TechMasters Programming & Operating Instructions
TechMasters Programming & Operating Instructions
IU_TechMaster_02_eng Page 3 of 32
Information about TechMaster
Using your keypad
Slide/Change
Confirm/Enter
Four consecutive invalid codes initiates four minutes delay period. During this period
LCD will display the message “Penalty” when any operation will be performed.
Programming TechMaster
All the following programming instructions of TechMaster must be intended for only
one lock (this also includes Master and Manager codes). If your TechMaster has
more than one lock you must repeat the instructions for each installed lock.
Multiple Locks
Time Delay
Dallas keys
Can be set on each lock, requires code and key. Available for all Manager and Users
(not available for the Master).
TechMaster only works with Dallas keys coded by Tecnosicurezza.
Long audio and visual signals during opening indicate low battery.
Emergency battery
Remote Disable
IU_TechMaster_02_eng Page 5 of 32
Audit
Each Lock will record last 900 operations with time & date, user and function.
Override Reopening
Important notes
1. Master Menu
Power up TechMaster.
MASTER MENU
Press . LCD will display the message: XXXXXXXX
Power up TechMaster and access the Master Menu. LCD will display SET
the message: TIME AND DATE
08:00 FRI
Press . LCD will display current time and date. 27/01/2006
hh:mm ___
Press to modify Time and Date. DD / MM / YYYY
Page 6 of 32 IU_TechMaster_02_eng
Enter new values for time and date and press to confirm.
TIME LOCK
Power up TechMaster and access the Master Menu. Press two
times.
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
press .
ADD
Press . LCD will display the message:
! hh:mm DAY
Press . LCD will display the current day of the week. " hh:mm
! hh:mm DAY
" hh:mm
Press to confirm. LCD will display the next day of the week, and
At the end of the week LCD will display the message: END OF LIST
EXIT AND SAVE? ü
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
VERIFY OR
Press , LCD will display the message: DELETE
! hh:mm DAY
Press , LCD will display the set values for the first day. " hh:mm
DELETE?
Press to delete the set values. LCD will display the message: ü
END OF LIST
At the end of the list press .
Time Lock Standard week is an Opening Time Period: the safe door can be opened if you
enter a valid code (for ex. Opening Period from 08:00 to 14:00: the door can be opened from
08:00 to 14:00, but can’t be opened at 16:00).
You can enter four different Time Periods for each day (for ex. MON from 07:00 to 10:00;
from 12:00 to 13:00; from 15:00 to 16:00; from 18:00 to 19:00).
Time Periods will be saved just after confirmation pressing . It is recommended to set
the values with safe door open.
All the Users will be automatically added to their related Time Lock table.
Page 8 of 32 IU_TechMaster_02_eng
Use this function to add Special Events values.
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
SPECIAL EVENTS
Press three times.
ADD
Press , LCD will display the message:
The first one is the closing time and date and the second one is the opening time and date.
Enter Closing and Opening time and date, then press to confirm.
If a value for Year is set, this Special Event will cease after that date.
If a value for Year is not set, this Special Event will repeat every year.
Up to 30 Special Events are available for a maximum of nine (9) days each.
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
SPECIAL EVENTS
Press three times.
ADD
Press , LCD will display the message:
VERIFY OR
Press , LCD will display the message: DELETE
IU_TechMaster_02_eng Page 9 of 32
Press to scroll all the set values.
DELETE?
Press to delete the set values. LCD will display the message: ü
END OF LIST
At the end of the list press .
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
OPENING PERIODS
Press four times.
ADD
Press . LCD will display the message:
! DD/MM/YY hh:mm
Press . LCD will display the message: " DD/MM/YY hh:mm
The first one is the opening time and date and the second one is the closing time and date.
Enter Opening and Closing time and date, then press to confirm.
If a value for Year is set, this Opening Period will cease after that date.
If a value for Year is not set, this Opening Period will repeat every year.
During Opening Periods it will be possible to open the safe’s door even if Time Lock is active.
Up to 30 Opening Periods are available for a maximum of nine (9) days each.
Page 10 of 32 IU_TechMaster_02_eng
STANDARD WEEK 1
Power up TechMaster and access the Time Lock menu. Press .
OPENING PERIODS
Press four times.
