Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Acceleration Enveloping

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Field Application Note

Acceleration Envelope ENV

Acceleration envelope measurements are a new


introduction to the inventory available to vibration analysts.
Although initially it would seem to be most useful for
detecting rolling element bearing defects (BPFO, BPFI,
BSF, FTF), much more can be performed once the
frequency ranges and applications of other more
traditional vibration parameters are considered. Once it is
understood how acceleration envelope signals are As the running speed components and their harmonics
processed, nearly all analysis could be accomplished with become larger along with the presence of higher order
these signals. Phenomena associated with motor electrical harmonics the "ringing" associated with these
and gear meshing problems fall into the frequency range harmonically related frequency components fall into the
of acceleration envelope processing. Unbalance and other frequency range of the acceleration envelope
lower order problems do not initially fall into envelope measurements. Running speed frequencies are now
analysis, but as these problems degrade they can be present in acceleration envelope measurements. Figures
detected. 3 and 4 illustrate this phenomenon.

Acceleration envelope signatures are essentially band


passed signals where lower order and higher order
frequencies are removed. The remaining frequency range
is most commonly associated with bearing defect
frequencies. Normally, running speed related frequencies
are removed by the filters and are not present in
acceleration envelope spectra. However, when a running
speed order frequency becomes severe enough it will The velocity spectrum, figure 3, has a much larger 1Xrpm
appear in the envelope signature. This is due to the frequency component which now appears in the
presence of numerous harmonics of the lower order acceleration envelope spectrum, figure 4.
frequency, which are not detectable in velocity signals,
falling into the envelope filter range.

Figures 1 and 2 illustrate that when lower velocity signals


are present the running speed components will not be
present in acceleration envelope signatures. These
spectra were collected on the same day during a routine
PM data collection visit.
LUBRICATION

Lubrication problems, not normally analyzed with velocity


signatures, but can sometimes be detected in
acceleration signatures, can readily be detected using
acceleration envelope signatures. Experience has shown
that an inadequate lubrication condition will cause a shift
in the noise floor of the signature.

Acceleration envelope measurements were taken on Inadequate lubrication, which can encompass insufficient
same day. Note that 1Xrpm is missing in Figure 2 due to quantity, excessive quantity, and/or improper
the filtering used (30k-600k cpm). Also, note the low noise specifications, can be readily identified using acceleration
floor and the lack of bearing frequencies in the spectrum. envelope measurements. This phenomenon manifests
This bearing had recently been installed, no defects were itself as a shifting of the noise floor. Properly installed and
identifiable, and the lubrication is adequate for continued operating bearings will not necessarily generate specific
operation. bearing defect frequencies when an inadequate
lubrication condition exists.

1010 East Main Street, League City, TX 77573 Phone: 281.334.0766 Fax: 281.334.4255
www.stiweb.com / www.stiwebstore.com
Copyright © 2012 STI Vibration Monitoring, Inc.
CONCLUSION

Acceleration Envelope measurements, due to the signal


filtering, can be used to identify more machinery defects
than damaged rolling element bearings. This
measurement parameter is commonly only used to
identify the smaller frequencies associated with bearing
defects.

If machinery defects are classified into lower order


problems and higher order problems they can be
effectively diagnosed with acceleration enveloping
Figure 5 illustrates how a lubrication problem can be measurements. Lower order problems would be
identified. The left portion of the spectra has been balance, misalignment, looseness due to fasteners, or
elevated with overall amplitudes of 1.1 G's. Once the looseness due to worn bearings. Higher order problems
bearing was greased the elevated portion shifted back would be bearing defect frequencies, motor bar pass
down, figure 6. Overall amplitudes were reduced to 0.7 frequencies, or gearmesh frequencies.
G's.
The presence of lower order problems in envelope
spectra indicate a severe problem which most likely will
need immediate attention. The filtering will eliminate
these frequencies from an otherwise healthy machine.

Tracking of higher order problems can be accomplished


normally using envelope measurements.

Sometimes the entire noise floor is elevated when a


lubrication problem exist, as illustrated in figures 7 and 8.
Figure 7 shows the elevated noise floor. No identifiable
bearing defect frequencies are present, only an elevated
noise floor. Overall amplitudes were at 8.2 G's.

Figure 8 was collected after the bearing was lubricated.


Note that bearing defect frequencies are not present and
the noise floor has dropped. The overall amplitude
dropped to 1.1 G's.

1010 East Main Street, League City, TX 77573 Phone: 281.334.0766 Fax: 281.334.4255
www.stiweb.com / www.stiwebstore.com
Copyright © 2012 STI Vibration Monitoring, Inc.