NSFC01-01 CONTROL SYSTEM{4SW)
1. Special Precautions....................................................................................... 1
9. Troubleshooting ........................................................................................... 10
NSFC01-01 INSTRUCTION MANUAL
1、Special Precautions
. The type NSFC01-01 is the same as AAD0302
. Do not open or remove the front cover while the Variable
Frequency Drive is running. You may get an electrical shock.
. When necessary to perform inspections or when wiring the
unit, switch power off and wait at least 3 minutes and until
the bus charge light is off. Check for residual voltage.
. Do not attempt to inspect or wire this unit unless fully competent
to perform the work.
. Be sure hands are dry before operating any switches.
. Be sure cables do not have scratches, excessive stress,
. Be sure all connections are in accordance with instructions
in this manual
. Check that cables are properly connected before turning
equipment on.
. Do not allow metal fragments, conductive bodies, oil or other
flammable substance to enter the variable frequency drive.
. Do not modify this equipment
2、Terminal Function
Name Cable code Function description
(color )
L/N/ PE Brown /blue Single phase power supply
/(yellow&green)
U/V/W U/V/W* Motor terminal
1 2# Input signal: open door (NO)
2 3# Input signal: close door(NO)
3 --* Input signal: open limit(NC)
4 --* Input signal: close limit(NC)
8 1# Input signal commonality(COM)
C2-C3 4# Limit output commonality
B2 5# Output signal: open limit(NC)
B3 6# Output signal: close limit (NC)
C1 Error output commonality(COM)
B1 standby \Error output signal :break contact(NC)
A1 Error output signal: make contact(NO)
Notice : the cable with sign *has been connected in door system , the 7 wires control cable should
be connected to main control system by user
3、Keypad &Operation
3. 1 Keypad Definition
Name Function
To switch Mode:dr 、fr & parameter type : p、n
Go down one level in menu navigation ;confirm values after editing
scroll up numeric values & parameter
scroll down numeric values & parameter
Start key commands the drive to enable and start
Stop key commands to stop and disable ,or reset error
1 V2006-00
NSFC01-01 INSTRUCTION MANUAL
Press to return
to operation preparation
Notice :parameter type d is behind parameter type p . when get parameter type p, continue
to press button , can get parameter d.
2 V2006-00
NSFC01-01 INSTRUCTION MANUAL
4、Connection Diagrams
er: f:::;,, #
&
,--,,
er:: f
Q_
B1 ICi\tlL 3#
/11 CJP,\J I IMIT( ,pt)
L, ,
0
3 LI CJ I l lMIT( rput)
4 !er 1 fI
6
I- c ose shift
7
1#
PCJVJrn cc:
figure 1
Notice :
[1] Make control line and power line separately when connect to main controller.
[2] To be sure the match of the open/close door output logic of door controller and the Open/close
door input signal logic of main controller, when connect to the signal of Open/close.
The initial status of door controller is normal close(NC).
User can select relevant logic status:
Terminal A2—open limit, normal open(NO).
Terminal A3—close limit, normal open(NO).
Terminal (C2-C3)---limit output, signal common terminal.
3 V2006-00
NSFC01-01 INSTRUCTION MANUAL
Figure 2
notice:
[1] high-speed section of open usually is the same section as: d17=d19, at this point the
acceleration/ deceleration parameter: d32 is void.
[2] To keep frequency of door opening completed is d21 and the current is d40.
Keep time is d42,and the range is 0.1 to 999(s) ,when d42 is set as 0,it will
be keep forever .
[3] If opening torque of low-speed is small, the value of P05 can be increased
appropriately.but more current course system protect
4 V2006-00
NSFC01-01 INSTRUCTION MANUAL
Figure 3
Notice :
[1] high-speed section of open usually is the same section as: d24=d26, at this point the
acceleration/ deceleration parameter: d38 is void.
[2] To keep frequency of door opening completed is d14 and the current is d41.
Keep time is d42,and the range is 0.1 to 999(s) ,when d42 is set as 0,it will
be keep forever .
[3] If opening torque of low-speed is small, the value of P05 can be increased
appropriately. but more current course system protect
6、Basic procedure 1
Before the door controller is sent out from factory, the Autotune of door width pulses
and function parameters are completed. If user requires getting preferable running
curve, he can modify the corresponding parameters refer to fig.2 & fig. 3.
Procedure is:
6.1 To set control mode is keypad control: p08=1.
6.2 Refer to fig.2 & fig.3 and corresponding parameters (page:4,5), to get better capability through
adjusting door running curve.
6.3 Press +RUN or +RUN (first press button and then press RUN button,following
operation is the same ) to examine the running curve.
6.4 Set control mode become terminal control: P08=2( default )
NOTICE: if the controller is running, P08 can not be changed. first please press “STOP” key,
then press “MODE” key switch to parameter “P” and find P08 to modify
5 V2006-00
NSFC01-01 INSTRUCTION MANUAL
7、 Basic procedure 2
When the motor shift switch or logic of limit switch(NO/NC) is changed,
Or autotune the door width pulses is done again. The following procedure must to be sure.
7.1 Confirmation of the I/O signal (parameter n16,n17).monitor.
Parameter n16 is the monitor of input signal, it includes: ①~⑨。
Parameter n17 is the monitor of output signal, it includes: Open limit output signal, close limit
output signal, error output signal.
notice:[1] If motor dose not run, to increase properly the value of parameter P05.
[2] If the rotation direction is not right, to change motor phases.
6 V2006-00
NSFC01-01 INSTRUCTION MANUAL
P08
0 Keypad mode(RUN/STOP)
1 Keypad mode( +RUN—open, +RUN—close, STOP)
2 Terminal mode(NO:1--open、2--close)
3 Communication (RS 485)
7 V2006-00
NSFC01-01 INSTRUCTION MANUAL
P30 MONITOR SELECT 0 0-1 1 - R
P31 LINE 3.0 0.1-100 10 Multiple R/W
P32 MAX.OUTPUT VOLTAGE 0 0-500 1 VAC R
P33 OCS LEVEL 140 1-200 1 % R
P34 CARRIER FREQUENCY 5 0-8 1 Code R
P35 COMMUNICATION 1 1-31 1 - R
STATION
P36 COMMUNICATION SPEED 5 4-6 1 Code R
P37 STOP BIT 1 1-2 1 Bit R
P38 PARITY BIT 0 0-2 1 - R
P39 COMMUNICATION 0.0 0.0-60.0 10 s R
P40 COMMUNICATION 1 1-999 1 ms R
RESPOND TIME
8 V2006-00