ADD
Press , LCD will display the message:
VERIFY OR
Press , LCD will display the message: DELETE
! DD/MM/YY hh:mm
Press , LCD will display the first saved Opening Period. " DD/MM/YY hh:mm
DELETE?
Press to delete the set values. LCD will display the message: ü
END OF LIST
At the end of the list press .
1.3. PC Link
Use this function to start the communication between TechMaster and PC (audit, settings).
PC LINK
Press to start the communication with the PC. ACTIVE . . . . .
Use this function to add, disable or delete Manager, OVR Manager and Remote Manager.
IU_TechMaster_02_eng Page 11 of 32
Power up TechMaster and access the Master Menu. MANAGERS
MANAGEMENT
Press three times. LCD will display the message:
1: MANAGER ü
Press . LCD will display the message: 2: OVR MANAGER
ü
01 ü T1
Select the Manager entering his number and press to confirm. DISABLE?
LCD will display the message:
01 ü T1
Press to select the operation: enable, disable, delete or exit and DELETE?
press to confirm.
OPERATION
Press to confirm. LCD will display the message: DONE
Use this function to enable or disable the use of Dynamic Codes on the lock.
Power up TechMaster and access the Master Menu. DYNAMIC
CODES
Press four times. LCD will display the message:
STATUS:
Press . LCD will display the actual status: DISABLED/ENABLED
STATUS:
Press . LCD will display the message: ENABLE?/ DISABLE?
OPERATION
Press to confirm. DONE
If you want to disable the use of Dynamic Codes from all the locks STATUS:
REMOVE FROM ALL
press until LCD will display the message:
OPERATION
Press to confirm and remove the use of Dynamic Codes from all DONE
the locks.
If the use of Dynamic Codes has been removed and you want to activate it again, be sure
Dynamic Code option is enabled on the lock and use the Red Dallas and the key activation
code generated by the software to activate the function.
Page 12 of 32 IU_TechMaster_02_eng
2. Manager Menu
Power up TechMaster.
MANAGER MENU
Press and then press . LCD will display the message: XXXXXX
Use this function to install, delete, enable or disable or disable Users on the lock.
01 02 03 04
Press to check the list of Users or enter a User ID to select a ü ü ü ü
user.
01 ü T1
Press . LCD will display the message: DISABLE?
Use this function to set, modify or verify Time Delay and Open Window values.
IU_TechMaster_02_eng Page 13 of 32
T. DELAY 00
Press to confirm. LCD will display current values for time delay O. WINDOW 01
and open window.
T. DELAY mm
Press to exit or to set new values. O. WINDOW mm
VALUES
Enter new values for Time Delay and Open Window and press UPDATED
to confirm. LCD will display the message:
Accepted values are: 00÷99min for Time Delay and 01÷19min for Open Window.
To set a lower Time Delay value than the currently set on the lock, the lock must be opened.
If the lock is closed it won’t accept the new entered values. Open the lock and then set new
Time Delay values.
Power up TechMaster and access the Variable Time Delay menu. ADD
Enter values for starting time and ending time in which Variable Time
Delay will be active and then enter the values of Variable Time Delay.
Press to confirm. LCD will display the next day of the week, and
At the end of the week LCD will display the message: END OF LIST
EXIT AND SAVE? ü
Page 14 of 32 IU_TechMaster_02_eng
Press to save settings or to get back to the first day.
To add Variable Time Delay values, the lock must be opened. If the lock is closed it will be
not possible to access the function. Open the lock and then set Variable Time Delay values.
Variable Time Delay always have to be increased or decreased in steps of 10 minutes from
the value of Time Delay (2.2.). If not, TechMaster will automatically adjust values to the next
available ones.
After saving the settings LCD will display the message: ADD
Press .
VERIFY OR
Press , LCD will display the message: DELETE
08:00 SUN
Press , LCD will display the set values for the first day. 10:00 : 01
DELETE?
Press to delete the set values. LCD will display the message: ü
END OF LIST
At the end of the list press .
2.4. PC Link
Use this function to start the communication between TechMaster and PC (audit, settings).
PC LINK
Press to start the communication with the PC. ACTIVE . . . . .
IU_TechMaster_02_eng Page 15 of 32
Press at the end of the operation, to close the communication.
Power up TechMaster.
Depending on lock configuration you could find this menu inside Master menu or
inside Manager menu
Use this function to install, delete, enable or disable or disable OVR Users on the lock.
