not less than 500 mm from an
internal corner.

United Nations Division for Social Policy and Development


To comply with the United Nations Division for Social Policy and Development, 2003 -
2004, the ATM must be installed to ensure that the lowest consumer interface element is
no less than 800 mm (31.5 in.) and the highest consumer interface element is no higher
than 1400 mm (55.1 in.) from sidewalk level.

B006-6663-A000 31
NCR 6625 ATM Site Preparation

Installation Categories
Depending on the size of the hole that was cut for the previous installation, the 6625 ATM
can be installed through a new hole, an existing Personas 84 hole, or an existing Personas
87 hole in the wall.

Note: For ease of installation; NCR recommends a larger hole in the wall for new
installations.

The physical installation of the ATM is divided into the following categories:
1. Installation through a new hole in the wall:
at lowered height
at optimum height.
2. Installation through an existing hole in the wall
at lowered height
at optimum height.

Installing Through a Glass Wall


If you are installing your ATM through a glass wall you may require a suitable glass
support (normally a steel collar) to sit between the ATM collar and the glass. The
requirement for this support should be determined by the architect. If required, any such
support should be sourced locally.

32 B006-6663-A000
NCR 6625 ATM Site Preparation

INSTALLING THROUGH A NEW HOLE

New Hole Installation at Lowered Height


It is the responsibility of the owning institution to ensure that the heights from the
sidewalk level to the facia items comply with any local regulations. For more information
on the installation heights and regulations refer to the earlier section “Lowered Heights”
on page 30.
For installing the ATM at lowered height, a lowered height collar is required.

625 mm
(24.6 in.)

744 mm
(29.3 in.) Hole in Wall

Lowered Height
of No. 5 Key

130 mm
A B (5.12 in.)

ATM Base

Sidewalk Plinth C

View from Inside Building


See Note 2

Installation Height

CAE ADA ADA and ADAAG CSA


parallel approach parallel approach forward approach parallel approach

Highest operable point 1250 mm 1372 mm 1220 mm 1200 mm


(49.2 in.) (54.0 in.) (48.0 in.) (47.2 in.)
A 885 mm 1007 mm 855 mm 835 mm
(34.8 in.) (39.6 in.) (33.7 in.) (32.9 in.)
B 830 mm 952 mm 800 mm 780 mm
(32.7 in.) (37.5 in.) (31.5 in.) (30.7 in.)
UL 180 mm 302 mm 150 mm 130 mm
C (7.0 in.) (11.9 in.) (5.9 in.) (5.1 in.)
(See Note 1) CEN 171 mm 293 mm 141 mm 121 mm
(6.7 in.) (11.5 in.) (5.6 in.) (4.8 in.)

B006-6663-A000 33
NCR 6625 ATM Site Preparation

Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must have the height that is specified in the table above.

Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.

34 B006-6663-A000
NCR 6625 ATM Site Preparation

New Hole Installation at Optimum Height


It is the responsibility of the owning institution to ensure that the heights from the
sidewalk level to the facia items comply with any local regulations. Where no such
regulations exist, the ATM can be installed at the NCR optimum height, as shown in the
following illustration.
For installing the ATM at optimum height either a standard, or advert, collar is required.
.

625 mm
(24.6 in.)

534 mm Hole in Wall


Optimum Height (21.0 in.)
of No. 5 Key

130 mm
(5.12 in.)

1086 mm 1019 mm
(42.8 in.) (40.1 in.) ATM Base

Plinth See Note 1


Sidewalk

View from Inside Building


See Note 2

Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then, for
UL security enclosures, this dimension is 381 mm (15.0 in.) or for CEN security
enclosures, this dimension is 372 mm (14.6 in.).

Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.

B006-6663-A000 35
NCR 6625 ATM Site Preparation

INSTALLING THROUGH AN EXISTING HOLE

Existing Hole Installation at Lowered Height


It is the responsibility of the owning institution to ensure that the heights from the
sidewalk level to the facia items comply with any local regulations. For more information
on the installation heights and regulations refer to the earlier section “Lowered Heights”
on page 30.
For installing the ATM at lowered height, a lowered height collar is required. The existing
plinth must be replaced with a new one.
610 mm
(24.0 in.)

744 mm
(29.3 in.) Hole in Wall
Lowered Height
of No. 5 Key

130 mm
A B (5.12 in.)

ATM Base

Sidewalk Plinth C

View from Inside Building


See Note 2

Installation Height

CAE ADA ADA and ADAAG CSA


parallel approach parallel approach forward approach parallel approach
Highest operable point 1250 mm 1372 mm 1220 mm 1200 mm
(49.2 in.) (54.0 in.) (48.0 in.) (47.2 in.)
A 885 mm 1007 mm 855 mm 835 mm
(34.8 in.) (39.6 in.) (33.7 in.) (32.9 in.)
B 830 mm 952 mm 800 mm 780 mm
(32.7 in.) (37.5 in.) (31.5 in.) (30.7 in.)
UL 180 mm 302 mm 150 mm 130 mm
C (7.0 in.) (11.9 in.) (5.9 in.) (5.1 in.)
(See Note 1) CEN 171 mm 293 mm 141 mm 121 mm
(6.7 in.) (11.5 in.) (5.6 in.) (4.8 in.)

