Injection Pump Test Specifications
Injection Pump Test Specifications
Injection Pump Test Specifications
MANUFACTURER KUBOTA
INJECTION
PUMP 094500-864#
ENGINE TYPE V2403-M-T
INJECTION TIMING
Rotation — (Pre-stroke check)
Clockwise viewed from drive side (Delivery quantity adjustment)
Pre - stroke (mm) 3.15 ± 0.05 mm = PS (A = A0 + 0.30), (PS – 1.70) ± 0.10 mm (A = Max.)
TEST CONDITIONS
Nozzle : 093400-0540 (DN12SD12A) Test Oil : SAE J967 (ISO4113)
+0.98
Nozzle Opening Pressure : 13.73 MPa ( 140.0 +10 kgf/cm2) High Pressure Pipe : Ø2 × Ø6 × 600 mm
0 0
Feed Pressure : 30.0 ± 5.0 kPa ( 0.3 ± 0.1 kgf/cm2) Fuel Temperature : 40 - 45°C (104 - 113°F)
NOTE :
1. Setting injection quantity using specified rack value. ‘A’ dimension
A0 : The distance from the center of the knock-pin to the center
of the rack fork.
* The jig fix the dimension A as 12.20 mm ( = A0).
(Refer to diagram 1 for ‘A’ dimension measurement details.)
A : Set the rack to A0 + 1.50 mm using the jig.
This is the specified value A.
Adjust all cylinders so that the injection quantity at Np = 1300 rpm,
A = (A0 + 1.50) ± 0.05 is 48.6 ± 2.0 mm3/st (9.7 ± 0.4 cc/200st).
2. Using the jig, set the rack to A – 7.20 (A0 – 5.70). With the rack in this position,
comfirm that injection quantity for all cylinders is at the specified value.
- side ‘A’ dimension + side
represents the cam box
diagram 1
2009.06.12