50 51 52 53
Press to check the list of OVR Users or enter a OVR User ID to ü ü ü ü
select a user.
52 ü T1
Press . LCD will display the message: DISABLE?
Power up TechMaster.
CHANGE
Press and then press three times. LCD will display the CODE
message:
Use this function to change Users and OVR Users code. Always perform this operation with
the door opened.
Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:
OLD CODE
Press to confirm. LCD will display the message: XX–XXXXXX
Enter the old code. LCD will display the message: NEW CODE
XXXXXX
Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX
Use this function to change Manager code. Always perform this operation with the door
opened.
Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:
CHANGE MANAGER
Press . LCD will display the message: CODE
IU_TechMaster_02_eng Page 17 of 32
OLD CODE
Press to confirm. LCD will display the message: XXXXXX
Enter the old code. LCD will display the message: NEW CODE
XXXXXX
Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX
Use this function to change OVR Manager code. Always perform this operation with the door
open.
Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:
CHANGE OVR
Press two times. LCD will display the message: MANAGER CODE
OLD CODE
Press to confirm. LCD will display the message: XXXXXX
Enter the old code. LCD will display the message: NEW CODE
XXXXXX
Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXX
Confirm the new code.
Use this function to change Master code. Always perform this operation with the door open.
Power up TechMaster System and access the Change Code Menu. CHANGE USER
CODE
Press . LCD will display the message:
CHANGE MASTER
Press three times. LCD will display the message: CODE
OLD CODE
Press to confirm. LCD will display the message: XXXXXXXX
Enter the old code. LCD will display the message: NEW CODE
Page 18 of 32 IU_TechMaster_02_eng
XXXXXXXX
Enter the new code. LCD will display the message: CONFIRM CODE
XXXXXXXX
5. Time Menu
Power up TechMaster.
TIME
Press and then press four times. LCD will display the MENU
message:
Use this function to delay the beginning of Time Lock up to 2 hours more than programmed
Time Lock.
MANAGER CODE
If you hold the Manager code press . LCD will display the XXXXXX
message:
Enter the User code (or enter the Manager code). LCD will display the OPENING
message: EXTENSION
OPENED UNTIL:
Press . If Time lock is programmed, LCD will display the next 12/09 20:30
Time Lock activation time (automatically calculated adding 2 hours to
Time Lock activation time):
Press to confirm.
If you want to enter different values enter new values for time and OPENED UNTIL:
DD/MM hh:mm
date (max. 2 hours), then press to confirm.
If no time lock period is programmed the function can’t be used. LCD TIMELOCK NOT
will display the message: PROGRAMMED
IU_TechMaster_02_eng Page 19 of 32
5.2 Immediate Time Lock
MANAGER CODE
If you hold the Manager code press . LCD will display the XXXXXX
message:
Enter the User code (or enter the Manager code). LCD will display the OPENING
message: EXTENSION
IMMEDIATE
Press . LCD will display the message: TIME LOCK
CLOSED UNTIL:
Press . If Time lock period is programmed, LCD will display the 14/09 08:00
next Time Lock opening period:
Press to confirm.
If you want to enter different values enter new values for time and CLOSED UNTIL:
DD/MM hh:mm
date (max. 2 weeks), then press to confirm.
If no time lock period is programmed it will be only possible to enter CLOSED UNTIL:
new values: enter new values for time and date (max. 2 weeks), then DD/MM hh:mm
press to confirm.
6. Configuration Menu
Power up TechMaster.
CONFIGURATION
Press and then press five times. LCD will display the XXXXXX
message:
Page 20 of 32 IU_TechMaster_02_eng
6.1. Install Locks
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
SELECT
Press and select the lock to install. LOCK=
If lock is already installed, LCD will display the message: LOCK ALREADY
INSTALLED
If lock is not connected to the keypad, LCD will display the message: LOCK X
DOES NOT ANSWER
If the selected lock is connected, LCD will display the message: MASTER CODE
XXXXXXXX
LOCK X
Enter Master code or press if the Master code is the default INSTALLED
code (1 2 3 4 5 6 7 8). LCD will display the message:
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
REMOVE
Press . LCD will display the message: LOCKS
SELECT
Press and select a lock to remove. LOCK=
MASTER CODE
Press to confirm. LCD will display the message: XXXXXXXX
If lock is not connected to the keypad, LCD will display the message: LOCK X
DOES NOT ANSWER
IU_TechMaster_02_eng Page 21 of 32
Then the following message will be displayed: CONTINUE?