36 B006-6663-A000
NCR 6625 ATM Site Preparation

Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must have the height that is specified in the table above.

Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.

B006-6663-A000 37
NCR 6625 ATM Site Preparation

Existing Hole Installation at Optimum Height


It is the responsibility of the owning institution to ensure that the heights from the
sidewalk level to the facia items comply with any local regulations. Where no such
regulations exist, the ATM can be installed at the NCR optimum height, as shown in the
following illustration.
For installing the ATM at optimum height either a standard or advert collar is required.
The existing plinth must be replaced with a new one.

610 mm
(24.0 in.)

518 mm Hole in Wall


Optimum Height (20.4 in.)
of No. 5 Key

130 mm
(5.12 in.)

1086 mm 1026 mm
(43.0 in.) (40.4 in.) ATM Base

Plinth See Note 1


Sidewalk

View from Inside Building


See Note 2

Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then, for
UL security enclosures, this dimension is 381 mm (15.0 in.) or for CEN security
enclosures, this dimension is 372 mm (14.6 in.).

Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.

38 B006-6663-A000
NCR 6625 ATM Site Preparation

SEALING THE HOLE IN THE WALL AGAINST COLD


AND WATER
To ensure that the temperature around the ATM is maintained during cold weather, it is
important that the wall opening is prepared correctly. Any cavity in the wall should not
extend into the wall opening. Cavities in the wall should be sealed to provide a flush
surface. The gap between the ATM sleeve and the wall opening should be left clear to
allow air at room temperature to circulate.
To enable a good weather seal to be made between the wall and the ATM facia, a 25 mm
(1.0 in.) wide smooth surface is required around the periphery of the wall opening.

Seal any cavity

Do not block air gaps

B006-6663-A000 39
NCR 6625 ATM Site Preparation

REQUIREMENTS FOR THE FLOOR


The ATM is suitable for mounting on concrete or other non-combustible surface only.

Floor Covering
An antistatic floor covering should be used and must be of a type that will not generate
dust or fluff. The surface on which the ATM is to be sited should be level and even. In
locations where the floor may be uneven, it is recommended that a steel plate is used under
the ATM.

Floor Loading
The ATM must be installed on a floor capable of supporting the maximum weight. Only
the maximum weight should be considered as additional options may be added after
installation.

CEN Grade III and


CEN Grade 1 and
UL CEN Grade IV
CEN Grade L
Spanish Certified
Maximum weight 562 kg 593 kg 711 kg
(1239.2 lb.) (1307.6 lb.) (1568 lb.)
Floor loading 1495 kg/m2 1577 kg/m2 1891 kg/m2
(306.1 lb./ft2) (323 lb./ft2) (387.3 lb./ft2)

40 B006-6663-A000
NCR 6625 ATM Site Preparation

BOLT HOLES
The following illustrations show a plan of the base of the ATM (viewed from above) and
its relationship with the exterior wall. The plan should be used for pre-drilling bolt holes
‘A’ and illustrates the design of the steel plate, if used. If a plinth is used it should be no
smaller than the base of the ATM and it must be constructed of a material, and in such a
way, that it is capable of supporting the weight of the ATM (see page 40).
The definition of a plinth is a platform on to which the ATM is bolted. This plinth enables
the ATM to be installed at the required height through the wall.

B006-6663-A000 41
NCR 6625 ATM Site Preparation

Standard Sleeve Bolt Hole Locations


UL Security Enclosure Bolt Hole Locations The illustration below shows the
dimensions for a standard sleeve ATM configured with a UL security enclosure.

470 mm
(18.50 in.)

60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)

135 mm 254 mm
(5.31 in.) (9.96 in.)
A A

800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.89 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.) Front of ATM

472 mm
(18.58 in.)
330 mm
(12.99 in.)

168 mm
(6.61 in.)

Security Enclosure

Hole in Wall

Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.

42 B006-6663-A000
NCR 6625 ATM Site Preparation

CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a standard sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)

82 mm 265 mm 123 mm
(6.70 in.) (10.43 in.) (4.84 in.)

112 mm
(4.41 in.)

230 mm
(9.06 in.)
A B A

800 mm 133 mm 271 mm


(31.50 in.) (5.24 in.) (10.67 in.)
410 mm
C (16.14 in.)

33 mm
A A (1.30 in.)

160 mm
(6.30 in.) Front of ATM

514 mm
(20.24 in.)
330 mm
(12.99 in.)

