Acceleration Enveloping
Acceleration Enveloping
Acceleration Enveloping
Acceleration envelope measurements were taken on Inadequate lubrication, which can encompass insufficient
same day. Note that 1Xrpm is missing in Figure 2 due to quantity, excessive quantity, and/or improper
the filtering used (30k-600k cpm). Also, note the low noise specifications, can be readily identified using acceleration
floor and the lack of bearing frequencies in the spectrum. envelope measurements. This phenomenon manifests
This bearing had recently been installed, no defects were itself as a shifting of the noise floor. Properly installed and
identifiable, and the lubrication is adequate for continued operating bearings will not necessarily generate specific
operation. bearing defect frequencies when an inadequate
lubrication condition exists.
1010 East Main Street, League City, TX 77573 Phone: 281.334.0766 Fax: 281.334.4255
www.stiweb.com / www.stiwebstore.com
Copyright © 2012 STI Vibration Monitoring, Inc.
CONCLUSION
1010 East Main Street, League City, TX 77573 Phone: 281.334.0766 Fax: 281.334.4255