LOCK X
Press to confirm. REMOVED
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
LCD
Press two times. LCD will display the message: CONTRAST
ADJUST CONTRAST
Press . LCD will display the message: X
6.4. Language
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
LANGUAGE
Press three times. LCD will display the message:
LANGUAGE
Press . LCD will display the current set language. ENGLISH
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
Page 22 of 32 IU_TechMaster_02_eng
MEMBRANE TEST
Press four times. LCD will display the message:
1234567890 ü
Press . LCD will display the message:
Press all the buttons in the displayed order: a double beep indicates
the button is ok, a long beep indicates the button is broken.
Power up TechMaster and access the Configuration Menu. LCD will INSTALL
display the message: LOCKS
SYSTEM INFO
Press five times. LCD will display the message:
7.1. Users (or OVR Users): Opening the lock without Time Delay
Power up TechMaster and select the lock when two or more locks are installed.
LCD will display the message: USER CODE
XX–XXXXXX
Enter a valid user code and insert the Dallas key, if set-up. LCD will OPEN
display the message:
Invalid code will prompt LCD to display the message WRONG CODE
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
7.2. Users (or OVR Users): Opening the lock with Time Delay
Power up TechMaster and select the lock when two or more locks are installed.
IU_TechMaster_02_eng Page 23 of 32
LCD will display the message: USER CODE
XX–XXXXXX
Enter a valid user code and insert the Dallas key, if set-up. LCD will TIME DELAY
display Time Delay counting time: 00:59
Invalid code will prompt LCD to display the message WRONG CODE
STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?
SELECT
To operate with other locks press during Time Delay counting LOCK:
After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01
USER CODE
Press , LCD will display the message: XX–XXXXXX
Enter a valid user code and insert the Dallas key, if set-up. LCD will OPEN
display the message:
Invalid code will prompt LCD to display the message WRONG CODE
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
7.3. Manager (or OVR Manager): Opening the lock without Time Delay
Power up TechMaster and select the lock when two or more locks are installed.
MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:
Enter Manager code and insert the Dallas key, if set-up (or OVR OPEN
Manager code and insert the Dallas key, if set-up). LCD will display
the message:
Page 24 of 32 IU_TechMaster_02_eng
Invalid code will prompt LCD to display the message WRONG CODE
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
7.4. Manager (or OVR Manager): Opening the lock with Time Delay
Power up TechMaster and select the lock when two or more locks are installed.
MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:
Enter Manager code and insert the Dallas key, if set-up. (or OVR TIME DELAY
Manager code and insert the Dallas key, if set-up). LCD will display 00:59
Time Delay counting time:
Invalid code will prompt LCD to display the message WRONG CODE
STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?
SELECT
To operate with other locks press during Time Delay counting LOCK:
After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01
USER CODE
Press , LCD will display the message: XX–XXXXXX
MANAGER CODE
Press to open with Manager code (or press it two times to open XXXXXX
with OVR Manager code), LCD will display the message:
Enter Manager code and insert the Dallas key, if set-up (or OVR OPEN
Manager code and insert the Dallas key, if set-up). LCD will display
the message:
IU_TechMaster_02_eng Page 25 of 32
Invalid code will prompt LCD to display the message WRONG CODE
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
7.5. Opening the lock with Dynamic Codes (Dallas key option)
Power up TechMaster (select the lock if two or more locks are installed).