168 mm
(6.61 in.)

Security Enclosure

Hole in Wall

28 mm 28 mm
(1.1 in.) (1.1 in.)

45 mm x 20 mm 60 mm x 25 mm
(1.77 in.) (0.78 in.) (2.36 in.) (0.98 in.)
Counterbore Deep Counterbore Deep

Detail of Hole A Detail of Hole B


(All CEN Safes) (Not required on Spanish CEN IV)

Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.

Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.

B006-6663-A000 43
NCR 6625 ATM Site Preparation

Short Sleeve Bolt Hole Locations


UL Security Enclosure Bolt Hole Locations The illustration below shows the
dimensions for a short sleeve ATM configured with a UL security enclosure.

470 mm
(18.50 in.)

60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)

135 mm 254 mm
(5.31 in.) (9.96 in.)
A A

800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.89 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.) Front of ATM
357 mm
(14.46 in.)
203 mm
(7.99 in.)

168 mm
(6.61 in.)

Security Enclosure

Hole in Wall

Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.

44 B006-6663-A000
NCR 6625 ATM Site Preparation

CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a short sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)

82 mm 265 mm 123 mm
(6.70 in.) (10.43 in.) (4.84 in.)

112 mm
(4.41 in.)

230 mm
(9.06 in.)
A B A

800 mm 133 mm 271 mm


(31.50 in.) (5.24 in.) (10.67 in.)
410 mm
C (16.14 in.)

33 mm
A A (1.30 in.)

160 mm
(6.30 in.) Front of ATM
400 mm
(15.75 in.)
203 mm
(7.99 in.)

168 mm
(6.61 in.)

Security Enclosure

Hole in Wall

28 mm 28 mm
(1.1 in.) (1.1 in.)

45 mm x 20 mm 60 mm x 25 mm
(1.77 in.) (0.78 in.) (2.36 in.) (0.98 in.)
Counterbore Deep Counterbore Deep

Detail of Hole A Detail of Hole B


(All CEN Safes) (Not required on Spanish CEN IV)

Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.

Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.

B006-6663-A000 45
NCR 6625 ATM Site Preparation

Security Bolts
To meet security standards the ATM must be bolted to the floor, through the ‘A’ holes,
using four bolts with anchor washers as specified below. The floor must be capable of
withstanding the loading imposed by the anchor points for the bolts. Bolts and anchor
washers are to be supplied by the owning organisation.
If an adjustable plinth is used, it must be bolted to the floor.
The minimum specification for bolts to secure the ATM to a concrete floor and meet
security standards, is high tensile M16 (5/8 in.) bolts with appropriate anchor washers of 6
mm (0.2 in.) minimum thickness. Bolts should be a minimum depth of 150 mm (5.9 in.)
and either resin anchor bolts or shield anchor type bolts.

Note 1: Bolting of CEN security enclosures should comply with the requirements of EN
1143-1 (CEN Safe Burglary Standard).

Note 2: For CEN L, CEN 1 and CEN III safes there is an additional fifth central
anchoring hole (hole ‘B’) of a larger counterbored diameter that can be used to fit a special
local alarm sensor.

46 B006-6663-A000
NCR 6625 ATM Site Preparation

VIDEO CAMERA

Ambient Lighting
If the ATM is fitted with a video camera, it is strongly recommended that there is a
minimum of 50 LUX lighting at floor level within the area illustrated below. This lighting
level conforms to:
Australian Standard for Automatic Teller Machines (1990)
Lighting for Automatic Teller Machines as prepared by Illuminating Engineering
Society of North America (1997).

1000 mm
(39.4 in.)

1500 mm
(59.1 in.)

B006-6663-A000 47
NCR 6625 ATM Site Preparation

Internal Space Constraint for Fitting a Third-Party Video


Camera
The ATM can be ordered with a video camera in either PAL or NTSC format. However, if
a camera is not configured and a third-party video camera is to be installed, there is a
space constraint to consider. The following illustration shows the space constraint
dimensions.
A list of cameras that will fit within this space constraint can be found in the ATMs
Feature Descriptions (B006-6451) book.

56º

30 mm 60 mm
(1.2 in.) (2.4 in.)

60 mm
(2.4 in.) See Note

30 mm
(1.2 in.)

Note: For standard sleeve ATMs, this dimension is 180 mm (7.1 in.). For short sleeve
ATMs, this dimension is 150 mm (5.9 in.).

48 B006-6663-A000
To help NCR maintain the quality of their publications, send comments on the accuracy, clarity,
usability, navigation, organization, and value of this book.
Address correspondence to:
Surface mail address:
NCR Financial Solutions Group Ltd
Information Solutions
Kingsway West
Dundee
Scotland
DD2 3XX
Email address:
userfeedback@exchange.scotland.ncr.com

You might also like