Insert the Dynamic User Dallas Key. LCD will display the message: DYNAMIC USER
XXXX
Invalid Dynamic code will prompt the LCD to display the message: WRONG
DYNAMIC CODE
If the Dynamic Code is entered 30 minutes before his activation time DYNAMIC CODE
LCD will display the message: BROUGHT FORWARD
If the Dynamic Code is entered 30 minutes after his activation time DYNAMIC CODE
LCD will display the message: EXPIRED
Dynamic Codes must be used respecting the sequence of activation DYNAMIC CODE
time in which they have been created by the software, otherwise the UNUSABLE
last created code will delete all the previous ones (i.e. if three codes
are created and the third one is used before the first and the second
ones, the two first codes will be deleted). LCD will show the message:
Enter the Dynamic Code. LCD will display the message: OPEN
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
Page 26 of 32 IU_TechMaster_02_eng
7.6. Opening the lock with Dynamic Codes (PIN option)
Press and hold button number 1. LCD will display the message: PIN
XXXX
Enter your four digits PIN. LCD will display the message: DYNAMIC USER
XXX XXX XXX
Invalid Dynamic code will prompt the LCD to display the message: WRONG
DYNAMIC CODE
If the Dynamic Code is entered 30 minutes before his activation time DYNAMIC CODE
LCD will display the message: BROUGHT FORWARD
If the Dynamic Code is entered 30 minutes after his activation time DYNAMIC CODE
LCD will display the message: EXPIRED
Dynamic Codes must be used respecting the sequence of activation DYNAMIC CODE
time in which they have been created by the software, otherwise the UNUSABLE
last created code will delete all the previous ones (i.e. if three codes
are created and the third one is used before the first and the second
ones, the two first codes will be deleted). LCD will show the message:
Enter the Dynamic Code. LCD will display the message: OPEN
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
Power up TechMaster (select the lock if two or more locks are installed).
Enter a valid user code and insert the Dallas key, if set-up. LCD will 2° USER CODE
display the message: XX–XXXXXX
IU_TechMaster_02_eng Page 27 of 32
Enter a second valid user code and insert the Dallas key, if set-up. OPEN
LCD will display the message
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
Power up TechMaster and select the lock when two or more locks are installed.
Enter a valid user code and insert the Dallas key, if set-up. LCD will TIME DELAY
display Time Delay counting time: 00:59
Invalid code will prompt LCD to display the message WRONG CODE
STOP DELAY
To abort Time Delay press and then to confirm. COUNTING?
SELECT
To operate with other locks press during Time Delay counting LOCK:
After Time Delay has elapsed, the LCD will display the Open Window OPEN WINDOW
counting time. 00:01
USER CODE
Press , LCD will display the message: XX–XXXXXX
Enter a valid user code and insert the Dallas key, if set-up. LCD will 2° USER CODE
display the message: XX–XXXXXX
Enter a second valid user code and insert the Dallas key, if set-up. OPEN
LCD will display the message
Invalid code will prompt LCD to display the message WRONG CODE
Before power-off, LCD will display current date and time. 11:44 WED
01 / 09 / 2010
Page 28 of 32 IU_TechMaster_02_eng
8. Shortcuts
Use shortcuts to skip the procedure to get into a menu.
Power up TechMaster.
Press and hold the button corresponding to the menu you want to access to.
= Access to Change User Code function. Press to change Manager, OVR Manager
or Master code.
9. Optional features
9.1. Codes Expiry
TechMaster can be set to have automatic Codes’ Expiry (from 1 to 240 months) option.
If this option is set, LCD will display a warning message when a valid CODE WILL EXPIRE IN
code is entered starting from one week before the expiry date. 7 DAYS
When LCD will display this message change your code.
To change your code is the only function you will be allowed to do.
If your code is expired you will be not allowed to open the lock. Change your code before
operating the lock again.
TechMaster can be set to have Override Reopening option (from 0 to 59 minutes). If this
option is set, it will be possible to reopen the lock overriding Time Delay during the set value
IU_TechMaster_02_eng Page 29 of 32
of time. This function is available only after a standard opening procedure of the lock (after
opening with time delay).
Power up TechMaster.
Enter a valid user code. LCD will display time delay counting: TIME DELAY
00:59
After Time Delay LCD will display open window counting: OPEN WINDOW
00:01
Enter a valid user code. LCD will display the message: OPEN
Starting from this moment it will be possible, for the value of time set, to close and open
again the lock overriding Time Delay.
Page 30 of 32 IU_TechMaster_02_eng
DICHIARAZIONE CE DI CONFORMITA’
CE DECLARATION OF CONFORMITY
TechMaster: T9530
Franco Miller
Amministratore Unico
Before operating the lock,
please read this manual thoroughly,
and retain it for future reference.
TECNOSICUREZZA s.r.l.
Via Cesare Battisti, 276 – 37057 S. Giovanni Lupatoto (VR) – Italy
Tel. +39 045 826 64 70 - Fax +39 045 826 64 69
mail: info@tecnosicurezza.it - web: www.tecnosicurezza.it